Está en la página 1de 18

Project: J6A ETAP Page: 1

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Electrical Transient Analyzer Program

Load Flow Analysis

Loading Category (2): Normal

Generation Category (2): Normal

Load Diversity Factor: Global

Constant kVA=100%, Constant Z=100%, Generic=100%, Constant I=100%

Swing V-Control Load Total


Number of Buses: 3 0 28 31

Line/Cable/
XFMR2 XFMR3 Reactor Busway Impedance Tie PD Total
Number of Branches: 0 0 0 21 0 7 28

Method of Solution: Adaptive Newton-Raphson Method

Maximum No. of Iteration: 99

Precision of Solution: 0.0001000

System Frequency: 50.00 Hz

Unit System: English

Project Filename: J6A_Turbine_Gen_Rev-1

Output Filename: C:\Users\SSM Engineering\Downloads\J6A_Turbine_Gen\J6A_Turbine_Gen\Untitled.lfr


Project: J6A ETAP Page: 2

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Adjustments

Apply Individual
Tolerance Adjustments /Global Percent

Transformer Impedance: Yes Individual

Reactor Impedance: Yes Individual

Overload Heater Resistance: No

Transmission Line Length: No

Cable / Busway Length: No

Apply Individual
Temperature Correction Adjustments /Global Degree C

Transmission Line Resistance: Yes Individual

Cable / Busway Resistance: Yes Individual


Project: J6A ETAP Page: 3

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Bus Input Data

Load

Bus Initial Voltage Constant kVA Constant Z Constant I Generic

ID V Sub-sys % Mag. Ang. MW Mvar MW Mvar MW Mvar MW Mvar

Bus1 400 1 100.0 0.0

Bus2 400 1 100.0 0.0

Bus3 400 1 100.0 0.0 0.007 0.005 0.002 0.001

Bus4 400 1 100.0 0.0

Bus6 400 1 99.4 -0.2 0.067 0.000 0.017 0.000

Bus7 400 1 99.4 -0.1 0.097 0.041

Bus8 400 1 100.0 0.0 0.003 0.002

Bus9 400 1 100.0 0.0

Bus10 400 1 100.0 0.0 0.002 0.000

Bus11 400 1 100.0 0.0

CP-E-7305 400 1 100.0 0.0

CP-EL-7501 400 1 99.5 0.2

CP-EL-7504 400 1 99.7 -0.1 0.012 0.007

CP-EL-7509 400 1 100.0 0.0

CP-EL-7801 400 1 100.0 0.0 0.005 0.004

CP-EL-7803-1 400 1 99.7 -0.1

CP-EL-7804 400 1 100.0 0.0 0.004 0.003

CP-EN-7000 400 1 100.0 0.0

CP-EN-7201 400 1 99.7 -0.1 0.433 0.240 0.002 0.002 0.021 0.000

CP-EN-7202 400 1 99.6 0.0 0.054 0.030

CP-EN-7301 400 1 100.0 0.0 0.240 0.127 0.002 0.002

CP-EN-7304 400 1 100.0 0.0

CT-EL-7510 400 1 100.0 0.0 0.002 0.001

CT-EL-7511 400 1 99.6 0.1

CT-EL-7512 400 1 100.0 0.0

CT-EL-7805 400 1 100.0 0.0 0.004 0.000

CT-EN-7220 400 1 100.0 0.0 0.057 0.031

CT-EN-7302 400 1 99.6 0.1 0.007 0.004

EL-7506 400 1 99.9 0.0 0.008 0.006

PM-3201A~ 400 2 100.0 0.0 0.089 0.056

PM-3201B~ 400 3 100.0 0.0 0.027 0.014

Total Number of Buses: 31 1.101 0.561 0.043 0.019 0.000 0.000 0.024 0.000
Project: J6A ETAP Page: 4

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Generation Bus Voltage Generation Mvar Limits

ID V Type Sub-sys % Mag. Angle MW Mvar % PF Max Min

Bus1 400 Swing 1 100.0 0.0

PM-3201A~ 400 Swing 2 100.0 0.0

PM-3201B~ 400 Swing 3 100.0 0.0

0.000 0.000
Project: J6A ETAP Page: 5

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Line/Cable/Busway Input Data

ohms or siemens/1000 ft per Conductor (Cable) or per Phase (Line/Busway)

