Está en la página 1de 36

Comprobaciones E.L.U.

PROYECTO HORMIGON

1. COLUMNAS

1.1. C1

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q(4) Q 1.94 0.73 -0.10 0.04 -0.53


Cabeza Cumple Cumple 10.2 5.9 N.P.(3) Cumple 10.2 Cumple
G, Q, S(5) N,M S. 0.92 0.35 -0.23 0.18 -0.25
P8 (21.7 - 24.5 m) 20x60
G, Q (4)
Q 2.86 -0.62 0.01 0.04 -0.53
Pie Cumple Cumple 5.8 5.7 N.P.(3) Cumple 5.8 Cumple
G, Q, S(6) N,M S. 2.16 -0.37 -0.23 -0.13 -0.31
G, Q, S (6)
Q S. 3.86 0.20 0.31 -0.25 -0.19
Cabeza Cumple Cumple 4.2 6.9 N.P.(3) Cumple 6.9 Cumple
G, Q, S(6) N,M S. 3.85 0.21 0.31 -0.25 -0.19
P7 (19 - 21.7 m) 20x60
G, Q(4) Q 6.22 -0.43 -0.11 -0.11 -0.32
Pie Cumple Cumple 3.5 6.9 N.P.(3) Cumple 6.9 Cumple
G, Q, S(6) N,M S. 4.78 -0.25 -0.29 -0.25 -0.19
Cabeza Cumple Cumple 4.0 7.8 N.P.(3) Cumple 7.8 G, Q(4) Q,N,M 8.71 0.49 0.11 -0.08 -0.39 Cumple
P6 (16.3 - 19 m) 20x60
Pie Cumple Cumple 4.0 8.4 N.P.(3) Cumple 8.4 G, Q(4) Q,N,M 9.59 -0.46 -0.09 -0.08 -0.39 Cumple
Cabeza Cumple Cumple 3.7 10.2 N.P.(3) Cumple 10.2 G, Q(4) Q,N,M 12.07 0.44 0.13 -0.10 -0.36 Cumple
P5 (13.6 - 16.3 m) 20x60
Pie Cumple Cumple 3.7 10.9 N.P. (3)
Cumple 10.9 G, Q(4) Q,N,M 12.95 -0.45 -0.11 -0.10 -0.36 Cumple
Cabeza Cumple Cumple 3.3 12.8 N.P.(3) Cumple 12.8 G, Q(4) Q,N,M 15.42 0.43 0.13 -0.10 -0.34 Cumple
P4 (10.9 - 13.6 m) 20x60
Pie Cumple Cumple 3.3 13.4 N.P.(3) Cumple 13.4 G, Q(4) Q,N,M 16.30 -0.40 -0.11 -0.10 -0.34 Cumple
Cabeza Cumple Cumple 3.8 15.5 N.P.(3) Cumple 15.5 G, Q(4) Q,N,M 18.75 0.44 0.13 -0.10 -0.40 Cumple
P3 (8.2 - 10.9 m) 20x60
Pie Cumple Cumple 3.8 16.3 N.P. (3)
Cumple 16.3 G, Q(4) Q,N,M 19.63 -0.54 -0.12 -0.10 -0.40 Cumple
G, Q, S(7) Q S. 15.50 0.17 0.16 -0.13 -0.02
Cabeza Cumple Cumple 0.9 17.9 N.P.(3) Cumple 17.9 Cumple
G, Q(4) N,M 22.03 0.32 0.10 -0.06 -0.06
P2 (5.5 - 8.2 m) 20x60
G, Q, S (7)
Q S. 16.41 0.12 -0.15 -0.13 -0.02
Pie Cumple Cumple 0.9 18.4 N.P.(3) Cumple 18.4 Cumple
G, Q(4) N,M 22.91 0.16 -0.06 -0.06 -0.06
G, Q, S (6)
Q S. 19.85 -0.23 0.17 -0.15 0.06
Cabeza Cumple Cumple 1.2 21.9 N.P.(3) Cumple 21.9 Cumple
G, Q(4) N,M 26.89 -0.34 0.13 -0.09 0.09
P1 (2.7 - 5.5 m) 20x60
G, Q, S(6) Q S. 20.74 -0.08 -0.18 -0.15 0.06
Pie Cumple Cumple 1.1 22.4 N.P.(3) Cumple 22.4 Cumple
G, Q(4) N,M 27.76 -0.13 -0.10 -0.09 0.09
Cabeza Cumple Cumple 3.7 24.9 N.P. (3)
Cumple 24.9 G, Q (4)
Q,N,M 30.18 0.56 0.18 -0.15 -0.41 Cumple
ENTREPISO (0 - 2.7 m) 20x60
Pie Cumple Cumple 3.7 25.5 N.P.(3) Cumple 25.5 G, Q(4) Q,N,M 31.06 -0.45 -0.17 -0.15 -0.41 Cumple
Cabeza Cumple Cumple 1.7 27.3 N.P.(3) Cumple 27.3 G, Q(4) Q,N,M 33.54 0.29 0.21 -0.12 -0.18 Cumple
PB (-2.66 - 0 m) 20x60
Pie Cumple Cumple 1.7 28.0 N.P.(3) Cumple 28.0 G, Q(4) Q,N,M 34.41 -0.13 -0.07 -0.12 -0.18 Cumple
SUBSUELO 20x60 Arranque N.P.(1) N.P.(1) N.P.(2) 28.0 N.P.(1) Cumple 28.0 G, Q(4) N,M 34.41 -0.13 -0.07 -0.12 -0.18 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+0.5·Qa-SY
(6)
1.245·PP+1.245·CM+0.5·Qa+SY
(7)
1.245·PP+1.245·CM+0.5·Qa-SX

1.2. C2

Página 1
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cumple G, Q, S(4) Q S. 4.33 0.57 0.58 -0.50 -0.43


14.7
Cabeza Cumple 9.5 N.P.(3) Cumple 14.7 Cumple
G, Q(5) N,M 7.40 0.84 0.57 -0.48 -0.62
P8 (21.7 - 24.5 m) 20x60

G, Q, S(4) Q S. 5.28 -0.53 -0.71 -0.51 -0.43


Pie Cumple Cumple 9.7 15.7 N.P.(3) Cumple 15.7 Cumple
G, Q(5) N,M 8.32 -0.75 -0.65 -0.48 -0.62
G, S(6) Q S. 6.35 0.19 0.60 -0.49 -0.18
Cabeza Cumple Cumple 7.9 16.8 N.P.(3) Cumple 16.8 Cumple
G, Q(5) N,M 15.15 0.45 0.64 -0.52 -0.39
P7 (19 - 21.7 m) 20x60
G, S (6)
Q S. 7.26 -0.24 -0.60 -0.49 -0.18
Pie Cumple Cumple 7.8 17.3 N.P.(3) Cumple 17.3 Cumple
G, Q(5) N,M 16.04 -0.51 -0.64 -0.52 -0.39
Cabeza Cumple Cumple 5.9 21.6 N.P.(3) Cumple 21.6 G, Q(5) Q,N,M 22.78 0.55 0.70 -0.56 -0.43 Cumple
P6 (16.3 - 19 m) 20x60
Pie Cumple Cumple 5.9 21.7 N.P.(3) Cumple 21.7 G, Q(5) Q,N,M 23.66 -0.51 -0.68 -0.56 -0.43 Cumple
Cabeza Cumple Cumple 5.6 25.9 N.P.(3) Cumple 25.9 G, Q(5) Q,N,M 30.37 0.50 0.71 -0.58 -0.42 Cumple
P5 (13.6 - 16.3 m) 20x60
Pie Cumple Cumple 5.5 26.3 N.P.(3) Cumple 26.3 G, Q(5) Q,N,M 31.25 -0.53 -0.70 -0.58 -0.42 Cumple
Cabeza Cumple Cumple 4.8 31.2 N.P.(3) Cumple 31.2 G, Q(5) Q,N,M 37.91 0.42 0.74 -0.60 -0.28 Cumple
P4 (10.9 - 13.6 m) 20x60
Pie Cumple Cumple 4.7 31.8 N.P.(3) Cumple 31.8 G, Q(5) Q,N,M 38.79 -0.26 -0.72 -0.60 -0.28 Cumple
Cabeza Cumple Cumple 6.8 37.8 N.P.(3) Cumple 37.8 G, Q(5) Q,N,M 45.43 0.53 0.75 -0.60 -0.70 Cumple
P3 (8.2 - 10.9 m) 20x60
Pie Cumple Cumple 6.8 39.7 N.P.(3) Cumple 39.7 G, Q(5) Q,N,M 46.31 -1.19 -0.73 -0.60 -0.70 Cumple
Cabeza Cumple Cumple 9.3 44.0 N.P.(3) Cumple 44.0 G, Q(5) Q,N,M 52.86 -0.14 0.75 -0.61 1.13 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 9.2 49.6 N.P. (3)
Cumple 49.6 G, Q(5) Q,N,M 53.75 2.63 -0.74 -0.61 1.13 Cumple
Cabeza Cumple Cumple 15.8 64.7 N.P.(3) Cumple 64.7 G, Q(5) Q,N,M 67.07 -3.82 0.68 -0.46 2.25 Cumple
P1 (2.7 - 5.5 m) 20x60
Pie Cumple Cumple 15.7 59.4 N.P.(3) Cumple 59.4 G, Q(5) Q,N,M 67.93 1.57 -0.41 -0.46 2.25 Cumple
Cabeza Cumple Cumple 5.2 23.1 N.P.(3) Cumple 23.1 G, Q(5) Q,N,M 73.37 1.37 1.74 -1.12 -0.83 Cumple
ENTREPISO (0 - 2.7 m) Diámetro 60
Pie Cumple Cumple 5.2 23.8 N.P.(3) Cumple 23.8 G, Q(5) Q,N,M 75.45 -0.67 -1.00 -1.12 -0.83 Cumple
Cabeza Cumple Cumple 2.6 25.8 N.P.(3) Cumple 25.8 G, Q(5) Q,N,M 82.01 0.08 1.56 -0.70 -0.02 Cumple
PB (-2.66 - 0 m) Diámetro 60
Pie Cumple Cumple 2.6 26.5 N.P.(3) Cumple 26.5 G, Q(5) Q,N,M 84.05 0.02 -0.14 -0.70 -0.02 Cumple
SUBSUELO Diámetro 60 Arranque N.P.(1) N.P.(1) N.P.(2) 26.5 N.P.(1) Cumple 26.5 G, Q(5) N,M 84.05 0.02 -0.14 -0.70 -0.02 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa+SY
(5)
1.2·PP+1.2·CM+1.6·Qa
(6)
1.245·PP+1.245·CM+SY

1.3. C3

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 29.3 42.3 N.P.(3) Cumple 42.3 G, Q(4) Q,N,M 4.36 0.82 -1.74 1.43 -0.60 Cumple
P8 (21.7 - 24.5 m) 20x60
Pie Cumple Cumple 29.3 45.3 N.P.(3) Cumple 45.3 G, Q(4) Q,N,M 5.28 -0.72 1.90 1.43 -0.60 Cumple
21.7 m N.P.(1) N.P.(1) N.P.(2) 45.3 N.P.(1) Cumple 45.3 G, Q(4) N,M 5.28 -0.72 1.90 1.43 -0.60 Cumple
P7 (19 - 21.7 m) 20x60 Cabeza Cumple Cumple 26.5 30.5 N.P.(3) Cumple 30.5 G, Q(4) Q,N,M 10.12 0.43 -1.59 1.33 -0.37 Cumple
Pie Cumple Cumple 26.5 32.5 N.P.(3) Cumple 32.5 G, Q(4) Q,N,M 11.00 -0.49 1.68 1.33 -0.37 Cumple
Cabeza Cumple Cumple 26.8 35.0 N.P.(3) Cumple 35.0 G, Q(4) Q,N,M 15.77 0.55 -1.71 1.40 -0.44 Cumple
P6 (16.3 - 19 m) 20x60
Pie Cumple Cumple 26.5 35.3 N.P.(3) Cumple 35.3 G, Q(4) Q,N,M 16.65 -0.51 1.71 1.40 -0.44 Cumple
P5 (13.6 - 16.3 m) 20x60 Cabeza Cumple Cumple 14.2 36.7 N.P. (3)
Cumple 36.7 G, Q, S(5) Q S. 13.13 0.11 -1.10 0.91 -0.08 Cumple

Página 2
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q(4) N,M 21.39 0.49 -1.66 1.36 -0.41


G, Q, S(5) Q S. 14.03 -0.07 1.12 0.90 -0.08
Pie Cumple Cumple 14.1 37.6 N.P.(3) Cumple 37.6 Cumple
G, Q(4) N,M 22.27 -0.51 1.68 1.36 -0.41
Cabeza Cumple Cumple 10.7 38.5 N.P.(3) Cumple 38.5 G, Q(4) Q,N,M 26.96 0.45 -1.65 1.35 -0.34 Cumple
P4 (10.9 - 13.6 m) 20x60
Pie Cumple Cumple 10.6 39.0 N.P.(3) Cumple 39.0 G, Q(4) Q,N,M 27.84 -0.38 1.66 1.35 -0.34 Cumple
Cabeza Cumple Cumple 10.9 40.6 N.P.(3) Cumple 40.6 G, Q(4) Q,N,M 32.49 0.48 -1.63 1.34 -0.56 Cumple
P3 (8.2 - 10.9 m) 20x60
Pie Cumple Cumple 10.8 42.5 N.P.(3) Cumple 42.5 G, Q(4) Q,N,M 33.37 -0.90 1.65 1.34 -0.56 Cumple
Cabeza Cumple Cumple 9.9 42.2 N.P. (3)
Cumple 42.2 G, Q(4) Q,N,M 37.92 0.07 -1.61 1.30 0.44 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 9.8 44.7 N.P.(3) Cumple 44.7 G, Q(4) Q,N,M 38.80 1.16 1.58 1.30 0.44 Cumple
Cabeza Cumple Cumple 10.3 48.3 N.P.(3) Cumple 48.3 G, Q(4) Q,N,M 46.83 -1.54 -1.52 1.27 0.76 Cumple
P1 (2.7 - 5.5 m) 20x60
Pie Cumple Cumple 10.2 46.4 N.P.(3) Cumple 46.4 G, Q(4) Q,N,M 47.69 0.29 1.51 1.27 0.76 Cumple
Cabeza Cumple Cumple 9.1 48.9 N.P.(3) Cumple 48.9 G, Q(4) Q,N,M 52.02 0.89 -1.43 1.25 -0.57 Cumple
ENTREPISO (0 - 2.7 m) 20x60
Pie Cumple Cumple 9.1 51.6 N.P.(3) Cumple 51.6 G, Q(4) Q,N,M 52.91 -0.49 1.62 1.25 -0.57 Cumple
0m N.P. (1)
N.P. (1)
N.P. (2)
51.6 N.P. (1)
Cumple 51.6 G, Q(4) N,M 52.91 -0.49 1.62 1.25 -0.57 Cumple
PB (-2.66 - 0 m) 20x60 Cabeza Cumple Cumple 5.2 48.2 N.P.(3) Cumple 48.2 G, Q(4) Q,N,M 57.19 0.24 -1.23 0.81 -0.11 Cumple
Pie Cumple Cumple 5.2 48.5 N.P.(3) Cumple 48.5 G, Q(4) Q,N,M 58.06 -0.04 0.73 0.81 -0.11 Cumple
SUBSUELO 20x60 Arranque N.P. (1)
N.P. (1)
N.P. (2)
48.5 N.P. (1)
Cumple 48.5 G, Q(4) N,M 58.06 -0.04 0.73 0.81 -0.11 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+0.5·Qa-SY

1.4. C4

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 0.93 0.30 -0.20 0.18 0.11


Cabeza Cumple Cumple 3.6 4.7 N.P.(3) Cumple 4.7 Cumple
G, Q, S(5) N,M S. 1.29 0.43 0.20 -0.18 0.02
P10 (27.3 - 30.1 m) 25x50
G, Q, S (4)
Q S. 1.93 0.58 0.25 0.18 0.11
Pie Cumple Cumple 3.5 6.4 N.P.(3) Cumple 6.4 Cumple
G, Q, S(4) N,M S. 1.95 0.58 0.25 0.17 0.10
G, Q, S(5) Q S. 5.01 -1.02 0.06 -0.04 0.55
Cabeza Cumple Cumple 8.2 13.3 N.P.(3) Cumple 13.3 Cumple
P9 (24.5 - 27.3 m) 25x50 G, Q(6) N,M 8.45 -1.68 0.11 -0.11 0.84
Pie Cumple Cumple 7.4 7.8 N.P.(3) Cumple 7.8 G, Q(6) Q,N,M 9.40 0.45 -0.16 -0.11 0.84 Cumple
Cabeza Cumple Cumple 3.9 11.0 N.P.(3) Cumple 11.0 G, Q(6) Q,N,M 13.09 0.68 0.26 -0.17 -0.42 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 3.9 10.8 N.P.(3) Cumple 10.8 G, Q(6) Q,N,M 14.04 -0.39 -0.18 -0.17 -0.42 Cumple
G, Q, S(5) Q S. 12.03 0.11 0.30 -0.24 -0.11
Cabeza Cumple Cumple 2.1 12.9 N.P. (3)
Cumple 12.9 Cumple
G, Q(6) N,M 17.56 0.13 0.18 -0.13 -0.13
P7 (19 - 21.7 m) 25x50
G, Q, S (5)
Q S. 13.02 -0.15 -0.30 -0.25 -0.10
Pie Cumple Cumple 2.1 13.7 N.P.(3) Cumple 13.7 Cumple
G, Q(6) N,M 18.47 -0.18 -0.15 -0.13 -0.13
G, Q, S(5) Q S. 14.95 0.18 0.31 -0.24 -0.14
Cabeza Cumple Cumple 2.1 16.3 N.P.(3) Cumple 16.3 Cumple
G, Q(6) N,M 22.00 0.23 0.20 -0.14 -0.18
P6 (16.3 - 19 m) 25x50
G, Q, S (5)
Q S. 16.03 -0.17 -0.29 -0.24 -0.14
Pie Cumple Cumple 2.1 16.9 N.P.(3) Cumple 16.9 Cumple
G, Q(6) N,M 22.91 -0.20 -0.15 -0.14 -0.18
P5 (13.6 - 16.3 m) 25x50 G, Q, S (5)
Q S. 17.97 0.15 0.29 -0.23 -0.12
Cabeza Cumple Cumple 2.0 19.5 N.P.(3) Cumple 19.5 Cumple
G, Q(6) N,M 26.41 0.17 0.18 -0.13 -0.14
Pie Cumple Cumple 1.9 20.2 N.P.(3) Cumple 20.2 G, Q, S(5) Q S. 18.96 -0.15 -0.27 -0.23 -0.12 Cumple

Página 3
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q(6) N,M 27.33 -0.17 -0.13 -0.13 -0.14


G, Q, S(5) Q S. 20.97 0.13 0.27 -0.22 -0.12
Cabeza Cumple Cumple 1.9 22.8 N.P. (3)
Cumple 22.8 Cumple
G, Q(6) N,M 30.81 0.16 0.16 -0.11 -0.12
P4 (10.9 - 13.6 m) 25x50
G, Q, S (5)
Q S. 21.96 -0.15 -0.27 -0.22 -0.12
Pie Cumple Cumple 1.8 23.5 N.P.(3) Cumple 23.5 Cumple
G, Q(6) N,M 31.73 -0.15 -0.11 -0.11 -0.12
G, Q, S (5)
Q S. 23.99 0.08 0.22 -0.22 -0.08
Cabeza Cumple Cumple 1.7 26.1 N.P.(3) Cumple 26.1 Cumple
G, Q(6) N,M 35.18 0.12 0.14 -0.09 -0.09
P3 (8.2 - 10.9 m) 25x50
G, Q, S(5) Q S. 24.94 -0.11 -0.31 -0.22 -0.08
Pie Cumple Cumple 1.7 26.8 N.P.(3) Cumple 26.8 Cumple
G, Q(6) N,M 36.10 -0.10 -0.09 -0.09 -0.09
G, Q, S (7)
Q S. 26.22 0.06 0.17 -0.14 -0.04
Cabeza Cumple Cumple 1.1 29.4 N.P.(3) Cumple 29.4 Cumple
G, Q(6) N,M 39.51 0.10 0.09 -0.06 -0.08
P2 (5.5 - 8.2 m) 25x50
G, Q, S (7)
Q S. 27.18 -0.04 -0.18 -0.14 -0.04
Pie Cumple Cumple 1.0 30.0 N.P.(3) Cumple 30.0 Cumple
G, Q(6) N,M 40.43 -0.10 -0.04 -0.06 -0.08
G, Q, S(4) Q S. 27.61 0.08 0.04 0.00 -0.09
Cabeza Cumple Cumple 0.6 32.6 N.P.(3) Cumple 32.6 Cumple
G, Q(6) N,M 43.73 0.08 0.06 0.01 -0.06
P1 (2.7 - 5.5 m) 25x50
G, Q, S (4)
Q S. 28.60 -0.14 0.05 0.00 -0.09
Pie Cumple Cumple 0.6 33.3 N.P.(3) Cumple 33.3 Cumple
G, Q(6) N,M 44.68 -0.07 0.08 0.01 -0.06
G, Q, S (4)
Q S. 29.99 0.02 -0.01 -0.03 -0.04
Cabeza Cumple Cumple 0.3 35.1 N.P.(3) Cumple 35.1 Cumple
G, Q(6) N,M 47.04 0.03 0.01 -0.04 -0.01
ENTREPISO (0 - 2.7 m) 25x50
G, Q, S(4) Q S. 30.95 -0.08 -0.08 -0.03 -0.04
Pie Cumple Cumple 0.3 35.8 N.P.(3) Cumple 35.8 Cumple
G, Q(6) N,M 47.96 0.00 -0.07 -0.04 -0.01
G, Q, S(4) Q S. 33.53 -0.01 0.18 -0.15 -0.02
Cabeza Cumple Cumple 1.0 38.5 N.P.(3) Cumple 38.5 Cumple
G, Q(6) N,M 51.49 0.01 0.25 -0.14 0.00
PB (-2.66 - 0 m) 25x50
G, Q, S (4)
Q S. 34.48 -0.06 -0.17 -0.15 -0.02
Pie Cumple Cumple 1.0 39.2 N.P.(3) Cumple 39.2 Cumple
G, Q(6) N,M 52.39 0.00 -0.07 -0.14 0.00
SUBSUELO 25x50 Arranque N.P.(1) N.P.(1) N.P.(2) 39.2 N.P.(1) Cumple 39.2 G, Q(6) N,M 52.39 0.00 -0.07 -0.14 0.00 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
1.245·PP+1.245·CM+0.5·Qa+SY
(6)
1.2·PP+1.2·CM+1.6·Qa
(7)
1.245·PP+1.245·CM+0.5·Qa-SX

1.5. C5

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 21.0 16.2 N.P.(3) Cumple 21.0 G, Q(4) Q,N,M 6.98 1.15 0.60 -0.73 1.60 Cumple
P10 (27.3 - 30.1 m) 20x60
Pie Cumple Cumple 38.7 48.5 N.P.(3) Cumple 48.5 G, Q(4) Q,N,M 7.90 5.22 -1.25 -0.73 1.60 Cumple
Cabeza Cumple Cumple 62.7 68.7 N.P.(3) Cumple 68.7 G, Q(4) Q,N,M 28.36 -7.82 1.48 -0.97 3.96 Cumple
P9 (24.5 - 27.3 m) 20x60
Pie Cumple Cumple 34.8 34.5 N.P.(3) Cumple 34.8 G, Q(4) Q,N,M 29.27 2.28 -1.00 -0.97 3.96 Cumple
Cabeza Cumple Cumple 11.9 35.4 N.P.(3) Cumple 35.4 G, Q(4) Q,N,M 36.64 2.48 0.53 -0.45 -1.41 Cumple
P8 (21.7 - 24.5 m) 20x60
Pie Cumple Cumple 11.9 32.2 N.P.(3) Cumple 32.2 G, Q(4) Q,N,M 37.56 -1.11 -0.60 -0.45 -1.41 Cumple
G, Q, S(5) Q S. 27.43 0.05 0.74 -0.59 -0.13
Cabeza Cumple Cumple 4.1 36.9 N.P.(3) Cumple 36.9 Cumple
G, Q(4) N,M 44.92 -0.07 0.74 -0.59 -0.07
P7 (19 - 21.7 m) 20x60
G, Q, S(5) Q S. 28.34 -0.27 -0.71 -0.59 -0.13
Pie Cumple Cumple 4.0 37.9 N.P.(3) Cumple 37.9 Cumple
G, Q(4) N,M 45.80 -0.23 -0.70 -0.59 -0.07

