Está en la página 1de 28

IP-20G Overview

July 2015
Version 4
Agenda

• FibeAir IP-20 Product Family

• Network topology with IP-20G

• IP-20G Introduction and Highlights

• IP-20G Front Panel Description

• IP-20G Block Diagram

2 Proprietary and Confidential


FibeAir IP-20 Product Family

IP-20G

IP-20N 1RU & 2RU

IP-20E
IP-20S

IP-20GX IP-20C

IP-20
Platform

IP-20A= IP20N + RFU-A


Available only for US & NA market
IP-20LH

3 Proprietary and Confidential


FibeAir IP-10 Product Line - 2011
Ethernet + Optional TDM Ethernet Only

IP-10G IP-10E IP-10C

Compact
All-Outdoor
Terminal / Terminal /
Single-Carrier Single-Carrier

IP-10Q
Aggregation
Nodal Nodal

Optimized for “Full GE”


Multi-Carrier pipes
Ultra-high density

Optimized Solution for Any Network


4 Proprietary and Confidential
FibeAir IP-X0 Product Line - 2012 (Introducing IP-20G)
Ethernet + Optional TDM Ethernet Only

IP-10G IP-10E IP-10C

Compact
All-Outdoor
Terminal / Terminal /
Single-Carrier Single-Carrier

IP-20G IP-10Q
Aggregation

Optimized for “Full GE”


Multi-Carrier pipes
Ultra-high density

Optimized Solution for Any Network


5 Proprietary and Confidential
Network Topology Example (Tree)

C C

1+1 1+0

C C
IP-20N
C
C
2+0
1+1

C
IP-20N
C
C IP-20N
1+0 C C
C
1+0
2+0
C
2+0 1+0
IP-10G C C

IP-20N
IP-20G
C C
IP-20G IP-10G

6 Proprietary and Confidential


IP-20G Introduction
IP-20G hardware characteristics:

• 6 x 1 GE interfaces total
• 2 x dual mode GE electrical or cascading interfaces (RJ-45)
• 2 x GE electrical interfaces (RJ-45)
• 2x GE optical interfaces (SFP)
• Optional: 16 x E1 interfaces
• Single or dual radio interfaces (TNC)
• Single or dual power-feeds (-48v)
• Sync in/out interface
• Management interfaces
• Terminal – RS232 (RJ-45)
• 2x FE electrical interfaces (RJ-45)
• External alarms interface
• RFU-C/Ce, RFU-HP (1Rx or 2Rx), RFU-Ae/Aep support
• IEEE-1588 TC

• IP-20G maintains high capacity, with up to 1024QAM modulation in its first SW release (T7.7),
and up to 2048QAM from SW release T8.0

7 Proprietary and Confidential


IP-20G Highlights
• Optimized tail/edge solution supporting seamless integration of radio (L1)
and end-to-end Carrier Ethernet transport/services (L2) functionality
• Rich packet processing feature set for support of engineered end-to-end
Carrier Ethernet services with strict SLA
• Integrated support for multi-operator and converged backhaul business
models, such as wholesale services and RAN-sharing
• Highest capacity, scalability and spectral efficiency
• High precision, flexible packet synchronization solution combining SyncE
and 1588v2
• Best-in-class integrated TDM migration solution
• Specifically built to support resilient and adaptive multi-carrier radio links,
scaling to GE capacity
• Future-proof with maximal investment protection
• Supports RFU-Ce for modulations up to 2048QAM.

