DISEÑO DE ZAPATA AISLADA EXCENTRICA CON CARGA CENTRADA

Margen Derecha
DATOS: MD,ML
Zapata PD, PL
f'c= 210 kg/cm²
Columna s/c = 0.00 kg/m²
f'c= 210 kg/cm²
b= 25 cm Acero Columna g t1 h t1 = 60.00 cm
t= 25 cm 4 Ø 1/2"
Acero Df = 1.20 m
fy= 4200 kg/cm² g t2 h t2 = 0.00 cm
Suelo
Df = 1.2 m
g t1 = hc = 60.00 cm
1860 kg/m³
g t2 = 1860 kg/m³ T
qa = 1.80 kg/cm²
Otros
S/C = 0 kg/m²
PD = 5.2 Tn Ps = 8.67 Tn

S
PL = 3.47 Tn Pu = 13.18 Tn

b
MD = 0.9 Tn - m Ms = 1.51 Tn - m
ML = 0.61 Tn - m Mu = 2.30 Tn - m t
t
T

1.- DIMENSIONAMIENTO DE LA ZAPATA ( Az = S*T )


Cálculo del peralte de la zapata (hc )

ld = 0.08 * Øb * Fy Øb ( 5/8" ) = 1.59 cm


f 'c^.5 ld = 36.87 cm

Tomar ld = 36.87 cm Longitud de desarrollo en compresión

r.e = 7.50 cm
hc = ld + r.e + Øb hc = 45.96 cm
ht = Df - hc Tomar hc = 60.00 cm

ht = 60.00 cm

Cálculo de la presión neta del suelo ( qm )

qm = qa - g t1*h t1 - g t2*h t2 - gc*hc - s/c

qm = 1.54 kg/cm²

Cálculo del área de la zapata ( Az )

A'z = Ps A'z = 5629.87 cm²


qm T'= 75.03 cm
T ' = Az^.5 + ( t - b ) S'= 75.03 cm
2 e= 17.42 cm
S ' = Az^.5 - ( t - b )
2 S= 109.87 cm
e = Ms Tomar S= 110.00 cm
Ps
S = S' + 2*e Lvb = 42.5 cm Lvt y Lvb deben
Lvb =Lvt = S - b Dimens. Lvt = 55 cm ser iguales (Lvb=Lvt)
2 Reales T= 110.00 cm
T = 2*m + t Tomar T= 135.00 cm

USAR S x T = 110 x 135 cm²


Verificación de las presiones ( q 1,2 )

e<T/6
q 1, 2 = Ps * 1 ± 6*e = qm OK !
S*T T

T/6= 22.5 cm > e = 17.42 cm

q1= 1.04 kg/cm² = qm = 1.54 kg/cm² OK !!


q2= 0.13 kg/cm² = qm = 1.54 kg/cm² OK !!

2.- DETERMINACIÓN DE LA REACCIÓN AMPLIFICADA ( qmu )

e = Mu e= 17.43 cm
Pu T/6= 22.50 cm > e = 17.43 cm
T/6
q 1u = 1.57 kg/cm² qmu se toma el mayor valor
e<T/6 q 2u = 0.02 kg/cm²
q 1u, 2u = Pu * 1 ± 6*e
S*T T Tomar qmu = 1.57 kg/cm²

3.- VERIFICACION POR CORTE ( Ø = 0.85 )


Por Flexión: d

Lv = ( T - t ) / 2 Lv = 55.00 cm
Vu = qmu * S * ( Lv - d ) r.e = 7.50 cm
Vc = 0.53 * f 'c^.5 * S * d Øb ( 5/8") = 1.59 cm
Vu = Øvc OK ! d= 50.91 cm qmu
Vu = 706.34 kg
r.e = 7.5 c.m Lv
Øb Vc = 43011.17 kg
d = hc - r.e - Øb Øvc = 36559.49 kg = Vu = 706.34 kg OK !!

