Está en la página 1de 9

Endress+Hauser, SC – Services

Work Instruction for


Performance Verification of
Endress+Hauser Proservo (NMS5)
Classification
Internal
All rights reserved. Passing on and copying of this document and communication
of its contents not permitted

Title: Work Instruction for Performance Verification of


Endress+Hauser Proservo (NMS5)
Version: Document number: Page:
02.14 BW01017H/00/EN/02.14 1/9
Work Instruction for
Performance Verification of
Endress+Hauser Proservo (NMS5)
BW01017H/00/EN/02.14
Revisions:

Change Description: Initial Release

Authors Group:
Ricardo Brueggemann Project Engineer IMS PC Maulburg

Approvers:
Dave Marriner Field Service Support Engineer SC United Kingdom
Christophe Pujol Service Portfolio Manager Consult AG Sales Support

Service Office
Page 2 of 9 © Endress+Hauser
Template Revision: BF01007H/88/EN/02.14  Version 02.14
Work Instruction for
Performance Verification of
Endress+Hauser Proservo (NMS5)
BW01017H/00/EN/02.14

Contents
1.0 Purpose ............................................................................................................................................................. 4
2.0 Warning and Cautions..................................................................................................................................... 4
3.0 Reference Documents ...................................................................................................................................... 4
4.0 Tools and Equipment ....................................................................................................................................... 4
5.0 Wearing parts and Consumables to be used ................................................................................................. 4
6.0 Work Instructions ............................................................................................................................................ 5
7.0 Reporting .......................................................................................................................................................... 8
8.0 Definitions ........................................................................................................................................................ 8

Service Office
Page 3 of 9 © Endress+Hauser
Template Revision: BF01007H/88/EN/02.14  Version 02.14
Work Instruction for
Performance Verification of
Endress+Hauser Proservo (NMS5)
BW01017H/00/EN/02.14

1.0 Purpose

This documentation is solely meant to guide a simple performance verification procedure on the Proservo
NMS5 series Servo Level gauge (hereafter Proservo) for during normal operating period.

2.0 Warning and Cautions

The Proservo is an Ex device for use in Hazardous Area. With this in mind the proper Hazardous Area
precautions should be taken into account. For example “Hot Work Permit” should be prepared as well and all
local customer conditions must be taken into account

All local requirements for personal protective equipment (PPE), such as Safety Shoes, Protective Helmet,
Flame retardant, highly visible and antistatic Jacket or Overalls, must be used. Additional local regulations for
training, environmental or other needs and approvals must be considered.

It is important that for tanks and applications with the following conditions to abide by these warnings:
• Pressurized and / or blanketed: Maintenance hatch can NOT be opened
• Chemically aggressive: Dipping can NOT be performed

The following conditions must be satisfied prior to conducting a successful verification.


• Measurement mode of the Proservo is in “LEVEL”
• The tank is neither FILLING nor DRAINING (Proservo reading must be stable)
• Any initial calibration reports /commissioning sheets are available

3.0 Reference Documents

Operation Manual: BA1001N08

4.0 Tools and Equipment

A certified measuring tape (Dip Tape) should be used to compare to data. Please register the last calibrated
stamp/date. Depending on the internal regulation at the site the dip tape should be used by the customer

5.0 Wearing parts and Consumables to be used

Not applicable

Service Office
Page 4 of 9 © Endress+Hauser
Template Revision: BF01007H/88/EN/02.14  Version 02.14
Work Instruction for
Performance Verification of
Endress+Hauser Proservo (NMS5)
BW01017H/00/EN/02.14
6.0 Work Instructions

Here are the summary details for verification of the Proservo (NMS5)

Step Procedure Verification Note


Gauge Reading Reading value should NOT
Confirm & Note current liquid fluctuate more than +/- 2mm
level at the home position. Steady liquid level reading on (If it does, wait until liquid
(Hand Dip and Servo level) LCD level stabilizes)

Guideline:
Displacer status on LCD must
1 indicate “BAL” consistently

Guideline:
Deviation between the average of
3 Hand Dips and Servo level less
than “+/- 4mm”
If more than 4mm set gauge to
the average of 3 hand dips
Operation

Hoist displacer by “UP” Level value raises and stops in


command, according to the the drum housing or pre-set
operation manual on page 50. position of “Upper Stop”.

