CUADRO DE CARGAS - TABLERO ESTABILIZADO

D.M. CUMPLE
C/U P.I. D.M. T F.P. I Id L SECCION ∆V
TABLERO CTO. DESCRIPCION CANT. F.D. TOTAL SIST. K' K" < 1.5% I.T.M. CONDUCTOR ALIMENTADOR TUBERIA
(W) (KW) (KW) (V) (CosФ) (A) (A) (m) (mm2) (V%)
(KW) (Vn)
CE-1 TOMACORRIENTE ESTABILIZADO 2.00 300.00 0.60 60% 0.36
CE-2 TOMACORRIENTE ESTABILIZADO 3.00 300.00 0.90 60% 0.54
STDE-1.1 2.34 1Ф 220 0.85 12.51 15.64 1.00 2.00 14.00 6.00 1.09 SI 2x30 AMP. (2-1 x 6.0 + 1x6.0-T)mm2 NH-80 25 mm ∅ PVC-SAP
CE-3 TOMACORRIENTE ESTABILIZADO 4.00 300.00 1.20 60% 0.72
CE-4 TOMACORRIENTE ESTABILIZADO 4.00 300.00 1.20 60% 0.72
CE-1 TOMACORRIENTE ESTABILIZADO 10.00 300.00 3.00 60% 1.80
CE-2 TOMACORRIENTE ESTABILIZADO 10.00 300.00 3.00 60% 1.80
CE-3 TOMACORRIENTE ESTABILIZADO 10.00 300.00 3.00 60% 1.80
STDE-2.1 6.66 1Ф 220 0.85 35.61 44.51 1.00 2.00 10.00 10.00 1.32 SI 2x40 AMP. (2-1 x 10 + 1x10-T)mm2 NH-80 35 mm ∅ PVC-SAP
CE-4 TOMACORRIENTE ESTABILIZADO 2.00 300.00 0.60 60% 0.36
CE-5 TOMACORRIENTE ESTABILIZADO 2.00 300.00 0.60 60% 0.36
CE-6 TOMACORRIENTE ESTABILIZADO 3.00 300.00 0.90 60% 0.54