Por Punzonamiento:

Vu = Pu - qmu * m * n

Vc = 0.27 * 2 + 4 * f 'c^.5 * bo * d = 1.10 * f 'c^.5 * bo * d d/2


n = b+d

b c
b

d/2
t
b c = lado mayor columna ( t )
lado menor columna ( b ) m = t+d

m=t+d
n=t+b T
bo = 2*m + 2*n
Vu = Øvc OK !
Ps= PD+PL= Kg

qm = kg/m²

0.00 * n = Kg
m

m= 75.91 cm
n= 75.91 cm
Vu = 4132.14 kg

b c= 1
bo = 303.64 cm
Vc = 1.04 * f 'c^.5 * bo * d = 362899.81 kg
Øvc = 308464.84 kg = Vu = 4132.14 kg OK !!

4.- CALCULO DEL REFUERZO LONGITUDINAL ( Ø = 0.90 )


Dirección Mayor:

Lv = ( T - t ) / 2 Lv = 55.00 cm
Mu = qmu * S * Lv² Mu = 261208.75 kg - cm
2
As = Mu / ( Ø * fy * ( d - a/2 ))
a = As * fy / ( 0.85 * f 'c * S )
qmu

As mín = 0.0018 * S * d Lv
As > As mín OK !!
Mu = 261208.75 kg - cm
Aøb S = 110.00 cm
# Varilla ( n ) = As d = 50.91 cm
Aøb a = 0.6000 cm (Valor Asumido)
As = 1.37 cm²
Espaciam = S - 2*r.e - Øb a = 0.293 cm
n -1
As = 0.63 cm²

USAR As mín = 10.08 cm²

As > As mín ASUMIR As mín !!


Aøb ( 5/8" ) = 1.98 cm²
Øb ( 5/8" ) = 1.58 cm
r.e = 7.50 cm

# Varilla ( n ) = 5.09 Varillas


# Varilla ( n ) = 5 Varillas

Espaciam. = 23.36 cm

USAR 5 Ø 5/8" @ 20.00 cm


Dirección Menor:

As tranv = As * T As trv. = 12.15 cm²


S USAR As trv. = 12.15 cm²
As mín = 0.0018 * S * d As mín = 10.08 cm²
As > As mín OK !!
As trv > As mín OK !!
Aøb
# Varilla ( n ) = As Aøb ( 5/8" ) = 1.98 cm²
Aøb Øb ( 5/8" ) = 1.58 cm
r.e = 7.50 cm
Espaciam = S - 2*r.e - Øb
n -1 # Varilla ( n ) = 6.14 Varillas
# Varilla ( n ) = 6 Varillas

Espaciam. = 18.68 cm

USAR 6 Ø 5/8" @ 18.00 cm

a = 1.00
ld = Øb * fy * a * b * g * < l Lv1 b = 1.00
3.54 * f 'c^.5 * C + Kr g = 0.80
Øb l = 1.00
C = 8.50
Lv1 = Lv - r.e Kr = 0.00
Øb (1/2") = 1.27
r.e = 7.50 cm

ld = 12.43 cm Longitud de desarrollo en tracción

ld = 12.43 cm < Lv1 = 47.50 cm OK !!


DISEÑO DE ZAPATA AISLADA EXCENTRICA CON CARGA CENTRADA
Margen Izquierda

DATOS: MD,ML
Zapata PD, PL
f'c= 175.00 kg/cm²
Columna s/c = 250.00 kg/m²
f'c= 210.00 kg/cm²
b= 25.00 cm Acero Columna g t1 h t1 = 60.00 cm
t= 30.00 cm 4 Ø 1/2"
Acero Df = 1.80 m
fy= 4200.00 kg/cm² g t2 h t2 = 60.00 cm
Suelo
Df = 1.80 m
g t1 = hc = 60.00 cm
1860.00 kg/m³
g t2 = 1860.00 kg/m³ T
qa = 1.29 kg/cm²
Otros
S/C = 250.00 kg/m²
PD = 5.20 Tn Ps = 8.67 Tn

S
PL = 3.47 Tn Pu = 13.18 Tn

b
MD = 0.90 Tn - m Ms = 1.51 Tn - m
ML = 0.61 Tn - m Mu = 2.30 Tn - m t
tT

1.- DIMENSIONAMIENTO DE LA ZAPATA ( Az = S*T )