Página 4
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 4.5 44.6 N.P.(3) Cumple 44.6 G, Q(4) Q,N,M 53.19 0.49 0.71 -0.57 -0.35 Cumple
P6 (16.3 - 19 m) 20x60
Pie Cumple Cumple 4.5 45.3 N.P.(3) Cumple 45.3 G, Q(4) Q,N,M 54.07 -0.38 -0.69 -0.57 -0.35 Cumple
Cabeza Cumple Cumple 3.9 52.0 N.P.(3) Cumple 52.0 G, Q(4) Q,N,M 61.51 0.27 0.72 -0.58 -0.22 Cumple
P5 (13.6 - 16.3 m) 20x60
Pie Cumple Cumple 3.9 52.8 N.P.(3) Cumple 52.8 G, Q(4) Q,N,M 62.39 -0.26 -0.70 -0.58 -0.22 Cumple
G, Q, S(5) Q S. 42.33 0.24 0.68 -0.55 -0.23
Cabeza Cumple Cumple 3.7 59.8 N.P.(3) Cumple 59.8 Cumple
P4 (10.9 - 13.6 m) 20x60 G, Q(4) N,M 69.87 0.24 0.73 -0.58 -0.19
Pie Cumple Cumple 3.7 60.7 N.P. (3)
Cumple 60.7 G, Q (4)
Q,N,M 70.75 -0.24 -0.70 -0.58 -0.19 Cumple
G, Q, S(5) Q S. 47.33 0.12 0.64 -0.55 -0.20
Cabeza Cumple Cumple 3.5 67.9 N.P. (3)
Cumple 67.9 Cumple
G, Q(4) N,M 78.27 0.14 0.73 -0.59 -0.10
P3 (8.2 - 10.9 m) 20x60
G, Q, S (5)
Q S. 48.24 -0.36 -0.69 -0.55 -0.20
Pie Cumple Cumple 3.5 68.8 N.P.(3) Cumple 68.8 Cumple
G, Q(4) N,M 79.15 -0.10 -0.71 -0.59 -0.10
Cabeza Cumple Cumple 3.0 76.5 N.P.(3) Cumple 76.5 G, Q(4) Q,N,M 86.78 0.05 0.69 -0.54 -0.07 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 3.0 77.5 N.P.(3) Cumple 77.5 G, Q(4) Q,N,M 87.66 -0.12 -0.63 -0.54 -0.07 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 71.9 N.P.(1) Cumple 71.9 G, Q(4) N,M 87.66 -0.12 -0.63 -0.54 -0.07 Cumple
P1 (2.7 - 5.5 m) 30x60 Cabeza Cumple Cumple 1.7 60.0 N.P.(3) Cumple 60.0 G, Q(4) Q,N,M 95.21 0.10 0.97 -0.37 -0.02 Cumple
Pie Cumple Cumple 1.7 61.2 N.P.(3) Cumple 61.2 G, Q(4) Q,N,M 96.59 0.05 0.02 -0.37 -0.02 Cumple
Cabeza Cumple Cumple 1.3 32.1 N.P.(3) Cumple 32.1 G, Q(4) Q,N,M 96.59 0.05 0.02 -0.37 -0.02 Cumple
ENTREPISO (0 - 2.7 m) Diámetro 60
Pie Cumple Cumple 1.3 32.9 N.P.(3) Cumple 32.9 G, Q(4) Q,N,M 98.88 0.00 -0.97 -0.37 -0.02 Cumple
Cabeza Cumple Cumple 4.7 33.9 N.P.(3) Cumple 33.9 G, Q(4) Q,N,M 107.66 0.01 2.36 -1.37 0.03 Cumple
PB (-2.66 - 0 m) Diámetro 60
Pie Cumple Cumple 4.7 34.5 N.P.(3) Cumple 34.5 G, Q(4) Q,N,M 109.54 0.07 -0.68 -1.37 0.03 Cumple
SUBSUELO Diámetro 60 Arranque N.P.(1) N.P.(1) N.P.(2) 34.5 N.P.(1) Cumple 34.5 G, Q(4) N,M 109.54 0.07 -0.68 -1.37 0.03 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+0.5·Qa+SY

1.6. C6

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 47.0 40.6 N.P.(3) Cumple 47.0 G, Q(4) Q,N,M 4.54 1.04 -2.25 2.24 0.50 Cumple
P10 (27.3 - 30.1 m) 25x50
Pie Cumple Cumple 48.1 66.5 N.P.(3) Cumple 66.5 G, Q(4) Q,N,M 5.50 2.31 3.45 2.24 0.50 Cumple
27.3 m N.P.(1) N.P.(1) N.P.(2) 66.5 N.P.(1) Cumple 66.5 G, Q(4) N,M 5.50 2.31 3.45 2.24 0.50 Cumple
P9 (24.5 - 27.3 m) 25x50 Cabeza Cumple Cumple 55.9 63.4 N.P.(3) Cumple 63.4 G, Q(4) Q,N,M 18.19 -3.90 -3.24 2.20 1.94 Cumple
Pie Cumple Cumple 42.6 39.2 N.P.(3) Cumple 42.6 G, Q(4) Q,N,M 19.15 1.05 2.37 2.20 1.94 Cumple
24.5 m N.P.(1) N.P.(1) N.P.(2) 39.2 N.P.(1) Cumple 39.2 G, Q(4) N,M 19.15 1.05 2.37 2.20 1.94 Cumple
P8 (21.7 - 24.5 m) 25x50 Cabeza Cumple Cumple 12.3 31.0 N.P.(3) Cumple 31.0 G, Q(4) Q,N,M 25.09 1.57 -1.41 1.20 -0.95 Cumple
Pie Cumple Cumple 12.2 31.8 N.P.(3) Cumple 31.8 G, Q(4) Q,N,M 26.05 -0.86 1.65 1.20 -0.95 Cumple
Cabeza Cumple Cumple 12.1 35.4 N.P.(3) Cumple 35.4 G, Q(4) Q,N,M 31.87 0.21 -1.89 1.53 -0.23 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 12.0 35.6 N.P.(3) Cumple 35.6 G, Q(4) Q,N,M 32.78 -0.36 1.85 1.53 -0.23 Cumple
Cabeza Cumple Cumple 11.0 37.0 N.P.(3) Cumple 37.0 G, Q(4) Q,N,M 38.60 0.49 -1.72 1.43 -0.38 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 10.9 38.0 N.P.(3) Cumple 38.0 G, Q(4) Q,N,M 39.52 -0.43 1.77 1.43 -0.38 Cumple
Cabeza Cumple Cumple 10.4 40.5 N.P. (3)
Cumple 40.5 G, Q(4) Q,N,M 45.30 0.36 -1.73 1.43 -0.29 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 10.4 41.3 N.P.(3) Cumple 41.3 G, Q(4) Q,N,M 46.22 -0.35 1.76 1.43 -0.29 Cumple
Cabeza Cumple Cumple 10.0 43.7 N.P.(3) Cumple 43.7 G, Q(4) Q,N,M 51.99 0.32 -1.71 1.41 -0.26 Cumple
P4 (10.9 - 13.6 m) 25x50
Pie Cumple Cumple 9.9 44.8 N.P.(3) Cumple 44.8 G, Q(4) Q,N,M 52.91 -0.32 1.76 1.41 -0.26 Cumple

Página 5
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 9.0 47.2 N.P.(3) Cumple 47.2 G, Q(4) Q,N,M 58.65 0.24 -1.66 1.33 -0.21 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 9.0 47.3 N.P.(3) Cumple 47.3 G, Q(4) Q,N,M 59.57 -0.27 1.61 1.33 -0.21 Cumple
Cabeza Cumple Cumple 10.2 51.9 N.P.(3) Cumple 51.9 G, Q(4) Q,N,M 65.32 0.11 -1.76 1.56 -0.10 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 10.1 55.4 N.P.(3) Cumple 55.4 G, Q(4) Q,N,M 66.24 -0.14 2.08 1.56 -0.10 Cumple
Cabeza Cumple Cumple 3.6 54.8 N.P. (3)
Cumple 54.8 G, Q(4) Q,N,M 71.77 0.19 -1.22 0.57 -0.12 Cumple
P1 (2.7 - 5.5 m) 25x50
Pie Cumple Cumple 3.6 55.5 N.P.(3) Cumple 55.5 G, Q(4) Q,N,M 72.72 -0.11 0.23 0.57 -0.12 Cumple
G, S(5) Q S. 33.98 -0.01 0.13 0.14 0.09
Cabeza Cumple Cumple 1.1 57.2 N.P.(3) Cumple 57.2 Cumple
G, Q(4) N,M 75.16 0.03 0.32 0.15 0.00
ENTREPISO (0 - 2.7 m) 25x50
G, S(5) Q S. 34.93 0.21 0.47 0.14 0.09
Pie Cumple Cumple 1.1 58.0 N.P.(3) Cumple 58.0 Cumple
G, Q(4) N,M 76.08 0.03 0.68 0.15 0.00
Cabeza Cumple Cumple 6.8 62.1 N.P. (3)
Cumple 62.1 G, Q (4)
Q,N,M 82.08 0.08 -1.51 1.13 -0.02 Cumple
PB (-2.66 - 0 m) 25x50
Pie Cumple Cumple 6.8 62.8 N.P.(3) Cumple 62.8 G, Q(4) Q,N,M 82.91 0.02 0.99 1.13 -0.02 Cumple
SUBSUELO 25x50 Arranque N.P.(1) N.P.(1) N.P.(2) 62.8 N.P.(1) Cumple 62.8 G, Q(4) N,M 82.91 0.02 0.99 1.13 -0.02 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+SY

1.7. C7

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 0.97 0.39 -0.27 0.23 0.01


Cabeza Cumple Cumple 4.2 7.0 N.P.(3) Cumple 7.0 Cumple
G, Q(5) N,M 2.08 0.84 -0.20 0.17 -0.03
P12 (32.9 - 35.7 m) 25x50
G, Q, S(4) Q S. 1.96 0.42 0.31 0.23 0.01
Pie Cumple Cumple 4.1 7.4 N.P.(3) Cumple 7.4 Cumple
G, Q(5) N,M 3.04 0.77 0.25 0.17 -0.03
Cabeza Cumple Cumple 14.4 13.6 N.P.(3) Cumple 14.4 G, Q(5) Q,N,M 8.62 -1.73 -0.01 -0.07 0.84 Cumple
P11 (30.1 - 32.9 m) 25x50
Pie Cumple Cumple 7.5 7.8 N.P.(3) Cumple 7.8 G, Q(5) Q,N,M 9.58 0.43 -0.17 -0.07 0.84 Cumple
Cabeza Cumple Cumple 5.2 12.7 N.P.(3) Cumple 12.7 G, Q(5) Q,N,M 13.95 0.84 0.38 -0.25 -0.56 Cumple
P10 (27.3 - 30.1 m) 25x50
Pie Cumple Cumple 5.2 12.0 N.P.(3) Cumple 12.0 G, Q(5) Q,N,M 14.90 -0.59 -0.26 -0.25 -0.56 Cumple
Cabeza Cumple Cumple 2.5 14.2 N.P.(3) Cumple 14.2 G, Q(5) Q,N,M 18.85 0.34 0.20 -0.15 -0.27 Cumple
P9 (24.5 - 27.3 m) 25x50
Pie Cumple Cumple 2.5 14.9 N.P.(3) Cumple 14.9 G, Q(5) Q,N,M 19.80 -0.35 -0.19 -0.15 -0.27 Cumple
Cabeza Cumple Cumple 2.6 17.9 N.P.(3) Cumple 17.9 G, Q(5) Q,N,M 23.92 0.36 0.24 -0.17 -0.28 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 2.6 18.6 N.P. (3)
Cumple 18.6 G, Q(5) Q,N,M 24.87 -0.36 -0.20 -0.17 -0.28 Cumple
Cabeza Cumple Cumple 2.6 21.6 N.P.(3) Cumple 21.6 G, Q(5) Q,N,M 28.95 0.37 0.22 -0.16 -0.30 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 2.5 22.3 N.P.(3) Cumple 22.3 G, Q(5) Q,N,M 29.87 -0.36 -0.17 -0.16 -0.30 Cumple
Cabeza Cumple Cumple 2.3 25.4 N.P.(3) Cumple 25.4 G, Q(5) Q,N,M 33.96 0.35 0.20 -0.14 -0.28 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 2.3 26.0 N.P.(3) Cumple 26.0 G, Q(5) Q,N,M 34.88 -0.35 -0.15 -0.14 -0.28 Cumple
Cabeza Cumple Cumple 2.2 29.1 N.P.(3) Cumple 29.1 G, Q(5) Q,N,M 38.94 0.35 0.17 -0.12 -0.28 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 2.1 29.8 N.P.(3) Cumple 29.8 G, Q(5) Q,N,M 39.86 -0.34 -0.11 -0.12 -0.28 Cumple
Cabeza Cumple Cumple 2.0 32.9 N.P.(3) Cumple 32.9 G, Q(5) Q,N,M 43.91 0.34 0.14 -0.09 -0.28 Cumple
P4 (10.9 - 13.6 m) 25x50
Pie Cumple Cumple 2.0 33.6 N.P.(3) Cumple 33.6 G, Q(5) Q,N,M 44.83 -0.35 -0.09 -0.09 -0.28 Cumple
Cabeza Cumple Cumple 1.7 36.7 N.P.(3) Cumple 36.7 G, Q(5) Q,N,M 48.86 0.32 0.09 -0.05 -0.25 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 1.7 37.4 N.P.(3) Cumple 37.4 G, Q(5) Q,N,M 49.78 -0.30 -0.02 -0.05 -0.25 Cumple
P2 (5.5 - 8.2 m) 25x50 Cabeza Cumple Cumple 2.0 40.4 N.P.(3) Cumple 40.4 G, Q(5) Q,N,M 53.73 0.35 0.02 0.00 -0.31 Cumple

Página 6
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Pie Cumple Cumple 2.0 41.2 N.P.(3) Cumple 41.2 G, Q(5) Q,N,M 54.65 -0.42 0.02 0.00 -0.31 Cumple
G, Q, S(4) Q S. 35.95 0.18 0.01 0.02 -0.11
Cabeza Cumple Cumple 0.7 44.4 N.P. (3)
Cumple 44.4 Cumple
G, Q(5) N,M 58.65 0.26 0.03 0.02 -0.11
P1 (2.7 - 5.5 m) 25x50
G, Q, S (4)
Q S. 37.24 -0.11 0.05 0.01 -0.11
Pie Cumple Cumple 0.7 45.0 N.P.(3) Cumple 45.0 Cumple
G, Q(5) N,M 59.61 -0.01 0.09 0.02 -0.11
G, Q, S (4)
Q S. 38.30 -0.02 0.01 -0.03 -0.07
Cabeza Cumple Cumple 0.5 46.5 N.P.(3) Cumple 46.5 Cumple
G, Q(5) N,M 61.78 -0.05 0.02 -0.04 -0.06
ENTREPISO (0 - 2.7 m) 25x50
G, Q, S(4) Q S. 39.25 -0.20 -0.07 -0.03 -0.07
Pie Cumple Cumple 0.5 47.4 N.P.(3) Cumple 47.4 Cumple
G, Q(5) N,M 62.70 -0.21 -0.08 -0.04 -0.06
Cabeza Cumple Cumple 2.0 49.3 N.P. (3)
Cumple 49.3 G, Q (5)
Q,N,M 67.05 0.41 0.24 -0.13 -0.25 Cumple
PB (-2.66 - 0 m) 25x50
Pie Cumple Cumple 2.0 49.8 N.P.(3) Cumple 49.8 G, Q(5) Q,N,M 67.95 -0.21 -0.07 -0.13 -0.25 Cumple
SUBSUELO 25x50 Arranque N.P.(1) N.P.(1) N.P.(2) 51.4 N.P.(1) Cumple 51.4 G, Q(5) N,M 67.95 -0.21 -0.07 -0.13 -0.25 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
1.2·PP+1.2·CM+1.6·Qa

1.8. C8

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 45.1 28.2 N.P.(3) Cumple 45.1 G, Q(4) Q,N,M 9.94 0.46 1.95 -2.27 -0.36 Cumple
P12 (32.9 - 35.7 m) 25x50
Pie Cumple Cumple 47.9 62.7 N.P.(3) Cumple 62.7 G, Q(4) Q,N,M 10.90 -0.45 -3.84 -2.27 -0.36 Cumple
32.9 m N.P.(1) N.P.(1) N.P.(2) 62.7 N.P.(1) Cumple 62.7 G, Q(4) N,M 10.90 -0.45 -3.84 -2.27 -0.36 Cumple
Cabeza Cumple Cumple 56.4 61.8 N.P.(3) Cumple 61.8 G, Q(4) Q,N,M 26.72 0.21 4.25 -2.78 -0.12 Cumple
P11 (30.1 - 32.9 m) 25x50
G, Q, S(5) Q S. 16.55 -0.21 -1.90 -1.77 -0.16
Pie Cumple Cumple 28.1 46.2 N.P. (3)
Cumple 46.2 Cumple
G, Q(4) N,M 27.68 -0.09 -2.85 -2.78 -0.12
30.1 m N.P. (1)
N.P. (1)
N.P. (2)
46.2 N.P. (1)
Cumple 46.2 G, Q (4)
N,M 27.68 -0.09 -2.85 -2.78 -0.12 Cumple
P10 (27.3 - 30.1 m) 25x50 Cabeza Cumple Cumple 9.5 33.4 N.P.(3) Cumple 33.4 G, Q(4) Q,N,M 37.38 0.22 1.45 -1.24 -0.26 Cumple
Pie Cumple Cumple 9.5 36.8 N.P.(3) Cumple 36.8 G, Q(4) Q,N,M 38.34 -0.45 -1.70 -1.24 -0.26 Cumple
Cabeza Cumple Cumple 11.3 45.3 N.P.(3) Cumple 45.3 G, Q(4) Q,N,M 47.48 0.56 2.03 -1.56 -0.35 Cumple
P9 (24.5 - 27.3 m) 25x50
Pie Cumple Cumple 11.3 44.6 N.P. (3)
Cumple 44.6 G, Q(4) Q,N,M 48.43 -0.34 -1.95 -1.56 -0.35 Cumple
Cabeza Cumple Cumple 10.0 49.3 N.P.(3) Cumple 49.3 G, Q(4) Q,N,M 58.18 0.18 1.91 -1.48 -0.17 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 10.0 49.6 N.P.(3) Cumple 49.6 G, Q(4) Q,N,M 59.14 -0.26 -1.87 -1.48 -0.17 Cumple
Cabeza Cumple Cumple 10.3 56.1 N.P.(3) Cumple 56.1 G, Q(4) Q,N,M 68.85 0.35 1.97 -1.58 -0.27 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 10.2 56.2 N.P.(3) Cumple 56.2 G, Q(4) Q,N,M 69.77 -0.31 -1.92 -1.58 -0.27 Cumple
Cabeza Cumple Cumple 9.7 62.3 N.P.(3) Cumple 62.3 G, Q(4) Q,N,M 79.63 0.30 1.94 -1.57 -0.25 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 9.6 62.5 N.P.(3) Cumple 62.5 G, Q(4) Q,N,M 80.55 -0.31 -1.90 -1.57 -0.25 Cumple
Cabeza Cumple Cumple 9.3 69.9 N.P.(3) Cumple 69.9 G, Q(4) Q,N,M 90.55 0.33 1.94 -1.57 -0.27 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 9.2 70.7 N.P.(3) Cumple 70.7 G, Q(4) Q,N,M 91.47 -0.33 -1.90 -1.57 -0.27 Cumple
Cabeza Cumple Cumple 8.8 79.2 N.P.(3) Cumple 79.2 G, Q(4) Q,N,M 101.66 0.34 1.93 -1.55 -0.28 Cumple
P4 (10.9 - 13.6 m) 25x50
Pie Cumple Cumple 8.8 80.0 N.P.(3) Cumple 80.0 G, Q(4) Q,N,M 102.57 -0.35 -1.87 -1.55 -0.28 Cumple
Cabeza Cumple Cumple 8.8 88.9 N.P.(3) Cumple 88.9 G, Q(4) Q,N,M 112.96 0.35 1.95 -1.60 -0.29 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 8.7 89.7 N.P.(3) Cumple 89.7 G, Q(4) Q,N,M 113.88 -0.37 -1.97 -1.60 -0.29 Cumple
Cabeza Cumple Cumple 6.6 98.7 N.P.(3) Cumple 98.7 G, Q(4) Q,N,M 124.51 0.37 1.71 -1.23 -0.32 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 6.6 99.6 N.P. (3)
Cumple 99.6 G, Q(4) Q,N,M 125.42 -0.41 -1.30 -1.23 -0.32 Cumple

Página 7
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

ENTREPISO (0 - 5.5 m) Diámetro 60 Cabeza Cumple Cumple 3.6 46.0 N.P.(3) Cumple 46.0 G, Q(4) Q,N,M 136.51 0.45 3.52 -1.09 -0.15 Cumple
Pie Cumple Cumple 3.5 47.5 N.P.(3) Cumple 47.5 G, Q(4) Q,N,M 140.96 -0.32 -2.22 -1.09 -0.15 Cumple
Cabeza Cumple Cumple 5.6 47.8 N.P.(3) Cumple 47.8 G, Q(4) Q,N,M 151.83 0.46 3.19 -1.77 -0.26 Cumple
PB (-2.66 - 0 m) Diámetro 60
Pie Cumple Cumple 5.6 48.4 N.P.(3) Cumple 48.4 G, Q(4) Q,N,M 153.88 -0.17 -1.08 -1.77 -0.26 Cumple
SUBSUELO Diámetro 60 Arranque N.P.(1) N.P.(1) N.P.(2) 48.4 N.P.(1) Cumple 48.4 G, Q(4) N,M 153.88 -0.17 -1.08 -1.77 -0.26 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+0.5·Qa+SY

1.9. C9

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 72.0 72.7 N.P.(3) Cumple 72.7 G, Q(4) Q,N,M 6.60 0.09 -4.04 3.44 0.57 Cumple
P12 (32.9 - 35.7 m) 25x50
Pie Cumple Cumple 72.9 87.2 N.P.(3) Cumple 87.2 G, Q(4) Q,N,M 7.55 1.55 4.73 3.44 0.57 Cumple
32.9 m N.P.(1) N.P.(1) N.P.(2) 87.2 N.P.(1) Cumple 87.2 G, Q(4) N,M 7.55 1.55 4.73 3.44 0.57 Cumple
P11 (30.1 - 32.9 m) 25x50 Cabeza Cumple Cumple 59.9 62.4 N.P.(3) Cumple 62.4 G, Q(4) Q,N,M 18.97 -2.23 -3.84 2.88 1.23 Cumple
Pie Cumple Cumple 59.0 52.5 N.P.(3) Cumple 59.0 G, Q(4) Q,N,M 19.92 0.90 3.51 2.88 1.23 Cumple
Cabeza Cumple Cumple 40.9 50.5 N.P.(3) Cumple 50.5 G, Q(4) Q,N,M 27.91 0.53 -3.13 2.51 -0.34 Cumple
P10 (27.3 - 30.1 m) 25x50
Pie Cumple Cumple 42.1 52.7 N.P.(3) Cumple 52.7 G, Q(4) Q,N,M 28.86 -0.33 3.27 2.51 -0.34 Cumple
Cabeza Cumple Cumple 19.9 56.5 N.P.(3) Cumple 56.5 G, Q(4) Q,N,M 36.35 0.11 -3.34 2.62 -0.05 Cumple
P9 (24.5 - 27.3 m) 25x50
Pie Cumple Cumple 19.8 57.9 N.P.(3) Cumple 57.9 G, Q(4) Q,N,M 37.31 -0.02 3.34 2.62 -0.05 Cumple
Cabeza Cumple Cumple 18.3 58.6 N.P. (3)
Cumple 58.6 G, Q(4) Q,N,M 45.19 0.01 -3.24 2.54 -0.02 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 18.2 59.8 N.P.(3) Cumple 59.8 G, Q(4) Q,N,M 46.14 -0.03 3.24 2.54 -0.02 Cumple
Cabeza Cumple Cumple 18.4 62.9 N.P.(3) Cumple 62.9 G, Q(4) Q,N,M 53.97 0.06 -3.28 2.68 -0.04 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 18.3 63.8 N.P.(3) Cumple 63.8 G, Q(4) Q,N,M 54.89 -0.04 3.28 2.68 -0.04 Cumple
Cabeza Cumple Cumple 17.3 66.3 N.P. (3)
Cumple 66.3 G, Q(4) Q,N,M 62.79 0.04 -3.21 2.63 -0.03 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 17.2 67.5 N.P.(3) Cumple 67.5 G, Q(4) Q,N,M 63.71 -0.04 3.25 2.63 -0.03 Cumple
Cabeza Cumple Cumple 16.5 70.8 N.P.(3) Cumple 70.8 G, Q(4) Q,N,M 71.66 0.04 -3.19 2.62 -0.04 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 16.4 71.7 N.P.(3) Cumple 71.7 G, Q(4) Q,N,M 72.58 -0.04 3.22 2.62 -0.04 Cumple
Cabeza Cumple Cumple 15.9 75.8 N.P. (3)
Cumple 75.8 G, Q(4) Q,N,M 80.60 0.04 -3.17 2.62 -0.04 Cumple
P4 (10.9 - 13.6 m) 25x50
Pie Cumple Cumple 15.8 77.2 N.P.(3) Cumple 77.2 G, Q(4) Q,N,M 81.52 -0.06 3.24 2.62 -0.04 Cumple
Cabeza Cumple Cumple 14.6 80.3 N.P.(3) Cumple 80.3 G, Q(4) Q,N,M 89.61 0.02 -3.10 2.49 -0.04 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 14.6 79.7 N.P.(3) Cumple 79.7 G, Q(4) Q,N,M 90.53 -0.09 3.01 2.49 -0.04 Cumple
Cabeza Cumple Cumple 16.4 87.9 N.P. (3)
Cumple 87.9 G, Q(4) Q,N,M 98.74 -0.02 -3.28 2.89 0.00 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 16.4 95.1 N.P.(3) Cumple 95.1 G, Q(4) Q,N,M 99.66 -0.02 3.81 2.89 0.00 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 95.1 N.P.(1) Cumple 95.1 G, Q(4) N,M 99.66 -0.02 3.81 2.89 0.00 Cumple
P1 (2.7 - 5.5 m) 25x50 Cabeza Cumple Cumple 5.0 85.0 N.P.(3) Cumple 85.0 G, Q(4) Q,N,M 107.73 0.05 -2.17 0.92 0.01 Cumple
Pie Cumple Cumple 5.0 85.8 N.P.(3) Cumple 85.8 G, Q(4) Q,N,M 108.68 0.09 0.16 0.92 0.01 Cumple
Cabeza Cumple Cumple 3.6 86.7 N.P.(3) Cumple 86.7 G, Q(4) Q,N,M 110.64 -0.11 0.38 0.66 0.05 Cumple
ENTREPISO (0 - 2.7 m) 25x50
Pie Cumple Cumple 3.6 87.6 N.P.(3) Cumple 87.6 G, Q(4) Q,N,M 111.56 0.02 2.00 0.66 0.05 Cumple
Cabeza Cumple Cumple 10.3 98.4 N.P.(3) Cumple 98.4 G, Q(4) Q,N,M 119.83 0.19 -3.42 2.24 -0.10 Cumple
PB (-2.66 - 0 m) 25x50
Pie Cumple Cumple 10.2 92.1 N.P.(3) Cumple 92.1 G, Q(4) Q,N,M 120.74 -0.04 1.97 2.24 -0.10 Cumple
SUBSUELO 25x50 Arranque N.P. (1)
N.P. (1)
N.P. (2)
95.2 N.P. (1)
Cumple 95.2 G, Q(4) N,M 120.74 -0.04 1.97 2.24 -0.10 Cumple

