Está en la página 1de 1

MARK NO. GRID LOCATION ERECTION ITEM UNIT WT. WT./ITEM TOTAL WT.

DESCRIPTION WIDTH LENGTH GRADE QTY. REMARKS


MARK NO. IN Kgs IN Kgs IN Kgs
1VB-2 5-6/C' 4.620
A-13 L100X100X10 2551 ASTM-A36 2 15.10 38.52 77.04
P-273 20 THK. PLT. 100 120 ASTM-A36 2 7.85 1.88 3.77
1VB-2 x 1 TOTAL = 80.81 KGS

BOLT LIST FOR ASSEMBLY MKD' 1VB-2


DIA. BOLT GRADE LENGTH QTY.
24 8.8 80 8

2551
2351
2431
2511
40

200
280

2271
0

120
40 80 80 1991 80 80 80
80 40
A
P-273 100

TYP
P-273 TYP

10
4*D26 A-13 A-13 4*D26

TYP
120
60

60
28.4

A
542 900 1109
0

542

1442

2551
3132

466 2551 115 REFERENCE DRAWING:


KSS021-D-1393

A-13 NOTES :-
1) ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS ARE IN METERS.
2) ALL BOLT HOLES SHALL BE Ø 22 FOR M20 BOLTS (U.N.O.)
20

20
3) ALL WELDS SHALL BE 6mm CONTINUOUS FILLET WELD (U.N.O.)
4) DENOTES SHOP MARK SHALL BE PROVIDED BY THE FABRICATOR ON
A-13 FLANGE OF MEMEBER/FACE OF PLATES ON EACH ASSEMBLY AS SHOWN,
ON SHOP DETAIL DRAWINGS SAME IS TO BE REFFERD FOR ORIENTATION,
DURING ERECTION OF THE ASSEMBLY.

P-273
100

P-273
A-13
0 12-01-2014 ISSUED FOR FABRICATION RBS SAJ SAJ
TYP REV DATE DESCRIPTION DRN CHK APP'D

A-13 PROJECT:
120 PROPOSED FLUIDIZED BED DRYER FOR PVC PLANT
AT TCI SANMAR , EGYPT
A-A
CLIENT:
KILBURN ENGINEERING LTD.
PLOT NO. 6 MIDC - SARAVALI KALYAN BHIWANDI ROAD, KALYAN,
DIST. THANE, MAHARASHTRA 421311 INDIA

STRUCTURAL CONSULTANT:

AXIS CONSULTANTS
107, Bldg. NO.2, Sec-3, Millennium
Business Park, Mahape, Navi Mumbai-400710
Phone-022 27780733.
www.axisconsultants.co.in

PROJECT No.: 193


SCALE
BUILDING DESC. : FLUIDIZED BED DRAYER FOR PVC PLANT
1:10
Tekla structures

1 No. VER BRACING REQUIRED AS DRAWN MKD' -1VB-2 DRAWING TITLE :


FABRICATION DRAWING OF DRAWING NO. REV.

VER BRACING 1VB-2 KSS021-D-623 0