Service Office
Page 5 of 9 © Endress+Hauser
Template Revision: BF01007H/88/EN/02.14  Version 02.14
Work Instruction for
Performance Verification of
Endress+Hauser Proservo (NMS5)
BW01017H/00/EN/02.14
Reference Position

Confirm the presence of displacer Displacer stowed in the Guide wires and PTB
and position. Calibration Window. displacer are not applicable.

Guideline: Warning!
Displacer ring positions stays +/- The displacer must be visible
10mm referred to previously in the window before the
commission sheet. isolation valve is closed,
3 otherwise the displacer wire
will be cut and the displacer
lost !!

Measured Weight Measured weight may


Compare the actual displacer fluctuate by swinging
Confirm & Note displacer weight to the specified weight at displacer. Wait until the
measured weight at Matrix Matrix position GVH342. movement settles.
position GVH370
4 Guideline: Caution!
Difference within “+/- 3g” If measured weight is outside
the tolerance follow displacer
Perform “Displacer Weight configuration procedure in
calibration” if necessary. operation instruction
manual.
Repeatability
Verification report
Lower displacer by “LEVEL” Level value returns to “Step 1” Check the box if repeatability
command according to operation stays within guideline
manual on page 50. Guideline: tolerance.
Returned level reading tolerance
5
within “+/- 2mm” Caution!
If measured level does not
returns to Step 1 value within
tolerance, contact EH service
engineers for technical
information.

Service Office
Page 6 of 9 © Endress+Hauser
Template Revision: BF01007H/88/EN/02.14  Version 02.14
Work Instruction for
Performance Verification of
Endress+Hauser Proservo (NMS5)
BW01017H/00/EN/02.14
Balance Weight on Liquid

First enter the access code 51. Guideline:

Note Balance Volume and Upper


density according to the Matrix
position GVH 344 and GVH 005.

e.g.:

Guideline for WL and WD:


Calculate and note the WL. Difference within “+/- 2 g”

Compare the calculated weight to


the weight in liquid at matrix
position GVH 370.

Service Office
Page 7 of 9 © Endress+Hauser
Template Revision: BF01007H/88/EN/02.14  Version 02.14
Work Instruction for
Performance Verification of
Endress+Hauser Proservo (NMS5)
BW01017H/00/EN/02.14
7.0 Reporting

Recommended verification sheet (should be added to the commission sheet).

Date: Device Serial No: Order Code: Tank identity

Balance Volume: Upper Density: Signature:

1. Time/Date 2. Hand Dip 3. Proservo 4. Deviation 5. Displacer 6. Weight in 7. Signature


Level Level (between 2. & 3.) Weight/ liquid
/ Repeatability Upper
Density (if
changed)
/□
/□
/□
/□
/□
/□
/□
/□
/□

8.0 Definitions

Proservo = NMS5-XXXXXXX
Hand Dip Level = measurement on measuring tape

Service Office
Page 8 of 9 © Endress+Hauser
Template Revision: BF01007H/88/EN/02.14  Version 02.14
Work Instruction for
Performance Verification of
Endress+Hauser Proservo (NMS5)
BW01017H/00/EN/02.14

Copyright Statement and Disclaimer

This document and its content are the property of Endress+Hauser Consult AG and its licensors (“Endress+Hauser”);
copyright laws in various countries may apply.
Any reproduction or distribution of this document (including parts of it) is prohibited without the prior written consent
of Endress+Hauser.
Any trademarks and trade names mentioned in this document remain the sole property of Endress+Hauser or the
relevant owner.
All other intellectual property rights, particularly but not limited to patents and patent applications shall be reserved
and no license or other right to use whatsoever shall be granted hereunder.
This document shall only be legally binding in connection with a separate agreement between the service provider and
the customer. The contractual obligations stipulated in such separate agreement shall prevail.
Endress+Hauser may not make any warranties, express or implied, with respect to the accuracy, the completeness or the
technical or commercial usefulness of this document.
Endress+Hauser may modify or replace this document any time.

September 2012
Endress+Hauser Consult AG, Kaegenstrasse 2, CH-4153 Reinach, Switzerland

Service Office
Page 9 of 9 © Endress+Hauser
Template Revision: BF01007H/88/EN/02.14  Version 02.14