Está en la página 1de 38

User Manual

1.0 General Guide


Thank you for purchasing your new ADC.
We recommend reading this manual, and WARNING !
practicing the operations before using your
ADC in the field. ! Make sure that you fully understand the
functions and limitations of the ADC
before relying on it.
The ADC is designed to provide you with ! The ADC is an assisting device for the
information essential to your needs. Data outdoor user, and is not a substitute for
such as temperature, wind speed, barometric weather advisories from a weather
pressure, altitude and humidity are features station. It is helpful to check the
specific to four different ADC models: Wind, readings provided by this product
Summit, Pro and JetSet. periodically with those broadcasted by
the weather station.

Each ADC model is constructed to withstand


water submersion and is ideal for conditions
you endure during outdoor activities such as
hiking, climbing, hunting, kayaking, skiing,
and racing. Every ADC also includes current
time, daily alarm, chronograph and race
timer functions. ADCs are equipped with a
propeller and other precise sensors to
measure outdoor conditions.
2.0 Care and Maintenance
Prevent getting dirt in the ADC propeller. It
could clog the mechanism.

Avoid exposing this product to extreme heat


or extreme cold for an unreasonable amount
of time.

Avoid severe impacts to the ADC.

Store the ADC in a dry place when it is not in


use.

Clean the ADC with a soft moistened cloth


occasionally.

DO NOT expose the ADC to strong


chemicals such as gasoline and alcohol, as
they will damage this product.
3.0 Part description

Red-colored
blade

1st row
2nd row
3rd row
4nd row Propeller
Propeller blade
Display

[mode]

[light]

Detachable [set] Push Button [reset]


Belt Clip
4.0 Button Operation Summary 1
[mode] Button
Press the mode button to select among the
[mode] major function modes
In function modes: Press and hold the mode
button to select setting display
In any setting display: Press the mode button to
select among different settings. Press and
hold the mode button to exit setting sequence.

[set] Button
[set]
In Current Time Mode: press the set button to
select the Daily Alarm Display.
In Daily Alarm Mode: Press the set button to
switch the daily alarm between ON and OFF.
Note: In Chronograph Mode and Race Timer Mode:
The button operations are Press the set button to start or stop the
summarized in the following counting.
paragraphs, for detail operating In Lap Time Recall Mode: Press the set button
instructions, please continue to select the available lap time(s).
reading. In setting displays: press the set button to scroll
the through the settings.
4.1 Button Operation Summary 2
[reset] Button
In Chronograph Mode (counting): Press the
reset button to get Lap Time Display.
In Chronograph Mode (stop-counting): Press
the reset button to reset the display to zero.
In Timer Mode (stop-counting): Press the
[light]
reset button to reset the timer to target time.
In Lap Time Recall Mode: Press the reset
button to select the available lap time(s).
In setting displays: press the reset button to
[reset] scroll the through the settings.

[light] Button
In any functional mode/display, press the light
Note: button once to turn ON the EL backlight for
The button operations are about 3 seconds.
summarized in the following
paragraphs, for detail operating
instructions, please continue
reading.
5.0 Major Functional Modes

WIND Km/H [mode] THU 06-MAR [set] DAILY ALARM [mode] CHRONO
2003 ON GRAPH
21.3 12:38 28 12:00 0:00.00
18.3 8.3 28.0 8 C 00

Wind Mode Current Time Mode Daily Alarm Mode Chronograph Mode

[mode] [mode]

TEMP 8C RACE TIMER


[mode] [mode]
28.3 0:10.00
18.2 13.2

Temperature Mode Race Timer Mode

Sensor Function Time Function

Major Functional Modes


6.0 Current Time Mode - Functional Displays

Day of week
Date
THU 06MAR Year
2003
Current
Time 12:38.28
28.0 C Current
Temperature

Current Time Mode


6.1 Current Time Mode - Setting the Current Time Mode
To Select Setting Display
! Setting the current time and date, and their
06MAR reset Second to zero display formats, press and hold the [mode]
THU button for about 2 seconds to select the
12:38.28 setting display (the '12' indicator will start
88.2% 28.0 8 C '12' changes to '24'; flashing).
'24' changes to '12'.