Cálculo del peralte de la zapata (hc )

ld = 0.08 * Øb * Fy Øb ( 1/2" ) = 1.27 cm


f 'c^.5 ld = 32.26 cm

Tomar ld = 32.26 cm Longitud de desarrollo en compresión

r.e = 7.50 cm
hc = ld + r.e + Øb hc = 41.03 cm
ht = Df - hc Tomar hc = 60.00 cm

ht = 120.00 cm

Cálculo de la presión neta del suelo ( qm )

qm = qa - g t1*h t1 - g t2*h t2 - gc*hc - s/c

qm = 0.90 kg/cm²

Cálculo del área de la zapata ( Az )

A'z = Ps A'z = 9633.33 cm²


qm T'= 100.65 cm
T ' = Az^.5 + ( t - b ) S'= 95.65 cm
2 e= 17.42 cm
S ' = Az^.5 - ( t - b )
2 S= 130.49 cm
e = Ms Tomar S= 130.00 cm
Ps
S = S' + 2*e Lvb = 52.5 cm Lvt y Lvb deben
Lvb =Lvt = S - b Dimens. Lvt = 52.5 cm ser iguales (Lvb=Lvt)
2 Reales T= 135.00 cm
T = 2*m + t Tomar T= 135.00 cm

USAR S x T = 130 x 135 cm²


Verificación de las presiones ( q 1,2 )

e<T/6
q 1, 2 = Ps * 1 ± 6*e = qm OK !
S*T T

T/6= 22.5 cm > e = 17.42 cm

q1= 0.88 kg/cm² = qm = 0.90 kg/cm² OK !!


q2= 0.11 kg/cm² = qm = 0.90 kg/cm² OK !!

2.- DETERMINACIÓN DE LA REACCIÓN AMPLIFICADA ( qmu )

e = Mu e= 17.43 cm
Pu T/6= 22.50 cm > e = 17.43 cm
T/6
q 1u = 1.33 kg/cm² qmu se toma el mayor valor
e<T/6 q 2u = 0.02 kg/cm²
q 1u, 2u = Pu * 1 ± 6*e
S*T T Tomar qmu = 1.33 kg/cm²

3.- VERIFICACION POR CORTE ( Ø = 0.85 )


Por Flexión: d

Lv = ( T - t ) / 2 Lv = 52.50 cm
Vu = qmu * S * ( Lv - d ) r.e = 7.50 cm
Vc = 0.53 * f 'c^.5 * S * d Øb ( 1/2") = 1.59 cm
Vu = Øvc OK ! d= 50.91 cm qmu
Vu = 274.91 kg
r.e = 7.5 c.m Lv
Øb Vc = 46402.5 kg
d = hc - r.e - Øb Øvc = 39442.13 kg = Vu = 274.91 kg OK !!

Por Punzonamiento:

Vu = Pu - qmu * m * n

Vc = 0.27 * 2 + 4 * f 'c^.5 * bo * d = 1.10 * f 'c^.5 * bo * d d/2


n = b+d

b c
b

d/2
t
b c = lado mayor columna ( t )
lado menor columna ( b ) m = t+d

m=t+d
n=t+b T
bo = 2*m + 2*n
Vu = Øvc OK !
Ps= PD+PL= Kg

qm = kg/m²

0.00 * n = Kg
m

m= 80.91 cm
n= 75.91 cm
Vu = 5010.30 kg

b c= 1.2
bo = 313.64 cm
Vc = 1.04 * f 'c^.5 * bo * d = 304169.78 kg
Øvc = 258544.31 kg = Vu = 5010.30 kg OK !!

4.- CALCULO DEL REFUERZO LONGITUDINAL ( Ø = 0.90 )


Dirección Mayor:

Lv = ( T - t ) / 2 Lv = 52.50 cm
Mu = qmu * S * Lv² Mu = 238277.81 kg - cm
2
As = Mu / ( Ø * fy * ( d - a/2 ))
a = As * fy / ( 0.85 * f 'c * S )
qmu

As mín = 0.0018 * S * d Lv
As > As mín OK !!
Mu = 238277.81 kg - cm
Aøb S = 135.00 cm
# Varilla ( n ) = As d = 50.91 cm
Aøb a = 0.2693 cm (Valor Asumido)
As = 1.24 cm²
Espaciam = S - 2*r.e - Øb a = 0.2593 cm
n -1
As = 7.36 cm²

USAR As mín = 12.37 cm²

As > As mín ASUMIR As mín !!


