NZ200 Series User's Manual List of Function Parameters List of Function Parameters NZ200 Series User's Manual List of Function Parameters If PP.OO is set to a non-zero number, parameter protection is enabled. You must enter the correct user password to enter the menu. To cancel the password protection function, enter with password and set PP.00 to 0. Parameters menu the user customizes are not protected by password.Group P is the basic function parameters , Group D is to monitor the function parameters. The symbols in the function code table are described as follows: “w": The parameter can be modified when the AC drive is in either stop or running state. "x": The parameter cannot be modified when the AC drive is in the running state. “e": The parameter is the actually measured value and cannot be modified. ": The parameter is factory parameter and can be set only by the manufacturer. Standard Function Parameters Function] Parameter Code Name P0.00 |G/P type display] 2: P type (variable torque load e.g. 0:Voltage/Frequency (V/F) Control mode {control Pom selection 1:Sensorless flux vector 0:Operation panel control po.2 |_ Command | Terminal control 0 * source selection 2:Communication contral NZ200 Series User's Manual ee Faonetet Setting Range Unit's digit (Frequency source) 0:Main frequency source X 1:X and Y operation(operation relationship determined by 'ten's digit) 2:Switchover between X and Y| Frequency 3:Switchover between X and superposition "X and Y operation" ‘selection 4:Switchover between Y and "X and Y operation" 0:Digital setting (PO1.0 preset frequency, can modify the UP/DOWN, power lost don't mem 1:Digital setting (P0.10 preset frequency, can modify the UP/ Main frequency | DOWN, power lost memory) P0.04 source X 2:FIV/keyboard potentiometer selection 9:Communications given ‘Auxiliary frequency |The same as P0.04 (Main P0.05 source Y frequency source X selection) selection Auxiliary 0: Relative to the maximum frequency P0.06 source frequency . 1: Relative to the main superpomian'Y frequency source X range selection Auxiliary frequency PO0.07 source 0%~150% 100% * superposition Y range List of Function Parameters Function] Parameter Code Name Acceleration POL08: time 1 Deceleration FO.09) time 1 PO.10 Frequency |0.00Hz~maximum . preset frequency(P0.12) PO.11 Rotation 0: Same direction . direction 41: Reverse direction Maximum Po.12 equent Upper limit P0.13 frequency source —_|4: PULSE settings 5: communication settings —_ Frequency lower limit PO.14 foe Po.16-Meximum frequency PO1S Upper limit |0.00Hz~Maximum frequency PO.16 frequency offset|P0.12 Frequency lower|0.00Hz~Upper limit frequency limit P0.14 Carrier PO.17 frequen 1kHz~16.0kHz Carrier frequency : PO.18 adjustment with |1: Yes temperature Acceleration/ |0: 1s P0.19 | Deceleration |1:0.1s time unit 2:0.01s Frequency offset of P0.21 auxiliary 0.00Hz~Maximum frequency ” frequency |P0.12 source for X and) Y operation P0.22 Frequency |1:0.1Hz reference |2:0.01Hz NZ200 Series User's Manual Function) Parameter code Rare Setting Range Default Retentive of P0.23 digital setting |0:Not retentive frequency upon | 1:Retentive power Acceleration/ Deceleration time base frequency 0:Maximum frequency (P0.12 )| Base frequency for UP/DOWN |0: Running frequency modification |1: Set frequency during running Unit's digit:Binding operation Panel command to frequency Binding . 5:Pulse setting (S3) command | 6: Multi-reference PO.26 source to 000 frequency Pera PLC Source '9:Communication setting Ten's digit:Binding terminal ‘command to frequency source(0~9,same as unit's digit) Hundred's digit:Binding communication command to frequency source(0~9,same as unit's digit) Communication PO.27 expansion |0:Modbus communication card oO card type Group P1:Start/Stop Control 0: direct start 1: Rotational speed tracking P1.00 Start mode [restart 0 2: Pre-excited start (asynchronous motor) List of Function Parameters Function Parameter code Rare Setting Range Defai Rotational | 0: From frequency at stop P1.01 1: From zero speed tracking mode |2: From maximum frequency Rotational P1.02 | speed tracking | 1~100 speed Startup ~ P1.03 frequency 9.00Hz~10.00Hz Startup P1.04 frequency |0.0s~100.0s holding time Startup DC braking current/ P1.08 | ""'Pro-exclted current Startup DC P1.06 | braking time/ |0.0s~100.0s Pre-excited time: 0: Linear