Current Time Mode [set] [set] The Setting Sequence


or [reset] or [reset]
hold hold
! In setting display, press the [mode] button to
[mode]
[mode] [mode] move the setting following the adjacent
12/24 second diagram.
[reset] ! When the ' 12 ' or ' 24 ' digits starts flash,
scroll through [mode]
the settings by [mode] press the [set] or [reset] button to switch
increment between ' 12 ' (12 hour format) and ' 24 ' (24
hour minute
hold [reset] hour format). When the ' second ' digits starts
scroll flash on the display, press [set] or [reset]
the setting at [mode] button to reset the second to zero.
a faster pace
[mode]
! If one of the settings (minute, hour, year,
[set] year month month, date) starts flash, press the [set] or
scroll through [reset] button to scroll through the setting
the settings by [mode]
decrement (hold down the button to scroll the setting at
hold [set] [mode] a faster pace).
scroll
the setting at
date
! When the above settings finished, press and
a faster pace hold the [mode] button for about 2 seconds
to exit the setting sequence.
Current Time Setting Sequence
7.0 Daily Alarm Mode - Daily Alarm Display
Daily Alarm Display
Mode indicator
! In Daily Alarm Mode, the display will show
DAILY ALARM the following:
ON Alarm ON/OFF
12:00 Status 1) The mode indicator ' DAILY ALARM' appears
on the 1st row of the display.
Alarm time
2) The ' ON ' or ' OFF ' status indicator appears
Alarm ON Alarm ON Display on the 2nd row of the display.
Indicator
3) The alarm time (hour and minute) appears
[set] on the 3rd row of the display.
To Select Daily Alarm between ON and OFF
DAILY ALARM ! To select the daily alarm between ON and
OFF OFF, press the [set] button once.
--
-- :: -- ! When the daily alarm is ON, the Alarm ON
Indicator ' ' appear otherwise it is OFF.
Alarm OFF Display Daily Alarm Sound
! When the daily alarm is ON, the product will
Daily Alarm Mode beep at the predefined alarm time for about
30 seconds.
! When the beep sounds, it can be stopped
prematurely by pressing any of the buttons
except the [light] button.
7.1 Daily Alarm Mode - Setting the Daily Alarm Mode
To Select the Setting Display
! Setting the Daily Alarm Time, press and
hold the [mode] button for about 2 seconds
DAILY ALARM scroll the scroll
to select the setting display (the 'minute'
ON setting by the setting
increment of 1 faster digits will start flashing).
12:00
[reset] hold
[reset]
The Setting Sequence
! In setting display, press the [mode] button to
Daily Alarm Mode move the setting between minute and hour
hold hold [mode]
[mode] [mode] settings.
Minute Hour ! When one of the settings (minute and hour)
digits start to flash on the display, press the [set]
[mode] or [reset] button to scroll through the setting
(hold down the button to scroll the setting at a
Daily Alarm Mode faster pace).
Setting Sequence
! When the setting finished, press and hold the
[mode] button to exit the setting sequence.
[set] hold [set]
! The setting display will change to Current Time
scroll the scroll
Mode automatically if no key-stoke has been
setting by the setting activated for about 1 minute.
decrement of 1 faster
8.0 Chronograph Mode - Chronograph Display
Chronograph Function
Mode Indicator ! The ADC is equipped with a Chronograph
CHRONO Chronograph Mode, it can measure 3 different periods of
GRAPH Time (second) time. They are:
Chronograph
Time (hour) 0:00.00
00
1) Elapsed time,
Chronograph Chronograph Time 2) Accumulative elapsed time
Time (minute) Chronograph Mode (1/100 Second)
(Zero Display) 3) Lap time
Chronograph Display
! In Chronograph Mode, the display will show
0 30 the following:
1. Elapsed time 1) T h e m o d e i n d i c a t o r ' C H R O N O G R A P H '
[set] [set]
appears on the 1st and 2nd row of the
0 10 10 20 display.
2. Accumulative 2) The chronograph time (hours, minutes,
elapsed time [set] [set] [set] [set] seconds) appears on the 3rd row of the
display.
0 10 10 3) The lap number and chronograph time
3. Lap time (1/100 second) appears on 4th row of the
[set] [reset] [reset] display.
0 10 20 30 40 ! The display shows the 'Zero' display, if the
time product or the chronograph has been reset.
! The maximum counting range of the