Aøb ( 1/2" ) = 1.27 cm²
Øb ( 1/2" ) = 1.27 cm
r.e = 7.50 cm

# Varilla ( n ) = 9.74 Varillas


# Varilla ( n ) = 10 Varillas

Espaciam. = 13.19 cm

USAR 10 Ø 1/2" @ 13.19 cm


Dirección Menor:

As tranv = As * T As trv. = 13.19 cm²


S USAR As trv. = 13.19 cm²
As mín = 0.0018 * S * d As mín = 11.91 cm²
As > As mín OK !!
As trv > As mín OK !!
Aøb
# Varilla ( n ) = As Aøb ( 1/2" ) = 1.27 cm²
Aøb Øb ( 1/2" ) = 1.27 cm
r.e = 7.50 cm
Espaciam = S - 2*r.e - Øb
n -1 # Varilla ( n ) = 10.39 Varillas
# Varilla ( n ) = 10 Varillas

Espaciam. = 12.64 cm

USAR 10 Ø 1/2" @ 12.64 cm

a = 1.00
ld = Øb * fy * a * * b* * *g *< l Lv1 b = 1.00
3.54 * f 'c^.5 * C + Kr g = 0.80
Øb l = 1.00
C = 8.50
Lv1 = Lv - r.e Kr = 0.00
Øb (1/2") = 1.27
r.e = 7.50 cm

ld = 13.61 cm Longitud de desarrollo en tracción

ld = 13.61 cm < Lv1 = 45.00 cm OK !!


MEMORIA DE CALCULO DE INSTALACIONES ELECTRICAS

Area Techada Primer Piso 220 m²


Corredores : 103 m²
Total Area techada ( Sin Corredores ): 220 m²
Corredores : 103.00 m²

a)CALCULO DE LA CARGA INSTALADA

C I 1: ALUMBRADO = Area Techada (m²) x Carga Unitaria ( W/m²)


Local 25 Watt/m2

CI1 = 174.60 m2 x 25 Watt/m2= 5500 Watts

C I 2: Tomacorrientes = Potencia de computadorax N° de Computadoras


Potencia Computadora 80 Watts/Comp
N° de Computadoras : 0 Comp.

CI2 = 0 Watts

C I 3: ALUMBRADO = Area Corredor (m²) x Carga Unitaria ( W/m²)


Carga Corredores : 5 Watt/m2

CI3 = 103 m2 x 5 Watt/m2= 515 Watts

CARGA INSTALADA TOTAL CI 1 + C I 2 + C I 3 = 6015 Watts

b) CALCULO DE LA MAXIMA DEMANDA ( MD )

MD 1 = Carga Instalada 1 * Factor de Demanda


Factor Demanda Escuelas. 15 000 W o menos 100.00%
Sobre 15 000 W 50.00%

MD1= 5500 W x 1.00 = 5500 Watts

MD2= 0W x 1.00 = 0 Watts

MD3= 515 W x 1.00 = 515 Watts

MAXIMA DEMANDA TOTAL(MDT) = MD1+MD2+MD3 = 6015 Watts


c) INTENSIDAD ( I )

M.D.Total en Watts
I =
K x V x Cos¯

Donde:
I : Corriente a transmitir por el conductor alimentador en Amperios
M.D. Total : Máxima Demanda total hallada en Watts
V : Tensión de Servicio en Voltios ( Para Chaglla V = 220 V )
K : Factor que depende si el suministro es monofásico o trifásico así:
Para Monofásico : K= 1
Para Trifásico : K= 3
Cos φ : Factor de potencia estimado ( Cos φ = 0.90 )

M.D. Total : 6015 Watts


V : 220 Voltios
K : 1 ( Monofásico)
Cos φ : 0.9

I= 30.38 Amperios

Porcentaje de Aumento= 25.00%


I diseño = 37.98 Amperios

De la Tabla de "INTENSIDADES DE CORRIENTE PERMISIBLE EN AMPERIOS DE LOS CONDUCTORES DE COBRE AISLADOS"