Line/Cable/Busway Length

ID Library Size Adj. (ft) % Tol. #/Phase T (°C) R X Y

Cable1 1.0MCUN1 400 65.6 0.0 3 75 0.018605 0.027127 0.0000554

Cable3 1.0MCUN4 25 131.2 0.0 1 75 0.269489 0.024994 0.0000271

Cable4 1.0MCUN4 120 49.2 0.0 1 75 0.056979 0.022250 0.0000457

Cable6 1.0NCUN1 400 65.6 0.0 4 75 0.018605 0.027127 0.0000554

Cable7 1.0MCUN4 185 131.2 0.0 1 75 0.037211 0.022250 0.0000440

Cable9 1.0MCUN4 95 114.8 0.0 1 75 0.071806 0.022250 0.0000437

Cable14 1.0MCUN4 150 114.8 0.0 1 75 0.046223 0.022250 0.0000440

Cable15 1.0MCUN4 50 180.4 0.0 1 75 0.143611 0.024079 0.0000362

Cable16 1.0MCUN4 70 393.7 0.0 1 75 0.099423 0.022860 0.0000398

Cable17 1.0MCUN4 50 49.2 0.0 1 75 0.143611 0.024079 0.0000362

Cable18 1.0MCUN4 50 114.8 0.0 1 75 0.143611 0.024079 0.0000362

Cable19 1.0MCUN4 120 32.8 0.0 1 75 0.056979 0.022250 0.0000457

Cable20 1.0MCUN1 400 98.4 0.0 3 75 0.018605 0.027127 0.0000554

Cable21 1.0MCUN1 185 393.7 0.0 3 75 0.037211 0.028956 0.0000477

Cable22 1.0MCUN4 240 393.7 0.0 1 75 0.028199 0.021946 0.0000477

Cable24 1.0MCUN4 240 393.7 0.0 1 75 0.028199 0.021946 0.0000477

Cable25 1.0MCUN4 95 78.7 0.0 1 75 0.071806 0.022250 0.0000437

Cable28 1.0MCUN1 400 52.5 0.0 2 75 0.018605 0.027127 0.0000554

Cable29 1.0MCUN4 50 180.4 0.0 1 75 0.143611 0.024079 0.0000362

Cable30 1.0MCUN1 400 52.5 0.0 2 75 0.018605 0.027127 0.0000554

Cable35 1.0MCUN4 50 49.2 0.0 1 75 0.143611 0.024079 0.0000362

Line / Cable / Busway resistances are listed at the specified temperatures.


Project: J6A ETAP Page: 6

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Branch Connections

CKT/Branch Connected Bus ID % Impedance, Pos. Seq., 100 MVA Base


ID Type From Bus To Bus R X Z Y

Cable1 Cable CP-EN-7201 CP-EN-7301 25.43 37.08 44.97 0.0000017

Cable3 Cable CP-EN-7301 Bus8 2210.37 205.00 2219.86 0.0000006

Cable4 Cable CP-EN-7201 Bus7 175.26 68.44 188.14 0.0000004

Cable6 Cable Bus1 CP-EN-7201 19.08 27.81 33.73 0.0000023

Cable7 Cable CP-EN-7201 Bus6 305.21 182.50 355.61 0.0000009

Cable9 Cable CP-EN-7201 Bus2 515.34 159.69 539.51 0.0000008

Cable14 Cable CP-EN-7301 CP-EN-7202 331.73 159.69 368.17 0.0000008

Cable15 Cable CP-EN-7201 Bus10 1619.63 271.56 1642.24 0.0000010

Cable16 Cable CP-EN-7301 CT-EN-7302 2446.43 562.50 2510.27 0.0000025

Cable17 Cable CP-EN-7301 EL-7506 441.72 74.06 447.88 0.0000003

Cable18 Cable CP-EN-7301 CP-EL-7501 1030.67 172.81 1045.06 0.0000007

Cable19 Cable CP-EN-7301 CP-EL-7804 116.84 45.63 125.43 0.0000002

Cable20 Cable CP-EN-7201 CP-EN-7000 38.15 55.63 67.45 0.0000026

Cable21 Cable CP-EN-7000 CT-EN-7220 305.21 237.50 386.73 0.0000090

Cable22 Cable CP-EN-7201 Bus3 693.87 540.00 879.24 0.0000030

Cable24 Cable CP-EN-7201 Bus4 693.87 540.00 879.24 0.0000030

Cable25 Cable CP-EN-7301 Bus9 353.37 109.50 369.95 0.0000006

Cable28 Cable CP-EN-7301 CP-EN-7304 30.52 44.50 53.96 0.0000009

Cable29 Cable CP-EN-7201 Bus11 1619.63 271.56 1642.24 0.0000010

Cable30 Cable CP-EN-7304 CP-E-7305 30.52 44.50 53.96 0.0000009

Cable35 Cable CP-EN-7301 CP-EL-7801 441.72 74.06 447.88 0.0000003

CB8 Tie Breakr CP-EN-7301 CP-EL-7509

CB13 Tie Breakr CT-EN-7220 CT-EL-7805

CB17 Tie Breakr CT-EN-7220 CT-EL-7510

CB21 Tie Breakr CT-EN-7220 CT-EL-7512

CB(63A) Tie Breakr CP-EN-7201 CP-EL-7504

CB(63A)8 Tie Breakr CP-EN-7201 CP-EL-7803-1

CB152 Tie Breakr CT-EN-7302 CT-EL-7511


Project: J6A ETAP Page: 7

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Equipment Cable Input Data

ohms or siemens/1000 ft per Conductor O/L Heater

Equipment Cable Equipment Length Resistance

ID ID Type Library Size Adj. (ft) % Tol #/ph T (°C) R X Y Adj.(ohm) % Tol

Cable117 30-MOV-001 Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable39 83P001A Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable110 83P001B Ind. Motor 1.0NCUN3 2.5 164.0 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable40 83P002A Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable111 83P002B Ind. Motor 1.0NCUN3 2.5 141.1 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