Elapsed Time, Accumulative Elapsed Time and Lap Time chronograph is 99 hours, 59 minutes and
: Stop Counting : Counting 59.99 seconds. The chronograph can record
up to 50 laps.
8.1 Chronograph Mode - Using the Chronograph
Chronograph Function
Lap Time
(the chronograph CHRONO ! In 'Zero' Display, press the [set] button once
is counting in the
RUNNING to start the counting. When it is counting,
background)
0:00.00 press the [set] button again to stop the
1L 01 counting, and the elapsed time of which the
Lap No. chronograph is counting will appear.
Chronograph Mode
(Lap Time Display) ! When the elapsed time is displaying, repeat
the key operations above to get the
10 seconds [reset] accumulative elapsed time or press the
[reset] button to reset the chronograph.
Check the below 'To Reset the Chronograph'
CHRONO [set] CHRONO
section for more detail on how to reset the
GRAPH RUNNING
0:00.00 0:00.00 chronograph.
00 01 To Record a Lap Time
counting
Chronograph Mode Chronograph Mode
! When the chronograph is counting in the
('Zero' Display) (Counting Display) previous operations, press the [reset] button
Elapsed Time [set]
to display Lap Time Display for 10 seconds.
(the chronograph
is stop counting)
! When the Lap Time is displaying, the
chronograph remains counting in the
[reset] CHRONO background.
STOP
Note: 0:00.00 To Reset the Chronograph
This diagram illustrates the 20 ! To reset the chronograph, to be ready for a
general flow among different new operation, press the [reset] button once
functional displays only, and Chronograph Mode when the chronograph has stopped counting.
may NOT conform to fact in all (Stop Counting Display)
The display will then return to 'Zero' Display.
instances.
8.2 Chronograph Mode - Recall the Lap Time
To Recall the Lap Time
Select the lap time by Select the lap time by
backward scrolling
(fast scrolling)
backward scrolling ! In Stop Counting Display, press and hold
(1 lap per step)
the [mode] button to select the Chronograph
hold [set] [set]
Recall Display.
! In Chronograph Recall Display, the total
elapsed time will appear. To recall the
CHRONO hold CHRONO individual lap time, press the [set] or [reset]
STOP [mode]
RECALL button to select the target lap time (hold
0:00.00 0:02.02 down the button to scroll the setting faster)
20 20 following the adjacent diagram.
Stop Counting Display Lap Time Recall Display ! In Chronograph Recall Display, press and
(Total Time) hold the [mode] button to return to the Stop
hold [reset]
[reset]
Counting Display.
Select the lap time by Select the lap time by Chronograph Recall Display
forward scrolling forward scrolling
(fast scrolling) (1 lap per step) ! In Chronograph Recall Display, the display
will show the following:
1) The mode indicator ' CHRONO RECALL '
[reset] [reset] appears on the 1st and 2nd row of the
CHRONO CHRONO Next display.
RECALL [set] RECALL [set] Available
0:02.02 0:04.02 Lap Time(s) 2) T h e l a p t i m e ( h o u r s , m i n u t e s ,
1L 20 Lap No. 2L 20 seconds) appears on the 3rd row of the
Lap Time display.
Lap Time Recall Display Lap Time Recall Display 3) The lap number and lap time (1/100
(Lap 1 Time) (Lap 2 Time)
second) appears on the 4th row of the display.
9.0 Race Timer Mode - Race Timer Display
The Target Time
Mode
Indicator RACE TIMER ! The ADC is equipped with a countdown timer to
keep track of a fixed period of time (target time).
0:10.00 ! The user can set a target time of up to 99 hours,
Target Time 59 minutes 59 seconds.
(Hour, minute,
second) ! Check the coming 'Setting the Race Timer
Race Timer Mode Mode' section for more detail on how to set the
target time in Racer Timer Mode.
Race Timer Display
30 0 ! In Race Timer Mode, the display will show the
1. Single-phase following:
down [set]
counting beep 1) The mode indicator ' RACE TIMER ' appears
on the 1st row of the display.
30 20 20 0
2. Multi-phases 2) T h e t a r g e t t i m e ( h o u r s , m i n u t e s ,
down [set] [set] [set] seconds) appears on the 3rd row of the
counting beep display.
30 20 30 ! The maximum counting range of the Race
3. Reset to
Timer is 99 hours, 59 minutes and 59
preset [set] [set] [reset] seconds.
target time

