m(1) Q(2) T(3) T/(T-1) (4) x (5) =log log de t/(t-1) (Q)(X) (6)

1 3800 31 1.0333 -1.8469 -7018.22


2 2280 15.5 1.069 -1.5379 -3506.41
3 1660 10.3333 1.1071 -1.3547 -2248.8
4 1410 7.75 1.1481 -1.222 -1723.02
5 1230 6.2 1.1923 -1.117 -1373.91
6 1150 5.1667 1.24 -1.0296 -1184.04
7 1120 4.4286 1.2917 -0.954 -1068.48
8 1030 3.875 1.3478 -0.8873 -913.92
9 953 3.4444 1.4091 -0.827 -788.13
10 934 3.1 1.4762 -0.7717 -720.77
11 921 2.8182 1.55 -0.7205 -663.58
12 917 2.5833 1.6316 -0.6724 -616.59
13 876 2.3846 1.7222 -0.6269 -549.16
14 850 2.2143 1.8235 -0.5835 -495.98
15 824 2.0667 1.9375 -0.5418 -446.44
16 818 1.9375 2.0667 -0.5013 -410.06
17 779 1.8235 2.2143 -0.4619 -359.82
18 740 1.7222 2.3847 -0.4232 -313.17
19 683 1.6316 2.5833 -0.3849 -262.89
20 658 1.55 2.8182 -0.3468 -228.19
21 618 1.4762 3.1 -0.3086 -190.71
22 610 1.4091 3.4444 -0.2699 -164.64
23 581 1.3478 3.8752 -0.2304 -133.86
24 563 1.2917 4.4282 -0.1896 -106.74
25 557 1.24 5.1667 -0.1468 -81.77
26 522 1.1923 6.2002 -0.1011 -52.77
27 520 1.1481 7.7522 -0.0509 -26.47
28 418 1.1071 10.3371 0.0062 2.59
29 367 1.069 15.4928 0.0756 27.75
30 360 1.0333 31.03 0.1737 62.53
SUMATORIA 28749 -17.8531 -25555.67

3.calculo de Qm y Xm
Qm= 958.3 a= 240.437
Xm -0.5951

4.calculo de los parametro de a y b 5 calculo del caudal maximo


b= -1206.2897 Qmax
PARA T=50 AÑOS 2721.541132
PARA T=100 AÑOS 3087.323162

6. CALCULO DE LAS DESVIACIONES ESTANDAR Y COVARIANZA


Sxx= 210.0738
Sqq= 391346949
Sxq= -253411.33

7.calculamos el intervalo de confianza


▲Q 342.64646 PARA T 50 AÑOS x= -2.05680612
▲Q 377.04913 PARA T 100 AÑOS x= -2.36003511
8.CALCULO DEL CAUDAL DE DISEÑO
PARA T = 50 AÑOS Qd= 3064.18759099534 m3/s
PARA T = 100 AÑOS Qd= 3464.37229145612 m3/s
Q² (7) X² (8)
14440000 3.411
5198400 2.3651
2755600 1.8352
1988100 1.4933
1512900 1.2477
1322500 1.0601
1254400 0.9101
1060900 0.7873
908209 0.6839
872356 0.5955
848241 0.5191
840889 0.4521
767376 0.393
722500 0.3405
678976 0.2935
669124 0.2513
606841 0.2134
547600 0.1791
466489 0.1481
432964 0.1203
381924 0.0952
372100 0.0728
337561 0.0531
316969 0.0359
310249 0.0216
272484 0.0102
270400 0.0026
174724 0
134689 0.0057
129600 0.0302
40595065 17.6269

lculo del caudal maximo

50 años en estos años se debe cambiar