Página 8
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.10. C10

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 7.4 3.1 N.P.(3) Cumple 7.4 G, Q(4) Q,N,M 1.45 -0.30 0.11 -0.07 0.43 Cumple
TANQUE (38.2 - 40.7 m) 25x50
Pie Cumple Cumple 7.7 4.4 N.P.(3) Cumple 7.7 G, Q(4) Q,N,M 2.29 0.68 -0.03 -0.07 0.43 Cumple
Cabeza Cumple Cumple 15.2 7.5 N.P.(3) Cumple 15.2 G, Q(4) Q,N,M 4.48 -1.00 -0.07 0.05 0.89 Cumple
P13 (35.7 - 38.2 m) 25x50 G, Q, S(5) Q S. 3.23 0.67 0.02 0.02 0.56
Pie Cumple Cumple 8.5 8.1 N.P. (3)
Cumple 8.5 Cumple
G, Q(4) N,M 5.32 1.01 0.05 0.05 0.89
Cabeza Cumple Cumple 5.7 8.7 N.P. (3)
Cumple 8.7 G, Q (4)
Q,N,M 8.18 -0.85 -0.01 0.01 0.63 Cumple
P12 (32.9 - 35.7 m) 25x50
Pie Cumple Cumple 5.6 8.8 N.P.(3) Cumple 8.8 G, Q(4) Q,N,M 9.13 0.76 0.03 0.01 0.63 Cumple
Cabeza Cumple Cumple 5.1 10.2 N.P.(3) Cumple 10.2 G, Q(4) Q,N,M 11.63 -0.72 -0.02 0.02 0.59 Cumple
P11 (30.1 - 32.9 m) 25x50
Pie Cumple Cumple 5.1 11.1 N.P.(3) Cumple 11.1 G, Q(4) Q,N,M 12.59 0.79 0.04 0.02 0.59 Cumple
Cabeza Cumple Cumple 5.4 13.0 N.P.(3) Cumple 13.0 G, Q(4) Q,N,M 15.29 -0.83 -0.01 0.02 0.64 Cumple
P10 (27.3 - 30.1 m) 25x50
Pie Cumple Cumple 5.3 13.6 N.P.(3) Cumple 13.6 G, Q(4) Q,N,M 16.25 0.81 0.03 0.02 0.64 Cumple
Cabeza Cumple Cumple 4.9 15.3 N.P.(3) Cumple 15.3 G, Q(4) Q,N,M 18.94 -0.77 -0.01 0.02 0.61 Cumple
P9 (24.5 - 27.3 m) 25x50
Pie Cumple Cumple 4.9 16.0 N.P.(3) Cumple 16.0 G, Q(4) Q,N,M 19.90 0.78 0.04 0.02 0.61 Cumple
Cabeza Cumple Cumple 4.7 17.9 N.P.(3) Cumple 17.9 G, Q(4) Q,N,M 22.62 -0.76 -0.01 0.02 0.59 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 4.6 18.6 N.P.(3) Cumple 18.6 G, Q(4) Q,N,M 23.58 0.75 0.04 0.02 0.59 Cumple
Cabeza Cumple Cumple 4.6 20.5 N.P.(3) Cumple 20.5 G, Q(4) Q,N,M 26.33 -0.74 -0.01 0.02 0.60 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 4.6 21.1 N.P.(3) Cumple 21.1 G, Q(4) Q,N,M 27.25 0.73 0.05 0.02 0.60 Cumple
Cabeza Cumple Cumple 4.3 23.1 N.P.(3) Cumple 23.1 G, Q(4) Q,N,M 30.02 -0.71 -0.01 0.02 0.58 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 4.3 23.8 N.P.(3) Cumple 23.8 G, Q(4) Q,N,M 30.94 0.70 0.05 0.02 0.58 Cumple
Cabeza Cumple Cumple 4.0 25.8 N.P.(3) Cumple 25.8 G, Q(4) Q,N,M 33.75 -0.68 -0.01 0.02 0.55 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 4.0 26.4 N.P.(3) Cumple 26.4 G, Q(4) Q,N,M 34.67 0.67 0.05 0.02 0.55 Cumple
Cabeza Cumple Cumple 3.7 28.5 N.P.(3) Cumple 28.5 G, Q(4) Q,N,M 37.51 -0.65 0.00 0.02 0.52 Cumple
P4 (10.9 - 13.6 m) 25x50
Pie Cumple Cumple 3.7 29.2 N.P.(3) Cumple 29.2 G, Q(4) Q,N,M 38.43 0.64 0.05 0.02 0.52 Cumple
Cabeza Cumple Cumple 3.4 31.3 N.P.(3) Cumple 31.3 G, Q(4) Q,N,M 41.31 -0.61 0.00 0.02 0.49 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 3.4 31.9 N.P.(3) Cumple 31.9 G, Q(4) Q,N,M 42.23 0.58 0.04 0.02 0.49 Cumple
Cabeza Cumple Cumple 3.4 34.1 N.P.(3) Cumple 34.1 G, Q(4) Q,N,M 45.14 -0.57 -0.01 0.03 0.49 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 3.3 34.9 N.P.(3) Cumple 34.9 G, Q(4) Q,N,M 46.06 0.64 0.06 0.03 0.49 Cumple
P1 (2.7 - 5.5 m) 25x50 Cabeza Cumple Cumple 1.7 37.0 N.P.(3) Cumple 37.0 G, Q(4) Q,N,M 49.03 -0.45 0.01 0.02 0.25 Cumple
Pie Cumple Cumple 1.6 37.5 N.P.(3) Cumple 37.5 G, Q(4) Q,N,M 49.99 0.18 0.05 0.02 0.25 Cumple
Cabeza Cumple Cumple 1.2 38.9 N.P.(3) Cumple 38.9 G, Q(4) Q,N,M 52.05 -0.09 0.01 0.03 0.18 Cumple
ENTREPISO (0 - 2.7 m) 25x50
Pie Cumple Cumple 1.2 39.9 N.P.(3) Cumple 39.9 G, Q(4) Q,N,M 52.97 0.35 0.07 0.03 0.18 Cumple
PB (-2.66 - 0 m) 25x50 Cabeza Cumple Cumple 1.7 42.3 N.P.(3) Cumple 42.3 G, Q(4) Q,N,M 56.10 -0.42 0.01 0.02 0.27 Cumple
Pie Cumple Cumple 1.7 42.9 N.P.(3) Cumple 42.9 G, Q(4) Q,N,M 57.01 0.23 0.05 0.02 0.27 Cumple
SUBSUELO 25x50 Arranque N.P.(1) N.P.(1) N.P.(2) 42.9 N.P.(1) Cumple 42.9 G, Q(4) N,M 57.01 0.23 0.05 0.02 0.27 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+0.5·Qa+SY

Página 9
Comprobaciones E.L.U.
PROYECTO HORMIGON

1.11. C11

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 24.5 15.9 N.P.(3) Cumple 24.5 G, Q(4) Q,N,M 6.57 -0.51 0.76 -0.49 2.16 Cumple
TANQUE (38.2 - 40.7 m) 20x60
Pie Cumple Cumple 47.1 28.4 N.P.(3) Cumple 47.1 G, Q(4) Q,N,M 7.38 4.36 -0.35 -0.49 2.16 Cumple
Cabeza Cumple Cumple 68.1 35.8 N.P.(3) Cumple 68.1 G, Q(4) Q,N,M 16.93 -5.69 -0.28 0.17 3.60 Cumple
P13 (35.7 - 38.2 m) 20x60
Pie Cumple Cumple 33.8 21.8 N.P.(3) Cumple 33.8 G, Q(4) Q,N,M 17.74 2.41 0.10 0.17 3.60 Cumple
35.7 m N.P.(1) N.P.(1) N.P.(2) 21.8 N.P.(1) Cumple 21.8 G, Q(4) N,M 17.74 2.41 0.10 0.17 3.60 Cumple
G, Q, S(5) Q S. 11.76 -0.08 0.04 -0.02 0.23
Cabeza Cumple Cumple 2.0 17.3 N.P.(3) Cumple 17.3 Cumple
P12 (32.9 - 35.7 m) 20x60 G, Q(4) N,M 21.37 0.23 0.08 -0.04 0.12
G, Q, S (5)
Q S. 12.71 0.51 -0.01 -0.02 0.23
Pie Cumple Cumple 2.0 18.5 N.P.(3) Cumple 18.5 Cumple
G, Q(4) N,M 22.29 0.53 -0.02 -0.04 0.12
Cabeza Cumple Cumple 7.2 22.6 N.P.(3) Cumple 22.6 G, Q(4) Q,N,M 25.82 -1.13 -0.02 0.02 0.81 Cumple
P11 (30.1 - 32.9 m) 20x60
Pie Cumple Cumple 7.1 23.0 N.P.(3) Cumple 23.0 G, Q(4) Q,N,M 26.74 0.94 0.02 0.02 0.81 Cumple
Cabeza Cumple Cumple 5.2 25.5 N.P.(3) Cumple 25.5 G, Q(4) Q,N,M 30.33 -0.73 0.02 0.00 0.61 Cumple
P10 (27.3 - 30.1 m) 20x60
Pie Cumple Cumple 5.1 26.3 N.P.(3) Cumple 26.3 G, Q(4) Q,N,M 31.25 0.81 0.01 0.00 0.61 Cumple
Cabeza Cumple Cumple 5.3 29.4 N.P.(3) Cumple 29.4 G, Q(4) Q,N,M 34.87 -0.83 0.00 0.00 0.64 Cumple
P9 (24.5 - 27.3 m) 20x60
Pie Cumple Cumple 5.3 30.1 N.P.(3) Cumple 30.1 G, Q(4) Q,N,M 35.79 0.80 0.01 0.00 0.64 Cumple
Cabeza Cumple Cumple 4.7 33.1 N.P.(3) Cumple 33.1 G, Q(4) Q,N,M 39.38 -0.74 0.01 0.00 0.58 Cumple
P8 (21.7 - 24.5 m) 20x60
Pie Cumple Cumple 4.7 33.9 N.P.(3) Cumple 33.9 G, Q(4) Q,N,M 40.30 0.74 0.01 0.00 0.58 Cumple
Cabeza Cumple Cumple 4.6 36.8 N.P.(3) Cumple 36.8 G, Q(4) Q,N,M 43.90 -0.73 0.01 0.00 0.59 Cumple
P7 (19 - 21.7 m) 20x60
Pie Cumple Cumple 4.6 37.5 N.P.(3) Cumple 37.5 G, Q(4) Q,N,M 44.78 0.71 0.01 0.00 0.59 Cumple
Cabeza Cumple Cumple 4.1 40.5 N.P.(3) Cumple 40.5 G, Q(4) Q,N,M 48.36 -0.66 0.01 0.00 0.54 Cumple
P6 (16.3 - 19 m) 20x60
Pie Cumple Cumple 4.1 41.3 N.P.(3) Cumple 41.3 G, Q(4) Q,N,M 49.24 0.65 0.01 0.00 0.54 Cumple
Cabeza Cumple Cumple 3.6 44.4 N.P.(3) Cumple 44.4 G, Q(4) Q,N,M 52.79 -0.61 0.01 0.00 0.49 Cumple
P5 (13.6 - 16.3 m) 20x60
Pie Cumple Cumple 3.6 45.2 N.P.(3) Cumple 45.2 G, Q(4) Q,N,M 53.67 0.59 0.02 0.00 0.49 Cumple
Cabeza Cumple Cumple 3.1 48.3 N.P.(3) Cumple 48.3 G, Q(4) Q,N,M 57.18 -0.54 0.01 0.00 0.43 Cumple
P4 (10.9 - 13.6 m) 20x60
Pie Cumple Cumple 3.1 49.0 N.P.(3) Cumple 49.0 G, Q(4) Q,N,M 58.06 0.51 0.02 0.00 0.43 Cumple
Cabeza Cumple Cumple 2.6 52.2 N.P.(3) Cumple 52.2 G, Q(4) Q,N,M 61.53 -0.48 0.01 0.00 0.36 Cumple
P3 (8.2 - 10.9 m) 20x60
Pie Cumple Cumple 2.6 53.0 N.P.(3) Cumple 53.0 G, Q(4) Q,N,M 62.41 0.41 0.01 0.00 0.36 Cumple
Cabeza Cumple Cumple 2.4 56.1 N.P.(3) Cumple 56.1 G, Q(4) Q,N,M 65.81 -0.42 0.01 0.00 0.34 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 2.4 57.0 N.P.(3) Cumple 57.0 G, Q(4) Q,N,M 66.70 0.42 0.02 0.00 0.34 Cumple
G, Q(4) Q 70.05 -0.20 0.02 0.00 0.08
Cabeza Cumple Cumple 0.6 81.2 N.P.(3) Cumple 81.2 Cumple
G, Q, S(6) N,M S. 44.07 -0.07 0.03 0.00 0.03
ENTREPISO (0 - 5.5 m) 20x60
G, Q(4) Q 71.94 0.23 0.02 0.00 0.08
Pie Cumple Cumple 0.6 95.3 N.P.(3) Cumple 95.3 Cumple
G, Q, S(6) N,M S. 46.04 0.07 0.03 0.00 0.03
0m N.P.(1) N.P.(1) N.P.(2) 95.3 N.P.(1) Cumple 95.3 G, Q, S(6) N,M S. 46.04 0.07 0.03 0.00 0.03 Cumple
G, Q, S(5) Q S. 46.02 -0.10 0.02 0.00 0.21
Cabeza Cumple Cumple 1.4 64.9 N.P. (3)
Cumple 64.9 Cumple
PB (-2.66 - 0 m) 20x60 G, Q(4) N,M 75.43 -0.26 0.02 0.00 0.18
G, Q, S(5) Q S. 46.92 0.41 0.03 0.00 0.21
Pie Cumple Cumple 1.4 65.7 N.P.(3) Cumple 65.7 Cumple
G, Q(4) N,M 76.30 0.17 0.03 0.00 0.18
SUBSUELO 20x60 Arranque N.P. (1)
N.P. (1)
N.P. (2)
65.7 N.P. (1)
Cumple 65.7 G, Q (4)
N,M 76.30 0.17 0.03 0.00 0.18 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+0.5·Qa+SY
(6)
1.245·PP+1.245·CM+0.5·Qa+SX

Página 10
Comprobaciones E.L.U.
PROYECTO HORMIGON

1.12. C12

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 40.7 53.4 N.P.(3) Cumple 53.4 G, Q(4) Q,N,M 4.97 0.24 -3.00 1.91 0.61 Cumple
TANQUE (38.2 - 40.7 m) 25x50
Pie Cumple Cumple 39.2 25.7 N.P. (3)
Cumple 39.2 G, Q(4) Q,N,M 5.81 1.61 1.31 1.91 0.61 Cumple
Cabeza Cumple Cumple 30.6 30.2 N.P.(3) Cumple 30.6 G, Q(4) Q,N,M 12.06 -2.57 1.23 -0.73 1.62 Cumple
P13 (35.7 - 38.2 m) 25x50
Pie Cumple Cumple 15.3 13.5 N.P.(3) Cumple 15.3 G, Q(4) Q,N,M 12.90 1.08 -0.41 -0.73 1.62 Cumple
35.7 m N.P.(1) N.P.(1) N.P.(2) 13.5 N.P.(1) Cumple 13.5 G, Q(4) N,M 12.90 1.08 -0.41 -0.73 1.62 Cumple
G, S(5) Q S. 7.23 0.55 -0.10 0.05 -0.40
Cabeza Cumple Cumple 3.2 12.2 N.P. (3)
Cumple 12.2 Cumple
P12 (32.9 - 35.7 m) 25x50 G, Q(4) N,M 16.45 0.23 -0.31 0.16 -0.07
G, S (5)
Q S. 8.22 -0.47 0.03 0.05 -0.40
Pie Cumple Cumple 3.2 12.8 N.P.(3) Cumple 12.8 Cumple
G, Q(4) N,M 17.41 0.06 0.10 0.16 -0.07
G, Q, S(6) Q S. 11.69 -0.56 0.08 -0.03 0.50
Cabeza Cumple Cumple 3.8 15.6 N.P.(3) Cumple 15.6 Cumple
G, Q(4) N,M 20.78 -0.34 0.14 -0.07 0.27
P11 (30.1 - 32.9 m) 25x50
G, Q, S(6) Q S. 12.68 0.71 -0.01 -0.03 0.50
Pie Cumple Cumple 3.8 16.3 N.P.(3) Cumple 16.3 Cumple
G, Q(4) N,M 21.73 0.35 -0.05 -0.07 0.27
G, Q, S (6)
Q S. 14.62 -0.46 0.01 0.00 0.40
Cabeza Cumple Cumple 3.0 18.8 N.P.(3) Cumple 18.8 Cumple
G, Q(4) N,M 25.30 -0.27 0.01 -0.01 0.23
P10 (27.3 - 30.1 m) 25x50
G, Q, S (6)
Q S. 15.61 0.56 0.00 0.00 0.40
Pie Cumple Cumple 2.9 19.6 N.P.(3) Cumple 19.6 Cumple
G, Q(4) N,M 26.25 0.30 0.00 -0.01 0.23
G, Q, S(6) Q S. 17.50 -0.48 0.03 -0.01 0.44
Cabeza Cumple Cumple 3.2 22.2 N.P.(3) Cumple 22.2 Cumple
G, Q(4) N,M 29.78 -0.28 0.05 -0.02 0.22
P9 (24.5 - 27.3 m) 25x50
G, Q, S (6)
Q S. 18.49 0.63 0.01 -0.01 0.44
Pie Cumple Cumple 3.1 22.9 N.P.(3) Cumple 22.9 Cumple
G, Q(4) N,M 30.74 0.29 -0.01 -0.02 0.22
G, Q, S (6)
Q S. 20.45 -0.36 0.03 -0.01 0.32
Cabeza Cumple Cumple 2.2 25.5 N.P.(3) Cumple 25.5 Cumple
G, Q(4) N,M 34.22 -0.27 0.04 -0.02 0.21
P8 (21.7 - 24.5 m) 25x50
G, Q, S(6) Q S. 21.26 0.51 0.00 -0.01 0.33
Pie Cumple Cumple 2.3 26.2 N.P.(3) Cumple 26.2 Cumple
G, Q(4) N,M 35.18 0.28 -0.01 -0.02 0.21
G, Q, S(6) Q S. 23.29 -0.43 0.02 -0.01 0.37
Cabeza Cumple Cumple 2.6 28.8 N.P.(3) Cumple 28.8 Cumple
G, Q(4) N,M 38.63 -0.28 0.04 -0.02 0.23
P7 (19 - 21.7 m) 25x50
G, Q, S (6)
Q S. 24.07 0.52 0.01 -0.01 0.38
Pie Cumple Cumple 2.6 29.5 N.P.(3) Cumple 29.5 Cumple
G, Q(4) N,M 39.55 0.28 -0.01 -0.02 0.23
G, Q, S(6) Q S. 26.31 -0.47 0.02 -0.01 0.36
Cabeza Cumple Cumple 2.4 32.1 N.P.(3) Cumple 32.1 Cumple
G, Q(4) N,M 42.94 -0.26 0.05 -0.02 0.22
P6 (16.3 - 19 m) 25x50
G, Q, S(6) Q S. 27.09 0.44 0.00 -0.01 0.35
Pie Cumple Cumple 2.4 32.8 N.P.(3) Cumple 32.8 Cumple
G, Q(4) N,M 43.86 0.27 0.00 -0.02 0.22
G, Q, S (6)
Q S. 29.03 -0.46 0.02 -0.01 0.38
Cabeza Cumple Cumple 2.5 35.3 N.P.(3) Cumple 35.3 Cumple
G, Q(4) N,M 47.19 -0.27 0.05 -0.02 0.22
P5 (13.6 - 16.3 m) 25x50
G, Q, S (6)
Q S. 29.98 0.47 0.01 -0.01 0.38
Pie Cumple Cumple 2.5 36.1 N.P.(3) Cumple 36.1 Cumple
G, Q(4) N,M 48.10 0.26 0.00 -0.02 0.22
G, Q, S(6) Q S. 31.57 -0.38 0.03 -0.01 0.36
Cabeza Cumple Cumple 2.4 38.6 N.P.(3) Cumple 38.6 Cumple
G, Q(4) N,M 51.34 -0.26 0.05 -0.02 0.21
P4 (10.9 - 13.6 m) 25x50
G, Q, S (6)
Q S. 32.53 0.51 0.01 -0.01 0.36
Pie Cumple Cumple 2.3 39.3 N.P.(3) Cumple 39.3 Cumple
G, Q(4) N,M 52.26 0.25 0.00 -0.02 0.21
G, Q, S(6) Q S. 34.18 -0.29 0.04 0.01 0.43
Cabeza Cumple Cumple 2.8 41.7 N.P.(3) Cumple 41.7 Cumple
G, Q(4) N,M 55.39 -0.28 0.05 -0.02 0.20
P3 (8.2 - 10.9 m) 25x50
G, Q, S(6) Q S. 35.13 0.77 0.06 0.01 0.43
Pie Cumple Cumple 2.8 42.4 N.P.(3) Cumple 42.4 Cumple
G, Q(4) N,M 56.31 0.20 0.00 -0.02 0.20
P2 (5.5 - 8.2 m) 25x50 Cabeza Cumple Cumple 1.8 44.8 N.P. (3)
Cumple 44.8 G, Q (4)
Q,N,M 59.32 -0.34 0.04 -0.01 0.29 Cumple

Página 11
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Pie Cumple Cumple 1.8 45.5 N.P.(3) Cumple 45.5 G, Q(4) Q,N,M 60.24 0.36 0.02 -0.01 0.29 Cumple
G, Q, S(6) Q S. 39.15 -0.25 0.02 0.00 0.21
Cabeza Cumple Cumple 1.3 47.8 N.P. (3)
Cumple 47.8 Cumple
G, Q(4) N,M 63.12 -0.20 0.05 -0.02 0.13
P1 (2.7 - 5.5 m) 25x50
G, Q, S (6)
Q S. 40.14 0.29 0.02 0.00 0.21
Pie Cumple Cumple 1.3 48.6 N.P.(3) Cumple 48.6 Cumple
G, Q(4) N,M 64.07 0.13 0.00 -0.02 0.13
Cabeza Cumple Cumple 1.1 50.2 N.P. (3)
Cumple 50.2 G, Q, S (7)
Q S. 42.14 -0.10 0.04 -0.01 0.18 Cumple
G, Q(4) N,M 66.47 -0.12 0.06 -0.02 0.15
ENTREPISO (0 - 2.7 m) 25x50
G, Q, S(7) Q S. 43.09 0.34 0.03 -0.01 0.18
Pie Cumple Cumple 1.1 51.1 N.P.(3) Cumple 51.1 Cumple
G, Q(4) N,M 67.39 0.26 0.02 -0.02 0.15
G, Q, S (7)
Q S. 44.31 -0.04 0.04 0.00 0.20
Cabeza Cumple Cumple 1.2 53.0 N.P.(3) Cumple 53.0 Cumple
G, Q(4) N,M 69.96 -0.17 0.05 -0.01 0.14
PB (-2.66 - 0 m) 25x50
G, Q, S (7)
Q S. 45.31 0.44 0.05 0.01 0.20
Pie Cumple Cumple 1.2 53.7 N.P.(3) Cumple 53.7 Cumple
G, Q(4) N,M 70.86 0.15 0.03 -0.01 0.14
SUBSUELO 25x50 Arranque N.P.(1) N.P.(1) N.P.(2) 53.7 N.P.(1) Cumple 53.7 G, Q(4) N,M 70.86 0.15 0.03 -0.01 0.14 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+SY
(6)
1.245·PP+1.245·CM+0.5·Qa-SY
(7)
1.245·PP+1.245·CM+0.5·Qa+SY

1.13. C13

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 40.2 36.1 N.P.(3) Cumple 40.2 G, Q(4) Q,N,M 4.21 0.18 -2.10 1.94 -0.21 Cumple
TANQUE (38.2 - 40.7 m) 25x50
Pie Cumple Cumple 40.3 38.1 N.P.(3) Cumple 40.3 G, Q(4) Q,N,M 5.06 -0.29 2.26 1.94 -0.21 Cumple
Cabeza Cumple Cumple 38.1 27.4 N.P.(3) Cumple 38.1 G, Q(4) Q,N,M 9.88 0.27 -1.96 1.89 -0.22 Cumple
P13 (35.7 - 38.2 m) 25x50
Pie Cumple Cumple 38.7 32.1 N.P.(3) Cumple 38.7 G, Q(4) Q,N,M 10.72 -0.23 2.30 1.89 -0.22 Cumple
Cabeza Cumple Cumple 36.1 33.6 N.P. (3)
Cumple 36.1 G, Q(4) Q,N,M 16.36 0.16 -2.35 1.84 -0.14 Cumple
P12 (32.9 - 35.7 m) 25x50
Pie Cumple Cumple 35.5 35.3 N.P.(3) Cumple 35.5 G, Q(4) Q,N,M 17.32 -0.19 2.34 1.84 -0.14 Cumple
G, Q, S(5) Q S. 14.27 0.23 -1.47 1.16 -0.18
Cabeza Cumple Cumple 18.4 37.5 N.P.(3) Cumple 37.5 Cumple
P11 (30.1 - 32.9 m) 25x50 G, Q(4) N,M 22.89 0.24 -2.29 1.81 -0.17
Pie Cumple Cumple 15.1 38.6 N.P.(3) Cumple 38.6 G, Q(4) Q,N,M 23.84 -0.20 2.32 1.81 -0.17 Cumple
Cabeza Cumple Cumple 14.4 39.8 N.P.(3) Cumple 39.8 G, Q(4) Q,N,M 29.41 0.24 -2.30 1.81 -0.18 Cumple
P10 (27.3 - 30.1 m) 25x50
Pie Cumple Cumple 14.3 40.7 N.P.(3) Cumple 40.7 G, Q(4) Q,N,M 30.37 -0.21 2.32 1.81 -0.18 Cumple
Cabeza Cumple Cumple 13.8 42.2 N.P. (3)
Cumple 42.2 G, Q(4) Q,N,M 35.92 0.23 -2.28 1.80 -0.17 Cumple
P9 (24.5 - 27.3 m) 25x50
Pie Cumple Cumple 13.7 43.2 N.P.(3) Cumple 43.2 G, Q(4) Q,N,M 36.88 -0.21 2.31 1.80 -0.17 Cumple
Cabeza Cumple Cumple 13.0 44.8 N.P.(3) Cumple 44.8 G, Q(4) Q,N,M 42.43 0.22 -2.26 1.77 -0.17 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 12.9 45.4 N.P.(3) Cumple 45.4 G, Q(4) Q,N,M 43.38 -0.20 2.26 1.77 -0.17 Cumple
Cabeza Cumple Cumple 13.2 48.0 N.P.(3) Cumple 48.0 G, Q(4) Q,N,M 48.95 0.20 -2.27 1.86 -0.16 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 13.1 48.7 N.P.(3) Cumple 48.7 G, Q(4) Q,N,M 49.86 -0.19 2.29 1.86 -0.16 Cumple
Cabeza Cumple Cumple 12.5 51.0 N.P. (3)
Cumple 51.0 G, Q(4) Q,N,M 55.44 0.18 -2.23 1.84 -0.15 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 12.5 52.0 N.P.(3) Cumple 52.0 G, Q(4) Q,N,M 56.36 -0.17 2.27 1.84 -0.15 Cumple
Cabeza Cumple Cumple 12.1 54.4 N.P.(3) Cumple 54.4 G, Q(4) Q,N,M 61.96 0.16 -2.22 1.82 -0.13 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 12.0 55.3 N.P.(3) Cumple 55.3 G, Q(4) Q,N,M 62.88 -0.15 2.25 1.82 -0.13 Cumple
P4 (10.9 - 13.6 m) 25x50 Cabeza Cumple Cumple 11.7 57.8 N.P. (3)
Cumple 57.8 G, Q(4) Q,N,M 68.50 0.13 -2.20 1.82 -0.11 Cumple

