The document provides information on Cutler-Hammer 1600A NW Moulded Case Circuit Breakers. It lists key features such as meeting IEC 60947-2 standards, having a high 70kA interrupting capacity rating at 415V AC, and using Digitrip RMS 310 electronic trip units. It also provides specifications on adjustable long time pickup, compact design that takes up 46% less panel space, and a complete line of external accessories. Dimensions and catalog numbers are given for 3-pole and 4-pole options.
The document provides information on Cutler-Hammer 1600A NW Moulded Case Circuit Breakers. It lists key features such as meeting IEC 60947-2 standards, having a high 70kA interrupting capacity rating at 415V AC, and using Digitrip RMS 310 electronic trip units. It also provides specifications on adjustable long time pickup, compact design that takes up 46% less panel space, and a complete line of external accessories. Dimensions and catalog numbers are given for 3-pole and 4-pole options.
The document provides information on Cutler-Hammer 1600A NW Moulded Case Circuit Breakers. It lists key features such as meeting IEC 60947-2 standards, having a high 70kA interrupting capacity rating at 415V AC, and using Digitrip RMS 310 electronic trip units. It also provides specifications on adjustable long time pickup, compact design that takes up 46% less panel space, and a complete line of external accessories. Dimensions and catalog numbers are given for 3-pole and 4-pole options.
V AC 50/60 Hz kA rms Icu/Ics Meets IEC 60947-2 Standards NW HNW KEMA KEUR Third Party Certified 220-240 85/85 100/100 380-415 50/50 70/50 High Performance 70 kA I.C. Rating @ 415 V Ac 660-690 20/10 25/13
Digitrip RMS 310 Electronic Trip Unit Digitrip RMS 310
LS L - Adjustable Long Delay Pickup 50-100% In LSI S – Adjustable Short Delay Pickup w/ Fixed Short Delay 2 LSG Time 2-8 x In (I t Response) or Adjustable Short Delay LSIG Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Adjustable Long Time Pickup Delay Time to Instantaneous 0-300 ms 800, 1000, 1250, 1600 G – Adjustable Ground Fault Pickup 200-1200 A with Adjustable Ground Fault Delay (Flat Response) 0-500 ms Compact Design Catalog Number 46% Less Panel Space Than R-Frame MCCB Standard I.C. High I.C. Trip Unit 210 mm Wide x 406 mm High x 345 mm Depth 3-Pole
Field Installed Accessories NW316T33WP35 HNW316T33WP35 LS
Auxiliary Switch NW316T32WP35 HNW316T32WP35 LSI Alarm Switch NW316T35WP35 HNW316T35WP35 LSG Shunt Trip (Variety of Voltage Ratings) NW316T36WP35 HNW316T36WP35 LSIG UVR (Variety of Voltage Ratings) 4-Pole
Complete Line of External Accessories NW416T33WP35 HNW416T33WP35 LS