Está en la página 1de 3

AlphaSeal PU25VLS NG

74109
New Generation Single Component Polyurethane based elastomeric adhesive sealant |
High strength bonding and sealing

Bulletin Technique
Product Description
AlphaSeal PU25VLS NG is new generation single component polyurethane based
elastomeric adhesive sealant which cures under the effect of atmospheric humidity to form
a high elasticity joint that has a good resistance to tear and to weather.

Areas of Applications
AlphaSeal PU25VLS NG can be used for bonding various construction materials and as
sealing joint. specially adapted for bonding various building and for expansion joints,
panel joints in Precast Construction. This sealant adheres without primer on substrates
commonly used, like wood, anodized aluminum, polyester, glass, concrete, baked clay,
stone, ceramic tiles. For difficult materials, including plastics such as PVC, ABS, PMMA, or
materials such as raw aluminum or lacquered metal, perform preliminary tests to
determine whether a surface preparation is necessary

Characteristics / Advantages
▪ One-component, ready to use
▪ Good adhesion to many substrates
▪ Low modulus
▪ ±50% joint movement
▪ Excellent workability, easy to smooth
▪ Can be overpainted / sanded
▪ Excellent durability
▪ Non-staining
▪ Made in France

Technical Data

Appearance Pasty
Color Various
Density at 20°C Black : 1.15 ± 0.02 - Others : 1.16 ± 0.02
Sagging (ISO 7390) < 3 mm
Application temperature 5 to 35°C
Skin formation time at 23 °C and 50%
5 to 10 h
HR
Cure time at 23 °C and 50 % HR 2 mm/ 24 h
Shore A hardness (internal method) 20
Approx 25
after ISO 868 - 3 seconds)
Version 2018/1, Page 1/3

Modulus at 100 % (ISO 8339) ≤ 0,4 MPa


Elongation at break (ISO 8339) > 400 %
Temperature resistance -40 to +80°C
Resistance to dilute acids and bases Average
UV resistance Good
On cured sealant:
Compatibility - Water based paints: yes
with paints - Solvent based paints: carry out test
beforehand
Weatherability : good
Tear strength (ISO 34) : approx. 6.5 N/mm
Classification according to ISO 11600 standard : Class F –
25LM – M1up*, Aup*
* up : means without primer

Classification according to ASTM C-920 standard: Type S,


Specific data
Grade NS, Classes 25 and 50, uses NT, T, A and M
Doesn't stain the marble or granite stone (tests according to
ASTM C-1248-93 standard)

Dimensional stability according to NF-EN 10563 standard : ≥ -


10%

CONSUMPTION

300 ml cartridge

Tube (mm) 2 3 4 5 6 7 8 9 10
Length of cord (m) 95 42 24 15 10,5 7,5 5,5 4,5 3,5

600 ml sausage

Tube (mm) 2 3 4 5 6 7 8 9 10
Length of cord (m) 190 85 47 30 21 15 11 9 7

PACKAGING
300 ml cartridges and 600 ml sausages Contact us for other packaging options.

SAFETY
Read the material safety data sheet before use.

INSTRUCTIONS FOR USE


The substrates must be clean, even, dry, free of dust, oil, grease and any
contaminants that could harm bonding. They may be cleaned with
methylethylketone (MEK), acetone or grease remover.
Version 2018/1, Page 2/3

Apply a primer if necessary. Check the compatibility of the solvent used with the
substrates. When using solvents, extinguish all sources of ignition and carefully follow
the safety and handling instructions given by the manufacturer or supplier. If
necessary, rub down metal surfaces beforehand. After rubbing down, the surface
should be recleaned. Allow the substrate to dry after degreasing.
We recommend to clean concrete with a metal brush.
Caulking :
AlphaSeal PU25 VLS NG can be applied by a manual or pneumatic gun. After
application, use a putty knife to smooth the joint with soapy water. This product should
be used within 24 hours of opening the cartridge or sausage ; otherwise, the sealant
could harden inside. Do not apply at a temperature under 5 °C. In cold weather, store
the cartridges at about 20 °C before use.
Avoid any contact with non-cured MS, hybrid PU or silicone sealants as well as with
alcohols or ammonia during curing.

Cleaning :
Tools should be cleaned with MEK or acetone before the sealant has completely
cured. After curing, abrasion is necessary.

Shelf life 12 months in closed original packaging stored in dry premises at a


temperature lower than 25 ºC. In cold weather store the cartridges
at about 20 ºC before use.

Recommended Proper handling and care should be taken during transportation


Storage, dispatch process to prevent from rain and sunshine. The product should
be stored in ventilated and dry place and avoid storage with
other chemicals.

Value Base All technical data stated in this Data Sheet are based on
laboratory tests. Actual measured data may vary due to
circumstances beyond our control.

Health & Safety For information and advice on the safe handling, storage and
disposal of chemical products, users should refer to the most
recent Material Safety Data Sheet containing physical,
ecological, toxicological and other safety-related data.

Disclaimer The information and recommendations relating to the application


and end-use of Alpha range of applied products, are given in
good faith based on ROne International’s current knowledge and
experience of the products when properly stored, handled and
applied under normal conditions in accordance
recommendations. In practice, the differences in materials,
substrates and actual site conditions are such that no warranty in
respect of merchantability or of fitness for a particular purpose,
nor any liability arising out of any legal relationship whatsoever,
can be inferred either from this information, or from any written
recommendations, or from any other advice offered. The user of
Version 2018/1, Page 3/3

the product must test the product’s suitability for the intended
application and purpose. ROne International reserves the right to
change the properties of its products.

ROne International, Ocean Plaza, 503, Sector 18, Noida – 201301 (Uttar Pradesh), India,
Contact us @ Phone +91 120 4316626, Email: info.roneinternational@gmail.com