MEDIDA DE LA TEMPERATURA
Solución:
+5V
+5V
RT
R -
VREF
1 1 1 1
B( - ) 3600( − )
RT = R0 e T T0
= 100e 373 298
= 8812Ω
δ∆T 10 x0,1
Imax ≤ = = 0,33 mA
R T (100 ) 8812
1
R 6363
V+ = 5 V ⋅ =5 = 2,1 V
R + R100 6363 + 8812
Solución:
1 R0 1 100
B= ln = ln ≈ 2000
1 1 R1 1 1 13,7
- -
T0 T1 298 423
B - 2TC
R= RT
B + 2TC C
1 1 1 1
B( - ) 2000( )
donde: TC = 100ºC y R Tc = R 0 e
Tc T0
= 100e 373 298
≈ 21,31 kΩ
resulta: R≈ 12kΩ.
u
uo
RT
uo R
uo ( T ) = u
R R + RT
T (ºC)
50 100 150
2
R∆T 12000 x0,26
umáx = 2 =2 = 11,17 V
Rθ 100
tomamos 11 V.
1 1
2000 ( )
R T (50º C) = 100e 323 298
≈ 59,19 kΩ
12
uomín = 11 = 1,854 V
12 + 59,19
12
uomáx = 11 = 5,136 V
12 + 13,7
0 V=(R2/R1) (1,854-u1)
10 V= (R2/R1) (5,136-u1
De igual forma para el margen de salida -5÷5V, resulta el mismo valor de R2/R1 y
u1=3,5 V. La figura muestra el esquema propuesto.
1,8 V 3,5 V
R2
11 V
u1 R1
- R2
RT - uo 2 = (u - u )
+ R1 2 1
+ u2 R1
R2
R
3
3.- Se desea realizar una medida de temperatura entre 0ºC y 50ºC. Para ello se
utiliza como elemento sensor una NTC, cuyas principales características son:
resistencia a 25ºC, 100 kΩ±1%; margen de temperatura: -40ºC a 125ºC;
B=4190K; coeficiente de disipación, 10 mW/ºC. Se pide:
a) Calcular los elementos del circuito R1 y VDD si el error máximo permitido es
de 0,1ºC.
b) Si el margen de entrada del CAD es de 0 a 10V, diseñe el circuito de
adaptación de niveles.
c) Si se desea una medida ratiométrica de la temperatura que valor ha de tomar
VREF.
d) Donde situaría un filtro paso bajo RC de 1 Hz. Dibuje su esquema y calcule
los valores de R y C.
+VDD
VREF
RT
Conversión CAD
0 – 10V Vin 10 bits
R1
Solución:
a)
TC=25ºC
b)
1 1 1 1
B( - ) 4190( - )
R T max (0º C) = R 0 e Tc T0
= 100e 273 298
= 362,2 kΩ
1 1 1 1
B( - ) 4190( - )
R T min (50º C) = R 25 e Tc T0
= 100ke 323 298
= 33,68 kΩ
4
R1 75,1k
Vo max = VDD = 5V = 3,4 V
R1 + R T min 75,1k + 33,68k
R1 75,1k
Vo min = VDD = 5V = 0,8 V
R1 + R T max 75,1k + 362,4k
R2
Vo = (V2 − V1 ) , sustituyendo valores, resulta:
R1
R2
0V= (0,8V − V1 )
R1
R2
10 V = (3,4V − V1 )
R1
R2
+5 V
v1
R1
RT
-
- vo
R1
+
+ v2
R2
R1
c) VREF = VDD
1
d) Delante del CAD; fC = = 1 Hz
2πRC
5
4.- La temperatura medida por una RTD se puede encontrar en el margen de
0ºC a 100ºC. Diseñe el circuito de acondicionamiento necesario para lograr una
señal de salida en el margen de 0 a 5V. Utilice una referencia de corriente de
100 µA y conexión a 4 hilos. Datos de la RTD: Cu, R0 = 100 Ω, α = 0,00421K-1.
Solución:
Para T=0ºC:
Para T=100ºC:
Con un AI realizamos una amplificación previa de 100 con lo que la salida estará en
el margen de 1 V a 1,421 V. Para pasar al margen 0 V a 5 V, se puede proceder
como en el ejercicio anterior.
0,1 mA +tº Vd AI Vo
Temperatura
20ºC
Metal 1
145ºC
Metal 2
Voltímetro
6
b) Si la tensión medida fuera de 3,422 mV, ¿a qué temperatura está la zona la
unión suponiendo que el equipo de medición sigue a 20ºC?
Solución:
De la tabla obtiene que V145,0 = 5,937 mV y V20,0 = 0,798 mV. Por la tanto, la tensión
medida será de 5,139mV.
