Está en la página 1de 7

MODELO DE POTENCIA HOGG & FUERSTENAU piñon y catalina

Eff. Diameter= 12.5 ft


Eff. Length= 19.5 ft
Mill Speed, rpm = 16.0
Balls Charge, % = 35
Gross Power, kW = 1,383
%Solids= 75.3
Ore density, ton/m3=3.01
10% losses
APLICACIÓN DE LA LEY DE BOND - TONELAJE TRATADO

Eff. Diameter= 12.5 ft


Eff. Length= 19.5 ft
Mill Speed, % 74
Balls Charge, % = 35
Gross Power, kW = 1,383
%Solids= 75.3 simular con 1460 Kw max.
Ore density, ton/m3=3.01 Wio 16.6511879
Feed Size, F80 = 4500 microns,
Product Size, P80 = 160 microns
Throughput, ton/hr= 123
%losses 5%
APLICACIÓN DE LA LEY DE BOND - TONELAJE TRATADO

Eff. Diameter= 12.5 ft


Eff. Length= 19.5 ft
Mill Speed, % = 74
Balls Charge, % = 35
Gross Power, kW = 1,383
%Solids= 75.3 Simular con 1460 Kw max.
Ore density, ton/m3=3.01 Wio
Feed Size, F80 = 4500 microns, Nivel de bolas máximo 40%
Product Size, P80 = 160 microns
Throughput, ton/hr= 123
%losses 5%
mular con 1460 Kw max.
16.6511879
ivel de bolas máximo 40%
APLICACIÓN DE LA LEY DE BOND

Eff. Diameter= 24.5 ft


Eff. Length= 36 ft
Mill Speed, % = 76
Balls Charge, % = 30
Gross Power, kW = 11,317
%Solids= 72.0
Ore density, ton/m3=2.93
Feed Size, F80 = 6000 microns,
Product Size, P80 = 150 microns
Throughput, ton/hr= 845
%Losses = 5.0
Wi, kWh/t = 18.5

Se requiere lo siguiente:

1.- Evaluar el efecto de incrementar el nivel de bolas de 25 a 45% sobre la potencia del molino y el TPH
2.- Evaluar el efecto de incrementar la velocidad de giro del molino de 74% a 78% sobre la potencia y TPH.
3.- Evaluar el efecto de incrementar la fineza del alimento (F80) de 6,000 a 4,500 micras sobre el TPH.
4.- Evaluar el efecto de reducir la fineza del producto (P80) de 150 a 200 micras sobre el TPH.
ia del molino y el TPH
% sobre la potencia y TPH.
micras sobre el TPH.
obre el TPH.

También podría gustarte