Está en la página 1de 1

TCO-9000

1126
OBRA
VERSION 01
X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
CONSTRUCCIONES
X
X
X
PLANIFICADAS

X
X
X
X
X
X Carrera 13 # 26A - 47 piso 2
X
X PBX: 339 4111 - Fax: 287 6216

X
X BOGOTA - COLOMBIA
X
X
X
X

NT.min2555.16 X
PROYECTO:

X
X
X
X
X
X
X

X
X

CABEZAL NO. 1
2552.28
N=116835.7876
H:
2551.70
X

N=116835.4862 2551.67F: N=116835.4830


E=104458.5775
X
X

X
X
X
A: G: N=116834.6332 X
E=104456.6235 E=104464.0582
X
E=104458.8029

X
X
X

2554.77 X
X
X

2552.16

X
X
X
N=116832.6244
2553.59
E:
E=104464.5372
D: N=116831.7870
2551.70

X
E=104459.3587
N=116830.2210
B:
E=104457.7456
X

X
C: N=116830.6342

X
E=104459.5838

X
X

X
NT.min2555.50 NT.min2554.60

X
X

X
X

X
X
X

X
CONTIENE:

X
X
X

X
LOCALIZACIÓN
X

X
CABEZALES DE

X
X

X
CABEZAL NO. 2
2552.40 DESCARGA CANAL EL
X

X
H: N=116787.6888

2551.76F: N=116787.7173 2552.10

X
E=104467.1247

A:
N=116787.3874
E=104465.1708
G: N=116786.5344
E=104467.3501 E=104472.4271 CEDRO

X
2554.77
X

OBRAS TEMPORALES

X
2552.61

X
E: N=116784.8867
2553.39 E=104473.0277
D: N=116783.6882
2551.79

X
E=104467.9059
X

N=116782.1222

X
B:
E=104466.2929
C: N=116782.5354

X
E=104468.1311

1- RESOLUCIÓN DE URBANISMO No. RES.16-2-2156 DEL 28 NOV 2016 CON PLANO No. ESCALA: INDICADA
X

X
X
CU2-U274/4-14.

X
2- NOMENCLATURA INDICADA ACORDE AL PLANO DE REFERENCIA.
ARCHIVO:
X

3- EL CONTRATISTA, URBANIZADOR O CONSTRUCTOR DEBERÁ CUMPLIR CON LAS NORMAS Y

X
OBRAS TEMPORALES.dwg
ESPECIFICACIONES VIGENTES DEL ACUEDUCTO DE BOGOTÁ.
4- LA ACEPTACIÓN DE ESTE PROYECTO POR PARTE DEL ACUEDUCTO NO EXIME AL DISEÑADOR FECHA:
X

DIBUJO:

X
NT.min2554.50 DE LA RESPONSABILIDAD QUE SE DERIVE DE LA EJECUCIÓN Y PUESTA EN SERVICIO DE LAS
28-01-2021 A.M.L.R.
NT.min2554.77 REDES QUE LO CONFORMAN, DE ACUERDO A LAS NORMAS VIGENTES.
X

2553.55 5- EL CONTRATISTA, URBANIZADOR O CONSTRUCTOR ETC., DEBERÁ EJECUTAR LOS AMARRES DE

X
2552.82 TIPO PLANIMETRICO UTILIZANDO LOS PUNTOS DE REFERENCIA MAS PRÓXIMOS A LA OBRA Y QUE Convenciones:
PERTENEZCAN AL IGAC. LOCALIZANDO POR COORDENADAS LOS ACCESORIOS INSTALADOS, EN EL
INDICA COORDENADAS DE
X

X
CASO DE ALTIMETRÍA LOS PUNTOS DE AMARRE DEBEN SER LOS NPS O PUNTOS A LOS CUALES
CABEZAL DE DESCARGA
SE LES HA CALCULADO LA COTA POR MÉTODO GEOMÉTRICO.
6- EL URBANIZADOR ASUME TODA LA RESPONSABILIDAD SOBRE LA INFORMACIÓN TOPOGRÁFICA
X

X
NT.min2555.50 CON LA CUAL SE ELABORARON LOS DISEÑOS, POR LO TANTO, UNA VEZ REALIZADO EL
REPLANTEO TOPOGRÁFICO Y SI SE PRESENTAN CAMBIOS SIGNIFICATIVOS SE DEBERÁN AJUSTAR
X