acceleration! deceleration Acceleration’ |, . " P1.07 | Deceleration 7 Scurvs acceleration! Gicds, deceleration A 2: S-curve acceleration/ deceleration B Time proportion bs r P1.08 of S-curve start 0.0%~ (100.0%-P1.09 ) Time proportion _ P1.09 Gf Sturveend 0.0%~ (100.0%-P1.08 ) 0: Decelerate to stop P1.10 Stop mode 1: Coast to stop Initial frequency P1.11 of stopDC = |0.00Hz~maximum frequency braking Waiting time of PL stop DC braking ‘Stop DC braking P1.13 current Stop DC braking P1.14 time P1.15 | Brake use ratio NZ200 Series User's Manual Function] Parameter ib Code Name Seting Renve |Group P2: Motor Parameters 0: Common asynchronous P2.00 Motor type [motor ” selection 1: Variable frequency p2.01 | Rated motor power P22 | Rated motor P2.03 Rated motor current Rated motor i P2.04 frequency 0.01Hz~maximum frequency Rated motor P2.05 rotational speed Stator resistance P2.06 (esynchronous 0,0019~65.5350. motor) Rotor resistance} P2.07 | (asynchronous |0.0010~65.5350 motor) Leakage inductive P2.08 redctancs 0.01mH~655.35mH (asynchronous Mutual inductive reactance P2.09 (asynchronous 0.1mH~6553.5mH motor) No-load current P2.10 | (synchronous |0.01A~P2.03 motor) P2.11-P2.36 Reserved 9:No auto-tuning Auto-tuning 1 :Asynchronous motor static P2.37 selection auto-tuning 2:Asynchronous motor complete auto-tuning 'Group P3: Vector Control Parameters Speed loop P3.00 | proportional |1~100 30 * gain 1 List of Function Parameters Setting Range Default Property| Speed loop integral time 1 0.01s~10.00s 0.50s Switchover frequency 1 0.00~P3.05 5.00Hz pa Speed loop proportional gain 2 1~100 20 Speed loop integral time 2 Switchover frequency 2 (0.01s~10.00s P3.02~maximum output frequency 1.00s 10.00Hz Vector control slip gain Time constant of| speed loop filter 50%~200% 0.000s~0.100s 100% 0,000s MH ] |e Pe | oF Vector control over-excitation gain 0~200 64 Torque upper limit source in speed control mode 0:P3.10 4:FIV 2:FIC/AVI 3:Reserved '4:Pulse setting '5:Communication setting 6:MIN(FIV,FIC) 7:MAX(FIV,FIC) digital setting of torque upper limit in speed control mode 0.0%~200.0% 150.0% Excitation adjustment proportional gain Excitation adjustment integral gain 0~60000 (0~60000 2000 1300 Torque adjustment proportional gain 0~60000 2000 Torque adjustment 0~60000 integral gain 1300 NZ200 Series User's Manual Function Code Name Seting Renve s loop Unilts: digit: integral separation P3.17 into ry 0: Disabled ‘gral property|: Enabled P3.18 Reserved P3.19 Reserved P3.20 Reserved P3.21 Reserved P3.22 Reserved (Group P4: V/F Control Parameters O:Linear V/F 1:Multi-point V/F 2:Square V/F ViF curve = |4:1.4-power V/F P4.00) “setting —_|6:1.6-power VIF 8:1.8-power V/F 9:Reserved 10:V/F complete separation 11:V/F half separation 0.0%: (Automatic torque boost Model P4.01 | Torque boost |) dependent! te 0.1%~30.0% P Cut-off i P4.02 | frequency of rowan output 10.00Hz | * torque boost ey. Multi-point VIF 7 P4.03 frequency 4 (F1 0.00Hz~P4.05 0.00Hz * Multi-point VF - P4.04 | voltae 1 (v1) |0:0%7100.0% Multi-point VIF i 4.05 |,Mul-point VIF lpg o3-P4.07 | oor | | Multi-point V/F i P4.06 | oiase 2 0.0%~100.0% P4.07 Multi-point V/F |P4.05~rated motor frequency + ‘ frequency 3 (F3)|(P1.04) Multi-point V/F ' paos | Mul-point VIF To o5,100.0% VIF slip P4.09 | compensation |0.0%~200.0% 0.0% * gain VIF over- P4-10 | excitation gain 10 * List of Function Parameters Function Parameter Code Name Seting Renve VIF oscillation P4.11 suppression |0~100 gain O:digital setting(P4.14) 4:FIV Voltage source |4:PULSE setting(S3) P4.13 for VIF 5:Multi-reference separation |6:Simple PLC 100.0% corresponds to the rated motor voltage. Voltage digital P4.14 | setting for V/F |OV~rated motor voltage separation 7 0.0s~1000.0s pats | age Vee |itindicates the time for the * Separation voltage rising from 0 V to rated Epa motor voltage. 