Página 12
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Pie Cumple Cumple 11.6 59.0 N.P.(3) Cumple 59.0 G, Q(4) Q,N,M 69.42 -0.13 2.26 1.82 -0.11 Cumple
Cabeza Cumple Cumple 11.0 61.5 N.P.(3) Cumple 61.5 G, Q(4) Q,N,M 75.08 0.08 -2.16 1.76 -0.09 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 10.9 62.0 N.P.(3) Cumple 62.0 G, Q(4) Q,N,M 76.00 -0.14 2.16 1.76 -0.09 Cumple
Cabeza Cumple Cumple 11.6 66.1 N.P. (3)
Cumple 66.1 G, Q(4) Q,N,M 81.74 -0.01 -2.23 1.92 0.00 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 11.6 69.1 N.P.(3) Cumple 69.1 G, Q(4) Q,N,M 82.66 0.00 2.47 1.92 0.00 Cumple
Cabeza Cumple Cumple 7.3 68.4 N.P.(3) Cumple 68.4 G, Q(4) Q,N,M 88.40 0.04 -1.89 1.24 0.00 Cumple
P1 (2.7 - 5.5 m) 25x50
Pie Cumple Cumple 7.3 69.2 N.P.(3) Cumple 69.2 G, Q(4) Q,N,M 89.36 0.04 1.27 1.24 0.00 Cumple
Cabeza Cumple Cumple 7.5 71.8 N.P.(3) Cumple 71.8 G, Q(4) Q,N,M 93.01 -0.09 -1.15 1.30 0.09 Cumple
ENTREPISO (0 - 2.7 m) 25x50
Pie Cumple Cumple 7.5 72.6 N.P.(3) Cumple 72.6 G, Q(4) Q,N,M 93.93 0.13 2.03 1.30 0.09 Cumple
Cabeza Cumple Cumple 7.8 77.2 N.P.(3) Cumple 77.2 G, Q(4) Q,N,M 99.73 0.01 -2.11 1.39 0.02 Cumple
PB (-2.66 - 0 m) 25x50
Pie Cumple Cumple 7.8 78.0 N.P.(3) Cumple 78.0 G, Q(4) Q,N,M 100.63 0.06 1.23 1.39 0.02 Cumple
SUBSUELO 25x50 Arranque N.P.(1) N.P.(1) N.P.(2) 78.0 N.P.(1) Cumple 78.0 G, Q(4) N,M 100.63 0.06 1.23 1.39 0.02 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+0.5·Qa+SX

1.14. C14

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 39.4 35.4 N.P.(3) Cumple 39.4 G, Q(4) Q,N,M 4.07 -0.13 -2.05 1.90 0.16 Cumple
TANQUE (38.2 - 40.7 m) 25x50
Pie Cumple Cumple 39.5 37.5 N.P.(3) Cumple 39.5 G, Q(4) Q,N,M 4.92 0.24 2.21 1.90 0.16 Cumple
Cabeza Cumple Cumple 37.8 27.0 N.P.(3) Cumple 37.8 G, Q(4) Q,N,M 9.56 -0.27 -1.93 1.87 0.20 Cumple
P13 (35.7 - 38.2 m) 25x50
Pie Cumple Cumple 38.4 31.5 N.P.(3) Cumple 38.4 G, Q(4) Q,N,M 10.40 0.18 2.28 1.87 0.20 Cumple
Cabeza Cumple Cumple 36.1 33.3 N.P.(3) Cumple 36.1 G, Q(4) Q,N,M 15.88 -0.14 -2.34 1.83 0.13 Cumple
P12 (32.9 - 35.7 m) 25x50
Pie Cumple Cumple 35.6 33.8 N.P.(3) Cumple 35.6 G, Q(4) Q,N,M 16.84 0.18 2.33 1.83 0.13 Cumple
Cabeza Cumple Cumple 32.3 36.9 N.P.(3) Cumple 36.9 G, Q(4) Q,N,M 22.27 -0.18 -2.29 1.80 0.15 Cumple
P11 (30.1 - 32.9 m) 25x50
Pie Cumple Cumple 15.0 37.7 N.P.(3) Cumple 37.7 G, Q(4) Q,N,M 23.22 0.21 2.31 1.80 0.15 Cumple
Cabeza Cumple Cumple 14.4 39.2 N.P.(3) Cumple 39.2 G, Q(4) Q,N,M 28.66 -0.14 -2.28 1.80 0.12 Cumple
P10 (27.3 - 30.1 m) 25x50
Pie Cumple Cumple 14.3 39.8 N.P.(3) Cumple 39.8 G, Q(4) Q,N,M 29.62 0.17 2.30 1.80 0.12 Cumple
Cabeza Cumple Cumple 13.7 41.6 N.P.(3) Cumple 41.6 G, Q(4) Q,N,M 35.07 -0.15 -2.27 1.79 0.12 Cumple
P9 (24.5 - 27.3 m) 25x50
Pie Cumple Cumple 13.7 42.4 N.P.(3) Cumple 42.4 G, Q(4) Q,N,M 36.02 0.16 2.30 1.79 0.12 Cumple
Cabeza Cumple Cumple 13.0 44.2 N.P.(3) Cumple 44.2 G, Q(4) Q,N,M 41.49 -0.13 -2.25 1.76 0.10 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 12.9 44.7 N.P.(3) Cumple 44.7 G, Q(4) Q,N,M 42.44 0.13 2.25 1.76 0.10 Cumple
Cabeza Cumple Cumple 13.1 47.2 N.P.(3) Cumple 47.2 G, Q(4) Q,N,M 47.92 -0.13 -2.26 1.85 0.10 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 13.1 47.9 N.P.(3) Cumple 47.9 G, Q(4) Q,N,M 48.84 0.13 2.28 1.85 0.10 Cumple
Cabeza Cumple Cumple 12.5 50.2 N.P.(3) Cumple 50.2 G, Q(4) Q,N,M 54.34 -0.10 -2.21 1.82 0.08 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 12.4 51.1 N.P.(3) Cumple 51.1 G, Q(4) Q,N,M 55.26 0.10 2.25 1.82 0.08 Cumple
Cabeza Cumple Cumple 12.0 53.6 N.P.(3) Cumple 53.6 G, Q(4) Q,N,M 60.77 -0.09 -2.20 1.81 0.07 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 12.0 54.5 N.P.(3) Cumple 54.5 G, Q(4) Q,N,M 61.69 0.08 2.24 1.81 0.07 Cumple
Cabeza Cumple Cumple 11.6 56.9 N.P.(3) Cumple 56.9 G, Q(4) Q,N,M 67.23 -0.07 -2.18 1.80 0.04 Cumple
P4 (10.9 - 13.6 m) 25x50
Pie Cumple Cumple 11.5 57.9 N.P.(3) Cumple 57.9 G, Q(4) Q,N,M 68.15 0.04 2.23 1.80 0.04 Cumple
Cabeza Cumple Cumple 11.1 60.6 N.P.(3) Cumple 60.6 G, Q(4) Q,N,M 73.71 -0.06 -2.15 1.77 0.01 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 11.1 61.5 N.P.(3) Cumple 61.5 G, Q(4) Q,N,M 74.62 -0.03 2.19 1.77 0.01 Cumple

Página 13
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 10.9 64.4 N.P.(3) Cumple 64.4 G, Q(4) Q,N,M 80.19 -0.08 -2.14 1.78 0.05 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 10.8 65.8 N.P.(3) Cumple 65.8 G, Q(4) Q,N,M 81.11 0.05 2.23 1.78 0.05 Cumple
P1 (2.7 - 5.5 m) 25x50 Cabeza Cumple Cumple 9.6 68.1 N.P.(3) Cumple 68.1 G, Q(4) Q,N,M 86.70 0.05 -2.07 1.62 -0.03 Cumple
Pie Cumple Cumple 9.6 68.6 N.P.(3) Cumple 68.6 G, Q(4) Q,N,M 87.66 -0.03 2.06 1.62 -0.03 Cumple
Cabeza Cumple Cumple 10.8 72.8 N.P. (3)
Cumple 72.8 G, Q(4) Q,N,M 93.33 0.07 -2.17 1.87 -0.05 Cumple
ENTREPISO (0 - 2.7 m) 25x50
Pie Cumple Cumple 10.8 75.6 N.P.(3) Cumple 75.6 G, Q(4) Q,N,M 94.25 -0.05 2.40 1.87 -0.05 Cumple
Cabeza Cumple Cumple 6.8 77.4 N.P.(3) Cumple 77.4 G, Q(4) Q,N,M 99.96 0.16 -1.82 1.19 -0.08 Cumple
PB (-2.66 - 0 m) 25x50
Pie Cumple Cumple 6.7 78.1 N.P.(3) Cumple 78.1 G, Q(4) Q,N,M 100.86 -0.02 1.06 1.19 -0.08 Cumple
SUBSUELO 25x50 Arranque N.P. (1)
N.P. (1)
N.P. (2)
78.1 N.P. (1)
Cumple 78.1 G, Q(4) N,M 100.86 -0.02 1.06 1.19 -0.08 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.15. C15

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 7.7 4.1 N.P.(3) Cumple 7.7 G, Q(4) Q,N,M 1.38 0.35 0.18 -0.11 -0.43 Cumple
TANQUE (38.2 - 40.7 m) 25x50
Pie Cumple Cumple 7.6 4.4 N.P. (3)
Cumple 7.6 G, Q(4) Q,N,M 2.22 -0.63 -0.07 -0.11 -0.43 Cumple
Cabeza Cumple Cumple 14.5 6.8 N.P.(3) Cumple 14.5 G, Q(4) Q,N,M 4.09 0.90 -0.07 0.05 -0.85 Cumple
P13 (35.7 - 38.2 m) 25x50
Pie Cumple Cumple 14.5 7.9 N.P.(3) Cumple 14.5 G, Q(4) Q,N,M 4.93 -1.02 0.04 0.05 -0.85 Cumple
Cabeza Cumple Cumple 6.2 8.9 N.P.(3) Cumple 8.9 G, Q(4) Q,N,M 7.69 0.94 0.03 -0.01 -0.70 Cumple
P12 (32.9 - 35.7 m) 25x50
Pie Cumple Cumple 6.2 8.8 N.P.(3) Cumple 8.8 G, Q(4) Q,N,M 8.64 -0.84 0.00 -0.01 -0.70 Cumple
Cabeza Cumple Cumple 5.6 10.1 N.P.(3) Cumple 10.1 G, Q(4) Q,N,M 11.06 0.79 0.00 0.01 -0.64 Cumple
P11 (30.1 - 32.9 m) 25x50
Pie Cumple Cumple 5.5 11.0 N.P.(3) Cumple 11.0 G, Q(4) Q,N,M 12.02 -0.85 0.02 0.01 -0.64 Cumple
Cabeza Cumple Cumple 5.9 12.9 N.P.(3) Cumple 12.9 G, Q(4) Q,N,M 14.63 0.91 0.01 0.00 -0.70 Cumple
P10 (27.3 - 30.1 m) 25x50
Pie Cumple Cumple 5.8 13.4 N.P.(3) Cumple 13.4 G, Q(4) Q,N,M 15.59 -0.87 0.01 0.00 -0.70 Cumple
Cabeza Cumple Cumple 5.4 15.0 N.P.(3) Cumple 15.0 G, Q(4) Q,N,M 18.19 0.85 0.01 0.01 -0.67 Cumple
P9 (24.5 - 27.3 m) 25x50
Pie Cumple Cumple 5.4 15.7 N.P.(3) Cumple 15.7 G, Q(4) Q,N,M 19.15 -0.85 0.03 0.01 -0.67 Cumple
Cabeza Cumple Cumple 5.2 17.5 N.P.(3) Cumple 17.5 G, Q(4) Q,N,M 21.78 0.84 -0.01 0.02 -0.65 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 5.1 18.2 N.P.(3) Cumple 18.2 G, Q(4) Q,N,M 22.73 -0.82 0.04 0.02 -0.65 Cumple
Cabeza Cumple Cumple 5.2 20.0 N.P.(3) Cumple 20.0 G, Q(4) Q,N,M 25.39 0.83 0.00 0.02 -0.67 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 5.1 20.6 N.P.(3) Cumple 20.6 G, Q(4) Q,N,M 26.31 -0.81 0.04 0.02 -0.67 Cumple
Cabeza Cumple Cumple 4.8 22.5 N.P.(3) Cumple 22.5 G, Q(4) Q,N,M 29.00 0.79 0.00 0.02 -0.64 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 4.8 23.2 N.P.(3) Cumple 23.2 G, Q(4) Q,N,M 29.92 -0.78 0.04 0.02 -0.64 Cumple
Cabeza Cumple Cumple 4.5 25.1 N.P.(3) Cumple 25.1 G, Q(4) Q,N,M 32.65 0.76 0.00 0.02 -0.62 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 4.5 25.8 N.P.(3) Cumple 25.8 G, Q(4) Q,N,M 33.57 -0.75 0.04 0.02 -0.62 Cumple
Cabeza Cumple Cumple 4.2 27.8 N.P.(3) Cumple 27.8 G, Q(4) Q,N,M 36.34 0.72 0.00 0.02 -0.59 Cumple
P4 (10.9 - 13.6 m) 25x50
Pie Cumple Cumple 4.2 28.4 N.P.(3) Cumple 28.4 G, Q(4) Q,N,M 37.26 -0.71 0.05 0.02 -0.59 Cumple
Cabeza Cumple Cumple 3.8 30.5 N.P.(3) Cumple 30.5 G, Q(4) Q,N,M 40.07 0.67 0.01 0.02 -0.54 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 3.8 31.1 N.P.(3) Cumple 31.1 G, Q(4) Q,N,M 40.99 -0.65 0.06 0.02 -0.54 Cumple
Cabeza Cumple Cumple 3.5 33.2 N.P.(3) Cumple 33.2 G, Q(4) Q,N,M 43.85 0.64 0.02 0.01 -0.52 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 3.5 33.9 N.P.(3) Cumple 33.9 G, Q(4) Q,N,M 44.77 -0.63 0.04 0.01 -0.52 Cumple
Cabeza Cumple Cumple 2.9 36.1 N.P.(3) Cumple 36.1 G, Q(4) Q,N,M 47.68 0.57 0.00 0.02 -0.44 Cumple
P1 (2.7 - 5.5 m) 25x50
Pie Cumple Cumple 2.9 36.8 N.P.(3) Cumple 36.8 G, Q(4) Q,N,M 48.64 -0.54 0.05 0.02 -0.44 Cumple

Página 14
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

ENTREPISO (0 - 2.7 m) 25x50 Cabeza Cumple Cumple 2.9 39.0 N.P.(3) Cumple 39.0 G, Q(4) Q,N,M 51.61 0.53 0.01 0.02 -0.44 Cumple
Pie Cumple Cumple 2.8 39.7 N.P.(3) Cumple 39.7 G, Q(4) Q,N,M 52.53 -0.54 0.05 0.02 -0.44 Cumple
Cabeza Cumple Cumple 1.7 41.9 N.P.(3) Cumple 41.9 G, Q(4) Q,N,M 55.56 0.43 0.01 0.01 -0.27 Cumple
PB (-2.66 - 0 m) 25x50
Pie Cumple Cumple 1.7 42.4 N.P.(3) Cumple 42.4 G, Q(4) Q,N,M 56.46 -0.22 0.04 0.01 -0.27 Cumple
SUBSUELO 25x50 Arranque N.P.(1) N.P.(1) N.P.(2) 42.4 N.P.(1) Cumple 42.4 G, Q(4) N,M 56.46 -0.22 0.04 0.01 -0.27 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.16. C16

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 2.50 0.95 0.36 -0.27 -1.74


Cabeza Cumple Cumple 29.4 17.5 N.P.(3) Cumple 29.4 Cumple
TANQUE (38.2 - 40.7 m) 20x60 G, Q(5) N,M 5.55 0.95 0.75 -0.57 -2.51
Pie Cumple Cumple 54.3 30.6 N.P.(3) Cumple 54.3 G, Q(5) Q,N,M 6.30 -4.32 -0.44 -0.57 -2.51 Cumple
Cabeza Cumple Cumple 87.0 36.8 N.P.(3) Cumple 87.0 G, Q(5) Q,N,M 15.89 5.97 -0.32 0.21 -4.55 Cumple
P13 (35.7 - 38.2 m) 20x60 G, Q, S(4) Q S. 8.61 -2.51 0.07 0.10 -2.86
Pie Cumple Cumple 47.7 27.0 N.P. (3)
Cumple 47.7 Cumple
G, Q(5) N,M 16.65 -3.60 0.13 0.21 -4.55
35.7 m N.P.(1) N.P.(1) N.P.(2) 27.0 N.P.(1) Cumple 27.0 G, Q(5) N,M 16.65 -3.60 0.13 0.21 -4.55 Cumple
G, S(6) Q S. 4.14 1.02 0.02 -0.01 -0.92
Cabeza Cumple Cumple 15.3 18.7 N.P. (3)
Cumple 18.7 Cumple
P12 (32.9 - 35.7 m) 20x60 G, Q(5) N,M 20.50 1.16 0.10 -0.05 -1.22
G, S (6)
Q S. 4.76 -1.18 0.00 -0.01 -0.91
Pie Cumple Cumple 15.3 21.3 N.P.(3) Cumple 21.3 Cumple
G, Q(5) N,M 21.36 -1.76 -0.03 -0.05 -1.22
Cabeza Cumple Cumple 16.6 26.4 N.P.(3) Cumple 26.4 G, Q(5) Q,N,M 25.43 2.36 -0.03 0.02 -1.88 Cumple
P11 (30.1 - 32.9 m) 20x60
Pie Cumple Cumple 16.5 26.2 N.P.(3) Cumple 26.2 G, Q(5) Q,N,M 26.30 -2.15 0.02 0.02 -1.88 Cumple
Cabeza Cumple Cumple 14.6 29.0 N.P.(3) Cumple 29.0 G, Q(5) Q,N,M 30.55 2.03 0.01 0.00 -1.72 Cumple
P10 (27.3 - 30.1 m) 20x60
Pie Cumple Cumple 14.6 29.9 N.P.(3) Cumple 29.9 G, Q(5) Q,N,M 31.42 -2.10 0.01 0.00 -1.72 Cumple
Cabeza Cumple Cumple 14.4 33.7 N.P.(3) Cumple 33.7 G, Q(5) Q,N,M 35.88 2.16 0.00 0.01 -1.76 Cumple
P9 (24.5 - 27.3 m) 20x60
Pie Cumple Cumple 14.4 34.0 N.P.(3) Cumple 34.0 G, Q(5) Q,N,M 36.75 -2.06 0.02 0.01 -1.76 Cumple
Cabeza Cumple Cumple 12.9 37.0 N.P.(3) Cumple 37.0 G, Q(5) Q,N,M 41.09 1.96 0.01 0.00 -1.62 Cumple
P8 (21.7 - 24.5 m) 20x60
Pie Cumple Cumple 12.8 37.6 N.P.(3) Cumple 37.6 G, Q(5) Q,N,M 41.95 -1.93 0.02 0.00 -1.62 Cumple
Cabeza Cumple Cumple 12.9 41.1 N.P.(3) Cumple 41.1 G, Q(5) Q,N,M 46.38 1.95 0.01 0.00 -1.67 Cumple
P7 (19 - 21.7 m) 20x60
Pie Cumple Cumple 12.8 41.7 N.P.(3) Cumple 41.7 G, Q(5) Q,N,M 47.20 -1.89 0.02 0.00 -1.67 Cumple
Cabeza Cumple Cumple 11.7 45.2 N.P.(3) Cumple 45.2 G, Q(5) Q,N,M 51.62 1.81 0.01 0.00 -1.56 Cumple
P6 (16.3 - 19 m) 20x60
Pie Cumple Cumple 11.6 45.8 N.P.(3) Cumple 45.8 G, Q(5) Q,N,M 52.45 -1.77 0.02 0.00 -1.56 Cumple
Cabeza Cumple Cumple 10.6 49.3 N.P.(3) Cumple 49.3 G, Q(5) Q,N,M 56.87 1.69 0.01 0.00 -1.45 Cumple
P5 (13.6 - 16.3 m) 20x60
Pie Cumple Cumple 10.5 50.0 N.P.(3) Cumple 50.0 G, Q(5) Q,N,M 57.69 -1.64 0.02 0.00 -1.45 Cumple
Cabeza Cumple Cumple 9.3 53.7 N.P.(3) Cumple 53.7 G, Q(5) Q,N,M 62.09 1.54 0.01 0.00 -1.32 Cumple
P4 (10.9 - 13.6 m) 20x60
Pie Cumple Cumple 9.3 54.3 N.P.(3) Cumple 54.3 G, Q(5) Q,N,M 62.92 -1.49 0.02 0.00 -1.32 Cumple
Cabeza Cumple Cumple 7.9 58.0 N.P.(3) Cumple 58.0 G, Q(5) Q,N,M 67.28 1.34 0.01 0.01 -1.15 Cumple
P3 (8.2 - 10.9 m) 20x60
Pie Cumple Cumple 7.9 58.7 N.P.(3) Cumple 58.7 G, Q(5) Q,N,M 68.11 -1.30 0.03 0.01 -1.15 Cumple
Cabeza Cumple Cumple 6.4 62.3 N.P.(3) Cumple 62.3 G, Q(5) Q,N,M 72.41 1.12 0.02 0.00 -0.95 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 6.4 63.0 N.P.(3) Cumple 63.0 G, Q(5) Q,N,M 73.24 -1.06 0.02 0.00 -0.95 Cumple
P1 (2.7 - 5.5 m) 20x60 Cabeza Cumple Cumple 4.8 67.5 N.P.(3) Cumple 67.5 G, Q(5) Q,N,M 77.47 0.92 0.01 0.01 -0.73 Cumple

Página 15
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Pie Cumple Cumple 4.8 68.2 N.P.(3) Cumple 68.2 G, Q(5) Q,N,M 78.34 -0.83 0.02 0.01 -0.73 Cumple
ENTREPISO (0 - 2.7 m) 20x60 Cabeza Cumple Cumple 3.5 71.2 N.P.(3) Cumple 71.2 G, Q(5) Q,N,M 82.44 0.68 0.02 0.00 -0.54 Cumple
Pie Cumple Cumple 3.5 72.0 N.P.(3) Cumple 72.0 G, Q(5) Q,N,M 83.27 -0.57 0.02 0.00 -0.54 Cumple
G, Q, S(4) Q S. 53.46 0.27 0.01 0.00 -0.34
Cabeza Cumple Cumple 2.2 75.4 N.P.(3) Cumple 75.4 Cumple
G, Q(5) N,M 87.30 0.43 0.01 0.00 -0.28
PB (-2.66 - 0 m) 20x60
G, Q, S (4)
Q S. 54.31 -0.49 0.02 0.00 -0.34
Pie Cumple Cumple 2.2 75.9 N.P.(3) Cumple 75.9 Cumple
G, Q(5) N,M 88.12 -0.20 0.02 0.00 -0.28
SUBSUELO 20x60 Arranque N.P.(1) N.P.(1) N.P.(2) 75.9 N.P.(1) Cumple 75.9 G, Q(5) N,M 88.12 -0.20 0.02 0.00 -0.28 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
1.2·PP+1.2·CM+1.6·Qa
(6)
0.855·PP+0.855·CM-SY

1.17. C17

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 39.1 51.5 N.P.(3) Cumple 51.5 G, Q(4) Q,N,M 4.91 -0.40 -2.89 1.84 -0.47 Cumple
TANQUE (38.2 - 40.7 m) 25x50
Pie Cumple Cumple 37.1 24.1 N.P.(3) Cumple 37.1 G, Q(4) Q,N,M 5.75 -1.45 1.26 1.84 -0.47 Cumple
Cabeza Cumple Cumple 27.0 29.1 N.P.(3) Cumple 29.1 G, Q(4) Q,N,M 11.96 2.44 1.20 -0.71 -1.53 Cumple
P13 (35.7 - 38.2 m) 25x50
Pie Cumple Cumple 14.6 13.0 N.P.(3) Cumple 14.6 G, Q(4) Q,N,M 12.81 -1.01 -0.40 -0.71 -1.53 Cumple
35.7 m N.P.(1) N.P.(1) N.P.(2) 13.0 N.P.(1) Cumple 13.0 G, Q(4) N,M 12.81 -1.01 -0.40 -0.71 -1.53 Cumple
G, Q, S(5) Q S. 10.46 -0.62 -0.16 0.08 0.44
Cabeza Cumple Cumple 3.4 12.4 N.P.(3) Cumple 12.4 Cumple
P12 (32.9 - 35.7 m) 25x50 G, Q(4) N,M 16.42 -0.32 -0.30 0.15 0.14
G, Q, S(5) Q S. 11.45 0.49 0.05 0.08 0.44
Pie Cumple Cumple 3.4 12.7 N.P.(3) Cumple 12.7 Cumple
G, Q(4) N,M 17.38 0.04 0.10 0.15 0.14
G, Q, S (6)
Q S. 11.64 0.58 0.07 -0.03 -0.47
Cabeza Cumple Cumple 3.6 15.5 N.P.(3) Cumple 15.5 Cumple
G, Q(4) N,M 20.82 0.28 0.13 -0.07 -0.20
P11 (30.1 - 32.9 m) 25x50
G, Q, S (6)
Q S. 12.64 -0.61 -0.02 -0.03 -0.47
Pie Cumple Cumple 3.5 16.2 N.P.(3) Cumple 16.2 Cumple
G, Q(4) N,M 21.77 -0.23 -0.05 -0.07 -0.20
G, Q, S(6) Q S. 14.54 0.47 0.01 0.00 -0.39
Cabeza Cumple Cumple 2.9 18.9 N.P.(3) Cumple 18.9 Cumple
G, Q(4) N,M 25.38 0.27 0.01 -0.01 -0.20
P10 (27.3 - 30.1 m) 25x50
G, Q, S (6)
Q S. 15.53 -0.53 0.00 0.00 -0.39
Pie Cumple Cumple 2.9 19.6 N.P.(3) Cumple 19.6 Cumple
G, Q(4) N,M 26.34 -0.24 -0.01 -0.01 -0.20
G, Q, S (6)
Q S. 17.42 0.48 0.03 -0.01 -0.43
Cabeza Cumple Cumple 3.1 22.3 N.P.(3) Cumple 22.3 Cumple
G, Q(4) N,M 29.91 0.27 0.05 -0.03 -0.20
P9 (24.5 - 27.3 m) 25x50
G, Q, S(6) Q S. 18.41 -0.62 0.01 -0.01 -0.43
Pie Cumple Cumple 3.1 22.9 N.P.(3) Cumple 22.9 Cumple
G, Q(4) N,M 30.86 -0.25 -0.02 -0.03 -0.20
G, Q, S(6) Q S. 20.38 0.36 0.03 -0.01 -0.32
Cabeza Cumple Cumple 2.2 25.6 N.P.(3) Cumple 25.6 Cumple
G, Q(4) N,M 34.39 0.27 0.04 -0.02 -0.21
P8 (21.7 - 24.5 m) 25x50
G, Q, S (6)
Q S. 21.16 -0.50 0.00 -0.01 -0.33
Pie Cumple Cumple 2.3 26.3 N.P.(3) Cumple 26.3 Cumple
G, Q(4) N,M 35.35 -0.26 -0.01 -0.02 -0.21
G, Q, S(6) Q S. 22.93 0.39 0.03 -0.01 -0.38
Cabeza Cumple Cumple 2.6 28.9 N.P.(3) Cumple 28.9 Cumple
G, Q(4) N,M 38.84 0.27 0.05 -0.02 -0.22
P7 (19 - 21.7 m) 25x50
G, Q, S(6) Q S. 23.88 -0.53 0.01 -0.01 -0.38
Pie Cumple Cumple 2.6 29.6 N.P.(3) Cumple 29.6 Cumple
G, Q(4) N,M 39.76 -0.26 -0.01 -0.02 -0.22