X
CABEZAL NO. 3
LOS DISEÑOS Y CONTAR CON EL AVAL DE LA SUPERVISIÓN DE OBRA DEL ACUEDUCTO DE
H: N=116743.0772
2552.21 BOGOTÁ.
A: N=116742.7758 2552.42 F: N=116742.7725
E=104474.7696
G: N=116741.9228
7- SI DURANTE LA EJECUCIÓN DE LAS OBRAS SE PRESENTAN INTERFERENCIAS CON REDES
X

E=104472.8157
2551.80 E=104480.2504
E=104474.9950

X
SECAS O CON DOMICILIARIAS QUE NO FUERON IDENTIFICADAS EN LA ETAPA DE DISEÑOS, SERÁ
2554.77 ÚNICA Y EXCLUSIVAMENTE RESPONSABILIDAD DE EL URBANIZADOR DAR SOLUCIÓN A LAS MISMAS,
E: N=116739.9853
2552.88
X

2553.26 E=104480.7609
TENIENDO EN CUENTA QUE EN ESTA ETAPA LA INVESTIGACIÓN DE REDES ESTUVO A CARGO DE

X
D: N=116739.0766
E=104475.5508
N=116737.5105 2551.83 EL URBANIZADOR.
B:
E=104473.9378 C: N=116737.9238
E=104475.7760
8- LA COTA MÍNIMA URBANIZABLE DEL PROYECTO DEBERÁ SER MAYOR QUE LAS COTAS
X

X
RASANTES DE LAS VÍAS ADYACENTES Y DE LOS NIVELES DE LOS COLECTORES EXISTENTES EN
DONDE SE REALICE LA DESCARGA, CON EL FIN DE PREVENIR INUNDACIONES DEL PREDIO.
9- LA DIRECCIÓN RED MATRIZ ACUEDUCTO DE LA EAAB-ESP MEDIANTE MEMORANDO INTERNO
X

X
2541001-2019-2937 DEL 4 DE SEPTIEMBRE DE 2019 INDICÓ QUE NO SE CONSIDERA NECESARIO
CONSTRUIR LA SALIDA DE LA RED MATRIZ SOLICITADA EN LA CERTIFICACIÓN DE VIABILIDAD Y
X

X
DISPONIBILIDAD DE SERVICIOS PÚBLICOS 3131003-2017-2473/S-2017-147019 DEL 18 DE
AGOSTO DE 2017 E INFORMA QUE LA SALIDA EN Ø16" DE LA LÍNEA MATRIZ TIBITOC-USAQUEN DE
Ø60" A LA ALTURA DE LA CALLE 166 POR AVENIDA 9 (COSTADOS OCCIDENTAL) CUENTA CON
X

X
DOS VÁLVULAS DE LAS CUALES UNA SE ENCUENTRA CERRADA ACTUALMENTE Y SE PROPONE
NT.min2553.70 ABRIR ESTA VÁLVULA CON PREVIA AUTORIZACIÓN DE LA DRMA.
X

10- LA GERENCIA ZONA 1 MEDIANTE MEMORANDO INTERNO 3131003-2019-2915 DEL 11 DE

X
OCTUBRE DE 2019 INDICA QUE PARA PODER CONTAR CON UN PUNTO DE ALIMENTACIÓN POR
CONTINGENCIA PARA EL CENTRO MÉDICO, ES NECESARIO QUE EL URBANIZADOR ADECUE LA
X

X
SALIDA DE LA RED MATRIZ EXISTENTE EN LA AVENIDA 9 CON CALLE 166, DE TAL MANERA QUE
SE GARANTICE QUE EN EL EVENTO DE REQUERIR SU OPERACIÓN, POR CONTINGENCIA EN EL CONSTRUCCIONES PLANIFICADAS SA
X
CENTRO MÉDICO, LA RED DE DISTRIBUCIÓN OPERE EN LOS RANGOS PERMITIDOS EN LA NORMA

X
X
X
X
X TÉCNICA DE SERVICIOS NS-036.
X
X
X
11- LA PERFORACIÓN EN LAS CÁMARAS DE LAS DOMICILIARIAS NÚMERO 4 Y 5 SE DEBE

X
X
X REALIZAR DE ACUERDO AL DISEÑO ESTRUCTURAL PRESENTADO.
X
12- SE DEBE REALIZAR APIQUES PARA CONFIRMAR LAS COTAS Y LA LOCALIZACIÓN DE LAS
NT.min2553.70
X
X

