Está en la página 1de 5
1811012017 ‘Surge Protection Solutions for Water and Wastewater Systems. [BERMAD SUBSIDIARIES © ‘OUR BLOGS ~ | ABOUT US | LANGUAGE ¥ Bu Water Control Solutions ee = Protection Solutions for Water and Wastewater Systems Posted by Tal Levi on Oct 17, 2017 8:51:00 AM [stare] © (tke 3) [Stare] + Whether caused by pump start-up, shut-off, valve closure or unanticipated event such as abrupt Surge Protection power failure which leads to pumps trip, Solutions unintended pressure surges can develop and wreak havoc on a water system. BERMAD offers a package of services and products to prevent water hammer damage to pipes, valves, and any other hydraulic components in potable water, sea water, and wastewater systems. Surge Analysis For large systems, it is crucial to perform surge analysis to determine the correct size and type of surge protection devices, which must to be included in the system design. BERMAD application engineers use surge analysis software to ensure optimal and safe operation and better surge protection during all stages of system operation. This includes: « KYPipe Surge software - a leading surge software which provides BERMAD customers with precise engineering calculations to evaluate the pressure surge magnitude and supports finding the optional cost-effective surge solution, * BERMAD AIR -Software for precise air valve sizing & positioning to optimize air control in water and wastewater pipelines and networks. Combination Air Valve with Surge Protection hitpbiog.bermadcomwaterworksisurge-protection-solutons-wastewater-systoms?utm._campaign=WW_Surge%20Protection%420Solutions%20/0r%... 15 18102017 ‘Surge Protection Solutions for Water and Wastewater Systems. This feature partially closes the valve's orifice in response to a pressure surge, helping to decelerate the approaching water column and prevent damage to the valve and system. Surge Anticipating Control Valves The abrupt stopping of a pump is usually associated with pressure drops and a subsequent surge as the traveling column of water travels back towards the pump. Typical wave celerity can reach 400-1,200 m/sec , which is too fast for a standard relief valve to react, BERMAD's offline hydraulic surge anticipating control valve remains closed during regular operation of the system. However, when it senses a drop in line pressure it immediately opens to dissipate the returning pressure wave and eliminate the surge. It is doing so by relieving excessive in line pressure. This highly reliable valve is in-line serviceable for easy maintenance. And because it is line pressure driven and does not require a motor, itis suitable for use in difficult to maintain or remote areas and older systems. Bladder Surge Tank Pressure surges in systems with long runs of pipe can quickly cause pipe ruptures and other damage. Installing a Bladder Surge Tank provides a shock absorbing effect that protects the system and its components from both positive and negative system surges. BERMAD's Bladder Surge Tank is a steel tank containing a flexible bladder which constitutes a physical barrier between the water and the air. Compressed air at a pressure compatible with system requirements is confined between the tank housing and the bladder. The trapped air creates active and effective air volume which expend, allowing free flow to the mainline and by that preventing vacuum conditions on negative surge. On the other hand, it compresses and absorbs excessive energy on positive surge. The internal bladder precludes the dissolution of the air into the water, so no need using a compressor which recovers continually the discharge pressure. Thereby almost no maintenance and no electricity is required under normal operation. Pump Control Valve ‘Active check pump control valves are double chambered, hydraulically operated valves that open fully or shut off in response to electric signals. The pump isolates from the system during Itp:togbermaecomvaterworkssurgeprotecton-solione- waster systams?utn_campaign=WW_Surge%20Protectonts20Solsions42010%... 25 18102017 ‘Surge Protection Solutions for Water and Wastewater Systems. pipeline surges. Our surge analysis services help our customers achieve enhanced system efficiency and superior protection against water hammer, and can reduce costs and prolonging system lifespan. For more information on surge protection for your water or wastewater system, or to inquire about our surge analysis services, contact us here to locate a BERMAD representative in your region, cnsaman WELCOME TO|BERMAD CITY aca Mtoe Topics: Waterworks: Written by Tal Levi First Name* Last Name Email* Website hitpbiogbermadcomwaterworksisurgo-protection-solutions-wastewater-systoms?utm,_campaign=WW_Surge%20Protection%420Sokutions%20/0r%... 35 1811012017 ‘Surge Protection Solutions for Water and Wastewater Systems. \dupscripe to rollow-up comments ror tnis post SUBMIT COMMENT Subscribe to BERMAD Waterworks Blog Email* SUBSCRIBE Recent Posts © Surge Protection Solutions for Water and Wastewater m: The Evolution of Water Metering - Impact on Water Use & Utility Revenue © Visit BERMAD at WEFTEC 2017 in Chicago - Featuring Magnetic Flow Meter: * Announcing the New BERMAD Website and Waterworks Blog Posts by Topic Waterworks (4) x hitpbiog.bermadcomwaterworksisurge-protection-solutons-wastewater-systoms?utm_campaign=WW_Surge%20Protocton*é20Solutlons%20For%, 465 1811012017 ‘Surge Protection Solutions for Water and Wastewater Systems. PRODUCTS OUR PROJECTS DOWNLOADS STANDARDS & APPROVALS, irrigation irrigation irrigation global landscape landscape building constructions building constructions building constructions building constructions waterworks waterworks waterworks waterworks fire protection fire protection fire protection fire protection INSPIRATIONS BERMAD VIDEO “UFE IS A DIALOG" RAW Development hitpbiog.bermad.comwaterworksisurge-protection-solutons-wastewater-systoms?utm_campaign=WW_Surge%20Protocton*é20Solutons%20For%, 515

También podría gustarte