Está en la página 1de 4
@aunane ReJItLA LINEAL SISTEMA CONTINUO (SC) L-BG GUIA DE SELECCION Tabla # 1. Desempefio del aire de suministro entre 0° y 15° de Desviacién ARCO! Vk 500 700 900 1000 1100 1200 1300 (pulgadas) Pt O16 031 051 062 075 090,105 te Ps 012 024 «040 050 060072 .08t NC - 6 0 2B 26 20 3 112 [Flow. _-CFM/Ft 31] 4 | 56] 63 | 69 ] 75 | 81 Throw. Vertical | 6-9 / 9-13 10 - 44/41 - 16/13 - 18/13 - 19/14 -20 062 |Ft. Horizontal [8 - 11 |11 - 16|13 - 18] 14 - 20]15 - 22/47 -24|17 -25, 2 Flow. -CFM/Ft 43 | 6 | 77 | 86 | 94 | 102) 111 Throw. Vertical | 5-8 | 8-12 |10 - 14|11 - 16]13 - 18/13 - 19/14 -20 2086 |Ft. Horizontal |7 - 10 |10 - 15/13 - 18] 14 - 20,15 -22| 17 24| 17-25 212 |Flow. -CFM/Ft 55 | 7 | 99 | 110 | 121 | 132 | 143 Throw. Vertical | 6-9 / 9-13 /11 -16|13 - 18/13 - 19] 15 21/15 -22 110 (Fe. Horizontal | 8-14 |11 . 16] 14.2016 - 23] 17. 24] 18 . 26|20 .28 3 Flow. -CFM/Ft 5 | ot | 117 | 130 | 143 | 155 | 169 Throw. Vertical |7 - 40 10 - 14/13 - 16|44 - 20/15 - 21|45 -22/17 -24 .130__|Ft.___-Horizontal | 8 - 12 |13 - 18|15 - 22|17 - 25] 18 - 26] 20 28 |21 -30 312 Flow. -CFM/Ft 76 | 17 | 137 | 153 | 168 | 183 | 198 Throw. Vertical |7 - 10/10 - 15/13 - 18|15 - 21]15 - 22/17 -24|18 -26 .152__|Ft. ___-Horizontal | 9 - 13 |13 - 19|16 - 23] 18 - 26|20 - 28/21 -30|22 -32 4 Flow. -CFM/Ft ee | 123 | 158 | 175 | 193 | 210 | 228 Throw. Vertical |8 - 11/13 - 18/14 - 20|16 - 23]18 - 26/19 -27|20 -29 .176__|Ft.___-Horizontal |10 - 14|45 - 22|17 - 25|20 - 29|22 - 32|24 -34|25 -36 5 Flow. -crM/Ft | 140 | 154 | 198 | 220 | 242 | 264 | 285 Throw. Vertical |8 - 12/13 - 18/15 - 21] 47 - 24|18 - 26/19 -27|21 -30 200 _|Ft. ___-Horizontal |10 - 15|15 - 22|18 - 26|21 - 30|22 - 32|24 -34|26 -37. 6 Flow. -CFM/Ft | 133 | 186 | 239 | 265 | 292 | 318 | 349 Throw. Vertical |8 - 12/13 - 18/15 - 22|17 - 25]18 - 26|20 -28|21 -30 265 _|Ft. Horizontal | 10 -15|15 - 22|19 - 27|22 - 31|23 - 33| 24 35 |27 -38 8 Flow. -crM/Ft | 178 | 249 | 320 | 355 | 391 Throw. Vertical [10 - 14] 13 - 19|15 - 22) 18 - 26|19 - 271 .356__|Ft. Horizontal |12 - 17|17 -24|20 - 28|23 - 33|24 - 34 10 Flow. -cFM/Ft | 223 | 312 | 401 | 445 Throw. Vertical [10 - 15/15 - 22/18 - 26/21 - 30 M40__|Ft. __-Horizontal |13 - 19|20 -28|23 - 33|26 - 37| 2 Flow. -CFw/Ft | 268 | 375 | 482 Throw. Vertical |12 - 17/22 - 31[21 - 30} 530 |Ft. Horizontal [15 - 21|24 - 35[27 - 38| REJILLA LINEAL SISTEMA CONTINUO (SC] L-BG GUIA DE SELECCION Tabla # 2. Desempefio del aire de suministro a 30° de Desviacién ANCHO Vk 570 805 «10351140 1265 «1380 1495 (pulgadas) Pt 020 040 067 081 100,119,139 aa Ps O17 034,056 070 084) ,100 118 NC - 20 6 8 3 3 36 112 Flow. -CFM/Ft 36] 50] 65 | 71 | 79 | 8 | OF Throw. Vertical | 6 -9 | 9-43 |10 - 44/11 - 16/13 - 18/43 - 19/14 -20 063 Ft. Horizontal |8 - 1111 - 16|13 - 18|14 - 20/15 - 22|47 -24|17 -25 2 Flow. -CFM/Ft 48 | 68 | 88 | 97 | 108 | 117 | 127 Throw. 8-12 |10 - 14/11 - 16/13 - 18/43 - 19/14 -20 084 [Ft 10 -15|13 - 18|14 - 20/15 - 22|47 -24|17 -25 212 |Flow. -CFM/Ft 63 | 89 | 114 | 125 | 139 | 152 | 164 Throw. Vertical | 6 -9 | 9 - 43 |11 - 16/13 - 18/13 - 19|45 -21/15 -22 110 [Ft Horizontal |8 - 1111. 