P-1172 83P003A Ind. Motor 1.0NCUN3 4.0 128.0 0.0 1 75 1.70647 .02835 .0000175 .0000 0.0

P-2 83P003B Ind. Motor 1.0NCUN3 4.0 128.0 0.0 1 75 1.70647 .02835 .0000175 .0000 0.0

Cable38 83-PM-005A Ind. Motor 1.0NCUN3 6.0 196.9 0.0 1 75 1.13959 .02713 .0000202 .0000 0.0

Cable109 83-PM-005B Ind. Motor 1.0NCUN3 2.5 147.6 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable80 AM-7001A Ind. Motor 1.0MCUN3 35 114.8 0.0 1 75 .19449 .02438 .0000309 .0000 0.0

Cable33 BM-7001C-1 Ind. Motor 1.0MCUN3 35 98.4 0.0 1 75 .19449 .02438 .0000309 .0000 0.0

Cable81 CP-EK-5401 Ind. Motor 1.0NCUN3 2.5 147.6 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable23 CT-KT-3101 Ind. Motor 1.0MCUN3 70 196.9 0.0 1 75 .09942 .02286 .0000398 .0000 0.0

Cable77 KM-6101A Ind. Motor 1.0MCUN3 35 131.2 0.0 1 75 .19449 .02438 .0000309 .0000 0.0

Cable73 KM-6101B Ind. Motor 1.0MCUN3 35 206.7 0.0 1 75 .19449 .02438 .0000309 .0000 0.0

Cable101 KM-6101C Ind. Motor 1.0NCUN3 35 147.6 0.0 1 75 .19449 .02438 .0000309 .0000 0.0

Cable69 LM-5601 Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable71 LM-5601B Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable49 PM-3201A Ind. Motor 1.0NCUN3 150 164.0 0.0 1 75 .04622 .02225 .0000440 .0000 0.0

Cable116 PM-3201B Ind. Motor 1.0NCUN3 150 196.9 0.0 1 75 .04622 .02225 .0000440 .0000 0.0

Cable47 PM-3203A Ind. Motor 1.0NCUN3 25 114.8 0.0 1 75 .26949 .02499 .0000271 .0000 0.0

Cable113 PM-3203B Ind. Motor 1.0NCUN3 16 301.8 0.0 1 75 .42444 .02438 .0000296 .0000 0.0

Cable61 PM-3302A Ind. Motor 1.0NCUN3 16 147.6 0.0 1 75 .42444 .02438 .0000296 .0000 0.0

Cable62 PM-3303A Ind. Motor 1.0NCUN3 2.5 147.6 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable97 PM-3303B Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable68 PM-5001 Ind. Motor 1.0MCUN4 120 65.6 0.0 1 75 .05698 .02225 .0000457 .0000 0.0

Cable5 PM-5301 Ind. Motor 1.0NCUN3 2.5 147.6 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable8 PM-5302 Ind. Motor 1.0NCUN3 2.5 164.0 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable10 PM-5303A Ind. Motor 1.0NCUN3 2.5 141.1 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable41 PM-5303B Ind. Motor 1.0NCUN3 2.5 147.6 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable46 PM-5304A Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable93 PM-5304B Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable120 PM-5305 Ind. Motor 1.0NCUN3 2.5 164.0 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0
Project: J6A ETAP Page: 8

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

ohms or siemens/1000 ft per Conductor O/L Heater

Equipment Cable Equipment Length Resistance

ID ID Type Library Size Adj. (ft) % Tol #/ph T (°C) R X Y Adj.(ohm) % Tol

Cable44 PM-5306 Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable83 PM-5307 Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable79 PM-5308 Ind. Motor 1.0NCUN3 10 213.3 0.0 1 75 .67736 .02560 .0000246 .0000 0.0

Cable42 PM-5503A Ind. Motor 1.0NCUN3 2.5 147.6 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable115 PM-5503B Ind. Motor 1.0NCUN3 10 301.8 0.0 1 75 .67736 .02560 .0000246 .0000 0.0

Cable60 PM-5505 Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable92 PM-5601A Ind. Motor 1.0MCUN3 120 98.4 0.0 1 75 .05698 .02225 .0000457 .0000 0.0

Cable63 PM-5801A Ind. Motor 1.0NCUN3 35 301.8 0.0 1 75 .19449 .02438 .0000309 .0000 0.0

Cable94 PM-5801B Ind. Motor 1.0NCUN3 35 262.5 0.0 1 75 .19449 .02438 .0000309 .0000 0.0