0.0s~1000.0s pa eee are [It indicates the time for the separation voltage to decline from rated motor voltage to 0 V. NZ200 Series User's Manual Function) Parameter code Rare Setting Range (Group P5: Input Terminals 0:No function 1:Forward RUN(FWD) 2:Reverse RUN(REV) FWD function [9 Three-line control P5.00 |4:Forward JOG(FJOG) selection 10:RUN pause 411:Normally open (NO) input of external fault 12:Multi-reference terminal 1 13:Multi-reference terminal 2 14:Multi-reference terminal 3 15:Multi-reference terminal 4 16:Terminal 1 for acceleration’ deceleration time selection 17:Terminal 2 for acceleration! deceleration time selection 18:Frequency source Switchover 19:UP and DOWN setting clear (terminal, operation Panel) 20:Command source ‘switchover terminal 21:Acceleration/Deceleration Prohibited REV function P5.01 selection P5.02 S1 function |22:PID pause . selection 23:PLC status reset 24:Swing pause 25:Counter input 26:Counter reset 29:Torque control prohibited 30:Pulse input (enabled only for S3) 31:Reserved 32:Immediate DC braking 33:Normally closed (NC) input of external fault 2 function P5.03 selection 10 List of Function Parameters Eee ae Setting Range Default 34:Frequency modification forbidden 35:Reverse PID action direction 36:Extemal STOP terminal 4 ic 37:Command source P5.04 el switchover terminal 2 0 * 38:PID integral pause 39:Switchover between main frequency source X and preset! frequency 40:Switchover between auxiliary frequency source Y and preset frequency |41:Motor selection terminal 4 42:Motor selection terminal 2 |43:PID parameter switchover ‘4 function * P6.05 selection it |47:Emergency stop 48:External STOP terminal 2 |49:Deceleration DC braking 50:Clear the current running P5.10 |__S filter time . B 0.010s P5.11 Terminal 1: Two-line mode 2 0 “"" |command mode}2: Three-line mode 1 3: Three-line mode 2 ps.12 | Terminal UP! lo co ttizis~65.535Hzis 4.00Hzis : DOWN rate : ‘ : Fl curve 1 P5.13 minimum input 0.00V~P5.15 0.00V Corresponding p54 | Seno! | 100.0%~+100.0% 0.0% minimum input p6.is|_ Flcuvet los 13-+10.00V to.00v | x maximum input 1 NZ200 Series User's Manual Function] Parameter ib code Rare Setting Range Default Corresponding setting of P5.16 Fl curve 1 -100.0%~+100.0% 100.0% maximum input Fl curve 1 filter PS.17 time 0.00s~10.00s . 10s OOV 0% Corresponding setting of P5.21 Fl curve 2 -100.0%~+100.0% 100.0% maximum input Fl curve 2 filter P5.22 time 0.00s~10.00s 10s BV 0% 10s 0% 0. Fl curve 2 P5.18 minimum input 0.00V~P5.20 9. Corresponding setting of P5.19 Fl curve 2 -100.0%~+100.0% 0. minimum input Fi curve 2 P5.20 maximum input P5.18~+10.00V 10.00V 0. 0. Fl curve3 P5.23 minimum input -10.00V~P5.25 Corresponding setting of P§.24 Fl curve 3 -100.0%~+100.0% 0. minimum input Fi curve 3 P5.25 maximum input P5.23~+10.00V 10.00V Corresponding setting of P5261 Er cune3 |7190-0%~+100.0% 100.0% maximum input Fl curve 3 filter P5.27 time 0.00s~10.00s 0 PULSE P5.28 milnlevur [ip 0.00kHz~P5.30 0.00kHz Corresponding P5.29 | setting of pulse |-100.0%~100.0% 0. minimum input PULSE PS5.30 maximum input P5.28~100.00kHz 50.00kHz Corresponding P5.31 | setting of pulse |-100.0%~100.0% 100.0% * maximum input 12 List of Function Parameters Function] Parameter ib code Rare Setting Range Default Property p5.az | PULSE Ter |o.o05~10.00s o.10s | Unit's digit:FIV curve selection 1:Curve 1(2 points, see P5.13~P5.16) 2:Curve 2(2 points, see P5.18~P§.21) Fl curve es Fa P5.33 selection : 321 * selection(1~5,same as FIV) Hundred's digit:FIA curve selection(1~5,same as FIV) Setting for | Ten's digit:Setting for FIC less P5.34 Flless than |than minimum input(0~1,same minimum input |as FIV) Hundred's digit:Setting for FIA less than minimum input(0~1,same as FIV) P5.35 | FWD delay time|0.0s~3600.0s P5.36 | REV delay time P5.37 |_S1 delay time O:High level valid 1:Low level valid "7 Unit's digit:FWD p5.a8 | Svalid mode |Ten's digitREV Hundred’s digit:S1 'Thousand’s digit:S2 i O:High level valid p59 | S valid mode 1:1 ow level valid Unit's digit:S4 |Group P6: Output Terminals M01 terminal a . P6.00 | output mode 1:Switch signal output(M01) 0 te 13 NZ200 Series User's Manual Function) Parameter Code Name Setting Range Default Property '0:No output 4:AC drive running 5:Zero-speed running(no output at stop) 6:Motor overload pre-warning 7:AC drive overload pre- warning 8:Set count value Reached 9:Designated count value reached 10:Length reached 11:PLC cycle complete 12:Accumulative running time reached 13:Frequency limited 14:Torque limited 15:Ready for RUN 16:FIV>FIC. 17:Frequency upper limit reached P6.01 | MO1 function | 18:Frequency lower limit reached (no output at stop) 19:Under voltage state output 20:Communication setting 21:Reserved 22:Reserved 23:Zero-speed running 2 (having output at stop) 24:Accumulative power-on ‘time reached 25:Frequency level detection 31:FIV input limit exceeded 32:Load