8 Proprietary and Confidential


Reference Configurations

9
IP-20G Dual Modem Activation
• A single-carrier IP-20G unit with dual-modem hardware can be converted via
software upgrade to a dual-modem unit

10 Proprietary and Confidential


IP-20G IDU Cascading with Dual Modems
• A dual-modem IP-20G in an East-West configuration, with a cascading link to a pair
of IP-20G units
• A cascading connection between these two units enables hybrid Ethernet/TDM traffic
to pass among all three units

11 Proprietary and Confidential


IP-20G Chained Network

12 Proprietary and Confidential


IP-20G Ring with Spur
• A ring consisting of three IP-20G nodes connected via 1+0 radio links, with a spur to
a fourth IP-20G node
• All of the IP-20G units in the ring utilize dual-modem configurations, except for the
node at the bottom in the figure

13 Proprietary and Confidential


IP-20G Aggregation/POP Site

14 Proprietary and Confidential


IP-20G Front Panel Description

15
FibeAir IP-20G – Front panel description

Passive cooling
(Fan-less design)

1RU

Power
16 x E1/DS1s External
1 or 2 RFU -48V DC
(optional) Alarms 2 x FE
2 x GE interfaces (Single-feed &
MDR69 connector (DB9) Management via
Optical (TNC) Dual-feed options)
splitter cable 2 x Dual-Mode: (SFP)
(RJ45) GE Electrical or
Sync in/out
‘Cascading’
(RJ45)
Terminal (RJ45) 2 x GE
(RJ45) Electrical
(RJ45)

Purpose-built for tail/edge nodal sites


Same features/capabilities as IP-20N/A Aggregation Nodes

16 Proprietary and Confidential


SM- Card
• The SM-Card holds the configuration and software for the IDU. The SM-
Card is embedded in the SM-Card Cover, so re-using the existing SM-Card
Cover is necessary to ensure that the unit’s software and configuration is
maintained.
• Contains only software with configuration

17 Proprietary and Confidential


Ethernet Management Interface IP-20G
• FibeAir IP-20G contains two FE management interfaces, which connect to a single RJ-45 physical
connector on the front panel (MGMT).

• If the user only needs to use a single management interface, a standard Cat5 RJ-45 cable (straight or
cross) can be connected to the MGMT interface.
• To access both management interfaces, a special 2 x FE splitter cable can be ordered from Ceragon.

• Port Status LED – The LED for management interface 1 is located on the upper left of the MGMT
interface. The LED for management interface 2 is located on the upper right of the MGMT interface.

18 Proprietary and Confidential


E1/DS1 - Interface
• Optionally, FibeAir IP-20G can be ordered with an MDR69 connector in which 16
E1/DS1 interfaces are available (ports 1 through 16).
• In SW 7.7. is E1 option only available
• In SW 7.9. also DS1 option available
• The E1/DS1 interface has the following LEDs
• ACT LED – Indicates whether the TDM card is working properly (Green) or if there is
an error or a problem with the card’s functionality (Red).
• E1/DS1 LED – Indicates whether the interfaces are enabled with no alarms (Green),
with alarms (Red), or no interfaces enabled (Off).

19 Proprietary and Confidential


Radio Interfaces
• In 7.7 is supported only single radio carrier.
• In 7.7.5 is supported 2x 1+0 East / West Terminal
• In 7.9 is supported 2+0 XPIC
• In 7.7 is supported only RFU-C (up to 256QAM) and RFU-Ce (up to 1024
QAM)
• In 7.9 RFU-HP, 1500HP, RFU-A supported
• In 8.0 release is supported 2+0 ABC
• The IDU and RFU are connected by a coaxial cable RG-223 (100 m/300 ft),
Belden 9914/RG-8 (300 m/1000 ft) or equivalent, with an N-type connector
(male) on the RFU and a TNC connector on the IDU.

RFU-C / RFU-Ce RFU-HP / 1500HP RFU-A

20 Proprietary and Confidential


Radio Interfaces - LEDs

• ACT – Indicates whether the interface is working properly (Green) or if there is


an error or a problem with the interface’s functionality (Red), as follows:
• Off – The radio is disabled.
• Green – The radio is active and operating normally.
• Blinking Green – The radio is operating normally and is in standby mode.
• Red – There is a hardware failure.
• Blinking Red – Troubleshooting mode.
• LINK – Indicates the status of the radio link, as follows:
• Green – The radio link is operational.
• Red – There is an LOF or Excessive BER alarm on the radio.
• Blinking Green – An IF loopback is activated, and the result is OK.
• Blinking Red – An IF loopback is activated, and the result is Failed.
• RFU – Indicates the status of the RFU, as follows:
• Green – The RFU is functioning normally.
• Yellow – A minor RFU alarm or a warning is present, or the RFU is in TX
mute mode, or, in a protected configuration, the RFU is in standby mode.
• Red – A cable is disconnected, or a major or critical RFU alarm is present.
• Blinking Green – An RF loopback has been activated, and the result is OK.
• Blinking Red – An RF loopback has been activated, and the result is
Failed.