Cable13 PM-5801C Ind. Motor 1.0NCUN3 35 301.8 0.0 1 75 .19449 .02438 .0000309 .0000 0.0

Cable12 PM-5902A Ind. Motor 1.0NCUN3 2.5 147.6 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable112 PM-5902B Ind. Motor 1.0NCUN3 2.5 147.6 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable64 PM-5904A Ind. Motor 1.0NCUN3 2.5 213.3 0.0 1 75 2.74431 .03018 .0000149 .0000 0.0

Cable74 WA-8701,2 &8703 Ind. Motor 1.0MCUN4 35 206.7 0.0 1 75 .19449 .02438 .0000309 .0000 0.0

Cable70 WB-8701 Ind. Motor 1.0MCUN4 35 206.7 0.0 1 75 .19449 .02438 .0000309 .0000 0.0
Project: J6A ETAP Page: 9

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

VFD Input Data

AC Rating
MVA V FLA Input Operating Output
Bypass
ID Output Input Output Input Output % EFF % PF V/Hz % Frequency Hz % Imax Switch

VFD1 0.090 400.00 400.00 129.90 129.90 100.00 100.00 100.00 100.0 50.0 150.0 No
VFD3 0.090 400.00 400.00 129.90 129.90 100.00 100.00 100.00 100.0 50.0 150.0 No
Project: J6A ETAP Page: 10

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

LOAD FLOW REPORT

Bus Voltage Generation Load Load Flow XFMR


ID V % Mag. Ang. MW Mvar MW Mvar ID MW Mvar Amp %PF %Tap

* Bus1 400 100.000 0.0 1.172 0.515 0.000 0.000 CP-EN-7201 1.172 0.515 1847.2 91.6

Bus2 400 99.630 -0.1 0.000 0.000 0.001 0.000 CP-EN-7201 -0.001 0.000 0.9 80.0

Bus3 400 99.538 -0.1 0.000 0.000 0.009 0.006 CP-EN-7201 -0.009 -0.006 15.6 80.0

Bus4 400 99.623 -0.1 0.000 0.000 0.001 0.001 CP-EN-7201 -0.001 -0.001 1.7 80.0

Bus6 400 99.376 -0.2 0.000 0.000 0.084 0.000 CP-EN-7201 -0.084 0.000 121.7 100.0

Bus7 400 99.435 -0.1 0.000 0.000 0.097 0.041 CP-EN-7201 -0.097 -0.041 152.5 92.1

Bus8 400 99.401 -0.1 0.000 0.000 0.003 0.003 CP-EN-7301 -0.003 -0.003 6.3 80.0

Bus9 400 99.482 -0.2 0.000 0.000 0.000 0.000 CP-EN-7301 0.000 0.000 0.6 73.9

Bus10 400 99.597 -0.1 0.000 0.000 0.002 0.000 CP-EN-7201 -0.002 0.000 3.2 100.0

Bus11 400 99.618 -0.1 0.000 0.000 0.001 0.000 CP-EN-7201 -0.001 0.000 1.3 100.0

CP-E-7305 400 99.483 -0.2 0.000 0.000 0.000 0.000 CP-EN-7304 0.000 0.000 0.0 0.0

CP-EL-7501 400 99.470 -0.2 0.000 0.000 0.001 0.001 CP-EN-7301 -0.001 -0.001 2.0 80.0

CP-EL-7504 400 99.634 -0.1 0.000 0.000 0.012 0.007 CP-EN-7201 -0.012 -0.007 19.7 85.4

CP-EL-7509 400 99.483 -0.2 0.000 0.000 0.000 0.000 CP-EN-7301 0.000 0.000 0.0 0.0

CP-EL-7801 400 99.459 -0.2 0.000 0.000 0.005 0.004 CP-EN-7301 -0.005 -0.004 9.0 80.0

CP-EL-7803-1 400 99.634 -0.1 0.000 0.000 0.001 0.001 CP-EN-7201 -0.001 -0.001 1.8 78.2

CP-EL-7804 400 99.478 -0.2 0.000 0.000 0.004 0.003 CP-EN-7301 -0.004 -0.003 6.4 80.0

CP-EN-7000 400 99.592 -0.1 0.000 0.000 0.000 0.000 CP-EN-7201 -0.063 -0.032 102.3 89.0

CT-EN-7220 0.063 0.032 102.3 89.0

CP-EN-7201 400 99.634 -0.1 0.000 0.000 0.572 0.242 CP-EN-7301 0.327 0.180 540.1 87.6

Bus7 0.097 0.041 152.5 92.1

Bus1 -1.169 -0.510 1847.2 91.6

Bus6 0.084 0.000 121.7 100.0

Bus2 0.001 0.000 0.9 80.1

Bus10 0.002 0.000 3.2 100.0

CP-EN-7000 0.063 0.032 102.3 89.0

Bus3 0.009 0.006 15.6 80.0

Bus4 0.001 0.001 1.7 80.1

Bus11 0.001 0.000 1.3 100.0

CP-EL-7504 0.012 0.007 19.7 85.4

CP-EL-7803-1 0.001 0.001 1.8 78.2


Project: J6A ETAP Page: 11

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Bus Voltage Generation Load Load Flow XFMR


