Documentos de Académico
Documentos de Profesional
Documentos de Cultura
LRT 001 Adaptadores Expro
LRT 001 Adaptadores Expro
LRT-ADP_001
CONTACT KIT´S
# ADP PART NUMBER CONTACT KIT DESCRIPCION DE C.KIT COMENTARIOS C.KIT
1 3903-000-502 PUNTA GO 1-11/16IN *PARA ALTO VOLTAGE
2 0256-100-032 QUICK CHANGE *2-3/4 Y 3-1/8 ES IGUAL
3 3885-000-022 EMPATE B.ELEC 2-3/4 A B.ELEC 2-3/4
4 3890-000-112 2-3/4 (B.E) A GO QUICK CHANGE *GO QUICK CHANGE
5 3885-000-060 3885-000-062 2-3/4 (B.E) A CCL (lower conection) *ADP PARA BOTTOM CCL (1 segger)
6 3885-000-150 3885-000-152 2-3/4 (B.E) A ACME 1-5/8 (PIN) *ACME PIN (Q-CH PIN)
7 3885-000-070 3890-000-222 2-3/4 (B.E) A CCL (upper conection) *ADP PARA TOP CCL (1 segger)
8 3885-000-010 2-3/4 (B.E) A 1-3/16 GO BOX (1 segger)
9 3885-000-050 0318-000-022 2-3/4 (B.E) A ACME BOX
10 3933-000-030 PIN / PIN OD 1-11/16_ROSCA 1-3/16 *MACHO - MACHO
ORINGS
#ADP O-RING SIZE CANTIDAD DESCRIPCION COMENTARIOS
1 211 2 PUNTA GO 1-11/16IN *2 O-RINGS EN LA ROSCA
2 222 4 QUICK CHANGE *4 O-RING EN EL CUERPO
2 210 1 QUICK CHANGE *1 ORING BOTTOM
2 2-113 1 QUICK CHANGE *1 ORING DENTRO DEL BOTTOM
3 227 4 EMPATE B.ELEC 2-3/4 A B.ELEC 2-3/4 *4 ORINGS EN EL CUERPO
4 227 2 2-3/4 (B.E) A GO QUICK CHANGE *2 ORING EN 2-3/4 (B.E)
4 227 2 2-3/4 (B.E) A GO QUICK CHANGE *2 ORING EN GO Q-CHANGE
5 227 2 2-3/4 (B.E) A CCL (lower conection) *2 ORING EN 2-3/4 (B.E)
5 227 2 2-3/4 (B.E) A CCL (lower conection) *2 ORING EN CCL (lower conect)
6 227 2 2-3/4 (B.E) A ACME 1-5/8 (PIN) *2 ORING EN 2-3/4 (B.E)
6 222 2 2-3/4 (B.E) A ACME 1-5/8 (PIN) *2 ORING EN ACME (Q-CH)
7 227 2 2-3/4 (B.E) A CCL (upper conection) *2 ORING EN 2-3/4 (B.E)
7 227 2 2-3/4 (B.E) A CCL (upper conection)
8 227 2 2-3/4 (B.E) A 1-3/16 GO BOX *2 ORING EN 2-3/4 (B.E)
9 227 2 2-3/4 (B.E) A ACME BOX *2 ORING EN 2-3/4 (B.E)
10 211 4 PIN / PIN OD 1-11/16_ROSCA 1-3/16 *4 ORINGS EN EL CUERPO
TECMADE / OTROS
No PARTE DESCRIPCION
3916-328-040 CONO ROPESOCKET 9/32
3916-0CW-218 ARANDELA (WASHER) 1/8
T012715 FEEDTHROUGH
T013964 NUEVO NUT-FEEDTHROUGH
9400-EBRN-F VIEJO NUT-FEEDTHROUGH
T005630 BANANA
MANUAL DE ADAPTADORES 12/19/2017
LRT-ADP_001
Este Contact Kit es para ALTA Corriente.- Max Voltage 600 V y 6,000 mA (Contact Kit Normal
es para 600 V y 2,000 mA).
Max Tension: 42K Lbs [18,7 Tons] ROSCA: 1-3/16in GO Pin
MANUAL DE ADAPTADORES 12/19/2017
LRT-ADP_001
LRT-ADP_001
LRT-ADP_001
LRT-ADP_001
LRT-ADP_001
LRT-ADP_001
LRT-ADP_001
LRT-ADP_001
LRT-ADP_001
LRT-ADP_001
LRT-ADP_001
REPUESTOS
CONTACT KIT CANTIDAD DESCRIPCION
DISCO Y BLEED OFF +
WST-3625-135 1
ORING 213
WST-3625-140 1 LLAVE DESFOGUE