Página 16
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(6) Q S. 26.31 0.47 0.02 -0.01 -0.36


Cabeza Cumple Cumple 2.4 32.3 N.P.(3) Cumple 32.3 Cumple
G, Q(4) N,M 43.20 0.27 0.04 -0.02 -0.22
P6 (16.3 - 19 m) 25x50
G, Q, S (6)
Q S. 27.05 -0.44 0.00 -0.01 -0.36
Pie Cumple Cumple 2.4 33.0 N.P.(3) Cumple 33.0 Cumple
G, Q(4) N,M 44.12 -0.26 0.00 -0.02 -0.22
G, Q, S(6) Q S. 29.04 0.47 0.02 -0.01 -0.38
Cabeza Cumple Cumple 2.5 35.6 N.P.(3) Cumple 35.6 Cumple
G, Q(4) N,M 47.49 0.26 0.05 -0.02 -0.21
P5 (13.6 - 16.3 m) 25x50
G, Q, S (6)
Q S. 29.99 -0.47 0.01 -0.01 -0.38
Pie Cumple Cumple 2.5 36.3 N.P.(3) Cumple 36.3 Cumple
G, Q(4) N,M 48.40 -0.26 0.00 -0.02 -0.21
G, Q, S(6) Q S. 31.56 0.37 0.03 -0.01 -0.37
Cabeza Cumple Cumple 2.4 38.8 N.P.(3) Cumple 38.8 Cumple
G, Q(4) N,M 51.69 0.25 0.05 -0.02 -0.21
P4 (10.9 - 13.6 m) 25x50
G, Q, S(6) Q S. 32.52 -0.52 0.01 -0.01 -0.37
Pie Cumple Cumple 2.4 39.5 N.P.(3) Cumple 39.5 Cumple
G, Q(4) N,M 52.61 -0.26 0.00 -0.02 -0.21
G, Q, S (6)
Q S. 34.21 0.26 0.04 0.02 -0.44
Cabeza Cumple Cumple 2.8 42.0 N.P.(3) Cumple 42.0 Cumple
P3 (8.2 - 10.9 m) 25x50 G, Q(4) N,M 55.81 0.22 0.05 -0.01 -0.20
Pie Cumple Cumple 2.8 42.8 N.P. (3)
Cumple 42.8 G, Q, S (6)
Q S. 35.16 -0.82 0.07 0.02 -0.44 Cumple
G, Q(4) N,M 56.73 -0.28 0.02 -0.01 -0.20
G, Q, S(5) Q S. 37.78 0.27 0.00 0.00 -0.16
Cabeza Cumple Cumple 1.0 45.1 N.P.(3) Cumple 45.1 Cumple
G, Q(4) N,M 59.82 0.14 0.06 -0.02 -0.12
P2 (5.5 - 8.2 m) 25x50
G, Q, S (5)
Q S. 38.74 -0.13 0.01 0.00 -0.16
Pie Cumple Cumple 1.0 45.7 N.P.(3) Cumple 45.7 Cumple
G, Q(4) N,M 60.74 -0.15 0.00 -0.02 -0.12
G, Q, S (6)
Q S. 39.24 0.26 0.01 0.00 -0.23
Cabeza Cumple Cumple 1.4 48.4 N.P.(3) Cumple 48.4 Cumple
G, Q(4) N,M 63.71 0.22 0.04 -0.01 -0.16
P1 (2.7 - 5.5 m) 25x50
G, Q, S(6) Q S. 40.23 -0.32 0.02 0.00 -0.23
Pie Cumple Cumple 1.4 49.1 N.P.(3) Cumple 49.1 Cumple
G, Q(4) N,M 64.67 -0.19 0.01 -0.01 -0.16
G, Q, S(5) Q S. 42.64 0.13 0.03 -0.01 -0.17
Cabeza Cumple Cumple 1.0 51.1 N.P.(3) Cumple 51.1 Cumple
G, Q(4) N,M 67.49 0.19 0.05 -0.02 -0.14
ENTREPISO (0 - 2.7 m) 25x50
G, Q, S (5)
Q S. 43.59 -0.28 0.01 -0.01 -0.17
Pie Cumple Cumple 1.0 51.8 N.P.(3) Cumple 51.8 Cumple
G, Q(4) N,M 68.40 -0.16 0.01 -0.02 -0.14
G, Q, S(5) Q S. 44.85 0.07 0.03 0.00 -0.19
Cabeza Cumple Cumple 1.1 53.9 N.P.(3) Cumple 53.9 Cumple
G, Q(4) N,M 71.06 0.22 0.04 -0.01 -0.12
PB (-2.66 - 0 m) 25x50
G, Q, S(5) Q S. 45.86 -0.38 0.04 0.00 -0.19
Pie Cumple Cumple 1.1 54.5 N.P.(3) Cumple 54.5 Cumple
G, Q(4) N,M 71.96 -0.06 0.02 -0.01 -0.12
SUBSUELO 25x50 Arranque N.P. (1)
N.P. (1)
N.P. (2)
54.5 N.P. (1)
Cumple 54.5 G, Q (4)
N,M 71.96 -0.06 0.02 -0.01 -0.12 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+0.5·Qa-SY
(6)
1.245·PP+1.245·CM+0.5·Qa+SY

1.18. C18

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 1.00 -0.42 -0.24 0.21 0.01


Cabeza Cumple Cumple 3.8 6.5 N.P.(3) Cumple 6.5 Cumple
G, Q(5) N,M 2.10 -0.86 -0.14 0.15 0.05
P12 (32.9 - 35.7 m) 25x50
G, Q, S (4)
Q S. 2.00 -0.39 0.30 0.21 0.01
Pie Cumple Cumple 3.7 7.0 N.P.(3) Cumple 7.0 Cumple
G, Q(5) N,M 3.06 -0.73 0.23 0.15 0.05

Página 17
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 7.3 13.4 N.P.(3) Cumple 13.4 G, Q(5) Q,N,M 8.53 1.69 -0.02 -0.08 -0.82 Cumple
P11 (30.1 - 32.9 m) 25x50
Pie Cumple Cumple 7.3 7.7 N.P.(3) Cumple 7.7 G, Q(5) Q,N,M 9.49 -0.39 -0.22 -0.08 -0.82 Cumple
Cabeza Cumple Cumple 5.3 13.2 N.P.(3) Cumple 13.2 G, Q(5) Q,N,M 13.89 -0.82 0.45 -0.31 0.54 Cumple
P10 (27.3 - 30.1 m) 25x50
Pie Cumple Cumple 5.3 11.9 N.P.(3) Cumple 11.9 G, Q(5) Q,N,M 14.85 0.56 -0.33 -0.31 0.54 Cumple
Cabeza Cumple Cumple 2.6 14.1 N.P.(3) Cumple 14.1 G, Q(5) Q,N,M 18.88 -0.30 0.25 -0.20 0.25 Cumple
P9 (24.5 - 27.3 m) 25x50
Pie Cumple Cumple 2.6 14.9 N.P.(3) Cumple 14.9 G, Q(5) Q,N,M 19.83 0.34 -0.25 -0.20 0.25 Cumple
Cabeza Cumple Cumple 2.8 18.0 N.P.(3) Cumple 18.0 G, Q(5) Q,N,M 23.98 -0.36 0.30 -0.22 0.28 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 2.8 18.7 N.P.(3) Cumple 18.7 G, Q(5) Q,N,M 24.94 0.36 -0.26 -0.22 0.28 Cumple
Cabeza Cumple Cumple 2.8 21.7 N.P.(3) Cumple 21.7 G, Q(5) Q,N,M 29.09 -0.34 0.29 -0.22 0.28 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 2.7 22.4 N.P.(3) Cumple 22.4 G, Q(5) Q,N,M 30.01 0.34 -0.26 -0.22 0.28 Cumple
Cabeza Cumple Cumple 2.6 25.5 N.P.(3) Cumple 25.5 G, Q(5) Q,N,M 34.18 -0.34 0.29 -0.22 0.27 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 2.6 26.2 N.P.(3) Cumple 26.2 G, Q(5) Q,N,M 35.10 0.34 -0.24 -0.22 0.27 Cumple
Cabeza Cumple Cumple 2.4 29.3 N.P.(3) Cumple 29.3 G, Q(5) Q,N,M 39.27 -0.33 0.28 -0.21 0.27 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 2.4 30.0 N.P.(3) Cumple 30.0 G, Q(5) Q,N,M 40.19 0.33 -0.23 -0.21 0.27 Cumple
Cabeza Cumple Cumple 2.3 33.2 N.P.(3) Cumple 33.2 G, Q(5) Q,N,M 44.38 -0.33 0.27 -0.20 0.26 Cumple
P4 (10.9 - 13.6 m) 25x50
Pie Cumple Cumple 2.3 33.9 N.P.(3) Cumple 33.9 G, Q(5) Q,N,M 45.29 0.32 -0.21 -0.20 0.26 Cumple
Cabeza Cumple Cumple 2.2 37.1 N.P.(3) Cumple 37.1 G, Q(5) Q,N,M 49.49 -0.33 0.26 -0.19 0.27 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 2.2 37.9 N.P.(3) Cumple 37.9 G, Q(5) Q,N,M 50.41 0.33 -0.19 -0.19 0.27 Cumple
Cabeza Cumple Cumple 2.1 41.1 N.P.(3) Cumple 41.1 G, Q(5) Q,N,M 54.63 -0.31 0.27 -0.19 0.26 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 2.1 41.9 N.P.(3) Cumple 41.9 G, Q(5) Q,N,M 55.55 0.33 -0.20 -0.19 0.26 Cumple
Cabeza Cumple Cumple 1.8 45.3 N.P.(3) Cumple 45.3 G, Q(5) Q,N,M 59.76 -0.32 0.22 -0.15 0.24 Cumple
P1 (2.7 - 5.5 m) 25x50
Pie Cumple Cumple 1.8 46.1 N.P.(3) Cumple 46.1 G, Q(5) Q,N,M 60.72 0.30 -0.17 -0.15 0.24 Cumple
Cabeza Cumple Cumple 2.0 49.3 N.P.(3) Cumple 49.3 G, Q(5) Q,N,M 64.96 -0.34 0.21 -0.14 0.29 Cumple
ENTREPISO (0 - 2.7 m) 25x50
Pie Cumple Cumple 2.0 50.0 N.P.(3) Cumple 50.0 G, Q(5) Q,N,M 65.88 0.38 -0.12 -0.14 0.29 Cumple
Cabeza Cumple Cumple 1.3 51.5 N.P.(3) Cumple 51.5 G, Q(5) Q,N,M 70.01 -0.28 0.10 -0.05 0.18 Cumple
PB (-2.66 - 0 m) 25x50
Pie Cumple Cumple 1.3 52.1 N.P.(3) Cumple 52.1 G, Q(5) Q,N,M 70.91 0.15 -0.02 -0.05 0.18 Cumple
SUBSUELO 25x50 Arranque N.P.(1) N.P.(1) N.P.(2) 53.7 N.P.(1) Cumple 53.7 G, Q(5) N,M 70.91 0.15 -0.02 -0.05 0.18 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa+SX
(5)
1.2·PP+1.2·CM+1.6·Qa

1.19. C19

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 38.4 29.4 N.P.(3) Cumple 38.4 G, Q(4) Q,N,M 9.05 0.51 1.53 -1.97 -0.43 Cumple
P12 (32.9 - 35.7 m) 20x60
Pie Cumple Cumple 40.0 75.0 N.P.(3) Cumple 75.0 G, Q(4) Q,N,M 9.91 -0.53 -3.21 -1.97 -0.43 Cumple
32.9 m N.P.(1) N.P.(1) N.P.(2) 75.0 N.P.(1) Cumple 75.0 G, Q(4) N,M 9.91 -0.53 -3.21 -1.97 -0.43 Cumple
P11 (30.1 - 32.9 m) 20x60 Cabeza Cumple Cumple 53.0 74.7 N.P.(3) Cumple 74.7 G, Q(4) Q,N,M 24.60 0.41 3.75 -2.67 -0.40 Cumple
Pie Cumple Cumple 49.6 55.4 N.P.(3) Cumple 55.4 G, Q(4) Q,N,M 25.47 -0.54 -2.67 -2.67 -0.40 Cumple
30.1 m N.P.(1) N.P.(1) N.P.(2) 55.4 N.P.(1) Cumple 55.4 G, Q(4) N,M 25.47 -0.54 -2.67 -2.67 -0.40 Cumple
P10 (27.3 - 30.1 m) 20x60 Cabeza Cumple Cumple 8.5 35.4 N.P.(3) Cumple 35.4 G, Q(4) Q,N,M 33.86 0.32 1.31 -1.17 -0.02 Cumple
Pie Cumple Cumple 8.4 39.0 N.P.(3) Cumple 39.0 G, Q(4) Q,N,M 34.72 0.27 -1.50 -1.17 -0.02 Cumple
P9 (24.5 - 27.3 m) 20x60 Cabeza Cumple Cumple 10.3 47.5 N.P.(3) Cumple 47.5 G, Q(4) Q,N,M 41.14 -0.54 1.79 -1.47 0.25 Cumple

Página 18
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Pie Cumple Cumple 10.3 46.2 N.P.(3) Cumple 46.2 G, Q(4) Q,N,M 42.01 0.05 -1.73 -1.47 0.25 Cumple
Cabeza Cumple Cumple 9.4 50.6 N.P.(3) Cumple 50.6 G, Q(4) Q,N,M 50.16 0.42 1.69 -1.40 -0.28 Cumple
P8 (21.7 - 24.5 m) 20x60
Pie Cumple Cumple 9.3 50.5 N.P.(3) Cumple 50.5 G, Q(4) Q,N,M 51.02 -0.24 -1.66 -1.40 -0.28 Cumple
Cabeza Cumple Cumple 9.5 56.1 N.P. (3)
Cumple 56.1 G, Q(4) Q,N,M 58.98 0.09 1.75 -1.51 -0.10 Cumple
P7 (19 - 21.7 m) 20x60
Pie Cumple Cumple 9.4 56.1 N.P.(3) Cumple 56.1 G, Q(4) Q,N,M 59.81 -0.14 -1.72 -1.51 -0.10 Cumple
Cabeza Cumple Cumple 9.0 61.4 N.P.(3) Cumple 61.4 G, Q(4) Q,N,M 67.99 0.19 1.73 -1.50 -0.16 Cumple
P6 (16.3 - 19 m) 20x60
Pie Cumple Cumple 9.0 61.5 N.P.(3) Cumple 61.5 G, Q(4) Q,N,M 68.82 -0.17 -1.71 -1.50 -0.16 Cumple
Cabeza Cumple Cumple 8.7 67.4 N.P.(3) Cumple 67.4 G, Q(4) Q,N,M 77.18 0.14 1.75 -1.51 -0.12 Cumple
P5 (13.6 - 16.3 m) 20x60
Pie Cumple Cumple 8.7 67.6 N.P.(3) Cumple 67.6 G, Q(4) Q,N,M 78.01 -0.13 -1.72 -1.51 -0.12 Cumple
Cabeza Cumple Cumple 8.4 74.9 N.P.(3) Cumple 74.9 G, Q(4) Q,N,M 86.61 0.11 1.75 -1.51 -0.09 Cumple
P4 (10.9 - 13.6 m) 20x60
Pie Cumple Cumple 8.4 75.7 N.P.(3) Cumple 75.7 G, Q(4) Q,N,M 87.44 -0.11 -1.72 -1.51 -0.09 Cumple
Cabeza Cumple Cumple 8.1 84.6 N.P.(3) Cumple 84.6 G, Q(4) Q,N,M 96.31 0.04 1.77 -1.52 -0.03 Cumple
P3 (8.2 - 10.9 m) 20x60
Pie Cumple Cumple 8.1 85.5 N.P.(3) Cumple 85.5 G, Q(4) Q,N,M 97.13 -0.04 -1.72 -1.52 -0.03 Cumple
Cabeza Cumple Cumple 8.1 95.1 N.P.(3) Cumple 95.1 G, Q(4) Q,N,M 106.30 -0.05 1.81 -1.57 0.05 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 8.1 96.3 N.P.(3) Cumple 96.3 G, Q(4) Q,N,M 107.13 0.08 -1.80 -1.57 0.05 Cumple
Cabeza Cumple Cumple 7.0 98.7 N.P.(3) Cumple 98.7 G, Q(4) Q,N,M 116.68 -0.08 1.75 -1.42 0.08 Cumple
P1 (2.7 - 5.5 m) 20x60
Pie Cumple Cumple 7.0 99.7 N.P.(3) Cumple 99.7 G, Q(4) Q,N,M 117.54 0.11 -1.67 -1.42 0.08 Cumple
Cabeza Cumple Cumple 7.9 99.1 N.P.(3) Cumple 99.1 G, Q(4) Q,N,M 127.48 -0.19 1.85 -1.64 0.20 Cumple
ENTREPISO (0 - 2.7 m) 20x60
Pie Cumple Cumple 7.9 100.0 N.P.(3) Cumple 100.0 G, Q(4) Q,N,M 128.31 0.28 -1.92 -1.64 0.20 Cumple
Cabeza Cumple Cumple 5.2 98.5 N.P.(3) Cumple 98.5 G, Q(4) Q,N,M 138.85 -0.18 1.56 -1.09 0.14 Cumple
PB (-2.66 - 0 m) 20x60
Pie Cumple Cumple 5.2 99.2 N.P.(3) Cumple 99.2 G, Q(4) Q,N,M 139.66 0.14 -0.91 -1.09 0.14 Cumple
SUBSUELO 20x60 Arranque N.P.(1) N.P.(1) N.P.(2) 99.2 N.P.(1) Cumple 99.2 G, Q(4) N,M 139.66 0.14 -0.91 -1.09 0.14 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.20. C20

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 72.6 73.1 N.P.(3) Cumple 73.1 G, Q(4) Q,N,M 6.70 -0.20 -4.06 3.47 -0.48 Cumple
P12 (32.9 - 35.7 m) 25x50
Pie Cumple Cumple 73.1 88.1 N.P.(3) Cumple 88.1 G, Q(4) Q,N,M 7.66 -1.42 4.80 3.47 -0.48 Cumple
32.9 m N.P.(1) N.P.(1) N.P.(2) 88.1 N.P.(1) Cumple 88.1 G, Q(4) N,M 7.66 -1.42 4.80 3.47 -0.48 Cumple
P11 (30.1 - 32.9 m) 25x50 Cabeza Cumple Cumple 60.8 63.0 N.P.(3) Cumple 63.0 G, Q(4) Q,N,M 19.20 2.15 -3.92 2.93 -1.14 Cumple
Pie Cumple Cumple 59.7 52.6 N.P.(3) Cumple 59.7 G, Q(4) Q,N,M 20.16 -0.75 3.55 2.93 -1.14 Cumple
30.1 m N.P. (1)
N.P. (1)
N.P. (2)
52.6 N.P. (1)
Cumple 52.6 G, Q(4) N,M 20.16 -0.75 3.55 2.93 -1.14 Cumple
P10 (27.3 - 30.1 m) 25x50 Cabeza Cumple Cumple 41.0 51.1 N.P.(3) Cumple 51.1 G, Q(4) Q,N,M 28.21 -0.55 -3.16 2.53 0.37 Cumple
Pie Cumple Cumple 42.3 52.5 N.P.(3) Cumple 52.5 G, Q(4) Q,N,M 29.17 0.39 3.29 2.53 0.37 Cumple
Cabeza Cumple Cumple 20.1 57.3 N.P.(3) Cumple 57.3 G, Q(4) Q,N,M 36.78 -0.12 -3.38 2.65 0.09 Cumple
P9 (24.5 - 27.3 m) 25x50
Pie Cumple Cumple 20.0 57.6 N.P.(3) Cumple 57.6 G, Q(4) Q,N,M 37.74 0.09 3.38 2.65 0.09 Cumple
Cabeza Cumple Cumple 18.5 59.6 N.P.(3) Cumple 59.6 G, Q(4) Q,N,M 45.67 -0.04 -3.29 2.58 0.05 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 18.4 60.0 N.P.(3) Cumple 60.0 G, Q(4) Q,N,M 46.63 0.08 3.29 2.58 0.05 Cumple
Cabeza Cumple Cumple 18.6 63.8 N.P.(3) Cumple 63.8 G, Q(4) Q,N,M 54.54 -0.10 -3.32 2.72 0.08 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 18.5 64.4 N.P.(3) Cumple 64.4 G, Q(4) Q,N,M 55.46 0.09 3.33 2.72 0.08 Cumple
P6 (16.3 - 19 m) 25x50 Cabeza Cumple Cumple 17.6 67.4 N.P.(3) Cumple 67.4 G, Q(4) Q,N,M 63.43 -0.06 -3.26 2.68 0.06 Cumple

Página 19
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Pie Cumple Cumple 17.5 68.4 N.P.(3) Cumple 68.4 G, Q(4) Q,N,M 64.35 0.07 3.30 2.68 0.06 Cumple
Cabeza Cumple Cumple 16.8 71.9 N.P.(3) Cumple 71.9 G, Q(4) Q,N,M 72.38 -0.08 -3.25 2.67 0.06 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 16.7 72.9 N.P.(3) Cumple 72.9 G, Q(4) Q,N,M 73.30 0.07 3.29 2.67 0.06 Cumple
Cabeza Cumple Cumple 16.1 77.0 N.P.(3) Cumple 77.0 G, Q(4) Q,N,M 81.39 -0.08 -3.23 2.66 0.06 Cumple
P4 (10.9 - 13.6 m) 25x50
Pie Cumple Cumple 16.0 78.1 N.P.(3) Cumple 78.1 G, Q(4) Q,N,M 82.31 0.07 3.28 2.66 0.06 Cumple
Cabeza Cumple Cumple 15.4 82.0 N.P.(3) Cumple 82.0 G, Q(4) Q,N,M 90.48 -0.11 -3.20 2.63 0.06 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 15.3 83.0 N.P.(3) Cumple 83.0 G, Q(4) Q,N,M 91.40 0.04 3.24 2.63 0.06 Cumple
Cabeza Cumple Cumple 14.9 87.2 N.P.(3) Cumple 87.2 G, Q(4) Q,N,M 99.65 -0.18 -3.18 2.64 0.15 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 14.9 89.2 N.P.(3) Cumple 89.2 G, Q(4) Q,N,M 100.57 0.18 3.29 2.64 0.15 Cumple
Cabeza Cumple Cumple 13.2 92.9 N.P.(3) Cumple 92.9 G, Q(4) Q,N,M 108.92 -0.10 -3.09 2.41 0.09 Cumple
P1 (2.7 - 5.5 m) 25x50
Pie Cumple Cumple 13.1 92.8 N.P.(3) Cumple 92.8 G, Q(4) Q,N,M 109.88 0.12 3.04 2.41 0.09 Cumple
Cabeza Cumple Cumple 13.1 94.9 N.P.(3) Cumple 94.9 G, Q(4) Q,N,M 118.35 -0.15 -3.24 2.78 0.15 Cumple
ENTREPISO (0 - 2.7 m) 25x50
Pie Cumple Cumple 13.1 98.9 N.P.(3) Cumple 98.9 G, Q(4) Q,N,M 119.27 0.22 3.58 2.78 0.15 Cumple
0m N.P.(1) N.P.(1) N.P.(2) 98.9 N.P.(1) Cumple 98.9 G, Q(4) N,M 119.27 0.22 3.58 2.78 0.15 Cumple
PB (-2.66 - 0 m) 25x50 Cabeza Cumple Cumple 8.3 96.9 N.P.(3) Cumple 96.9 G, Q(4) Q,N,M 127.85 -0.08 -2.76 1.80 0.08 Cumple
Pie Cumple Cumple 8.2 97.3 N.P.(3) Cumple 97.3 G, Q(4) Q,N,M 128.75 0.10 1.58 1.80 0.08 Cumple
SUBSUELO 25x50 Arranque N.P.(1) N.P.(1) N.P.(2) 100.0 N.P.(1) Cumple 100.0 G, Q(4) N,M 128.75 0.10 1.58 1.80 0.08 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.21. C21