becoming 0 33:Reverse running 34:Zero current state 36:Module temperature reached 36:Software current limit exceeded 14 List of Function Parameters Function Parameter code Rare Setting Range Default Property 37:Frequency lower limit reached (having output at Relay output |stop) P6.02 |function(RA-RC/|38-Alarm output RA-RB-RC) |39:Reserved |40:Current running time reached 0:Running frequency 1:Set frequency FOV function |2:Output current Pear selection P6.08 | Reserved — [42:Communication setting 13:Motor rotational speed 14:Output current(100.0% for 1000.0A) 15:Output voltage(100.0% for P6.09 Reserved FOV offset P6.10 | coeffcient P6.11 FOV gain P6.12 Reserved P6.13 Reserved M01 output P6.17 | delay time RA-RC/RA- P6.18 | RB-RC output |0.0s~3600.0s delay time P6.20 reserved P6.21 reserved " 0:Positive logic Output terminal | | ° P6.22 | valid mode _ | ":Negative logic 00 oe selection NZ200 Series User's Manual Code Parameter Name Setting Range |Group P7: Operation Panel and Display P7.00 Output power correction factor| 0.0-200.0 P7.02 Reserved STOP/RESET key function O:STOP/RESET key enabled only in operation panel control 1:STOP/RESET key enabled in any operation mode P7.03 LED display running parameters 1 Q000-FFFF Bit0O: Running frequency 1 (Hz) BitO1: Set frequency (Hz) Bit02: Bus voltage (V) Bit03: Output voltage (V) Bit04: Output current (A) Bit05: Output power (kW) Bit06: Output torque (%) Bit07: S input status Bit08: M01 output status Bit09:FIV voltage (V) Bit10: FIC voltage (V) Bit11: Reserved Bit12: Count value Bit13: Length value Bit14: Load speed display Bit15: PID setting 16 List of Function Parameters Function Code Parameter Name Setting Range Default Property P7.04 P7.05 P7.06 LED display running parameters 2 LED display ‘stop parameters Load speed display coefficient O000-FFFF Bit0O: PID feedback Bit01: PLC stage Bit02: Pulse setting frequency(kHz) Bit03: Running frequency 2 (Hz) Bit04: Remaining running time Bit0S: FIV voltage before correction (V) Bit06: FIC voltage before correction (V) BitO7: Reserved Bit08: Linear speed Bit09: Current power-on time(Hour) Bit10: Current running time (min) Bit11: Pulse setting frequency(Hz) Bit12: Communication setting value Bit13: Reserved Bit14: Main frequency X display(Hz) Bit15:Auxiliary frequency Y BitOO: Set frequency (Hz) Bit01: Bus voltage (V) Bit02: S input status Bit03: MO1 output status Bit04: FIV voltage (V) Bit05: FIC voltage (V) Bit06: Reserved Bit07: Count value Bit08: Length value Bit09: PLC stage Bit10: Load speed Bit11: PID setting Bit12: Pulse setting frequency(kHz) Bit13: PID feedback value 0.0001~6.5000 1,0000 bg 17 NZ200 Series User's Manual Function Parameter Code Name Seting Renve Heatsink P7.07 | temperature of |0.0°C~150.0°C inverter Temporary a 2 P7.08 fiwara version! 0.0°C~150.0°C P7.g | Accumulative Tunning time P7.10 reserved p7.11 | Software version Numbers of |0: 0 decimal place P7.12 decimal 1: 1 decimal place . places for load |2: 2 decimal places speed display |3: 3 decimal places p7.13 | Accumulative on, assash power-on time Accumulative P7.14 power OkW~65535kWh consumption |Group P8: Auxiliary Functions JOG running P8.00 | “Frequency JOG P8.01 | acceleration time JOG P8.02 | deceleration time Acceleration P8.03 time 2 Deceleration P8.04 time 2 Acceleration P6.06 time 3 Deceleration P8.06 time 3 Acceleration PbOr time 4 Deceleration P8.08 | time 4 8.09 | “UMP Fequency|o qorz-maximum frequency 18 List of Function Parameters ee Faonetet Setting Range 8.10 [UTP Fequency lo gor iz~maximum frequency P8.11 Smee 0.00Hz~maximum frequency Forward/ P8.12 |Reverse rotation] 0.0s~3000.0s dead-zone time 0: Enabled P8.13 | Reverse control 1: Disabled Running made when set 0: Run at frequency lower limit P8.14 | frequency lower| 1: Stop than frequency |2: Run at zero speed lower limit P8.15 | Droop control |0.00Hz~10.00Hz Accumulative P8.16 | power-on time |Oh~65000h threshold Accumulative P8.17 | running time |Oh~65000h threshold Startup P8.18 protection Frequency P8.19 detection 0.00Hz~maximum frequency value(FDT1) Frequency P8.20 detection 0.0%~100.0% (FDT1 level ) hysterasis(FDT1) Detection range i . P8.21 | of frequency rogtorey) (riaximum reached Jump frequency during 0: Disabled P8.22 | acceleration! |1: Enabled 9 * deceleration Frequency switchover point between P8.25 | acceleration |0.00Hz~maximum