16|14 - 20|16 -23] 17 - 24|18 -26|20 -28 3 Flow. -CFM/Ft 74 | 105 | 135 [ 148 [| 164 | 179 | 194 Throw. Vertical |7 - 1010 - 14|13 - 18/14 - 20] 15 21 |45 -22/17 -24 1130 [Ft Horizontal |8 - 12 |13 - 18|15 - 22|17 -25|18 -26|20 -28|21 -30 312 |Flow. -CFM/Ft a7 | 123 | 156 | 174 | 193 | 211 | 228 Throw. Vertical |7 - 10/10 - 15]13 - 18]15 -21) 15 22 |17 -24/18 -26 1153 [Ft Horizontal |9 - 13 | 13 -19 | 16 23|18 -26|20 - 28|21 -30|22 -32 4 Flow. -CFM/Ft too | 141 | 181 | 200 | 221 | 242 | 262 Throw. Vertical |8 - 1113 - 18/14 - 20/16 - 23/18 -26|19 -27|20 -29 175__|Ft. Horizontal |10 - 14] 15 - 22|17 - 25|20 -29|22 - 32|24 -34|25 -36 5 Flow. -CFM/Ft 125 | 177 | 228 | 251 | 278 | 304 | 329 Throw. 13 - 18/15 -21]17 - 24] 18 -26|19 -27|21 -30 Ft. 15 - 22|18 - 26|21 - 30|22 - 32|24 -34|26 -37 Flow. -CFM/Ft tor | 213 | 274 | 302 | 335 | 366 | 396 Throw. Vertical |8 - 12|13 - 18|15 - 22|17 -25] 18 -26|20 -28[21 -30 Ft. Horizontal [10 - 15] 15 - 22|19 -27|22 - 31|23 -33|24 -35| 27 38 Flow. -CFM/Ft | 202 | 286 | 367 | 405 | 449 Throw. Vertical |10 - 14] 13 - 19|15 - 22/18 - 26/19 -27 2354 [Ft Horizontal |12 - 17] 17 - 24|20 - 28|23 - 33/24 - 34 10 Flow. -CFM/Ft | 254 | 358 | 461 | 507 Throw. Vertical |10 - 15] 15 - 22|18 - 26|21 - 30 446 [Ft Horizontal |13 - 19]20 - 28|23 - 33|26 - 37, 2 Flow. -CFM/Ft | 305 | 431 | 554 Throw. Vertical |12 - 17|22 - 31[21 - 30] 535__|Ft. Horizontal |15 -21]24 - 35[27 - 38| REJILLA LINEAL SISTEMA CONTINUO (SC} L-BG GUIA DE SELECCION Tabla # 3. Desempefio del aire de retomo entre 0° y 15° de Desviacién NC ancho [AkArea|10__15 20252831355 Efectiva PS (pulgadas)/""|02 030406 BMS CFM. POR PIE LINEAL 112 13 20 25 30 35 40 45 50 55 2 18 30 40 45 55 65 70 80 90 2172 23 45 55 60 75 85 95 105 115 3 2 55. 70 80 90 110 125 135, 150 3172 30 65 80 90 110 125 140 155 170 4 34 80/ 100 110 130 150 170 185 205 5 4 100) 125 140 175_| 200 | 225 245 275 6 46/120) 150 175 | 215 | 245 | 275 305 340 8 57 |165| 200 235 | 290 | 330 | 380 10 68 (215) 260 315 | 375 | 430 | 495 12 76 (|265|_ 325 375 | 455 | 525 Tabla # 4. Desempefio del aire de retomo a 30° de Desviacion NC AkAreal10 15 20,2528 3135S Efectiva| PS 02 03 tS CFM. POR PIE LINEAL ANCHO 112 2 |e, 2 | % | 30 | 35 | 40 | 50 | 55 2 aw |25|_25 | 35 | 40 | 48 | 63 | ve | o8 212 z_[35[ 45 | 50 | 60 | 7o | 80 | 100 | 110 3 25 [45 55 | 65 | 75 | 90 | 100 | 130 | 145 312 29 _[50[ 65 | 75 | 90 | 105 | 120 | 150 | 165 4 33__[eo[ 75 | 90 | 110 | 125 | 140 | 175 [| 200 5 39 _[so[ 100 | 120 | 140 | 160 | 180 | 225 | 255 6 44 _[100[_ 120 [140 [170 | 200 | 220 | 280 [315 8 4 [135 165 | 200 | 240 | 270 [ 300 | 380 10 64 [175215 [250 | 300 | 350 [390 | 500 2 72__|eto[ 260 | 300 | 380 | 425 [ 475 (Own REJILLA LINEAL SISTEMA CONTINUO (SC) L-BG GUIA DE SELECCION NOTAS Y SiMBOLOS THROW = La distancia total { en pies} cubierta por la cortiente de aire, antes de que su velocidad maxima caiga en un nivel terminal preseleccionado (V1) de 10 FPM (pies/minuto) y 50 FPM respectivamente. NC= Criterio de ruido. La tabal # 1 esta basada en la atenuacién en el cuarto 0 salén de 10 d8(decibeles), referida re: 10 vatios. Ps = Presién estatica en pulgadias de agua. Ak = Area efectiva en pies cuadrados de rejilla activa por pie lineal. Flow = El volumen de aire por pie de rejilla en pies cUbicos por minuto. V¥k= Velocidad de salida en pies por minuto. V¥r= Velocidad del cuarto | medida en zona ecupadal en pies por minuto. Vis Velocidad terminal en pies por minuto. Pi= Presion total en pulgadas de agua. NG - Criterio de ruido. Las tablas 2,3 y 4 estan basadas en la atenuacién en cuarto 0 salén de 10 dB { decibels) referida re: 10 -1avatios. CFM - Volumen de aire en pies cbicos por minuto. Otros simbolos igual a la tabla # 1

También podría gustarte