Está en la página 1de 3
AN RTI Pe ‘Shenzhen Academy of Metrology & Quality Inspection an Pret eet bem CNASE: National Hi-tech Metrology Station has ost is E Tk CALIBRATION REPORT + 185304298 i a ce 1K, Page 1 of 3 Pages BBR RUT PMP IRA Al Name of Customer eP Hh PRvITT DR TDR UE A P4306 (CFU IPT ORR Asies of Customer UEBAZR: APRIL Name of Instrument Pe Use of nsrument BUS /B —:— PMG530D “TpetSpeccaton i Sera ne wm S =: C12-PM6530-001 eset ne fA =: PEAKMETER Menufscurer BOERGE =: I RMFZIIGIO6-2015 LEASE alate cordance to HEA iF BUSTS) Authorized by an. AS. Ssorature CERHES ALE) Samp BEEAR =: 2018 # 07 A 12 A ae Rectal ce won. ABE EWA: 2019 ba o7 Al a Crested by ‘Siggsed Real ate Nonin ) BOER : ADAG Caltrated by —_ PEMRESS. oem ROOT, Register No (2012)8RRFO02S eit: REAM ET RA ‘AddMet ology and Qulty Inspection Bling Cenrl Secton of Lngehu Road, 26941698 O086-755-26911518 Nanznan Date sherahen 26941615 O086-755-2694 1517 “Tel G036-755 26941696 0085-755.26081545 FB: wre. sag. con. en Fox:0086-755 26941615 0086-755-26941547 PMP. kfastang, com co Post Code'518055 itp:/wuusma.comen Exmaitkce@sma.com.cn Uli Baw Shenzhen Academy of Metrology & Quality Inspection Rea eo ional Hi-tech Metrology Station BOERS ‘CALIBRATION REPORT RAMS. 185304298 H2R KID aot S-HEPEEEEEEEEHE EEE EEE EEE EE 7 paged Pass CLNELH ARES Main Standard Devices Used FORT EAETA | maeBa 206 ror ial a er xdpne tere es Range pata esac) Or crc ove Dte BURA ESAS Main Standards of Measurement Used FREAD | eo ween perc os Ra ens = | axons nupmercware | teawngange | yrcerannyacarag, | cqupment | cetiiatens |e De eH (-50~1000) C ‘£0.5CM40. Strdg ‘$B12072 RGrr2017-0890 | 2018-08-24 Memo opended Drectons SHAR: 2018 # 07 A 06 A appli te Bet: ABIL (WO 18 Thermoneter Leb.) Opraon Lcoten aH RE 24 C HEIE 56% peat Enonnert FAME RO: SB ILLLUELEA ARAKI Use refering to the results of calibration) ‘Statement ef Compliance and Liation IPT SRS AMAA Shenzhen Academy of Metrology & Quality Inspection Bim wisi as National Hi-tech Metrology Station BOERS (CALIBRATION REPORT RBS. 185304298 3H 3H Repert 2 Page 3of3 Pages BER Results of Calibration —. HM: ABR Appearance Inspection:Pass =. BREE RUN © (Emissivity): 1.00 =. WARE (Intrinsic Error Calibration): 7 7 BAR EE : ire BLE | Intrinsic | pianeter of the hesiteril Tenperature [Indication Value Type of the ce) ce) Error | radiation source | saiation source ced (oa) 50 50.7 40.7 RAL 150 146.7 -3.3 65 blackbody radiation source |" 400 400.2 40.2 a» tap 2 HE (otes) : J LRAT RAMEE: Expanded uncertainty of Error: SOC: U0. 8C, A-2s 150'C: LH0.8°C, A-2; 400°C: 22°C, fede 2 RBA AE EAT AR: JJPLO59. 1-2012 (RAMEE TE SAD. The analysis of uncertainty is according to JJPIO59. 1-2012 Evaluation and Expression of Uncertainty in Measurement. 3. ROMER (Calibration distance): 300mm. 4. ERA EE HOIEWHEH (Spectral range of radiation thermometer) : (8~14) um.

También podría gustarte