ID V % Mag. Ang. MW Mvar MW Mvar ID MW Mvar Amp %PF %Tap

VFD1 0.089 0.000 129.5 100.0

VFD3 0.027 0.000 39.2 100.0

CP-EN-7202 400 99.253 -0.2 0.000 0.000 0.054 0.030 CP-EN-7301 -0.054 -0.030 90.6 87.4

CP-EN-7301 400 99.483 -0.2 0.000 0.000 0.242 0.129 CP-EN-7201 -0.326 -0.179 540.1 87.6

Bus8 0.003 0.003 6.3 80.0

CP-EN-7202 0.055 0.030 90.6 87.5

CT-EN-7302 0.009 0.004 14.0 89.6

EL-7506 0.008 0.006 13.7 80.0

CP-EL-7501 0.001 0.001 2.0 80.0

CP-EL-7804 0.004 0.003 6.4 80.0

Bus9 0.000 0.000 0.6 74.0

CP-EN-7304 0.000 0.000 0.0 0.0

CP-EL-7801 0.005 0.004 9.0 80.0

CP-EL-7509 0.000 0.000 0.0 0.0

CP-EN-7304 400 99.483 -0.2 0.000 0.000 0.000 0.000 CP-EN-7301 0.000 0.000 0.0 0.0

CP-E-7305 0.000 0.000 0.0 0.0

CT-EL-7510 400 99.322 -0.2 0.000 0.000 0.002 0.001 CT-EN-7220 -0.002 -0.001 3.0 81.6

CT-EL-7511 400 99.247 -0.1 0.000 0.000 0.001 0.000 CT-EN-7302 -0.001 0.000 1.6 94.4

CT-EL-7512 400 99.322 -0.2 0.000 0.000 0.000 0.000 CT-EN-7220 0.000 0.000 0.0 0.0

CT-EL-7805 400 99.322 -0.2 0.000 0.000 0.004 0.000 CT-EN-7220 -0.004 0.000 6.5 100.0

CT-EN-7220 400 99.322 -0.2 0.000 0.000 0.057 0.031 CP-EN-7000 -0.063 -0.032 102.3 89.1

CT-EL-7805 0.004 0.000 6.5 100.0

CT-EL-7510 0.002 0.001 3.0 81.6

CT-EL-7512 0.000 0.000 0.0 0.0

CT-EN-7302 400 99.247 -0.1 0.000 0.000 0.008 0.004 CP-EN-7301 -0.009 -0.004 14.0 89.5

CT-EL-7511 0.001 0.000 1.6 94.4

EL-7506 400 99.446 -0.2 0.000 0.000 0.008 0.006 CP-EN-7301 -0.008 -0.006 13.7 80.0

* VFD1 400 100.000 0.0 0.089 0.056 0.000 0.000 PM-3201A~ 0.089 0.056 152.4 84.6

* VFD3 400 100.000 0.0 0.027 0.014 0.000 0.000 PM-3201B~ 0.027 0.014 44.2 88.3
* Indicates a voltage regulated bus ( voltage controlled or swing type machine connected to it)
# Indicates a bus with a load mismatch of more than 0.1 MVA
Project: J6A ETAP Page: 12

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Bus Loading Summary Report

Directly Connected Load Total Bus Load

Bus Constant kVA Constant Z Constant I Generic


Percent
ID V Rated Amp MW Mvar MW Mvar MW Mvar MW Mvar MVA % PF Amp Loading

Bus1 400.00 1.280 91.6 1847.2


Bus2 400.00 0.000 0.000 0.000 - 0.001 80.0 0.9
Bus3 400.00 0.007 0.005 0.002 0.001 0.011 80.0 15.6
Bus4 400.00 0.001 0.001 0.000 - 0.001 80.0 1.7
Bus6 400.00 0.067 0.017 0.084 100.0 121.7
Bus7 400.00 0.097 0.041 0.105 92.1 152.5
Bus8 400.00 0.003 0.002 0.001 0.001 0.004 80.0 6.3
Bus9 400.00 0.000 0.000 0.000 - 0.000 73.9 0.6
Bus10 400.00 0.002 0.002 100.0 3.2
Bus11 400.00 0.001 0.001 100.0 1.3
CP-E-7305 400.00
CP-EL-7501 400.00 0.001 0.001 0.000 - 0.001 80.0 2.0
CP-EL-7504 400.00 63.0 0.012 0.007 0.014 85.4 19.7 31.2
CP-EL-7509 400.00 45.0
CP-EL-7801 400.00 125.0 0.005 0.004 0.006 80.0 9.0 7.2
CP-EL-7803-1 400.00 125.0 0.001 0.001 0.001 78.2 1.8 1.4
CP-EL-7804 400.00 125.0 0.004 0.003 0.004 80.0 6.4 5.1
CP-EN-7000 400.00 6000.0 0.071 89.0 102.3 1.7
CP-EN-7201 400.00 3500.0 0.549 0.240 0.002 0.001 0.021 1.275 91.6 1847.1 52.8
CP-EN-7202 400.00 750.0 0.054 0.030 0.062 87.4 90.6 12.1
CP-EN-7301 400.00 1500.0 0.240 0.127 0.002 0.002 0.372 87.6 540.1 36.0
CP-EN-7304 400.00 -
CT-EL-7510 400.00 250.0 0.002 0.001 0.002 81.6 3.0 1.2
CT-EL-7511 400.00 0.001 0.000 0.000 - 0.001 94.4 1.6
CT-EL-7512 400.00
CT-EL-7805 400.00 0.004 0.001 0.004 100.0 6.5
CT-EN-7220 400.00 1250.0 0.057 0.031 0.070 89.1 102.3 8.2
CT-EN-7302 400.00 1150.0 0.007 0.004 0.001 - 0.010 89.5 14.0 1.2
EL-7506 400.00 125.0 0.008 0.006 0.009 80.0 13.7 10.9