frequency 0.00Hz * time 1 and acceleration time 2 19 NZ200 Series User's Manual Function Code Parameter Name Setting Range P8.26 Frequency switchover point between deceleration time 1 and deceleration time 2 0.00Hz~maximum frequency P8.27 Terminal JOG preferred 0: Disabled 4: Enabled P8.28 P8.29 Frequency detection value FDT2) Frequency detection hysteresis (FDT2) 0.G0Hz~maximum frequency 0.0%~100.0% (FDT2 level ) P8.30 Any frequency reaching detection value 1 0,00Hz~maximum frequency P8.31 P8.32 P8.33 P8.34 Any frequency reaching detection amplitude 1 Any frequency reaching detection value 2 Any frequency reaching detection Zero current detection level 0,0%~100.0% (maximum frequency ) 0.G0Hz~maximum frequency 0.0%~100.0% (maximum frequency ) 0.0%~300.0% 100.0% for rated motor current} P8.35 P8.36 Zero current detection delay time Output over current threshold 0.01s~600.00s 0.0% {no detection ) 0.1%~300.0% (rated motor 200.0% current ) P8.37 Output over current detection delay time 0.00s~600.00s 0.00s 20 List of Function Parameters Function Parameter code Rare Setting Range Any current |0.0%~300.0% (rated motor P8.38 reaching 41 ‘ Any current P8.39 reaching 1 amplitude P8.40 Any current |0.0%~300.0% (rated motor ‘ reaching 2 _|current) Any current mea react 92 cate (rated motor amplitude P8.42 | Timing function |0:Disabled 1:Enabled 0: P8.44 41: FIV i «12: FIC pa.ag | Ting duration !3: reserved 100% of analog input corresponds to the value of P8.44 P8.44 | Timing duration |0.0Min~6500.0Min FIV input P8.45 | voltage lower |0.G0V~P8.46 limit FIV input P8.46 | voltage upper |P8.45~10.00V innit Module P8.47 | temperature threshold P8.48 Cooling fan |0: Fan working during running control 1: Fan working continuously Wakeu Dormant frequency (P8.51 P8.49 Fiageee quency ( ) Wakeup delay P8.50 the: P8.51 Dormant 0.00Hz~wakeup frequency frequency _|(P8.49 ) Dormant del: P8.52 ime Pe.g3 | Curent muni" /o,oMin~€500.0Min 21 NZ200 Series User's Manual Function) Parameter Code Name Seting Renve (Group P9: Fault and Protection Motor overload |... P8.00 | protection | Disabled selection : Motor overload P9.01 protection gain 0.20~10.00 Motor overload P9.02 warning coefficient Overvoltage Pa0a stall gain Overvoltage P9.04 | stall protective voltage: Over current PS.08: stall gain Over current P9.06 | stall protective |100%~200% current Short-circuit to |, P9.07 | ground upon 9; Biesbled power-on Fault auto reset P9.09 times. M01 action P9.10 |during fault auto Teset Time interval of Po.t1 fault auto reset P9.12 Reserved Output phase |. i», |: Disabled P9.13 | loss protection |1° EP abled 1 * selection 22 List of Function Parameters Function Code Parameter Name P9.14 P9.15 1st fault type 2nd fault type 3rd (latest) fault type Setting Range Default Property 0: No fault 1: Inverter unit protection 2: Overcurrent during acceleration 3: Overcurrent during deceleration - e 4: Overcurrent at constant speed 5: Overvoltage during acceleration 6: Overvoltage during 25: Reserved 26:Accumulative running time 29: Accumulative power-on time reached 30: Load becoming 0 31: PID feedback lost during running 40: With-wave current limit fault 41-43: Reserved 51: Reserved deceleration 7: Overvoltage at constant speed 8; Buffer resistance overload 9; Undervoltage 10: AC drive overload 11: Motor overload 12:Reserved 13: Power output phase loss 14: Module overheat 15: External equipment fault 16: Communication fault 17: Contactor fault 18: Current detection fault 19: Motor auto-tuning fault 20: Reserved 21: EEPROM read-write fault 22: AC drive hardware fault 23: Short circuit to ground : | 23 NZ200 Series User's Manual Function] Parameter Code Name Frequency upon 3rd fault Current upon 3rd fault Bus voltage upon 3rd fault Input terminal P9.20 | status upon 3rd fault Output terminal P9.21 | status upon 3rd fault AC drive status upon 3rd fault Power-on time upon 3rd fault Running time upon 3rd fault Frequency upon 2nd fault Current upon 2nd fault Bus voltage upon 2nd fault lutput terminal P9.30 | status upon 2nd fault Output terminal P9.31 | status upon 2nd fault Frequency upon 2nd fault Current upon 2nd fault Bus voltage upon 2nd fault lutput terminal P9.37 | status upon ist fault Output terminal P9.38 | status upon ist fault Setting Range P9.17 P9.18 P9.19 P9.22 P9.23 P9.24 P9.27 P9.28 P9.29 P9.32 P9.33 P9.34 List of