Usar un Conductor de: 25 mm² TW admite una intensidad de 80 Amp. y su Interruptor de protección será de 80 Amp.

d) CAIDA DE TENSION ( ∆V)

KxIx δxL
∆V=
S

V= Caída de Tensión en Voltios


K= Constante que depende del Sistema así :
K= 2 ( Para circuitos Monofásicos )
K= 3 ( Para circuitos Trifásicos )
I = Intensidad o corriente del conductor alimentador- en amperios
δ = Resistencia en el conductor en Ohm - mm²/m. Para el cobre = 0.0175 Ohm-mm2/m
S = Sección del conductor alimentador hallada anteriormente. 25 mm²
STG-01

0.1
MEDIDOR
0.5

1.8

1.0

0.1 15.0

Lt= 18.5 m

∆V= 0.98 < 5.5 Voltios Okey!!

f) Calculo de la seccion del conductor alimentador de los STD-01,STD-02,STD-03 Y STD-04

Area Techada Laboratorio 63.97 m²


Total Area techada ( Sin Corredores ): 63.97 m²

a)CALCULO DE LA CARGA INSTALADA

C I 1: ALUMBRADO = Area Techada (m²) x Carga Unitaria ( W/m²)


Carga Escuelas : 25 Watt/m2

CI1 = 63.97 m2 x 25 Watt/m2= 1599.25 Watts

C I 2: Tomacorrientes = Potencia de computadorax N° de Computadoras


Potencia Computadora 80 Watts/Comp
N° de Computadoras : 16 Comp.

CI2 = 80 Watts/Comp *16 Comp = 1280 Watts


CARGA INSTALADA TOTAL CI 1 + C I 2 = 2879.25 Watts

b) CALCULO DE LA MAXIMA DEMANDA ( MD )

MD 1 = Carga Instalada 1 * Factor de Demanda


Factor Demanda Escuelas. 15 000 W o menos 100.00%
Sobre 15 000 W 50.00%

MD1= 1599.25 W x 1.00 = 1599.25 Watts

MD2= 1280 W x 1.00 = 1280 Watts

MAXIMA DEMANDA TOTAL(MDT) = MD1+MD2 = 2879.25 Watts

c) INTENSIDAD ( I )

M.D.Total en Watts
I =
K x V x Cos¯

Donde:
I : Corriente a transmitir por el conductor alimentador en Amperios
M.D. Total : Máxima Demanda total hallada en Watts
V : Tensión de Servicio en Voltios ( Para Chaglla V = 220 V )
K : Factor que depende si el suministro es monofásico o trifásico así:
Para Monofásico : K= 1
Para Trifásico : K= 3
Cos φ : Factor de potencia estimado ( Cos φ = 0.90 )

M.D. Total : 2879.25 Watts


V : 220 Voltios
K : 1 ( Monofásico)
Cos φ : 0.9

I= 14.54 Amperios

Porcentaje de Aumento= 25.00%


I diseño = 18.18 Amperios
De la Tabla de "INTENSIDADES DE CORRIENTE PERMISIBLE EN AMPERIOS DE LOS CONDUCTORES DE COBRE AISLADOS"
Usar un Conductor de: 4 mm² TW admite una intensidad de 25 Amp. y su Interruptor de protección será de 25 Amp.

d) CAIDA DE TENSION ( ∆V)

KxIx δxL
∆V=
S

V= Caída de Tensión en Voltios


K= Constante que depende del Sistema así :
K= 2 ( Para circuitos Monofásicos )
K= 3 ( Para circuitos Trifásicos )
I = Intensidad o corriente del conductor alimentador- en amperios
δ = Resistencia en el conductor en Ohm - mm²/m. Para el cobre = 0.0175 Ohm-mm2/m
S = Sección del conductor alimentador hallada anteriormente. 4 mm²

STG-01

0.1
MEDIDOR
0.5

1.8

1.8

0.1 40.0

Lt= 44.3 m

∆V= 7.05 < 5.5 Voltios Aumentar Sección del Conductor