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 1.37 -0.41 0.26 -0.26 0.08


Cabeza Cumple Cumple 4.8 5.6 N.P.(3) Cumple 5.6 Cumple
P10 (27.3 - 30.1 m) 25x50 G, Q, S(4) N,M S. 1.39 -0.44 0.26 -0.25 0.10
Pie Cumple Cumple 4.7 6.1 N.P. (3)
Cumple 6.1 G, Q, S (4)
Q S.,N,M S. 2.36 -0.19 -0.40 -0.26 0.08 Cumple
Cabeza Cumple Cumple 5.8 11.9 N.P.(3) Cumple 11.9 G, Q(5) Q,N,M 8.64 1.12 0.37 -0.29 -0.57 Cumple
P9 (24.5 - 27.3 m) 25x50
Pie Cumple Cumple 5.7 8.8 N.P.(3) Cumple 8.8 G, Q(5) Q,N,M 9.60 -0.33 -0.37 -0.29 -0.57 Cumple
Cabeza Cumple Cumple 3.4 11.4 N.P.(3) Cumple 11.4 G, Q(5) Q,N,M 13.77 -0.42 0.39 -0.28 0.27 Cumple
P8 (21.7 - 24.5 m) 25x50
Pie Cumple Cumple 3.4 11.1 N.P.(3) Cumple 11.1 G, Q(5) Q,N,M 14.72 0.27 -0.33 -0.28 0.27 Cumple
G, Q, S(4) Q S. 12.60 -0.09 0.38 -0.31 0.09
Cabeza Cumple Cumple 2.6 13.7 N.P. (3)
Cumple 13.7 Cumple
G, Q(5) N,M 18.61 -0.12 0.35 -0.28 0.11
P7 (19 - 21.7 m) 25x50
G, Q, S (4)
Q S. 13.57 0.12 -0.38 -0.31 0.08
Pie Cumple Cumple 2.6 14.4 N.P.(3) Cumple 14.4 Cumple
G, Q(5) N,M 19.53 0.15 -0.32 -0.28 0.11
Cabeza Cumple Cumple 2.5 17.3 N.P. (3)
Cumple 17.3 G, Q (5)
Q,N,M 23.43 -0.16 0.36 -0.28 0.13 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 2.5 18.0 N.P.(3) Cumple 18.0 G, Q(5) Q,N,M 24.35 0.15 -0.32 -0.28 0.13 Cumple
G, Q, S(4) Q S. 18.89 -0.11 0.38 -0.30 0.09
Cabeza Cumple Cumple 2.4 20.9 N.P. (3)
Cumple 20.9 Cumple
G, Q(5) N,M 28.24 -0.12 0.35 -0.27 0.10
P5 (13.6 - 16.3 m) 25x50
G, Q, S (4)
Q S. 19.89 0.11 -0.35 -0.30 0.09
Pie Cumple Cumple 2.3 21.6 N.P.(3) Cumple 21.6 Cumple
G, Q(5) N,M 29.15 0.12 -0.30 -0.27 0.10
P4 (10.9 - 13.6 m) 25x50 G, Q, S(4) Q S. 22.11 -0.09 0.37 -0.29 0.08
Cabeza Cumple Cumple 2.2 24.4 N.P.(3) Cumple 24.4 Cumple
G, Q(5) N,M 33.03 -0.10 0.35 -0.26 0.07
Pie Cumple Cumple 2.2 25.1 N.P.(3) Cumple 25.1 G, Q, S(4) Q S. 23.10 0.10 -0.35 -0.29 0.08 Cumple

Página 20
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q(5) N,M 33.95 0.08 -0.29 -0.26 0.07


G, Q, S(4) Q S. 25.35 -0.05 0.33 -0.31 0.05
Cabeza Cumple Cumple 2.3 28.0 N.P. (3)
Cumple 28.0 Cumple
G, Q(5) N,M 37.83 -0.07 0.34 -0.25 0.07
P3 (8.2 - 10.9 m) 25x50
G, Q, S (4)
Q S. 26.31 0.09 -0.41 -0.30 0.06
Pie Cumple Cumple 2.2 28.8 N.P.(3) Cumple 28.8 Cumple
G, Q(5) N,M 38.74 0.09 -0.27 -0.25 0.07
Cabeza Cumple Cumple 2.0 31.6 N.P. (3)
Cumple 31.6 G, Q (5)
Q,N,M 42.58 -0.06 0.37 -0.28 0.05 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 2.0 32.4 N.P.(3) Cumple 32.4 G, Q(5) Q,N,M 43.50 0.05 -0.30 -0.28 0.05 Cumple
Cabeza Cumple Cumple 1.6 35.4 N.P.(3) Cumple 35.4 G, Q(5) Q,N,M 47.32 -0.02 0.31 -0.22 0.02 Cumple
P1 (2.7 - 5.5 m) 25x50
Pie Cumple Cumple 1.6 36.1 N.P.(3) Cumple 36.1 G, Q(5) Q,N,M 48.28 0.02 -0.26 -0.22 0.02 Cumple
Cabeza Cumple Cumple 1.6 38.9 N.P.(3) Cumple 38.9 G, Q(5) Q,N,M 52.08 0.00 0.32 -0.24 0.00 Cumple
ENTREPISO (0 - 2.7 m) 25x50
Pie Cumple Cumple 1.6 39.7 N.P.(3) Cumple 39.7 G, Q(5) Q,N,M 53.00 -0.01 -0.26 -0.24 0.00 Cumple
Cabeza Cumple Cumple 0.9 42.5 N.P.(3) Cumple 42.5 G, Q(5) Q,N,M 56.71 0.05 0.22 -0.13 -0.03 Cumple
PB (-2.66 - 0 m) 25x50
Pie Cumple Cumple 0.9 43.2 N.P.(3) Cumple 43.2 G, Q(5) Q,N,M 57.62 -0.01 -0.09 -0.13 -0.03 Cumple
SUBSUELO 25x50 Arranque N.P. (1)
N.P. (1)
N.P. (2)
43.2 N.P. (1)
Cumple 43.2 G, Q(5) N,M 57.62 -0.01 -0.09 -0.13 -0.03 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
1.2·PP+1.2·CM+1.6·Qa

1.22. C22

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 17.6 18.1 N.P.(3) Cumple 18.1 G, Q(4) Q,N,M 7.23 -1.28 0.67 -0.84 -0.92 Cumple
P10 (27.3 - 30.1 m) 20x60
Pie Cumple Cumple 26.3 40.6 N.P.(3) Cumple 40.6 G, Q(4) Q,N,M 8.09 -3.48 -1.34 -0.84 -0.92 Cumple
Cabeza Cumple Cumple 30.9 62.6 N.P.(3) Cumple 62.6 G, Q(4) Q,N,M 29.79 6.44 1.55 -1.11 -3.48 Cumple
P9 (24.5 - 27.3 m) 20x60
Pie Cumple Cumple 30.7 35.6 N.P. (3)
Cumple 35.6 G, Q(4) Q,N,M 30.65 -1.90 -1.12 -1.11 -3.48 Cumple
Cabeza Cumple Cumple 16.1 37.7 N.P.(3) Cumple 37.7 G, Q(4) Q,N,M 38.59 -2.79 0.62 -0.54 1.94 Cumple
P8 (21.7 - 24.5 m) 20x60
Pie Cumple Cumple 16.0 35.4 N.P.(3) Cumple 35.4 G, Q(4) Q,N,M 39.46 1.88 -0.68 -0.54 1.94 Cumple
Cabeza Cumple Cumple 8.2 39.4 N.P.(3) Cumple 39.4 G, Q(4) Q,N,M 47.00 -0.92 0.84 -0.71 0.88 Cumple
P7 (19 - 21.7 m) 20x60
Pie Cumple Cumple 8.2 40.5 N.P.(3) Cumple 40.5 G, Q(4) Q,N,M 47.83 1.09 -0.80 -0.71 0.88 Cumple
Cabeza Cumple Cumple 8.6 47.1 N.P.(3) Cumple 47.1 G, Q(4) Q,N,M 55.34 -1.21 0.80 -0.69 1.01 Cumple
P6 (16.3 - 19 m) 20x60
Pie Cumple Cumple 8.6 47.7 N.P.(3) Cumple 47.7 G, Q(4) Q,N,M 56.17 1.12 -0.78 -0.69 1.01 Cumple
Cabeza Cumple Cumple 7.3 54.2 N.P.(3) Cumple 54.2 G, Q(4) Q,N,M 63.76 -0.98 0.82 -0.70 0.84 Cumple
P5 (13.6 - 16.3 m) 20x60
Pie Cumple Cumple 7.3 54.9 N.P.(3) Cumple 54.9 G, Q(4) Q,N,M 64.59 0.95 -0.79 -0.70 0.84 Cumple
G, Q, S(5) Q S. 45.40 -0.93 0.66 -0.57 0.84
Cabeza Cumple Cumple 6.6 61.8 N.P.(3) Cumple 61.8 Cumple
G, Q(4) N,M 72.23 -0.87 0.83 -0.71 0.72
P4 (10.9 - 13.6 m) 20x60
G, Q, S(5) Q S. 46.25 0.98 -0.65 -0.57 0.82
Pie Cumple Cumple 6.5 62.5 N.P.(3) Cumple 62.5 Cumple
G, Q(4) N,M 73.06 0.80 -0.80 -0.71 0.72
G, Q, S (5)
Q S. 50.76 -0.78 0.64 -0.57 0.77
Cabeza Cumple Cumple 6.1 69.7 N.P.(3) Cumple 69.7 Cumple
G, Q(4) N,M 80.79 -0.74 0.86 -0.73 0.62
P3 (8.2 - 10.9 m) 20x60
G, Q, S (5)
Q S. 50.97 0.95 -0.73 -0.61 0.72
Pie Cumple Cumple 5.9 70.4 N.P.(3) Cumple 70.4 Cumple
G, Q(4) N,M 81.62 0.69 -0.81 -0.73 0.62
Cabeza Cumple Cumple 5.5 77.9 N.P.(3) Cumple 77.9 G, Q(4) Q,N,M 89.30 -0.66 0.91 -0.78 0.55 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 5.5 78.7 N.P.(3) Cumple 78.7 G, Q(4) Q,N,M 90.13 0.61 -0.89 -0.78 0.55 Cumple
P1 (2.7 - 5.5 m) 20x60 Cabeza Cumple Cumple 4.3 88.0 N.P.(3) Cumple 88.0 G, Q(4) Q,N,M 97.89 -0.44 0.87 -0.71 0.35 Cumple

Página 21
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Pie Cumple Cumple 4.3 89.0 N.P.(3) Cumple 89.0 G, Q(4) Q,N,M 98.76 0.39 -0.82 -0.71 0.35 Cumple
Cabeza Cumple Cumple 4.5 95.5 N.P.(3) Cumple 95.5 G, Q(4) Q,N,M 106.54 -0.29 0.94 -0.82 0.24 Cumple
ENTREPISO (0 - 2.7 m) 20x60
Pie Cumple Cumple 4.5 96.6 N.P.(3) Cumple 96.6 G, Q(4) Q,N,M 107.37 0.26 -0.96 -0.82 0.24 Cumple
Cabeza Cumple Cumple 2.7 97.5 N.P.(3) Cumple 97.5 G, Q(4) Q,N,M 115.24 -0.05 0.79 -0.55 0.05 Cumple
PB (-2.66 - 0 m) 20x60
Pie Cumple Cumple 2.7 98.4 N.P.(3) Cumple 98.4 G, Q(4) Q,N,M 116.05 0.07 -0.45 -0.55 0.05 Cumple
SUBSUELO 20x60 Arranque N.P.(1) N.P.(1) N.P.(2) 98.4 N.P.(1) Cumple 98.4 G, Q(4) N,M 116.05 0.07 -0.45 -0.55 0.05 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa
(5)
1.245·PP+1.245·CM+0.5·Qa-SY

1.23. C23

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 47.8 41.7 N.P.(3) Cumple 47.8 G, Q(4) Q,N,M 4.61 -1.07 -2.30 2.29 -0.31 Cumple
P10 (27.3 - 30.1 m) 25x50
Pie Cumple Cumple 48.7 66.7 N.P. (3)
Cumple 66.7 G, Q(4) Q,N,M 5.57 -1.86 3.55 2.29 -0.31 Cumple
27.3 m N.P.(1) N.P.(1) N.P.(2) 66.7 N.P.(1) Cumple 66.7 G, Q(4) N,M 5.57 -1.86 3.55 2.29 -0.31 Cumple
P9 (24.5 - 27.3 m) 25x50 Cabeza Cumple Cumple 48.7 62.5 N.P.(3) Cumple 62.5 G, Q(4) Q,N,M 17.95 3.40 -3.36 2.28 -1.67 Cumple
Pie Cumple Cumple 44.3 39.1 N.P.(3) Cumple 44.3 G, Q(4) Q,N,M 18.90 -0.87 2.44 2.28 -1.67 Cumple
24.5 m N.P. (1)
N.P. (1)
N.P. (2)
39.1 N.P. (1)
Cumple 39.1 G, Q(4) N,M 18.90 -0.87 2.44 2.28 -1.67 Cumple
P8 (21.7 - 24.5 m) 25x50 Cabeza Cumple Cumple 12.2 30.9 N.P.(3) Cumple 30.9 G, Q(4) Q,N,M 25.03 -1.40 -1.46 1.24 0.86 Cumple
Pie Cumple Cumple 12.1 32.3 N.P.(3) Cumple 32.3 G, Q(4) Q,N,M 25.99 0.79 1.71 1.24 0.86 Cumple
Cabeza Cumple Cumple 12.4 36.2 N.P.(3) Cumple 36.2 G, Q(4) Q,N,M 31.97 -0.22 -1.95 1.58 0.24 Cumple
P7 (19 - 21.7 m) 25x50
Pie Cumple Cumple 12.4 36.3 N.P.(3) Cumple 36.3 G, Q(4) Q,N,M 32.89 0.36 1.91 1.58 0.24 Cumple
Cabeza Cumple Cumple 11.3 37.7 N.P.(3) Cumple 37.7 G, Q(4) Q,N,M 38.87 -0.45 -1.78 1.47 0.35 Cumple
P6 (16.3 - 19 m) 25x50
Pie Cumple Cumple 11.2 38.7 N.P.(3) Cumple 38.7 G, Q(4) Q,N,M 39.79 0.40 1.83 1.47 0.35 Cumple
Cabeza Cumple Cumple 10.8 41.4 N.P.(3) Cumple 41.4 G, Q(4) Q,N,M 45.73 -0.34 -1.79 1.48 0.28 Cumple
P5 (13.6 - 16.3 m) 25x50
Pie Cumple Cumple 10.7 42.2 N.P.(3) Cumple 42.2 G, Q(4) Q,N,M 46.65 0.33 1.83 1.48 0.28 Cumple
Cabeza Cumple Cumple 10.2 44.5 N.P.(3) Cumple 44.5 G, Q(4) Q,N,M 52.58 -0.31 -1.76 1.45 0.24 Cumple
P4 (10.9 - 13.6 m) 25x50
Pie Cumple Cumple 10.1 45.5 N.P.(3) Cumple 45.5 G, Q(4) Q,N,M 53.50 0.28 1.81 1.45 0.24 Cumple
Cabeza Cumple Cumple 9.6 48.2 N.P.(3) Cumple 48.2 G, Q(4) Q,N,M 59.39 -0.28 -1.72 1.43 0.19 Cumple
P3 (8.2 - 10.9 m) 25x50
Pie Cumple Cumple 9.6 49.2 N.P.(3) Cumple 49.2 G, Q(4) Q,N,M 60.31 0.19 1.78 1.43 0.19 Cumple
Cabeza Cumple Cumple 9.2 51.9 N.P.(3) Cumple 51.9 G, Q(4) Q,N,M 66.17 -0.29 -1.68 1.41 0.22 Cumple
P2 (5.5 - 8.2 m) 25x50
Pie Cumple Cumple 9.2 53.2 N.P.(3) Cumple 53.2 G, Q(4) Q,N,M 67.08 0.26 1.77 1.41 0.22 Cumple
Cabeza Cumple Cumple 8.1 55.7 N.P.(3) Cumple 55.7 G, Q(4) Q,N,M 72.90 -0.13 -1.64 1.28 0.10 Cumple
P1 (2.7 - 5.5 m) 25x50
Pie Cumple Cumple 8.0 56.5 N.P.(3) Cumple 56.5 G, Q(4) Q,N,M 73.86 0.13 1.63 1.28 0.10 Cumple
Cabeza Cumple Cumple 8.9 60.8 N.P.(3) Cumple 60.8 G, Q(4) Q,N,M 79.64 -0.09 -1.69 1.46 0.08 Cumple
ENTREPISO (0 - 2.7 m) 25x50
Pie Cumple Cumple 8.9 62.3 N.P.(3) Cumple 62.3 G, Q(4) Q,N,M 80.56 0.11 1.88 1.46 0.08 Cumple
Cabeza Cumple Cumple 5.6 66.1 N.P.(3) Cumple 66.1 G, Q(4) Q,N,M 86.28 0.04 -1.43 0.94 0.00 Cumple
PB (-2.66 - 0 m) 25x50
Pie Cumple Cumple 5.6 66.8 N.P.(3) Cumple 66.8 G, Q(4) Q,N,M 87.19 0.04 0.83 0.94 0.00 Cumple
SUBSUELO 25x50 Arranque N.P.(1) N.P.(1) N.P.(2) 66.8 N.P.(1) Cumple 66.8 G, Q(4) N,M 87.19 0.04 0.83 0.94 0.00 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

Página 22
Comprobaciones E.L.U.
PROYECTO HORMIGON

1.24. C24

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 16.9 9.0 N.P.(3) Cumple 16.9 G, Q, S(4) Q S.,N,M S. 0.22 -0.20 -0.95 0.88 0.18 Cumple
P8 (21.7 - 24.5 m) 60x20 G, Q, S(4) Q S. 1.12 0.23 1.17 0.88 0.18
Pie Cumple Cumple 16.9 10.6 N.P.(3) Cumple 16.9 Cumple
G, Q, S(4) N,M S. 1.23 0.24 1.21 0.84 0.18
21.7 m N.P.(1) N.P.(1) N.P.(2) 10.6 N.P.(1) Cumple 10.6 G, Q, S(4) N,M S. 1.23 0.24 1.21 0.84 0.18 Cumple
G, S(5) Q S. 0.59 -0.12 -0.44 0.49 0.10
Cabeza Cumple Cumple 8.8 7.6 N.P.(3) Cumple 8.8 Cumple
P7 (19 - 21.7 m) 60x20 G, Q(6) N,M 4.65 -0.35 0.15 -0.01 0.31
G, S(7) Q S. 0.40 0.08 0.73 0.50 0.07
Pie Cumple Cumple 9.6 7.9 N.P.(3) Cumple 9.6 Cumple
G, Q(6) N,M 5.48 0.37 0.13 -0.01 0.31
G, S(7) Q S. 0.17 -0.08 -0.57 0.55 0.07
Cabeza Cumple Cumple 10.5 8.7 N.P.(3) Cumple 10.5 Cumple
G, Q(6) N,M 7.68 -0.38 0.03 0.06 0.33
P6 (16.3 - 19 m) 60x20
G, S (7)
Q S. 0.65 0.08 0.75 0.56 0.07
Pie Cumple Cumple 10.7 9.2 N.P.(3) Cumple 10.7 Cumple
G, Q(6) N,M 8.51 0.37 0.17 0.06 0.33
G, S(7) Q S. 0.68 -0.08 -0.62 0.58 0.06
Cabeza Cumple Cumple 10.6 10.0 N.P.(3) Cumple 10.6 Cumple
G, Q(6) N,M 10.76 -0.36 0.14 -0.01 0.30
P5 (13.6 - 16.3 m) 60x20
G, S(7) Q S. 1.23 0.07 0.70 0.54 0.06
Pie Cumple Cumple 9.9 10.3 N.P.(3) Cumple 10.3 Cumple
G, Q(6) N,M 11.59 0.35 0.13 -0.01 0.30
G, S (7)
Q S. 0.92 -0.07 -0.53 0.57 0.06
Cabeza Cumple Cumple 10.0 11.8 N.P.(3) Cumple 11.8 Cumple
G, Q(6) N,M 13.90 -0.35 0.20 -0.04 0.32
P4 (10.9 - 13.6 m) 60x20
G, S (7)
Q S. 1.51 0.07 0.75 0.53 0.06
Pie Cumple Cumple 9.6 12.4 N.P.(3) Cumple 12.4 Cumple
G, Q(6) N,M 14.72 0.38 0.09 -0.04 0.32
G, S(7) Q S. 1.23 -0.07 -0.22 0.73 0.04
Cabeza Cumple Cumple 7.1 13.8 N.P.(3) Cumple 13.8 Cumple
G, Q(6) N,M 17.06 -0.30 0.28 -0.02 0.21
P3 (8.2 - 10.9 m) 60x20
G, S (7)
Q S. 1.82 0.03 1.45 0.73 0.04
Pie Cumple Cumple 14.1 16.3 N.P.(3) Cumple 16.3 Cumple
G, Q, S(8) N,M S. 16.89 0.12 -1.27 -0.75 0.12
G, S(7) Q S. 2.22 0.00 0.70 -0.32 0.00
Cabeza Cumple Cumple 5.5 17.6 N.P.(3) Cumple 17.6 Cumple
G, Q(6) N,M 21.58 -0.03 0.40 -0.20 0.04
P2 (5.5 - 8.2 m) 60x20
G, Q, S(4) Q S. 9.88 0.02 -0.06 -0.39 0.02
Pie Cumple Cumple 3.5 17.9 N.P.(3) Cumple 17.9 Cumple
G, Q(6) N,M 22.40 0.05 -0.06 -0.20 0.04
G, Q, S (8)
Q S. 22.53 -0.05 0.48 -0.36 0.04
Cabeza Cumple Cumple 2.8 21.1 N.P.(3) Cumple 21.1 Cumple
G, Q(6) N,M 26.11 -0.07 0.23 -0.07 0.05
P1 (2.7 - 5.5 m) 60x20
G, Q, S (8)
Q S. 23.43 0.05 -0.37 -0.36 0.04
Pie Cumple Cumple 2.8 21.7 N.P.(3) Cumple 21.7 Cumple
G, Q(6) N,M 26.97 0.06 0.05 -0.07 0.05
G, Q, S(4) Q S. 22.83 -0.03 0.27 -0.28 0.03
Cabeza Cumple Cumple 2.2 24.9 N.P.(3) Cumple 24.9 Cumple
G, Q(6) N,M 30.66 -0.03 0.30 -0.13 0.03
ENTREPISO (0 - 2.7 m) 60x20
G, Q, S (4)
Q S. 23.69 0.03 -0.37 -0.28 0.03
Pie Cumple Cumple 2.2 25.4 N.P.(3) Cumple 25.4 Cumple
G, Q(6) N,M 31.48 0.03 0.00 -0.13 0.03
G, S (7)
Q S. 14.22 0.00 -0.02 -0.25 0.01
Cabeza Cumple Cumple 2.1 28.4 N.P.(3) Cumple 28.4 Cumple
G, Q(6) N,M 35.08 -0.01 0.19 -0.05 0.01
PB (-2.66 - 0 m) 60x20
G, S(7) Q S. 14.80 0.01 -0.58 -0.25 0.01
Pie Cumple Cumple 2.1 29.0 N.P.(3) Cumple 29.0 Cumple
G, Q(6) N,M 35.90 0.01 0.07 -0.05 0.01
SUBSUELO 60x20 Arranque N.P.(1) N.P.(1) N.P.(2) 29.0 N.P.(1) Cumple 29.0 G, Q(6) N,M 35.90 0.01 0.07 -0.05 0.01 Cumple

Página 23
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa+SY
(5)
1.245·PP+1.245·CM+SY
(6)
1.2·PP+1.2·CM+1.6·Qa
(7)
0.855·PP+0.855·CM+SY
(8)
1.245·PP+1.245·CM+0.5·Qa-SY

1.25. C25

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 22.6 13.8 N.P.(3) Cumple 22.6 G, Q, S(4) Q S.,N,M S. 3.30 -0.40 1.45 -1.25 0.42 Cumple
P8 (21.7 - 24.5 m) 60x20
Pie Cumple Cumple 22.1 18.2 N.P.(3) Cumple 22.1 G, Q, S(4) Q S.,N,M S. 4.20 0.62 -1.54 -1.25 0.42 Cumple
G, S(5) Q S. 2.88 -0.41 0.80 -0.77 0.35
Cabeza Cumple Cumple 14.2 20.2 N.P.(3) Cumple 20.2 Cumple
G, Q(6) N,M 13.99 -0.89 0.41 -0.33 0.75
P7 (19 - 21.7 m) 60x20
G, S(5) Q S. 3.47 0.39 -0.98 -0.77 0.35
Pie Cumple Cumple 14.2 19.4 N.P.(3) Cumple 19.4 Cumple
G, Q(6) N,M 14.81 0.84 -0.34 -0.33 0.75
G, Q, S (4)
Q S. 11.26 -0.60 1.19 -1.05 0.52
Cabeza Cumple Cumple 10.0 21.8 N.P.(3) Cumple 21.8 Cumple
G, Q(6) N,M 21.22 -0.76 0.72 -0.52 0.66
P6 (16.3 - 19 m) 60x20
G, Q, S (4)
Q S. 12.12 0.60 -1.22 -1.05 0.52
Pie Cumple Cumple 10.0 21.6 N.P.(3) Cumple 21.6 Cumple
G, Q(6) N,M 22.05 0.75 -0.48 -0.52 0.66
G, Q, S(4) Q S. 15.66 -0.59 1.27 -1.05 0.51
Cabeza Cumple Cumple 9.6 24.9 N.P.(3) Cumple 24.9 Cumple
G, Q(6) N,M 28.31 -0.71 0.77 -0.56 0.61
P5 (13.6 - 16.3 m) 60x20
G, Q, S (4)
Q S. 16.46 0.57 -1.15 -1.03 0.50
Pie Cumple Cumple 9.4 24.8 N.P.(3) Cumple 24.8 Cumple
G, Q(6) N,M 29.14 0.69 -0.53 -0.56 0.61
G, Q, S (4)
Q S. 19.39 -0.54 1.27 -1.11 0.47
Cabeza Cumple Cumple 9.7 29.6 N.P.(3) Cumple 29.6 Cumple
G, Q(6) N,M 35.26 -0.64 0.88 -0.64 0.55
P4 (10.9 - 13.6 m) 60x20
G, Q, S(4) Q S. 20.32 0.53 -1.26 -1.07 0.46
Pie Cumple Cumple 9.3 29.8 N.P.(3) Cumple 29.8 Cumple
G, Q(6) N,M 36.09 0.63 -0.59 -0.64 0.55
G, Q, S (4)
Q S. 23.23 -0.46 1.05 -1.26 0.40
Cabeza Cumple Cumple 10.4 35.5 N.P.(3) Cumple 35.5 Cumple
G, Q(6) N,M 42.06 -0.56 1.02 -0.70 0.46
P3 (8.2 - 10.9 m) 60x20
G, Q, S (4)
Q S. 24.09 0.46 -1.86 -1.26 0.40
Pie Cumple Cumple 10.3 35.4 N.P.(3) Cumple 35.4 Cumple
G, Q(6) N,M 42.89 0.49 -0.58 -0.70 0.46
Cabeza Cumple Cumple 8.0 42.6 N.P.(3) Cumple 42.6 G, Q(6) Q,N,M 49.77 -0.39 1.33 -1.02 0.33 Cumple
P2 (5.5 - 8.2 m) 60x20
Pie Cumple Cumple 8.0 42.7 N.P.(3) Cumple 42.7 G, Q(6) Q,N,M 50.60 0.37 -1.02 -1.02 0.33 Cumple
G, Q, S(4) Q S. 32.00 -0.27 1.07 -0.84 0.22
Cabeza Cumple Cumple 6.4 49.2 N.P.(3) Cumple 49.2 Cumple
G, Q(6) N,M 57.39 -0.30 1.17 -0.85 0.23
P1 (2.7 - 5.5 m) 60x20
G, Q, S (4)
Q S. 32.90 0.25 -0.95 -0.84 0.22
Pie Cumple Cumple 6.4 49.5 N.P.(3) Cumple 49.5 Cumple
G, Q(6) N,M 58.26 0.26 -0.87 -0.85 0.23
Cabeza Cumple Cumple 7.6 55.9 N.P.(3) Cumple 55.9 G, Q(6) Q,N,M 65.05 -0.19 1.33 -1.08 0.16 Cumple
ENTREPISO (0 - 2.7 m) 60x20
Pie Cumple Cumple 7.6 56.5 N.P.(3) Cumple 56.5 G, Q(6) Q,N,M 65.88 0.16 -1.17 -1.08 0.16 Cumple
Cabeza Cumple Cumple 5.0 62.6 N.P.(3) Cumple 62.6 G, Q(6) Q,N,M 72.78 -0.07 1.20 -0.74 0.05 Cumple
PB (-2.66 - 0 m) 60x20
Pie Cumple Cumple 5.0 62.5 N.P.(3) Cumple 62.5 G, Q(6) Q,N,M 73.60 0.05 -0.48 -0.74 0.05 Cumple
SUBSUELO 60x20 Arranque N.P.(1) N.P.(1) N.P.(2) 62.5 N.P.(1) Cumple 62.5 G, Q(6) N,M 73.60 0.05 -0.48 -0.74 0.05 Cumple