* Indicates operating load of a bus exceeds the bus critical limit ( 100.0% of the Continuous Ampere rating).
# Indicates operating load of a bus exceeds the bus marginal limit (95.0% of the Continuous Ampere rating).
Project: J6A ETAP Page: 13

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Branch Loading Summary Report

Transformer
CKT / Branch Busway / Cable & Reactor
Loading (input) Loading (output)
Ampacity Loading Capability
ID Type (Amp) Amp % (MVA) MVA % MVA %

Cable1 Cable 1777.80 540.07 30.38

Cable3 Cable 56.23 6.30 11.20

Cable4 Cable 205.79 152.49 74.10

Cable6 Cable 2370.40 1847.25 77.93

Cable7 Cable 269.35 121.70 45.18

Cable9 Cable 166.39 0.91 0.55

Cable14 Cable 235.00 90.59 38.55

Cable15 Cable 90.85 3.22 3.54

Cable16 Cable 128.85 13.96 10.83

Cable17 Cable 90.85 13.67 15.05

Cable18 Cable 90.85 2.04 2.25

Cable19 Cable 205.79 6.42 3.12

Cable20 Cable 1777.80 102.32 5.76

Cable21 Cable 931.18 102.32 10.99

Cable22 Cable 319.13 15.63 4.90

Cable24 Cable 319.13 1.74 0.54

Cable25 Cable 166.39 0.59 0.35

Cable28 Cable 1185.20 0.00 0.00

Cable29 Cable 90.85 1.35 1.48

Cable30 Cable 1185.20 0.00 0.00

Cable35 Cable 90.85 9.00 9.91

* Indicates a branch with operating load exceeding the branch capability.


Project: J6A ETAP Page: 14

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Branch Losses Summary Report

Vd
From-To Bus Flow To-From Bus Flow Losses % Bus Voltage
% Drop

Branch ID MW Mvar MW Mvar kW kvar From To in Vmag

Cable1 0.327 0.180 -0.326 -0.179 0.4 0.5 99.6 99.5 0.15

Cable14 -0.054 -0.030 0.055 0.030 0.1 0.1 99.3 99.5 0.23

Cable15 -0.002 0.000 0.002 0.000 0.0 0.0 99.6 99.6 0.04

Cable16 0.009 0.004 -0.009 -0.004 0.0 0.0 99.5 99.2 0.24

Cable17 0.008 0.006 -0.008 -0.006 0.0 0.0 99.5 99.4 0.04

Cable18 -0.001 -0.001 0.001 0.001 0.0 0.0 99.5 99.5 0.01

Cable19 -0.004 -0.003 0.004 0.003 0.0 0.0 99.5 99.5 0.01

Cable20 -0.063 -0.032 0.063 0.032 0.0 0.0 99.6 99.6 0.04

Cable21 0.063 0.032 -0.063 -0.032 0.2 0.1 99.6 99.3 0.27

Cable22 -0.009 -0.006 0.009 0.006 0.0 0.0 99.5 99.6 0.10

Cable24 -0.001 -0.001 0.001 0.001 0.0 0.0 99.6 99.6 0.01

Cable25 0.000 0.000 0.000 0.000 0.0 0.0 99.5 99.5 0.00

Cable28 0.000 0.000 0.000 0.000 0.0 0.0 99.5 99.5 0.00

Cable29 -0.001 0.000 0.001 0.000 0.0 0.0 99.6 99.6 0.02

Cable3 -0.003 -0.003 0.003 0.003 0.0 0.0 99.4 99.5 0.08

Cable30 0.000 0.000 0.000 0.000 0.0 0.0 99.5 99.5 0.00

Cable35 -0.005 -0.004 0.005 0.004 0.0 0.0 99.5 99.5 0.02

Cable4 -0.097 -0.041 0.097 0.041 0.2 0.1 99.4 99.6 0.20

Cable6 1.172 0.515 -1.169 -0.510 3.1 4.6 100.0 99.6 0.37

Cable7 -0.084 0.000 0.084 0.000 0.2 0.1 99.4 99.6 0.26

Cable9 -0.001 0.000 0.001 0.000 0.0 0.0 99.6 99.6 0.00

4.2 5.5

* This Transmission Line includes Series Capacitor.