b) Si la tensión medida Vx,20, cuando una unión está a una temperatura x, y la otra a
20ºC, es de 3,422 mV:
Vx,0 -V20,0 =Vx,20
7
ºC 0 1 2 3 4 5 6 7 8 9 10 ºC
Tensión termoeléctrica (mV)
0 0.000 0.039 0.079 0.119 0.158 0.198 0.238 0.277 0.317 0.357 0.397 0
10 0.397 0.437 0.477 0.517 0.557 0.597 0.637 0.677 0.718 0.758 0.798 10
20 0.798 0.838 0.879 0.919 0.960 1.000 1.041 1.081 1.122 1.163 1.203 20
30 1.203 1.244 1.285 1.326 1.366 1.407 1.448 1.489 1.530 1.571 1.612 30
40 1.612 1.653 1.694 1.735 1.776 1.817 1.858 1.899 1.941 1.982 2.023 40
50 2.023 2.064 2.106 2.147 2.188 2.230 2.271 2.312 2.354 2.395 2.436 50
60 2.436 2.478 2.519 2.561 2.602 2.644 2.685 2.727 2.768 2.810 2.851 60
70 2.851 2.893 2.934 2.976 3.017 3.059 3.100 3.142 3.184 3.225 3.267 70
80 3.267 3.308 3.350 3.391 3.433 3.474 3.516 3.557 3.599 3.640 3.682 80
90 3.682 3.723 3.765 3.806 3.848 3.889 3.931 3.972 4.013 4.055 4.096 90
100 4.096 4.138 4.179 4.220 4.262 4.303 4.344 4.385 4.427 4.468 4.509 100
110 4.509 4.550 4.591 4.633 4.674 4.715 4.756 4.797 4.838 4.879 4.920 110
120 4.920 4.961 5.002 5.043 5.084 5.124 5.165 5.206 5.247 5.288 5.328 120
130 5.328 5.369 5.410 5.450 5.491 5.532 5.572 5.613 5.653 5.694 5.735 130
140 5.735 5.775 5.815 5.856 5.896 5.937 5.977 6.017 6.058 6.098 6.138 140
150 6.138 6.179 6.219 6.259 6.299 6.339 6.380 6.420 6.460 6.500 6.540 150
160 6.540 6.580 6.620 6.660 6.701 6.741 6.781 6.821 6.861 6.901 6.941 160
170 6.941 6.981 7.021 7.060 7.100 7.140 7.180 7.220 7.260 7.300 7.340 170
180 7.340 7.380 7.420 7.460 7.500 7.540 7.579 7.619 7.659 7.699 7.739 180
190 7.739 7.779 7.819 7.859 7.899 7.939 7.979 8.019 8.059 8.099 8.138 190
200 8.138 8.178 8.218 8.258 8.298 8.338 8.378 8.418 8.458 8.499 8.539 200
Solución:
La unión de referencia variará en el margen 0-30ºC, por lo que igual que antes
linealizando en dicho margen de medida, se tiene:
1,203 mV - 0,397 mV
VT 2,0 = ⋅ T2 = 40,00T2 (µV )
30 - 10
8
resistencias iguales en las ramas superiores y de un valor r veces mayor que la
resistencia R0 de la RTD (R1=R2=R=rR0), así como seleccionar R3= R0.
10V 10V
R1 R2 r100 r100
VT f , 0 VT f , 0
- + - +
R3 Rt = 100(1+αTf)
Rt = 100(1+αTf) 100
(a) (b)
⎡ Rt 100 ⎤
VT 2,0 = 10 ⎢ - ⎥ = 40 x10 T2
6
(µV )
R
⎣ t + r100 100 + r100 ⎦
operando:
RT 1 100(1+αT2 ) 1
- =4 ×10- 6 T2 Þ - =4 ×10- 6 T2
RT +r100 1+r 100[(1+αT2 ) + r ] 1+r
1+αT2 1
- =4 ×10- 6 T2
(1+αT2 + r ) /r+1)
rαT2
=4 ×10- 6 T2
(r+1)(1+αT2 + r )
rαT2
2
= 4 x10 −6 T2 ⇒ r = 960
r
9
10V
T2 r100 r100
+
- + +
+ VT2 ,0 +
T1 VT1,T2 VT1,0 AI
- - -
-
100
Bloque
isotermo
Solución:
Cu
+ +
TC Tf VTC,Tf Sumador VTC,0
- Cu -
VTf,0
10mV/ Acondicionador
ºC
10
Linealizando la respuesta del termopar en el margen 0ºC -500ºC:
20,644 mV - 0,000mV
VTc,0 = ⋅ TC = 0,041TC (mV /º C)
500º C
1,203 mV - 0,000mV
VTf ,0 = ⋅ Tf = 0,040 ⋅ Tf (mV /º C)
30º C
⎛ R ⎞ mV ⎛ R ⎞ mV
V2 = V1 ⎜⎜ − 2 ⎟⎟ = 10 ⋅ Tf ⋅ ⎜⎜ − 2 ⎟⎟ = 0,040 ⋅ Tf
⎝ R1 ⎠ ºC ⎝ R1 ⎠ ºC
R2
= 0,0040 ⇒ R 2 = 0,0040 ⋅ R1
R1
+
AI vo
TC Tf -
R2
v1 R1
-
10mV/ºC + v2
11
8.- El circuito de la figura utiliza el sensor integrado de temperatura LM35 para
realizar la compensación de la unión “fría” del termopar. Dicho sensor tiene
una sensibilidad de 10,0 mV/ºC entre 0 y 100 ºC, con una exactitud de ±0,25ºC.
La salida del sensor está conectada al terminar de referencia de un
amplificador de instrumentación. Si el termopar es de tipo K, y el amplificador
se considera ideal determinar la ganancia del amplificador de forma que la
tensión de salida sea independiente de la temperatura ambiente. Se adjunta la
tabla de las tensiones termoeléctricas del termopar K, expresadas en mV.
Bloque isotermo
Ta
RG AI
REF vo
+5V
LM35
Solución:
12