Página 24
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
0.855·PP+0.855·CM-SY
(6)
1.2·PP+1.2·CM+1.6·Qa

1.26. C26

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 28.1 26.3 N.P.(3) Cumple 28.1 G, Q(4) Q,N,M 3.95 -1.22 -1.07 1.04 1.01 Cumple
P8 (21.7 - 24.5 m) 20x60
Pie Cumple Cumple 28.2 34.3 N.P. (3)
Cumple 34.3 G, Q(4) Q,N,M 4.82 1.19 1.43 1.04 1.01 Cumple
21.7 m N.P.(1) N.P.(1) N.P.(2) 34.3 N.P.(1) Cumple 34.3 G, Q(4) N,M 4.82 1.19 1.43 1.04 1.01 Cumple
P7 (19 - 21.7 m) 20x60 Cabeza Cumple Cumple 23.9 26.8 N.P.(3) Cumple 26.8 G, Q(4) Q,N,M 9.30 -0.58 -1.35 1.19 0.57 Cumple
Pie Cumple Cumple 23.8 28.0 N.P.(3) Cumple 28.0 G, Q(4) Q,N,M 10.13 0.74 1.38 1.19 0.57 Cumple
Cabeza Cumple Cumple 22.0 29.6 N.P. (3)
Cumple 29.6 G, Q(4) Q,N,M 14.54 -0.87 -1.34 1.18 0.74 Cumple
P6 (16.3 - 19 m) 20x60
Pie Cumple Cumple 22.0 30.0 N.P.(3) Cumple 30.0 G, Q(4) Q,N,M 15.37 0.83 1.36 1.18 0.74 Cumple
Cabeza Cumple Cumple 11.0 30.4 N.P.(3) Cumple 30.4 G, Q(4) Q,N,M 19.74 -0.77 -1.30 1.14 0.67 Cumple
P5 (13.6 - 16.3 m) 20x60
Pie Cumple Cumple 11.0 31.0 N.P.(3) Cumple 31.0 G, Q(4) Q,N,M 20.57 0.76 1.32 1.14 0.67 Cumple
Cabeza Cumple Cumple 10.4 31.5 N.P.(3) Cumple 31.5 G, Q(4) Q,N,M 24.88 -0.78 -1.26 1.11 0.67 Cumple
P4 (10.9 - 13.6 m) 20x60
Pie Cumple Cumple 10.3 32.2 N.P.(3) Cumple 32.2 G, Q(4) Q,N,M 25.71 0.76 1.29 1.11 0.67 Cumple
Cabeza Cumple Cumple 9.3 32.7 N.P. (3)
Cumple 32.7 G, Q(4) Q,N,M 29.97 -0.76 -1.21 1.07 0.57 Cumple
P3 (8.2 - 10.9 m) 20x60
Pie Cumple Cumple 9.3 33.2 N.P.(3) Cumple 33.2 G, Q(4) Q,N,M 30.79 0.55 1.24 1.07 0.57 Cumple
Cabeza Cumple Cumple 8.5 34.4 N.P.(3) Cumple 34.4 G, Q(4) Q,N,M 35.82 -0.63 -1.14 1.01 0.55 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 8.5 35.5 N.P.(3) Cumple 35.5 G, Q(4) Q,N,M 36.65 0.63 1.18 1.01 0.55 Cumple
Cabeza Cumple Cumple 7.0 36.9 N.P. (3)
Cumple 36.9 G, Q(4) Q,N,M 41.64 -0.48 -1.09 0.90 0.40 Cumple
P1 (2.7 - 5.5 m) 20x60
Pie Cumple Cumple 6.9 37.3 N.P.(3) Cumple 37.3 G, Q(4) Q,N,M 42.50 0.48 1.08 0.90 0.40 Cumple
Cabeza Cumple Cumple 7.3 40.3 N.P.(3) Cumple 40.3 G, Q(4) Q,N,M 47.49 -0.46 -1.09 0.99 0.43 Cumple
ENTREPISO (0 - 2.7 m) 20x60
Pie Cumple Cumple 7.3 42.0 N.P.(3) Cumple 42.0 G, Q(4) Q,N,M 48.32 0.54 1.18 0.99 0.43 Cumple
Cabeza Cumple Cumple 4.5 44.1 N.P. (3)
Cumple 44.1 G, Q(4) Q,N,M 53.27 -0.27 -0.90 0.65 0.22 Cumple
PB (-2.66 - 0 m) 20x60
Pie Cumple Cumple 4.5 44.7 N.P.(3) Cumple 44.7 G, Q(4) Q,N,M 54.08 0.24 0.56 0.65 0.22 Cumple
SUBSUELO 20x60 Arranque N.P.(1) N.P.(1) N.P.(2) 44.7 N.P.(1) Cumple 44.7 G, Q(4) N,M 54.08 0.24 0.56 0.65 0.22 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.27. C27

Página 25
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 1.20 0.00 -0.63 0.62 0.00


Cabeza Cumple Cumple 10.7 3.8 N.P.(3) Cumple 10.7 Cumple
P2 (5.5 - 8.2 m) 60x20 G, Q(5) N,M 2.99 -0.03 -0.45 0.41 0.03
Pie Cumple Cumple 10.4 6.6 N.P. (3)
Cumple 10.4 G, Q, S (4)
Q S.,N,M S. 2.07 0.00 0.79 0.61 0.00 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 6.6 N.P.(1) Cumple 6.6 G, Q, S(4) N,M S. 2.07 0.00 0.79 0.61 0.00 Cumple
G, S(6) Q S. 3.57 -0.02 0.31 -0.26 0.02
Cabeza Cumple Cumple 2.5 5.9 N.P. (3)
Cumple 5.9 Cumple
P1 (2.7 - 5.5 m) 60x20 G, Q(5) N,M 7.19 -0.03 0.19 -0.01 0.02
G, S(7) Q S. 1.67 0.00 0.45 0.23 0.00
Pie Cumple Cumple 3.8 6.5 N.P.(3) Cumple 6.5 Cumple
G, Q(5) N,M 8.05 0.02 0.17 -0.01 0.02
G, S (7)
Q S. 4.48 -0.02 0.20 -0.29 0.02
Cabeza Cumple Cumple 2.7 9.2 N.P.(3) Cumple 9.2 Cumple
G, Q(5) N,M 11.55 -0.02 0.11 0.00 0.02
ENTREPISO (0 - 2.7 m) 60x20
G, S (7)
Q S. 5.07 0.02 -0.46 -0.29 0.02
Pie Cumple Cumple 2.7 9.9 N.P.(3) Cumple 9.9 Cumple
G, Q(5) N,M 12.37 0.02 0.11 0.00 0.02
G, S(7) Q S. 6.09 0.00 -0.07 -0.28 0.01
Cabeza Cumple Cumple 2.6 12.7 N.P.(3) Cumple 12.7 Cumple
G, Q(5) N,M 15.90 -0.01 0.13 -0.02 0.00
PB (-2.66 - 0 m) 60x20
G, S (7)
Q S. 6.67 0.01 -0.71 -0.28 0.01
Pie Cumple Cumple 2.6 13.3 N.P.(3) Cumple 13.3 Cumple
G, Q(5) N,M 16.71 0.01 0.08 -0.02 0.00
SUBSUELO 60x20 Arranque N.P. (1)
N.P. (1)
N.P. (2)
13.3 N.P. (1)
Cumple 13.3 G, Q (5)
N,M 16.71 0.01 0.08 -0.02 0.00 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa+SY
(5)
1.2·PP+1.2·CM+1.6·Qa
(6)
1.245·PP+1.245·CM+SY
(7)
0.855·PP+0.855·CM+SY

1.28. C28

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 4.32 -0.10 1.13 -1.02 0.12


Cabeza Cumple Cumple 17.0 11.0 N.P.(3) Cumple 17.0 Cumple
G, Q(5) N,M 8.19 -0.09 1.18 -0.96 0.10
P2 (5.5 - 8.2 m) 60x20
G, S (6)
Q S. 3.51 0.14 -0.99 -0.81 0.10
Pie Cumple Cumple 13.6 10.1 N.P.(3) Cumple 13.6 Cumple
G, Q(5) N,M 9.02 0.15 -1.03 -0.96 0.10
G, Q, S(7) Q S. 8.98 -0.16 0.76 -0.66 0.13
Cabeza Cumple Cumple 6.0 14.4 N.P.(3) Cumple 14.4 Cumple
G, Q(5) N,M 16.43 -0.14 0.79 -0.60 0.11
P1 (2.7 - 5.5 m) 60x20
G, Q, S(7) Q S. 9.87 0.15 -0.82 -0.66 0.13
Pie Cumple Cumple 6.0 14.7 N.P.(3) Cumple 14.7 Cumple
G, Q(5) N,M 17.30 0.13 -0.64 -0.60 0.11
ENTREPISO (0 - 2.7 m) 60x20 Cabeza Cumple Cumple 9.2 21.9 N.P. (3)
Cumple 21.9 G, Q (5)
Q,N,M 24.51 -0.09 1.26 -1.03 0.08 Cumple
Pie Cumple Cumple 9.1 22.1 N.P.(3) Cumple 22.1 G, Q(5) Q,N,M 25.33 0.08 -1.11 -1.03 0.08 Cumple
Cabeza Cumple Cumple 5.9 27.8 N.P.(3) Cumple 27.8 G, Q(5) Q,N,M 32.46 -0.04 1.12 -0.70 0.03 Cumple
PB (-2.66 - 0 m) 60x20
Pie Cumple Cumple 5.9 27.2 N.P.(3) Cumple 27.2 G, Q(5) Q,N,M 33.27 0.03 -0.46 -0.70 0.03 Cumple
SUBSUELO 60x20 Arranque N.P.(1) N.P.(1) N.P.(2) 27.2 N.P.(1) Cumple 27.2 G, Q(5) N,M 33.27 0.03 -0.46 -0.70 0.03 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
1.2·PP+1.2·CM+1.6·Qa
(6)
1.245·PP+1.245·CM-SY
(7)
1.245·PP+1.245·CM+0.5·Qa+SY

Página 26
Comprobaciones E.L.U.
PROYECTO HORMIGON

1.29. C29

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 18.2 16.9 N.P.(3) Cumple 18.2 G, Q(4) Q,N,M 4.88 -0.21 -0.90 0.92 0.19 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 18.5 24.5 N.P. (3)
Cumple 24.5 G, Q(4) Q,N,M 5.71 0.23 1.22 0.92 0.19 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 24.5 N.P.(1) Cumple 24.5 G, Q(4) N,M 5.71 0.23 1.22 0.92 0.19 Cumple
P1 (2.7 - 5.5 m) 20x60 Cabeza Cumple Cumple 15.5 20.1 N.P.(3) Cumple 20.1 G, Q(4) Q,N,M 10.80 -0.03 -1.02 0.86 0.04 Cumple
Pie Cumple Cumple 15.2 20.9 N.P.(3) Cumple 20.9 G, Q(4) Q,N,M 11.66 0.07 1.04 0.86 0.04 Cumple
Cabeza Cumple Cumple 8.1 23.4 N.P.(3) Cumple 23.4 G, Q(4) Q,N,M 16.68 -0.07 -1.08 0.98 0.08 Cumple
ENTREPISO (0 - 2.7 m) 20x60
Pie Cumple Cumple 8.0 25.2 N.P.(3) Cumple 25.2 G, Q(4) Q,N,M 17.50 0.12 1.16 0.98 0.08 Cumple
0m N.P.(1) N.P.(1) N.P.(2) 25.2 N.P.(1) Cumple 25.2 G, Q(4) N,M 17.50 0.12 1.16 0.98 0.08 Cumple
PB (-2.66 - 0 m) 20x60 Cabeza Cumple Cumple 5.0 22.9 N.P.(3) Cumple 22.9 G, Q(4) Q,N,M 22.40 0.07 -0.89 0.64 -0.01 Cumple
Pie Cumple Cumple 5.0 19.2 N.P.(3) Cumple 19.2 G, Q(4) Q,N,M 23.21 0.05 0.55 0.64 -0.01 Cumple
SUBSUELO 20x60 Arranque N.P.(1) N.P.(1) N.P.(2) 19.2 N.P.(1) Cumple 19.2 G, Q(4) N,M 23.21 0.05 0.55 0.64 -0.01 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.30. C30

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 1.10 0.01 -0.69 0.68 -0.01


Cabeza Cumple Cumple 12.1 4.2 N.P.(3) Cumple 12.1 Cumple
P2 (5.5 - 8.2 m) 60x20 G, S(5) N,M S. 0.45 0.01 -0.60 0.60 -0.01
Pie Cumple Cumple 12.0 7.3 N.P.(3) Cumple 12.0 G, Q, S(4) Q S.,N,M S. 1.96 -0.02 0.88 0.68 -0.01 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 7.3 N.P.(1) Cumple 7.3 G, Q, S(4) N,M S. 1.96 -0.02 0.88 0.68 -0.01 Cumple
G, S(5) Q S. 3.65 -0.01 0.35 -0.31 0.01
Cabeza Cumple Cumple 3.0 5.8 N.P. (3)
Cumple 5.8 Cumple
P1 (2.7 - 5.5 m) 60x20 G, Q(6) N,M 7.09 0.00 0.19 -0.02 0.00
G, S (7)
Q S. 1.56 -0.01 0.48 0.29 -0.01
Pie Cumple Cumple 4.9 6.4 N.P.(3) Cumple 6.4 Cumple
G, Q(6) N,M 7.96 0.00 0.15 -0.02 0.00
G, S(5) Q S. 6.12 -0.01 0.26 -0.35 0.01
Cabeza Cumple Cumple 3.3 9.1 N.P.(3) Cumple 9.1 Cumple
G, Q(6) N,M 11.44 0.00 0.12 -0.02 0.00
ENTREPISO (0 - 2.7 m) 60x20
G, S (7)
Q S. 2.37 -0.01 0.59 0.32 -0.01
Pie Cumple Cumple 5.4 9.7 N.P.(3) Cumple 9.7 Cumple
G, Q(6) N,M 12.27 0.00 0.08 -0.02 0.00
G, S (8)
Q S. 6.31 0.00 -0.09 -0.34 0.00
Cabeza Cumple Cumple 3.1 12.6 N.P.(3) Cumple 12.6 Cumple
G, Q(6) N,M 15.79 0.00 0.11 -0.02 0.00
PB (-2.66 - 0 m) 60x20
G, S(7) Q S. 3.37 -0.01 0.88 0.31 0.00
Pie Cumple Cumple 5.2 13.2 N.P.(3) Cumple 13.2 Cumple
G, Q(6) N,M 16.60 0.00 0.06 -0.02 0.00
SUBSUELO 60x20 Arranque N.P.(1) N.P.(1) N.P.(2) 13.2 N.P.(1) Cumple 13.2 G, Q(6) N,M 16.60 0.00 0.06 -0.02 0.00 Cumple

Página 27
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa+SY
(5)
1.245·PP+1.245·CM+SY
(6)
1.2·PP+1.2·CM+1.6·Qa
(7)
0.855·PP+0.855·CM-SY
(8)
0.855·PP+0.855·CM+SY

1.31. C31

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 18.8 10.4 N.P.(3) Cumple 18.8 G, Q, S(4) Q S.,N,M S. 3.92 -0.04 1.23 -1.12 0.05 Cumple
P2 (5.5 - 8.2 m) 60x20 G, Q, S(4) Q S. 4.78 0.08 -1.35 -1.12 0.05
Pie Cumple Cumple 18.7 10.0 N.P. (3)
Cumple 18.7 Cumple
G, Q(5) N,M 8.47 0.00 -1.07 -0.99 0.00
G, Q, S (6)
Q S. 8.27 -0.08 0.83 -0.73 0.07
Cabeza Cumple Cumple 6.6 13.8 N.P.(3) Cumple 13.8 Cumple
G, Q(5) N,M 15.53 -0.01 0.80 -0.61 0.01
P1 (2.7 - 5.5 m) 60x20
G, Q, S (6)
Q S. 9.17 0.08 -0.92 -0.73 0.07
Pie Cumple Cumple 6.6 14.0 N.P.(3) Cumple 14.0 Cumple
G, Q(5) N,M 16.39 0.01 -0.66 -0.61 0.01
Cabeza Cumple Cumple 9.5 21.2 N.P.(3) Cumple 21.2 G, Q(5) Q,N,M 23.36 -0.01 1.28 -1.06 0.01 Cumple
ENTREPISO (0 - 2.7 m) 60x20
Pie Cumple Cumple 9.4 21.3 N.P.(3) Cumple 21.3 G, Q(5) Q,N,M 24.19 0.02 -1.15 -1.06 0.01 Cumple
Cabeza Cumple Cumple 6.4 26.8 N.P.(3) Cumple 26.8 G, Q, S(6) Q S. 17.14 -0.02 0.56 -0.77 0.03 Cumple
G, Q(5) N,M 31.19 0.00 1.11 -0.71 0.00
PB (-2.66 - 0 m) 60x20
G, Q, S(6) Q S. 17.98 0.04 -1.17 -0.77 0.03
Pie Cumple Cumple 6.3 26.2 N.P.(3) Cumple 26.2 Cumple
G, Q(5) N,M 32.01 0.01 -0.48 -0.71 0.00
SUBSUELO 60x20 Arranque N.P.(1) N.P.(1) N.P.(2) 26.2 N.P.(1) Cumple 26.2 G, Q(5) N,M 32.01 0.01 -0.48 -0.71 0.00 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
1.2·PP+1.2·CM+1.6·Qa
(6)
1.245·PP+1.245·CM+0.5·Qa+SY

1.32. C32

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 17.9 16.8 N.P.(3) Cumple 17.9 G, Q(4) Q,N,M 4.72 -0.05 -0.89 0.91 0.07 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 18.2 24.3 N.P.(3) Cumple 24.3 G, Q(4) Q,N,M 5.55 0.10 1.21 0.91 0.07 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 24.3 N.P.(1) Cumple 24.3 G, Q(4) N,M 5.55 0.10 1.21 0.91 0.07 Cumple
P1 (2.7 - 5.5 m) 20x60 Cabeza Cumple Cumple 15.5 19.8 N.P.(3) Cumple 19.8 G, Q(4) Q,N,M 10.55 -0.01 -1.01 0.85 0.02 Cumple
Pie Cumple Cumple 15.1 20.6 N.P.(3) Cumple 20.6 G, Q(4) Q,N,M 11.41 0.04 1.03 0.85 0.02 Cumple
ENTREPISO (0 - 2.7 m) 20x60 Cabeza Cumple Cumple 8.0 23.1 N.P.(3) Cumple 23.1 G, Q(4) Q,N,M 16.39 -0.04 -1.07 0.97 0.06 Cumple

Página 28
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Pie Cumple Cumple 8.0 25.0 N.P.(3) Cumple 25.0 G, Q(4) Q,N,M 17.22 0.11 1.15 0.97 0.06 Cumple
0m N.P.(1) N.P.(1) N.P.(2) 25.0 N.P.(1) Cumple 25.0 G, Q(4) N,M 17.22 0.11 1.15 0.97 0.06 Cumple
PB (-2.66 - 0 m) 20x60 Cabeza Cumple Cumple 5.0 22.8 N.P.(3) Cumple 22.8 G, Q(4) Q,N,M 22.15 0.06 -0.89 0.64 0.00 Cumple
Pie Cumple Cumple 5.0 19.0 N.P.(3) Cumple 19.0 G, Q(4) Q,N,M 22.96 0.06 0.55 0.64 0.00 Cumple
SUBSUELO 20x60 Arranque N.P. (1)
N.P. (1)
N.P. (2)
19.0 N.P. (1)
Cumple 19.0 G, Q(4) N,M 22.96 0.06 0.55 0.64 0.00 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.33. C33

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 1.09 0.02 -0.75 0.75 -0.02


Cabeza Cumple Cumple 13.3 4.8 N.P.(3) Cumple 13.3 Cumple
P2 (5.5 - 8.2 m) 60x20 G, S(5) N,M S. 0.14 0.01 -0.61 0.63 -0.02
Pie Cumple Cumple 13.3 8.0 N.P. (3)
Cumple 13.3 G, Q, S (4)
Q S.,N,M S. 1.95 -0.03 0.96 0.74 -0.02 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 8.0 N.P.(1) Cumple 8.0 G, Q, S(4) N,M S. 1.95 -0.03 0.96 0.74 -0.02 Cumple
G, S(6) Q S. 0.83 0.01 -0.25 0.34 -0.01
Cabeza Cumple Cumple 5.6 6.0 N.P. (3)
Cumple 6.0 Cumple
P1 (2.7 - 5.5 m) 60x20 G, Q(7) N,M 7.29 0.01 0.21 -0.03 -0.01
G, S(6) Q S. 1.45 -0.01 0.55 0.34 -0.01
Pie Cumple Cumple 5.9 6.5 N.P.(3) Cumple 6.5 Cumple
G, Q(7) N,M 8.15 -0.01 0.13 -0.03 -0.01
G, S (8)
Q S. 6.45 -0.01 0.29 -0.42 0.01
Cabeza Cumple Cumple 3.8 9.3 N.P.(3) Cumple 9.3 Cumple
G, Q(7) N,M 11.71 0.01 0.14 -0.04 -0.01
ENTREPISO (0 - 2.7 m) 60x20
G, S (6)
Q S. 2.19 -0.02 0.68 0.37 -0.01
Pie Cumple Cumple 6.2 9.9 N.P.(3) Cumple 9.9 Cumple
G, Q(7) N,M 12.54 -0.01 0.05 -0.04 -0.01
G, S(5) Q S. 6.67 0.00 -0.12 -0.39 0.00
Cabeza Cumple Cumple 3.6 12.8 N.P.(3) Cumple 12.8 Cumple
G, Q(7) N,M 16.13 0.01 0.10 -0.03 -0.01
PB (-2.66 - 0 m) 60x20
G, S (6)
Q S. 3.14 -0.01 1.01 0.36 -0.01
Pie Cumple Cumple 6.5 13.5 N.P.(3) Cumple 13.5 Cumple
G, Q(7) N,M 16.94 -0.01 0.04 -0.03 -0.01
SUBSUELO 60x20 Arranque N.P.(1) N.P.(1) N.P.(2) 13.5 N.P.(1) Cumple 13.5 G, Q(7) N,M 16.94 -0.01 0.04 -0.03 -0.01 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa+SY
(5)
0.855·PP+0.855·CM+SY
(6)
0.855·PP+0.855·CM-SY
(7)
1.2·PP+1.2·CM+1.6·Qa
(8)
1.245·PP+1.245·CM+SY

1.34. C34

Página 29
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 3.99 -0.05 1.34 -1.24 0.06


Cabeza Cumple Cumple 20.8 11.3 N.P.(3) Cumple 20.8 Cumple
G, Q(5) N,M 7.85 -0.01 1.24 -1.03 0.01
P2 (5.5 - 8.2 m) 60x20
G, Q, S (4)
Q S. 4.85 0.09 -1.51 -1.24 0.06
Pie Cumple Cumple 20.7 10.4 N.P.(3) Cumple 20.7 Cumple
G, Q(5) N,M 8.68 0.02 -1.13 -1.03 0.01
G, Q, S(6) Q S. 8.32 -0.08 0.90 -0.81 0.07
Cabeza Cumple Cumple 7.3 14.1 N.P.(3) Cumple 14.1 Cumple
G, Q(5) N,M 15.82 -0.01 0.83 -0.63 0.01
P1 (2.7 - 5.5 m) 60x20
G, Q, S(6) Q S. 9.22 0.08 -1.03 -0.81 0.07
Pie Cumple Cumple 7.3 14.3 N.P.(3) Cumple 14.3 Cumple
G, Q(5) N,M 16.68 0.01 -0.69 -0.63 0.01
Cabeza Cumple Cumple 9.7 21.5 N.P. (3)
Cumple 21.5 G, Q (5)
Q,N,M 23.71 -0.01 1.31 -1.09 0.01 Cumple
ENTREPISO (0 - 2.7 m) 60x20
Pie Cumple Cumple 9.7 21.7 N.P.(3) Cumple 21.7 G, Q(5) Q,N,M 24.54 0.01 -1.20 -1.09 0.01 Cumple
G, Q, S(6) Q S. 17.15 -0.02 0.55 -0.83 0.03
Cabeza Cumple Cumple 6.9 27.1 N.P.(3) Cumple 27.1 Cumple
G, Q(5) N,M 31.59 0.00 1.11 -0.72 0.00
PB (-2.66 - 0 m) 60x20
G, Q, S(6) Q S. 17.98 0.04 -1.33 -0.83 0.03
Pie Cumple Cumple 6.9 26.6 N.P.(3) Cumple 26.6 Cumple
G, Q(5) N,M 32.41 0.00 -0.51 -0.72 0.00
SUBSUELO 60x20 Arranque N.P. (1)
N.P. (1)
N.P. (2)
26.6 N.P. (1)
Cumple 26.6 G, Q (5)
N,M 32.41 0.00 -0.51 -0.72 0.00 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
1.2·PP+1.2·CM+1.6·Qa
(6)
1.245·PP+1.245·CM+0.5·Qa+SY

