Electrolytic processes

A series copper refinery used tanks measuring Inside 16 ft by 60 in Deep by 62 in.Wide.


Each tank contains 610 anode plates, each 12 in wide, arranged in fives across the
tank, masking 122 large anodes. End anodes are against the ends of the tanks.
Separate plates are 0.40 m thick.
The solution stands ½ in. Above the upper Edge of the plates. The lower ends are 2 ½
in. From the bottom of the tank.
Voltaje per tank,16. Current density 20 amp per aquare foot. Ampere efficiency, 75 per
cent.
1 The average distance between plates
2 The thicknees of copper deposit, per day.
3 The resistivity of the solution
4 The number of thanks required to furnish 550 short tons of copper, per day.
5 The electric power(kilowatts ) required to run the plant.

Una serie de refinerías de cobre utilizó tanques que miden el interior


de 16 pies por 60 pulgadas de profundidad por 62 pulgadas de
ancho. Cada tanque contiene 610 placas anódicas, cada una de 12
pulgadas de ancho, dispuestas en cinco a través del tanque,
enmascarando 122 ánodos grandes. Los ánodos finales están
contra los extremos de los tanques. Las placas separadas tienen
0,40 m de espesor.
La solución se encuentra a ½ pulgadas. Por encima del borde
superior de las placas. Los extremos inferiores son de 2 ½
pulgadas. Desde el fondo del tanque.
Voltaje por tanque, 16. Densidad de corriente 20 amperios por pie
cuadrado. Eficiencia de amperios, 75 por ciento.
1 La distancia promedio entre placas
2 Los espesores de depósito de cobre, por día.
3 La resistividad de la solución.
4 La cantidad de agradecimientos necesarios para suministrar 550
toneladas cortas de cobre por día.
5 La energía eléctrica (kilovatios) requerida para operar la planta .