Function Parameters Function Code Parameter Name Setting Range P9.39 Frequency upon ‘st fault P9.40 Current upon Ast fault P9.41 Bus voltage upon 3rd fault P9.42 P9.43 lutput terminal ‘status upon 1st fault Output terminal status upon 1st fault P9.44 Frequency upon Ast fault P9.47 Fault protection action selection 1 Unit's digit:Motor overload(OL1) 0:Coast to stop 1:Stop according to the stop made 2:Continue to run Ten's digit:Reserved Hundred's digit:Power output phase loss(LO) Thousand's digit:External equipment fault(EF) Ten thousand's digit:Communication fault(CE) 00000 P9.48 Fault protection action selection 2 1:Stop according to the stop mode Hundred's digit:Reserved Thousand's digit:Reserved Ten thousand's digit:Accumulative running time reached(END1) 25 NZ200 Series User's Manual Function) Parameter code Rare Setting Range Default Property Unit's digit: reserved Unit's digit:Reserved 0:Coast to stop 1:Stop according to the stop 1:Stop according to the stop mode 2:Continue to run Hundred's digit:Accumulative power-on time reached(END2) 0:Coast to stop 1:Stop according to the stop mode 2:Continue to run Fault protection P9.49 | action selection 3 1:Stop accarding to the stop mode 2:Continue to run at 7% of rated motor frequency and resume to the set frequency if the load recovers ‘Ten thousand's digit: PID feedback loss of running 0:Coast to stop 1:Stop according to the stop mode 2:Continue to run P9.50 Reserved 0:Current running frequency Frequency | 1:Set frequency selection for |2:Frequency upper limit P94 continuing to |3:Frequency lower limit run 4:Backup frequency upon abnormalit Backup P9.56 | frequency upon |60.0%~100.0% abnormality P9.56 reserved P9.57 reserved P9.58 reserved List of Function Parameters Function Code Parameter Name Setting Range P9.59 Action selection |0: Invalid ‘at instantaneous} 1: Decelerate power failure |2: Decelerate to stop P9.60 Action pause judging voltage at instantaneous power failure 0.0%~100.0% P9.62 Voltage rally judging time at © instantaneous efo0s-"100.00s power failure Action judging voltage at =| 60.0%~100.0% (standard bus instantaneous |voltage ) power failure P9.63 Protection upon = 10: Disabled load becoming |; ° 0 1: Enabled P9.64 P9.65 Detection level of load |0.0~100.0% becoming 0 Detection time of load becoming 0 P9.67 P9.68 Reserved P9.69 P9.70 pao | PD setting 4:PULSE setting(S3) 5:Communication setting 6:Multi-reference PID digital 7 PA.O1 setting 0.0%~100.0% 50.0% * 27 NZ200 Series User's Manual Function) Parameter Code Name Seting Renve Pa.og | PID feedback |4 PULSE setting(S3) §:Communication setting 6:FIV+FIC 7-MAX(FIV|, IFich IVI. PID action 0: Forward = PAS direction 1: Reverse action PID setting |) 55, PAD feedback range ae Proportional = PA.OS gain Kp1 90.0~100.0 PA.06 | Integral time Ti1|0.01s~10.00s pacr | Piferential ime 'o ooos~10.000s Cut-off frequency of 7 , PA.0O8 PID reverse 0.00~maximum frequency rotation Pag | PIP GVation Io 0%4~100.0% Pato | PID differential /o qo%4~100.00% PID setting PA11 change time 0.00~650.00s PID feedback PAN: filter time PID output filter PAA13 time PA14 Reserved Proportional PAIS gain Kp2 PA.16 |Integral time Ti2|0.01s~10.00s 2.00s * Patz | Piferentia m2 10 aoos~10.000s 0.0008 | + PID parameter O:No switchover PA18 | switchover _|1‘Switchover via S 0 * condition 2:Automatic switchover based on deviation 28 List of Function Parameters Function Parameter code Rare Setting Range PID parameter PA9 switchover |0.0%~PA.20 deviation 1 PID parameter PA.20 switchover |PA.19~100.0% deviation 2 PA.21 | PID initial value |0.0%~100.0% 0.0% * PA.22 | PID initial value 0.00~650.00s 00s de holding time |"" : Maximum deviation PA.23 | between two |0.00%~100.00% PID outputs in forward Maximum deviation PA.24 | between two |0.00%~100.00% PID outputs in reverse Unit's digit:Integral separated O:Invalid pa25 | PlDintegral |Ten's digit Whether to stop property integral operation when the output reaches 0:Continue integral operation 1:Stop integral operation Detection value |0.0%: Not judging feedback of PID feedback |loss loss 0.1%~100.0% Detection time of PID 0.0s~20.0s feedback loss Pb.00 Pb.01 0: Relative to the central Swing frequency] frequency setting mode |1: Relative to the maximum frequen Swing frequency 9 5,-100.0% amplitude Pb.02 Jump frequency = amplitude bce 29 NZ200 Series User's Manual