Project: J6A ETAP Page: 15

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Equipment Cable and Overload Heater Losses Summary Report

% Voltage

Connected Load Cable /Overload Heater Losses


Terminal on % Vst
% Vd
ID Type ID Library kW kvar Bus Bus kV Load kV Operating Starting

PM-5001 Ind. Motor Cable68 1.0MCUN4 0.3 0.1 99.43 99.17 99.17 0.26 95.15

PM-5301 Ind. Motor Cable5 1.0NCUN3 0.0 0.0 99.63 99.58 99.58 0.05 97.93

PM-5302 Ind. Motor Cable8 1.0NCUN3 0.0 0.0 99.63 99.62 99.62 0.02 97.74

PM-5303A Ind. Motor Cable10 1.0NCUN3 0.0 0.0 99.63 99.54 99.54 0.09 94.48

83P003A Ind. Motor P-1172 1.0NCUN3 0.0 0.0 99.63 99.48 99.48 0.16 96.47

PM-5902A Ind. Motor Cable12 1.0NCUN3 0.0 0.0 99.63 99.60 99.60 0.03 98.62

PM-5801C Ind. Motor Cable13 1.0NCUN3 0.0 0.0 99.63 99.37 99.37 0.26 90.30

83-PM-005A Ind. Motor Cable38 1.0NCUN3 0.0 0.0 99.63 99.30 99.30 0.33 93.95

83P001A Ind. Motor Cable39 1.0NCUN3 0.0 0.0 99.63 99.55 99.55 0.08 93.99

83P002A Ind. Motor Cable40 1.0NCUN3 0.0 0.0 99.63 99.39 99.39 0.24 88.16

PM-5303B Ind. Motor Cable41 1.0NCUN3 0.0 0.0 99.63 99.41 99.41 0.23 95.56

PM-5503A Ind. Motor Cable42 1.0NCUN3 0.1 0.0 99.63 98.48 98.48 1.15 84.51

PM-5306 Ind. Motor Cable44 1.0NCUN3 0.0 0.0 99.63 99.55 99.55 0.08 97.69

PM-5304A Ind. Motor Cable46 1.0NCUN3 0.1 0.0 99.63 98.31 98.31 1.33 91.81

PM-3203A Ind. Motor Cable47 1.0NCUN3 0.0 0.0 99.63 99.49 99.49 0.14 98.83

PM-3201A Ind. Motor Cable49 1.0NCUN3 0.5 0.3 100.00 99.45 99.45 0.55 97.14

30-MOV-001 Ind. Motor Cable117 1.0NCUN3 0.0 0.0 99.63 99.53 99.53 0.10 97.39

PM-5505 Ind. Motor Cable60 1.0NCUN3 0.0 0.0 99.63 99.33 99.33 0.30 93.99

PM-3302A Ind. Motor Cable61 1.0NCUN3 0.2 0.0 99.63 98.80 98.80 0.84 96.00

PM-3303A Ind. Motor Cable62 1.0NCUN3 0.0 0.0 99.63 99.18 99.18 0.46 95.92

PM-5801A Ind. Motor Cable63 1.0NCUN3 1.9 0.2 99.63 97.22 97.22 2.41 90.63

PM-5904A Ind. Motor Cable64 1.0NCUN3 0.0 0.0 99.63 99.59 99.59 0.05 98.18

LM-5601 Ind. Motor Cable69 1.0NCUN3 0.0 0.0 99.63 99.60 99.60 0.04 98.81

LM-5601B Ind. Motor Cable71 1.0NCUN3 0.0 0.0 99.63 99.60 99.60 0.04 99.20

PM-5308 Ind. Motor Cable79 1.0NCUN3 0.1 0.0 99.63 98.68 98.68 0.95 87.98

CP-EK-5401 Ind. Motor Cable81 1.0NCUN3 0.0 0.0 99.63 99.16 99.16 0.47 96.65

PM-5307 Ind. Motor Cable83 1.0NCUN3 0.0 0.0 99.63 98.68 98.68 0.95 93.99

KM-6101C Ind. Motor Cable101 1.0NCUN3 0.1 0.0 99.63 99.27 99.27 0.36 95.34

PM-5304B Ind. Motor Cable93 1.0NCUN3 0.0 0.0 99.63 99.47 99.47 0.17 90.05

PM-5801B Ind. Motor Cable94 1.0NCUN3 0.0 0.0 99.63 99.37 99.37 0.27 90.28

PM-3303B Ind. Motor Cable97 1.0NCUN3 0.0 0.0 99.63 99.52 99.52 0.12 93.42

83-PM-005B Ind. Motor Cable109 1.0NCUN3 0.0 0.0 99.63 99.41 99.41 0.22 89.61

83P001B Ind. Motor Cable110 1.0NCUN3 0.0 0.0 99.63 99.39 99.39 0.24 95.26

83P002B Ind. Motor Cable111 1.0NCUN3 0.0 0.0 99.63 99.47 99.47 0.16 91.95

83P003B Ind. Motor P-2 1.0NCUN3 0.0 0.0 99.63 99.45 99.45 0.19 96.47
Project: J6A ETAP Page: 16

