_ H-LEVEL
LIQUID LEVEL SYSTEM
settlement
gauges
H-LEVEL
PK
H-LEV_EN_04_6/2019
H-LEVEL
LIQUID LEVEL SYSTEM
The H-Level is an automatic system for long-term monitoring of
differential settlements in buildings, tunnels, and other civil structures.
APPLICATIONs FEATURES
• Buildings • Available with both
digital or analogue output
• Tunnels
• High accuracy and performance
• Compensation grouting
projects • Automatic compensation for
barometric pressure
• Excavations
• No need to install each gauge at
• Historical structures
the same elevation
• Bridges
• Fieldstat software for enhanced
data analysis
H-LEV_EN_04_6/2019
DIGITAL H-LEVEL 110 mm
SPECIFICATIONS
95 mm
PRODUCT CODES 0HLEV050D00, 0HLEV100D00
sensor
Description Digital H-Level system is composed by the housing
yellow pressure gauge and the digitalizing
box (D-BOX), connected with 500 mm
cable. System protection: IP65
140 mm
95 mm
Range 500 mm H2O (20”) or 1000 mm H2O (39”)
(2000 mm on request)
Gauge sensitivity
500 mm H2O 0.03 mm (0.0012") H2O
97 mm
1000 mm H2O 0.06 mm (0.0024") H2O
43 mm
Hydraulic tube OD / ID 12 mm / 10 mm (0.5 / 0.4") polyamide
Max. distance to datalogger (3) 1000 m (for more information see FAQ#77)
66 mm
(1) D-BOX is configurated as default output “mm H2O”. At order time, Customer can specify other units, such as: bar, mbar, atm, psi, Pa, kPa,
MPa, mmH2O (d, mH2O, inH2O, ftH2O, mmHg, cmHg, inHg, Kg/cm2, Kg/m2, lb/in2, lb/ft2, N/cm2, N/m2, t/m2, t(UK)/ft2, t(USA)/ft2. Sisgeo Modbus 105 mm
protocol manual is available for download at this page. (2) MPE is the Maximum Permitted Error on the measuring range (FSR). In 120 mm
the Calibration Report, the accuracies of the gauge are calculated using both linear regression (≤ Lin. MPE) and polynomial
correction (≤ Pol. MPE) (3) Refer to FAQ section of Sisgeo website: www.sisgeo.com/faq
PHYSICAL FEATURES
SENSOR HOUSING
6 mm
D-BOX
H-LEV_EN_04_6/2019
ANALOGUE H-LEVEL 110 mm
SPECIFICATIONS 95 mm
140 mm
Output signal 4-20 mA current loop, Ohm (thermistor)
95 mm
Gauge sensitivity
range 500 mm H2O 0.03 mm (0.0012") H2O
range 1000 mm H2O 0.06 mm (0.0024") H2O
3 mm
Temperature sensor thermistor embedded (accuracy ±0.5°C)
170 mm
barometric
Max. distance to datalogger (2) 1000 m (for more information see FAQ#77)
reference
(1) MPE is the Maximum Permitted Error on the measuring range (FSR). In the Calibration Report, the accuracies of the gauge
are calculated using both linear regression (≤ Lin. MPE) and polynomial correction (≤ Pol. MPE) (2) Refer to FAQ section of Sisgeo
website: www.sisgeo.com/faq
200 mm
REFERENCE TANK
Fluid in the reference tank establishes the reference level for all the gauges in the system.
Barometric pressure is transmitted to the system through a secondary enclosure that is
reference
fitted with a membrane filter and dessiccant to eliminate humidity.
tank
302 mm
H-LEV_EN_04_6/2019
OPERATING The H-Level is an automatic system for long-term monitoring of differential settlements in buildings,
tunnels, and other civil structures. The system consists of a series of H-Level gauges that are connected
PRINCIPLE hydraulically via fluid-filled tubing to a reference tank that is located at a stable location. A separate air-
filled tube connects each gauge to an air intake located near the reference tank.
Each H-Level gauge includes a high resolution pressure sensor that monitors the head of liquid resulting
from the difference in elevation of the gauge and the reference tank. The gauges report a higher head
of fluid (higher pressure) if settlement occurs and a lower head of fluid (lower pressure) if heave occurs.
The air-filled tube connected to each gauge eliminate error due to changes in barometric pressure. In
addition, an H-Level gauge located near the reservoir is used to control for thermal effects. If freezing
temperatures are expected, a de-aired, anti-freeze liquid can be used in the tubing and reservoir.
The H-level monitoring system can be connected to the OMNIAlog data acquisition system where both
pressure (level) and temperature are stored for processing.
reference
tank
Measured pressure
reference
gauge
bleed first
valve H-Level gauge
last hydraulic
H-Level gauge tube
lower sensor
position
RS-485 RS-485
termination resistance digital signal cable
H-LEV_EN_04_6/2019
EXAMPLE OF TUNNEL APPLICATION - DIGITAL SYSTEM
junction box
0WE606IPDZH
TUNNEL IN cable
CONSTRUCTION
H-LEV_EN_04_6/2019
EXAMPLE OF BUILDING APPLICATION - ANALOGUE SYSTEM
EXCAVATION
H-LEV_EN_04_6/2019
ACCESSORIES
AND SPARE PARTS
HYDRAULIC TUBING WATER-GLICERINE MIX HYDRAULIC Circuit INSULATION
0TUNY101200 1000LIGL000 1000COPE300
Polyamide tube for hydraulic Recommended fluid for H-Level circuit. Insulated protective tube for hydraulic
connection of the H-Level gauges. It is a mixture of 50% glycerine and 50% tubing. Recommended when tubing
12 mm OD, 10 mm ID. water, chemically inert, allowing operation is exposed to large temperature
to -20 °C. Available in 12 L and 25 L tanks. excursions. 3m length.
SATURATION DEVICE
AIR COMPENSATION TUBE TUBES SPLICING KIT
0D422SAT200
0TUNY060800 0HLEVKIT0JN
Saturation device for H-Level hydraulic Air polyamide tube tube for transmitting Hydraulic splicing kit for up to 5 liquid
circuit, capacity 20 liters, max pressure barometric pressure throughout the and air compensation tubes.
5 bars, power supply 230V only. system. OD 8 mm, ID 6 mm.
Highly recommended.
SIGNAL CABLE for H-Level Gauges DIGITAL JUNCTION BOX DIGITAL cable
0WE104SG0ZH 0EPD023IPID 0WE606IPDZH
4 22-AWG wires in 2-twisted pairs, Junction box for chains of digital H-Levels, LSZH cable for connecting digital
with aluminium/polyester shield and composed by IP67 plastic box, wiring instruments chain from junction box up
LSZH jacket. 4.7mm diameter. electronic board and 3 cable glands.
H-LEVEL SPARE CONNECTOR SPARE H-LEVEL DIGITAL SENSOR RESISTANCE ENDING DEVICE
0ECON05fv00 0HLEV000V00 0ETERMRESIT
IP67 spare connector to be installed Spare digital H-Level sensor housing, Termination resistance with connector,
on signal cable for H-Level jointing. including gauge and hydraulic needed to close every digital H-Level
connectors. chain. For more detail see FAQ#076.
READABLE BY
All the information in this document is the property of Sisgeo S.r.l. and should not be used without permission from Sisgeo S.r.l.
We reserve the right to change our products without prior notice. The datasheet is issued in English and other languages.
In order to avoid discrepancies and disagreement on the interpretation of the meanings, Sisgeo Srl declares that English Language prevails.