1.35. C35

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 17.8 16.5 N.P.(3) Cumple 17.8 G, Q(4) Q,N,M 4.78 -0.04 -0.89 0.91 0.05 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 18.1 23.9 N.P. (3)
Cumple 23.9 G, Q(4) Q,N,M 5.61 0.08 1.20 0.91 0.05 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 23.9 N.P.(1) Cumple 23.9 G, Q(4) N,M 5.61 0.08 1.20 0.91 0.05 Cumple
P1 (2.7 - 5.5 m) 20x60 Cabeza Cumple Cumple 15.3 19.8 N.P.(3) Cumple 19.8 G, Q(4) Q,N,M 10.64 0.01 -1.01 0.85 0.00 Cumple
Pie Cumple Cumple 15.0 20.5 N.P.(3) Cumple 20.5 G, Q(4) Q,N,M 11.51 0.02 1.02 0.85 0.00 Cumple
Cabeza Cumple Cumple 8.0 23.1 N.P.(3) Cumple 23.1 G, Q(4) Q,N,M 16.52 -0.02 -1.07 0.96 0.05 Cumple
ENTREPISO (0 - 2.7 m) 20x60
Pie Cumple Cumple 7.9 24.8 N.P.(3) Cumple 24.8 G, Q(4) Q,N,M 17.35 0.09 1.15 0.96 0.05 Cumple
0m N.P.(1) N.P.(1) N.P.(2) 24.8 N.P.(1) Cumple 24.8 G, Q(4) N,M 17.35 0.09 1.15 0.96 0.05 Cumple
PB (-2.66 - 0 m) 20x60 Cabeza Cumple Cumple 5.0 22.9 N.P.(3) Cumple 22.9 G, Q(4) Q,N,M 22.31 0.07 -0.89 0.63 -0.01 Cumple
Pie Cumple Cumple 5.0 19.1 N.P.(3) Cumple 19.1 G, Q(4) Q,N,M 23.13 0.05 0.54 0.63 -0.01 Cumple
SUBSUELO 20x60 Arranque N.P.(1) N.P.(1) N.P.(2) 19.1 N.P.(1) Cumple 19.1 G, Q(4) N,M 23.13 0.05 0.54 0.63 -0.01 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.36. C36

Página 30
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 1.01 0.00 -0.81 0.81 0.00


Cabeza Cumple Cumple 14.6 5.4 N.P.(3) Cumple 14.6 Cumple
P2 (5.5 - 8.2 m) 60x20 G, S(5) N,M S. 0.07 0.01 -0.68 0.70 -0.01
Pie Cumple Cumple 14.6 8.8 N.P. (3)
Cumple 14.6 G, Q, S (4)
Q S.,N,M S. 1.88 -0.01 1.04 0.80 0.00 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 8.8 N.P.(1) Cumple 8.8 G, Q, S(4) N,M S. 1.88 -0.01 1.04 0.80 0.00 Cumple
G, S(6) Q S. 0.69 0.01 -0.29 0.38 -0.01
Cabeza Cumple Cumple 6.4 6.1 N.P. (3)
Cumple 6.4 Cumple
P1 (2.7 - 5.5 m) 60x20 G, Q(7) N,M 7.31 -0.01 0.22 -0.05 0.01
G, S(6) Q S. 1.30 -0.01 0.62 0.38 -0.01
Pie Cumple Cumple 7.0 6.6 N.P.(3) Cumple 7.0 Cumple
G, Q, S(8) N,M S. 6.49 0.02 -0.60 -0.40 0.01
G, S (9)
Q S. 6.72 -0.01 0.33 -0.48 0.02
Cabeza Cumple Cumple 4.4 9.4 N.P.(3) Cumple 9.4 Cumple
G, Q(7) N,M 11.77 -0.02 0.16 -0.07 0.02
ENTREPISO (0 - 2.7 m) 60x20
G, S (6)
Q S. 1.97 -0.01 0.77 0.42 -0.01
Pie Cumple Cumple 7.6 10.0 N.P.(3) Cumple 10.0 Cumple
G, Q(7) N,M 12.60 0.02 0.01 -0.07 0.02
G, S(5) Q S. 6.98 0.00 -0.14 -0.44 0.01
Cabeza Cumple Cumple 4.1 12.9 N.P.(3) Cumple 12.9 Cumple
PB (-2.66 - 0 m) 60x20 G, Q(7) N,M 16.20 -0.01 0.10 -0.03 0.01
Pie Cumple Cumple 7.8 13.5 N.P. (3)
Cumple 13.5 G, S (6)
Q S. 2.89 -0.01 1.15 0.41 0.00 Cumple
G, Q(7) N,M 17.01 0.01 0.02 -0.03 0.01
SUBSUELO 60x20 Arranque N.P.(1) N.P.(1) N.P.(2) 13.5 N.P.(1) Cumple 13.5 G, Q(7) N,M 17.01 0.01 0.02 -0.03 0.01 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa+SY
(5)
0.855·PP+0.855·CM+SY
(6)
0.855·PP+0.855·CM-SY
(7)
1.2·PP+1.2·CM+1.6·Qa
(8)
1.245·PP+1.245·CM+0.5·Qa-SY
(9)
1.245·PP+1.245·CM+SY

1.37. C37

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 22.8 12.2 N.P.(3) Cumple 22.8 G, Q, S(4) Q S.,N,M S. 3.93 -0.05 1.45 -1.36 0.06 Cumple
P2 (5.5 - 8.2 m) 60x20 G, Q, S(4) Q S. 4.79 0.09 -1.68 -1.36 0.06
Pie Cumple Cumple 22.7 10.6 N.P. (3)
Cumple 22.7 Cumple
G, Q(5) N,M 8.67 0.02 -1.18 -1.07 0.02
G, Q, S(6) Q S. 8.17 -0.09 0.98 -0.89 0.08
Cabeza Cumple Cumple 8.0 14.2 N.P.(3) Cumple 14.2 Cumple
G, Q(5) N,M 15.79 -0.03 0.85 -0.66 0.02
P1 (2.7 - 5.5 m) 60x20
G, S(7) Q S. 3.71 0.08 -0.96 -0.65 0.07
Pie Cumple Cumple 10.8 14.4 N.P.(3) Cumple 14.4 Cumple
G, Q(5) N,M 16.66 0.03 -0.72 -0.66 0.02
G, Q, S (6)
Q S. 12.43 -0.08 1.14 -1.19 0.07
Cabeza Cumple Cumple 10.3 21.6 N.P.(3) Cumple 21.6 Cumple
G, Q(5) N,M 23.68 -0.03 1.33 -1.12 0.02
ENTREPISO (0 - 2.7 m) 60x20
G, Q, S (6)
Q S. 13.28 0.08 -1.59 -1.19 0.07
Pie Cumple Cumple 10.2 21.8 N.P.(3) Cumple 21.8 Cumple
G, Q(5) N,M 24.50 0.03 -1.24 -1.12 0.02
G, Q, S(6) Q S. 16.87 -0.03 0.53 -0.89 0.03
Cabeza Cumple Cumple 7.5 27.1 N.P.(3) Cumple 27.1 Cumple
G, Q(5) N,M 31.56 -0.01 1.11 -0.72 0.01
PB (-2.66 - 0 m) 60x20
G, Q, S (6)
Q S. 17.72 0.04 -1.49 -0.89 0.03
Pie Cumple Cumple 7.4 26.6 N.P.(3) Cumple 26.6 Cumple
G, Q(5) N,M 32.38 0.01 -0.53 -0.72 0.01
SUBSUELO 60x20 Arranque N.P.(1) N.P.(1) N.P.(2) 26.6 N.P.(1) Cumple 26.6 G, Q(5) N,M 32.38 0.01 -0.53 -0.72 0.01 Cumple

Página 31
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
1.2·PP+1.2·CM+1.6·Qa
(6)
1.245·PP+1.245·CM+0.5·Qa+SY
(7)
0.855·PP+0.855·CM-SY

1.38. C38

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 17.7 16.4 N.P.(3) Cumple 17.7 G, Q(4) Q,N,M 4.75 -0.10 -0.88 0.90 0.10 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 18.0 23.7 N.P.(3) Cumple 23.7 G, Q(4) Q,N,M 5.58 0.14 1.19 0.90 0.10 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 23.7 N.P.(1) Cumple 23.7 G, Q(4) N,M 5.58 0.14 1.19 0.90 0.10 Cumple
P1 (2.7 - 5.5 m) 20x60 Cabeza Cumple Cumple 15.2 19.7 N.P.(3) Cumple 19.7 G, Q(4) Q,N,M 10.60 -0.01 -1.00 0.84 0.02 Cumple
Pie Cumple Cumple 14.9 20.5 N.P.(3) Cumple 20.5 G, Q(4) Q,N,M 11.46 0.05 1.02 0.84 0.02 Cumple
Cabeza Cumple Cumple 8.0 23.0 N.P. (3)
Cumple 23.0 G, Q(4) Q,N,M 16.47 -0.06 -1.06 0.96 0.09 Cumple
ENTREPISO (0 - 2.7 m) 20x60
Pie Cumple Cumple 7.9 24.8 N.P.(3) Cumple 24.8 G, Q(4) Q,N,M 17.30 0.14 1.14 0.96 0.09 Cumple
0m N.P.(1) N.P.(1) N.P.(2) 24.8 N.P.(1) Cumple 24.8 G, Q(4) N,M 17.30 0.14 1.14 0.96 0.09 Cumple
PB (-2.66 - 0 m) 20x60 Cabeza Cumple Cumple 5.0 22.8 N.P.(3) Cumple 22.8 G, Q(4) Q,N,M 22.25 0.04 -0.89 0.63 0.01 Cumple
Pie Cumple Cumple 4.9 19.0 N.P.(3) Cumple 19.0 G, Q(4) Q,N,M 23.06 0.07 0.54 0.63 0.01 Cumple
SUBSUELO 20x60 Arranque N.P.(1) N.P.(1) N.P.(2) 19.0 N.P.(1) Cumple 19.0 G, Q(4) N,M 23.06 0.07 0.54 0.63 0.01 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.39. C39

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 1.02 0.04 -0.88 0.88 -0.03


Cabeza Cumple Cumple 15.9 6.2 N.P.(3) Cumple 15.9 Cumple
P2 (5.5 - 8.2 m) 60x20 G, S(5) N,M S. 0.03 0.02 -0.75 0.77 -0.02
Pie Cumple Cumple 16.0 9.6 N.P. (3)
Cumple 16.0 G, Q, S (4)
Q S.,N,M S. 1.89 -0.04 1.13 0.87 -0.03 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 9.6 N.P.(1) Cumple 9.6 G, Q, S(4) N,M S. 1.89 -0.04 1.13 0.87 -0.03 Cumple
G, S(6) Q S. 0.57 0.01 -0.33 0.43 -0.01
Cabeza Cumple Cumple 7.2 6.2 N.P.(3) Cumple 7.2 Cumple
P1 (2.7 - 5.5 m) 60x20 G, Q(7) N,M 7.46 -0.01 0.23 -0.06 0.00
G, S(6) Q S. 1.18 -0.01 0.69 0.43 -0.01
Pie Cumple Cumple 8.0 7.1 N.P.(3) Cumple 8.0 Cumple
G, Q, S(8) N,M S. 6.73 0.01 -0.69 -0.46 0.01
ENTREPISO (0 - 2.7 m) 60x20 Cabeza Cumple Cumple 5.0 9.6 N.P. (3)
Cumple 9.6 G, Q, S (4)
Q S. 9.27 0.00 0.39 -0.56 0.01 Cumple
G, Q(7) N,M 11.92 0.01 0.17 -0.08 -0.01

Página 32
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, S(6) Q S. 1.77 -0.02 0.85 0.47 -0.01


Pie Cumple Cumple 8.8 10.2 N.P.(3) Cumple 10.2 Cumple
G, Q, S(4) N,M S. 10.13 0.01 -0.88 -0.56 0.01
G, S (5)
Q S. 7.29 0.00 -0.17 -0.50 0.00
Cabeza Cumple Cumple 4.5 13.0 N.P.(3) Cumple 13.0 Cumple
G, Q(7) N,M 16.37 0.02 0.08 -0.04 -0.01
PB (-2.66 - 0 m) 60x20
G, S(6) Q S. 2.65 -0.01 1.28 0.46 -0.01
Pie Cumple Cumple 8.9 14.0 N.P.(3) Cumple 14.0 Cumple
G, Q, S(4) N,M S. 13.40 0.01 -1.29 -0.51 0.00
SUBSUELO 60x20 Arranque N.P. (1)
N.P. (1)
N.P. (2)
14.0 N.P. (1)
Cumple 14.0 G, Q, S (4)
N,M S. 13.40 0.01 -1.29 -0.51 0.00 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa+SY
(5)
0.855·PP+0.855·CM+SY
(6)
0.855·PP+0.855·CM-SY
(7)
1.2·PP+1.2·CM+1.6·Qa
(8)
1.245·PP+1.245·CM+0.5·Qa-SY

1.40. C40

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 24.9 13.0 N.P.(3) Cumple 24.9 G, Q, S(4) Q S.,N,M S. 3.63 -0.08 1.56 -1.48 0.09 Cumple
P2 (5.5 - 8.2 m) 60x20
Pie Cumple Cumple 24.8 11.5 N.P.(3) Cumple 24.8 G, Q, S(4) Q S.,N,M S. 4.50 0.14 -1.81 -1.45 0.09 Cumple
G, S(5) Q S. 2.79 -0.11 0.77 -0.74 0.09
Cabeza Cumple Cumple 12.4 13.7 N.P.(3) Cumple 13.7 Cumple
G, Q(6) N,M 15.12 -0.09 0.86 -0.67 0.07
P1 (2.7 - 5.5 m) 60x20
G, S (5)
Q S. 3.41 0.11 -1.01 -0.74 0.09
Pie Cumple Cumple 12.4 14.0 N.P.(3) Cumple 14.0 Cumple
G, Q(6) N,M 15.99 0.08 -0.75 -0.67 0.07
G, Q, S(7) Q S. 11.56 -0.11 1.20 -1.27 0.10
Cabeza Cumple Cumple 11.1 20.8 N.P.(3) Cumple 20.8 Cumple
G, Q(6) N,M 22.70 -0.08 1.35 -1.14 0.07
ENTREPISO (0 - 2.7 m) 60x20
G, S (5)
Q S. 4.95 0.10 -1.31 -0.90 0.08
Pie Cumple Cumple 15.1 21.3 N.P.(3) Cumple 21.3 Cumple
G, Q(6) N,M 23.53 0.08 -1.28 -1.14 0.07
G, Q, S(7) Q S. 15.82 -0.05 0.51 -0.96 0.05
Cabeza Cumple Cumple 8.1 26.0 N.P.(3) Cumple 26.0 Cumple
G, Q(6) N,M 30.31 -0.04 1.10 -0.73 0.03
PB (-2.66 - 0 m) 60x20
G, Q, S(7) Q S. 16.66 0.06 -1.64 -0.96 0.05
Pie Cumple Cumple 8.0 25.5 N.P.(3) Cumple 25.5 Cumple
G, Q(6) N,M 31.12 0.03 -0.55 -0.73 0.03
SUBSUELO 60x20 Arranque N.P. (1)
N.P. (1)
N.P. (2)
25.5 N.P. (1)
Cumple 25.5 G, Q (6)
N,M 31.12 0.03 -0.55 -0.73 0.03 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
0.855·PP+0.855·CM+SY
(6)
1.2·PP+1.2·CM+1.6·Qa
(7)
1.245·PP+1.245·CM+0.5·Qa+SY

1.41. C41

Página 33
Comprobaciones E.L.U.
PROYECTO HORMIGON

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 17.5 16.1 N.P.(3) Cumple 17.5 G, Q(4) Q,N,M 4.95 0.09 -0.87 0.89 -0.05 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 17.7 22.6 N.P.(3) Cumple 22.6 G, Q(4) Q,N,M 5.78 -0.01 1.18 0.89 -0.05 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 22.6 N.P.(1) Cumple 22.6 G, Q(4) N,M 5.78 -0.01 1.18 0.89 -0.05 Cumple
P1 (2.7 - 5.5 m) 20x60 Cabeza Cumple Cumple 14.7 19.7 N.P.(3) Cumple 19.7 G, Q(4) Q,N,M 10.86 0.00 -0.99 0.83 0.00 Cumple
Pie Cumple Cumple 14.7 20.4 N.P.(3) Cumple 20.4 G, Q(4) Q,N,M 11.73 0.00 1.01 0.83 0.00 Cumple
Cabeza Cumple Cumple 7.8 23.0 N.P.(3) Cumple 23.0 G, Q(4) Q,N,M 16.80 0.03 -1.06 0.95 0.01 Cumple
ENTREPISO (0 - 2.7 m) 20x60
Pie Cumple Cumple 7.8 24.6 N.P.(3) Cumple 24.6 G, Q(4) Q,N,M 17.62 0.05 1.13 0.95 0.01 Cumple
0m N.P.(1) N.P.(1) N.P.(2) 24.6 N.P.(1) Cumple 24.6 G, Q(4) N,M 17.62 0.05 1.13 0.95 0.01 Cumple
PB (-2.66 - 0 m) 20x60 Cabeza Cumple Cumple 5.0 23.0 N.P.(3) Cumple 23.0 G, Q(4) Q,N,M 22.66 0.11 -0.89 0.63 -0.03 Cumple
Pie Cumple Cumple 4.9 19.2 N.P.(3) Cumple 19.2 G, Q(4) Q,N,M 23.47 0.03 0.54 0.63 -0.03 Cumple
SUBSUELO 20x60 Arranque N.P. (1)
N.P. (1)
N.P. (2)
19.2 N.P. (1)
Cumple 19.2 G, Q(4) N,M 23.47 0.03 0.54 0.63 -0.03 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

1.42. C42

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

G, Q, S(4) Q S. 0.59 -0.14 -0.59 0.65 0.13


Cabeza Cumple Cumple 12.0 5.7 N.P.(3) Cumple 12.0 Cumple
P2 (5.5 - 8.2 m) 60x20 G, Q(5) N,M 1.74 -0.29 -0.16 0.14 0.27
Pie Cumple Cumple 12.0 7.3 N.P. (3)
Cumple 12.0 G, Q, S (4)
Q S.,N,M S. 1.46 0.16 0.89 0.64 0.13 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 7.3 N.P.(1) Cumple 7.3 G, Q, S(4) N,M S. 1.46 0.16 0.89 0.64 0.13 Cumple
G, S(6) Q S. 0.54 -0.04 -0.27 0.38 0.03
Cabeza Cumple Cumple 6.3 5.9 N.P. (3)
Cumple 6.3 Cumple
P1 (2.7 - 5.5 m) 60x20 G, Q(5) N,M 4.73 -0.24 0.21 -0.06 0.20
G, S (6)
Q S. 1.16 0.04 0.63 0.38 0.03
Pie Cumple Cumple 7.1 6.3 N.P.(3) Cumple 7.1 Cumple
G, Q, S(7) N,M S. 4.87 0.13 -0.66 -0.41 0.11
G, Q, S (4)
Q S. 6.58 -0.15 0.31 -0.52 0.14
Cabeza Cumple Cumple 4.9 8.0 N.P.(3) Cumple 8.0 Cumple
G, Q(5) N,M 7.83 -0.30 0.23 -0.14 0.26
ENTREPISO (0 - 2.7 m) 60x20
G, S(6) Q S. 1.67 0.05 0.81 0.41 0.04
Pie Cumple Cumple 7.6 8.6 N.P.(3) Cumple 8.6 Cumple
G, Q, S(4) N,M S. 7.44 0.17 -0.88 -0.52 0.14
G, Q, S(4) Q S. 8.95 -0.12 -0.25 -0.50 0.09
Cabeza Cumple Cumple 4.6 8.8 N.P.(3) Cumple 8.8 Cumple
PB (-2.66 - 0 m) 60x20 G, Q(5) N,M 10.84 -0.24 0.08 -0.05 0.17
Pie Cumple Cumple 8.9 12.3 N.P. (3)
Cumple 12.3 G, S (6)
Q S. 2.42 0.02 1.37 0.46 0.03 Cumple
G, Q, S(4) N,M S. 9.84 0.08 -1.40 -0.50 0.09
SUBSUELO 60x20 Arranque N.P.(1) N.P.(1) N.P.(2) 12.3 N.P.(1) Cumple 12.3 G, Q, S(4) N,M S. 9.84 0.08 -1.40 -0.50 0.09 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa+SY
(5)
1.2·PP+1.2·CM+1.6·Qa
(6)
0.855·PP+0.855·CM-SY
(7)
1.245·PP+1.245·CM+0.5·Qa-SY

Página 34
Comprobaciones E.L.U.
PROYECTO HORMIGON

1.43. C43

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 8.8 8.6 N.P.(3) Cumple 8.8 G, Q, S(4) Q S.,N,M S. 3.09 -0.14 0.45 -0.51 0.17 Cumple
P2 (5.5 - 8.2 m) 20x60
Pie Cumple Cumple 9.1 13.7 N.P. (3)
Cumple 13.7 G, Q, S(4) Q S.,N,M S. 3.95 0.25 -0.72 -0.51 0.17 Cumple
Cabeza Cumple Cumple 10.7 14.4 N.P.(3) Cumple 14.4 G, Q, S(4) Q S.,N,M S. 6.60 -0.08 0.75 -0.63 0.11 Cumple
P1 (2.7 - 5.5 m) 20x60
Pie Cumple Cumple 10.4 15.1 N.P.(3) Cumple 15.1 G, Q, S(4) Q S.,N,M S. 7.50 0.18 -0.76 -0.63 0.11 Cumple
G, S(5) Q S. 6.86 -0.08 0.59 -0.53 0.13
Cabeza Cumple Cumple 8.4 16.2 N.P.(3) Cumple 16.2 Cumple
G, Q(6) N,M 18.41 -0.07 0.53 -0.47 0.07
ENTREPISO (0 - 2.7 m) 20x60
G, S (5)
Q S. 7.72 0.20 -0.64 -0.53 0.13
Pie Cumple Cumple 8.4 16.8 N.P.(3) Cumple 16.8 Cumple
G, Q(6) N,M 19.24 0.10 -0.54 -0.47 0.07
G, Q, S(7) Q S. 13.94 0.04 0.44 -0.39 0.09
Cabeza Cumple Cumple 3.0 19.7 N.P.(3) Cumple 19.7 Cumple
G, Q(6) N,M 24.68 0.00 0.42 -0.30 0.01
PB (-2.66 - 0 m) 20x60
G, Q, S (7)
Q S. 14.78 0.24 -0.44 -0.39 0.09
Pie Cumple Cumple 3.0 20.4 N.P.(3) Cumple 20.4 Cumple
G, Q(6) N,M 25.49 0.04 -0.25 -0.30 0.01
SUBSUELO 20x60 Arranque N.P. (1)
N.P. (1)
N.P. (2)
20.4 N.P. (1)
Cumple 20.4 G, Q (6)
N,M 25.49 0.04 -0.25 -0.30 0.01 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.245·PP+1.245·CM+0.5·Qa-SY
(5)
1.245·PP+1.245·CM+SY
(6)
1.2·PP+1.2·CM+1.6·Qa
(7)
1.245·PP+1.245·CM+0.5·Qa+SY

1.44. C44

Sección de hormigón
Comprobaciones Esfuerzos pésimos Estado
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (t) (t·m) (t·m) (t) (t)

Cabeza Cumple Cumple 37.0 14.9 N.P.(3) Cumple 37.0 G, Q(4) Q,N,M 3.81 -0.27 -2.08 1.83 0.26 Cumple
P2 (5.5 - 8.2 m) 60x20
Pie Cumple Cumple 36.2 16.0 N.P.(3) Cumple 36.2 G, Q(4) Q,N,M 4.64 0.32 2.14 1.83 0.26 Cumple
5.5 m N.P.(1) N.P.(1) N.P.(2) 16.0 N.P.(1) Cumple 16.0 G, Q(4) N,M 4.64 0.32 2.14 1.83 0.26 Cumple
P1 (2.7 - 5.5 m) 60x20 Cabeza Cumple Cumple 9.2 9.3 N.P.(3) Cumple 9.3 G, Q(4) Q,N,M 8.66 -0.22 -0.82 0.88 0.19 Cumple
Pie Cumple Cumple 9.1 12.0 N.P.(3) Cumple 12.0 G, Q(4) Q,N,M 9.52 0.23 1.30 0.88 0.19 Cumple
Cabeza Cumple Cumple 12.5 14.3 N.P.(3) Cumple 14.3 G, Q(4) Q,N,M 13.49 -0.27 -1.35 1.26 0.25 Cumple
ENTREPISO (0 - 2.7 m) 60x20
Pie Cumple Cumple 12.4 15.8 N.P.(3) Cumple 15.8 G, Q(4) Q,N,M 14.31 0.29 1.56 1.26 0.25 Cumple
Cabeza Cumple Cumple 7.9 17.1 N.P.(3) Cumple 17.1 G, Q(4) Q,N,M 18.25 -0.21 -1.21 0.84 0.16 Cumple
PB (-2.66 - 0 m) 60x20
Pie Cumple Cumple 7.9 16.2 N.P.(3) Cumple 16.2 G, Q(4) Q,N,M 19.06 0.14 0.68 0.84 0.16 Cumple
SUBSUELO 60x20 Arranque N.P. (1)
N.P. (1)
N.P. (2)
16.2 N.P. (1)
Cumple 16.2 G, Q(4) N,M 19.06 0.14 0.68 0.84 0.16 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
Debido a la categoría de diseño sísmico de la estructura, no se realiza ninguna comprobación en cuanto a criterios de diseño por sismo.
(4)
1.2·PP+1.2·CM+1.6·Qa

Página 35