TUBERÍAS DE ACUEDUCTO Y SE DEBE REALIZAR UNA INSPECCIÓN PARA LAS CÁMARAS DE


X

X
X
X
X
INSPECCIÓN.
DIRECTOR DE INGENIERÍA:
X

13- MEDIANTE EL COMUNICADO S-2019-276168 DEL 24 DE SEPTIEMBRE DE 2019 LA EAAB-ESP


X
X
X
INFORMA LA LAMINA DE AGUA DEL CANAL EL CEDRO A LA ALTURA DEL PROYECTO. Firmado digitalmente por

X
Mario Fernando
X
Mario Fernando Rivera Paez
X
X
14- LAS DOMICILIARIAS SON CAJAS TIPO POZO.
Rivera Paez Fecha: 2021.03.03 08:41:52
X
X
X
15- LAS TUBERÍAS DE LAS DOMICILIARIAS QUE NO CUMPLEN CON LA DISTANCIA VERTICAL MININA -05'00'
X

X
X
X
X
DE LA CLAVE DE LA TUBERÍA A LA RASANTE DE LA VÍA,SEGUN NORMA NS-085 V.4.0 SERÁN Mario Fernando Rivera Paez
X
X PROTEGIDAS DE ACUERDO A LO DISPUESTO EN LA NORMA NS-090
X

16- DURANTE LA FASE DE CONSTRUCCIÓN, CON SUPERVISIÓN DE LA EAB SE VERIFICARA LA


X X
X

INGENIERO DE PROYECTO:
POSIBILIDAD DE CONSTRUIR LA DOMICILIARIA (DOM07-EX98) CON UNA PENDIENTE DEL 2%

Ana Maria López Rovira


17- EL DIMENSIONAMIENTO ESTRUCTURAL DE TODOS LOS ELEMENTOS DE DISEÑO QUE LO
REQUIERAN, SERÁN ENTREGADOS EN LOS PLANOS ESTRUCTURALES.
18- DURANTE LA FASE DE CONSTRUCCIÓN SE DEBERÁN REALIZAR TRABAJOS DE TOPOGRAFIA
PLANTA DE LOCALIZACION PARA EMPALMAR ALTIMETRICAMENTE LA TOPOGRAFIA DEL PROYECTO CON LA TOPOGRAFIA DEL Ana Maria Lopez Rovira
01 RED DE ALCANTARILLADO PLUVIAL
ESTUDIO REALIZADO POR LA DIRECCIÓN GESTIÓN AMBIENTAL DEL SISTEMA HÍDRICO.

ESC: 1:500

CABEZAL NO. 3

CABEZAL NO. 1
2552.28
CABEZAL NO. 2
2552.40
H: N=116787.6888
H: N=116743.0772

N=116835.7876
2551.76
E=104467.1247 2552.10 2552.42
E=104474.7696 2552.21
MODIFICACIONES
H:
2551.67F: N=116835.4830
E=104458.5775 2551.70
A:
N=116787.3874
G:N=116786.5344 F: N=116787.7173
A: N=116742.7758
G: N=116741.9228 F: N=116742.7725 Ver Fecha Observacíones
01 28-01-21 EMISION INICIAL

A:
N=116835.4862
E=104456.6235
G: N=116834.6332
E=104465.1708 E=104467.3501 E=104472.4271
E=104472.8157
2551.80
E=104474.9950 E=104480.2504

E=104458.8029 E=104464.0582

E: N=116739.9853
E: N=116784.8867
N=116832.6244 2553.39 E=104473.0277 D: 2553.26
E=104480.7609

2553.59 E:
E=104464.5372 D: N=116783.6882
N=116739.0766

D: N=116831.7870 2551.79
E= 104467.9059
E=104475.5508
2551.83
2551.70
E=104459.3587
B:
N=116782.1222
B:
N=116737.5105
E=104473.9378
N=116830.2210 E=104466.2929 C: N=116737.9238 Este plano anula al anterior a partir de:
B: C: N=116782.5354 EMISIÓN INICIAL
E=104457.7456 E=104475.7760
C: N=116830.6342 E=104468.1311
E=104459.5838

VALIDO PARA:

CABEZAL NO. 1 CABEZAL NO. 2 CABEZAL NO. 3 COORDINACIÓN


02 RED DE ALCANTARILLADO PLUVIAL
03 RED DE ALCANTARILLADO PLUVIAL
04 RED DE ALCANTARILLADO PLUVIAL
ESC: 1:100 ESC: 1:100 ESC: 1:100
TCO-9000

1126
OBRA
VERSION 01

También podría gustarte