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Equipment Cable and Overload Heater Losses Summary Report

% Voltage

Connected Load Cable /Overload Heater Losses


Terminal on % Vst
% Vd
ID Type ID Library kW kvar Bus Bus kV Load kV Operating Starting

PM-5902B Ind. Motor Cable112 1.0NCUN3 0.0 0.0 99.63 99.59 99.59 0.04 98.62

PM-3203B Ind. Motor Cable113 1.0NCUN3 0.0 0.0 99.63 99.29 99.29 0.34 87.16

PM-5503B Ind. Motor Cable115 1.0NCUN3 0.5 0.0 99.63 97.55 97.55 2.08 90.33

PM-3201B Ind. Motor Cable116 1.0NCUN3 0.1 0.0 100.00 99.81 99.81 0.19 96.58

PM-5305 Ind. Motor Cable120 1.0NCUN3 0.0 0.0 99.63 99.55 99.55 0.08 95.26

PM-5601A Ind. Motor Cable92 1.0MCUN3 2.1 0.8 99.63 98.72 98.72 0.92 95.00

WB-8701 Ind. Motor Cable70 1.0MCUN4 0.1 0.0 99.25 98.81 98.81 0.45 93.22

WA-8701,2 &8703 Ind. Motor Cable74 1.0MCUN4 0.1 0.0 99.25 98.87 98.87 0.38 92.95

BM-7001C-1 Ind. Motor Cable33 1.0MCUN3 0.2 0.0 99.48 99.04 99.04 0.44 97.43

KM-6101A Ind. Motor Cable77 1.0MCUN3 0.3 0.0 99.48 98.80 98.80 0.69 96.46

AM-7001A Ind. Motor Cable80 1.0MCUN3 0.3 0.0 99.48 98.88 98.88 0.61 96.69

KM-6101B Ind. Motor Cable73 1.0MCUN3 0.0 0.0 99.48 99.35 99.35 0.13 94.67

CT-KT-3101 Ind. Motor Cable23 1.0MCUN3 0.0 0.0 99.32 99.26 99.26 0.06 96.72
Project: J6A ETAP Page: 17

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

Alert Summary Report

% Alert Settings
Critical Marginal
Loading
Bus 100.0 95.0

Cable / Busway 100.0 95.0

Reactor 100.0 95.0

Line 100.0 95.0

Transformer 100.0 95.0

Panel 100.0 95.0

Protective Device 100.0 95.0

Generator 101.0 95.0

Inverter/Charger 100.0 95.0

Bus Voltage
OverVoltage 105.0 102.0

UnderVoltage 95.0 98.0

Generator Excitation
OverExcited (Q Max.) 105.0 95.0

UnderExcited (Q Min.) 100.0

Critical Report

Device ID Type Condition Rating/Limit Unit Operating % Operating Phase Type

Cable63 Cable Overload 78.387 Amp 103.871 132.5 3-Phase

Cable92 Cable Overload 214.127 Amp 353.547 165.1 3-Phase

CB (32A)-7 LV CB Overload 32.000 Amp 57.106 178.5 3-Phase

CP-G-7001D Generator Under Power 1.580 MW 1.172 0.0 3-Phase

Marginal Report

Device ID Type Condition Rating/Limit Unit Operating % Operating Phase Type

VFD1 VFD Overload 129.904 Amp 129.495 99.7 3-Phase


Project: J6A ETAP Page: 18

Location: 19.5.0C Date: 01-07-2020

Contract: SN: SSMENGINER

Engineer: Kishok babu Ganesan Revision: Base


Study Case: LF
Filename: J6A_Turbine_Gen_Rev-1 Config.: Normal

SUMMARY OF TOTAL GENERATION , LOADING & DEMAND

MW Mvar MVA % PF

Source (Swing Buses): 1.172 0.515 1.280 91.55 Lagging

Source (Non-Swing Buses): 0.000 0.000 0.000

Total Demand: 1.172 0.515 1.280 91.55 Lagging

Total Motor Load: 1.101 0.561 1.236 89.08 Lagging

Total Static Load: 0.043 0.019 0.047 91.71 Lagging

Total Constant I Load: 0.000 0.000 0.000

Total Generic Load: 0.024 0.000 0.024 100.00 Lagging

Apparent Losses: 0.004 -0.065

System Mismatch: 0.000 0.000

Number of Iterations: 1