Function Parameter code Rare Setting Range Pb.o3 [Swing Nenveny|o 45-3000.08 Triangular wave Pb.04 rising time —|0.1%~100.0% coefficient Pb.0S Set length Pb.06 | Actuallength |Om~65535m Number of Pb.07 pulses per meter Pb.08 | Set count value |1~65535 Designated PpO9 count value 'Group PC: Multi-Reference and Simple PLC Function PC.00 | Reference 0 PC.01 | Reference 1 PC.02 | Reference 2 PC.03 | Reference 3 |-100.0%~100.0% PC.04 | Reference 4_|-100.0%~100.0% PC.05 | Reference 5 |-100.0%~100.0% PC.06 | Reference 6 PC.07 | Reference 7 PC.08 | Reference 8 PC.09 | Reference 9 . PC.10 | Reference10 |-100.0%~100.0% PC.11 | Reference11 |-100.0%~100.0% PC.12 | Reference12 |-100.0%~100.0% 0.0% * PC.13 | Reference13 |-100.0%~100.0% 0.0% * PC.14 | Reference14 |-100.0%~100.0% 0.0% * PC.15 | Reference15 |-100.0%~100.0% 0.0% * 0:Stop after the AC drive runs ‘one cycle Simple PLC |1:Keep final values after the BC.16) arenas mode |AC ans Tuns one cycle 0 * 2:Repeat after the AC drive tuns one cycle 30 List of Function Parameters Function Code Parameter Rare Setting Range PC.17 Unit's digit:Retentive upon power failure Simple PLC retentive selection Ten's digit:Retentive upon stop 0:No 1:Y¥es PC.18 Running time of simple PLC |0.0s(h)~6553.5s(h) reference 0 PC.19 Acceleration/ deceleration time of simple PLC reference 0| PC.20 PC.21 Running time reference 1 Acceleration/ deceleration time of simple PLC reference 1 PC.22 PC.23 PC.24 Running time of simple PLC |0.0s(h)~6553.5s(h) reference 2 Acceleration/ deceleration time of simple PLC reference 2| Running time of simple PLC |0.0s(h)~6553.5s(h) reference 3 PC.25 Acceleration/ deceleration time of simple PLC reference 3} PC.26 PC.27 Running time Acceleration/ deceleration time of simple PLC reference 4 31 NZ200 Series User's Manual Function Code Parameter Name Setting Range PC.28 Running time of simple PLC |0.0s(h)~6553.5s(h) reference 5 PC.29 Acceleration/ deceleration time of simple PLC reference 5| PC.30 PC.31 Running time Acceleration/ deceleration time of simple PLC reference 6} PC.32 PC.33 PC.34 Running time of simple PLC |0.0s(h)~6553.5s(h) reference 7 Acceleration/ deceleration time of simple PLC reference 7| Running time of simple PLC. |0.0s(h)~6553.5s(h) reference 8 PC.35 Acceleration/ deceleration time of simple PLC reference 8} PC.36 PC.37 Running time reference 9 Acceleration/ deceleration time of simple PLC reference 9) PC.38 Running time of simple PLC |0.0s(h)~6553.5s(h) reference 10 PC.39 Acceleration/ deceleration time of simple PLC reference 10 32 List of Function Parameters Function Code Parameter Name Setting Range PC.40 Running time of simple PLC reference 11 0.0s (h)~6500.0s (h) PC.41 Acceleration/ deceleration time of simple PLC reference “1 PC.42 PC.43 Running time of simple PLC reference 12 Acceleration/ deceleration time of simple PLC reference 12 PC.44 Running time of simple PLC reference 13 0.0s (h)~6500.0s (h) PC.45 PC.46 Acceleration/ deceleration time of simple PLC reference 13 Running time of simple PLC reference 14 0.08 (h)~6500.0s (h) PC.47 PC.48 Acceleration/ deceleration time of simple PLC reference 14 Running time of simple PLC reference 15 0.0s (h)~6500.0s (h) PC.49 Acceleration/ deceleration time of simple PLC reference 15 PC.50 Time unit of simple PLC running 33 NZ200 Series User's Manual Function Parameter |Group PD: Communication Parameters code Rare Setting Range Default Property 0: Set by PC.00 1: FIV 2: FICIAVI 3: reserved pc.s1 | Reference 0 |. BULSE setting source 5: PID Set by preset frequency {P010), modified via terminal Unit's digit: MODBUS PD.0O Baud rate 8:57600BPS 9:115200BPS, Ten's digit :Reserved Hundred's digit:Reserved |Thousand's digit:Reserved 0: No check, data format <8,N,2> 1: Even parity check, data PD.01 | Data format |format<8.E,1> 3: No check, data format <8,N,1> Valid for Modbus PD.02 | Local address_|1~247, 0: Broadcast address PD.03 | Response delay Communication PD.04 timeout Unit's digit: Modbus protocol 0: Non-standard Modbus pp.05 |Modbus protocol protocol 1 * 1: Standard Modbus protocol Ten's digit: reserved ‘Communication | ,, PD.06 | reading current |¢° 0-004 0 Es resolution _ |Group PE: reserved 34 List of Function Parameters Function Code Parameter Rare Setting Range Group PP: User-Defined Function Codes PP.00. User password |0~65535. PP.O1 0: No operation settings except