21 Proprietary and Confidential


Power Interfaces

• FibeAir IP-20G receives an external supply of -48V current via one or two power
interfaces (the second power interface is optional for power redundancy).

• The IP-20G monitors the power supply for under-voltage and includes reverse
polarity protection, so that if the positive (+) and negative (-) inputs are mixed up, the
system remains shut down.

• The allowed power input range for the IP-20G is -40V to -60V. An under voltage
alarm is triggered if the power goes below the allowed range, and an over voltage
alarm is triggered if the power goes above the allowed range.

• There is an ACT LED for each power interface.


• The LED is Green when the voltage being fed to the power interface is within range,
and Red if the voltage is not within range or if a power cable is not connected.

22 Proprietary and Confidential


Synchronization Interface
• FibeAir IP-20G includes an RJ-45 synchronization interface for T3 clock input and T4 clock output.
The interface is labeled SYNC.

• The synchronization interface contains two LEDs, one on the upper left of the interface and one
on the upper right of the interface, as follows:

• T3 Status LED – Located on the upper left of the interface. Indicates the status of T3 input clock,
as follows:
• Off – There is no T3 input clock, or the input is illegal.
• Green – There is legal T3 input clock.

• T4 Status LED – Located on the upper right of the interface. Indicates the status of T4 output
clock, as follows:
• Off – T4 output clock is not available.
• Green – T4 output clock is available.
• Blinking Green – The clock unit is in a holdover state.

23 Proprietary and Confidential


External Alarms
• IP-20G includes a DB9 dry contact external alarms interface. The external alarms
interface supports five input alarms and a single output alarm.

• The input alarms are configurable according to:


• 1 Intermediate
• 2 Critical
• 3 Major
• 4 Minor
• 5 Warning

• The output alarm is configured according to predefined categories.

24 Proprietary and Confidential


Terminal Interface
• FibeAir IP-20G includes an RJ-45 terminal interface (RS-232). A local craft
terminal can be connected to the terminal interface for local CLI
management of the unit.

• Bits per Second – 115,200


• Data Bits – 8
• Parity – None
• Stop Bits – 1
• Flow Control - None

25 Proprietary and Confidential


IP-20G Block Diagram
Sync

48V
Radio Interface 1
Power
48V Supply Framer Modem IF
RFU
Interface RFU
(Optional Dual
Feed)

ABC/BBS XPIC

PPS 1588 OC/BC


RFU
ToO (Optional) Framer Modem IF
Interface RFU

Sync

Radio Interface 2
Sync
In/Out Sync Unit (Optional)

FE Management
Interfaces
CPU
Terminal

Ethernet
Ethernet Services
TDM Interfaces
GE Traffic
Interfaces
(Optional)
Network
Processor TDM
16 x E1
TDM Pseudowire Services Services Framer LIU
Interface
Processor

GE/Cascading Services
Interfaces
Engine

TDM Cross
Connect

Native TDM
Services

26 Proprietary and Confidential


Unique Feature Set
ACM 4-2048QAM
Extended Modulations Range
(11 ACM points)

Frequency bands 6-42GHz

10, 20, 30, 40, 50, 60MHz (FCC)


Wide range of channels
7, 14, 28, 40, 56MHz (ETSI)
1+0

2x 1+0 EW

System Configurations 1+1 HSB

2+0 XPIC

2+0 ABC
Traffic Aware “Smart Pipe”
Traffic Manager
Multi Service, Carrier Ethernet 2.0 Switch

Radio Connection RFU-C, RFU-Ce, 1500HP, RFU-HP, RFU-A

27 Proprietary and Confidential


Thank You