motor parameters: 02: Clear records coe ‘control selection] 1: Torque control : Digital setting (C0.03 ) tFIV Torque setting |," ro 60.01 | sourcein | 7 OT oe sett torque control |." setting ; Communication setting : MIN (FIV,FIC ) : MAX (FIV,FIC ) Torque digital C0.03 setting in -200.0%~200.0% Forward 0.05 frequency i |0-00H2~maximum frequency torque control Reverse C0.06 reqaeney i 0.00Hz~maximum frequency torque control Acceleration 0.07 | time in torque control Deceleration C0.08 | time in torque control Group C1-C4: reserved |Group C5: Control Optimization Parameters 5.00 PWM switchover frequency upper| lirnit 0.00Hz~15.00Hz 5.01 PWM modulation mode 0: Asynchronous modulation 1: Synchronous modulation 35 NZ200 Series User's Manual Function) Parameter Code Name Setting Range Dead zone |0: No compensation 5.02 | compensation |1: Compensation mode 1 mode selection |2: Compensation mode 2 0: Random PWM invalid C5.03 se 1—10:PWM carrier frequency random depth Rapid current |0: Disabled scaled limit __|1: Enabled Current C5.05 detection 0~100 compensation Undervoltage C5.06 threshold 60.0%~140.0% SFVC 0: No optimization 5.07 | optimization | 1: Optimization mode 1 mode selection |2: Optimization mode 2 |Group C6: Fl Curve Setting(Fl is FIV or FIC) Fl curve 4 6.00 minimum Input -10.00V~C6.02 Corresponding setting of Fl curve 4 minimum input Fi curve 4 C6.02 |. r “ C6.00~C6.04 inflexion 1 input C6.01 -100.0%~+100.0% Corresponding setting of FI curve 4 inflexion’ 1 input 6.03 -100.0%~+100.0% Fl curve 4 Ca.04 inflexion 2 input C6,02~C6.08 Corresponding setting of FI curve 4 inflexion’ 2 input 6.05 -100.0%~+100.0% Fi curve 4 6.08 maximum input C6.06~+10.00V Corresponding setting of Fl curve 4 maximum input Fl curve 5 minimum input 6.07 -100.0%~+100.0% 6.08 36 List of Function Parameters Function Parameter Code Name Seting Renve Corresponding setting of C6.09 Flcurve5 -100.0%~+100.0% minimum input Fl curve 5 B~CE, Gal inflexion 1 input See i Corresponding setting of Fl 6.11 curve 5 inflexion -100.0%~+100.0% 1 input Fl curve 5 0-C6, one inflexion 2 input cae le Corresponding setting of FI C613 curve 5 inflexion -100.0%~+100.0% 2 input co.14|_ Flouves leg 12-+40.00v maximum input Corresponding C6.15 | settingofFl |-100.0%~+100.0% curve cei | MUTA PRIMO | 109.0% ~100.0% Jump amplitude i C6.17 of FIV input 0.0%~100.0% Jump point of |, 7 C6.18 FIC input 100.0%~100.0% Jump amplitude = C6.19 of FIC input 0.0%~100.0% PID Sleep ~ C9.00 frequency O~PO0.12 C9.01 | PID Sleep Time 0 ~ 5000.08 PID wake-up ~ C902 value 0 ~ 100.0 % Group CC: FI/FO Correction FIV measured C.00 | “ \ettage 1 FIV displayed cC.01 voltage 1 0.500V~4.000V FIV measured cC.02 voltage 2 6.000V~9.999V FIV displayed CC.03 voltage 2 6.000V~9.999V 37 NZ200 Series User's Manual Function) Parameter Code Name Se eee cc.o4 eeoeeet 0.500V~4.,000V cc.05 eSeeok 0.500V~4.000V cc.06 raeee 6.000V-9.999V cc.o7 reeen 6.000V~9.999V CC.08 Reserved cc.09 Reserved CC.10 Reserved co.11 Reserved cc.12 oe 0.500V~4.,000V ec.1s | FOY measired lp soov~4.o00v co.14 ee 6.000V~9.999v cc.1s Oe 6.000V~9,999V CC.16 Reserved CC.17 Reserved CC.18 Reserved cc.19 Reserved lll +DL Dll Pd Group D0: Monitoring Parameters Function Parameter Name Unit DO.00 Running frequency(Hz) 0.01Hz D0.01 Set fraquency(Hz) 0.01Hz D0.02 DO0.03 38 List of Function Parameters Dae Parameter Name D0.04 Output current(A) DO0.05 Output power(kW) D0.06 Output torque(%) DO0.07 S input state D0.08 MO1 output state D0.09 FIV voltage(V) 0.01V DO.10 FIC voltage(V) 0.01V DO.11 DO0.12 Count value DO.13 Length DO.14 Load speed DO.15 PID setting D016 PID feedback DO.17 PLCstage DO.18 Input pulse frequency DO0.19 Reserved DO.20 Remaining running time DO0.21 FIV voltage before correction Daas D0.25 On the current time DO.26 The current running time D0.27 Pulse input frequency D0.28 Communication setting value DO0.29 Reserved DO.30 Reserved DO.31 Auxiliary frequency Y DO0.33 Reserved 39 NZ200 Series User's Manual Dae Parameter Name D0.34 Motor temperature D0.35 Target torque DO0.36 Reserved DO0.37 Power factor angle DO0.38 Reserved D0.39 Target voltage upon V/F separation D0.40 Output voltage upon V/F separation D0.42 Reserved D043 Reserved D0.44 Reserved D0.45 Current fault code 0 40 We reserve the right of this manual contained information change without prior notice 2019.06

También podría gustarte