0 10 20 30 40
time

Single/multi-down Counting & Reset


: Stop Counting : Counting
9.1 Race Timer Mode - Setting the Race Timer Mode
To Select the Setting Display
! Setting the target time in Race Timer Mode,
RACE TIMER press and hold the [mode] button for about 2
scroll through
scroll the scroll seconds to select the setting display (the
0:10.00 thesetting
increment
by by
settings
of 1
the
thesetting
settingat
fasterpace
second digits will start flashing).
increment a faster
Setting Sequence
hold
[reset]
[reset] ! In setting display, press the [mode] button to
Race Timer Mode move setting following the adjacent diagram.
hold
[mode]
hold [mode] ! When the one of the settings (second, minute,
[mode]
Second Minute
hour) start to flash, press the [set] or [reset]
button to scroll through the settings (hold down
the button to scroll at a faster pace).
[mode] [mode]
! When the setting finished, press and hold the
[mode] button for about 2 seconds to exit the
Hour
setting sequence.
! The setting display will change to Race Timer
Race Timer Mode Mode automatically if no key-stoke has been
Setting Sequence
activated for about 1 minute.
[set] hold
[set]

scroll through
scroll the scroll
thesetting by by
settings the
thesetting
settingat
decrement
decrement of 1 fasterpace
a faster
9.2 Race Timer Mode - Using the Race Timer
To Use the Race Timer
RACE TIMER beeps
RACE TIMER ! Once a target time has been set, press the
STOPPED
[set] button once to start the countdown.
0:10.00 stop
0:00.00 When it is running, press the [set] button
counting again to stop the countdown.
Stop-Counting Display Stop-Counting Display ! The countdown time will be displayed
continuously throughout the operation.
set the 29'59" To Reset the Timer
target
time to ! To reset the timer to the preset target time
30 minute
RACE TIMER RACE TIMER before the countdown reaches zero, press
[set] the [reset] button once when the timer has
RUNNING
0:30.00 0:29.59 been stopped.
counting ! To set a new value for the target time, check
the previous 'Setting the Race Timer Mode'
Stop-Counting Display Counting Display section for more detail on how to set the
Racer Timer Mode.
[set]
[reset]
Race Timer Alarm Sound
stop ! At the last 10 minutes, the Alarm will beep
counting once for every minute.
RACE TIMER
STOP ! At the last 10 seconds, the Alarm will beep
Note: 0:29.59 once for every second.
This diagram illustrates the
general flow among different ! At zero, the Alarm will beep for about 2
functional displays only, and Stop-Counting Display seconds.
may NOT conform to fact in all
instances.
10.0 Wind Speed Mode - Before Using the Wind Speed Mode
the propeller How Wind Speed is Measured
blades are entirely
exposed to air ! The ADC is equipped with a propeller that is
similar to a traditional aerovane.
! When the propeller faces the wind, it
rotates and generates signal. This product
will pick up the signal and converts it into
wind speed.
Before and After Measuring a Wind Speed
Propeller Closed Propeller Opened ! Turn the ball-shape propeller by your thumb
and index finger until the propeller blades
are entirely exposed, and it is not sheltered
wind wind by the case.
! After a wind speed measurement, rotate the
propeller to a closed position to prevent dirt
from getting into it.
display
To Measure Wind Speed
! Select Wind Speed Mode. Point the blades
directly towards the wind direction, and
make sure that the blades rotate freely.
! When the wind passes through the propeller,
the blades rotate. The ADC starts to
measure, and shows the current, average
and maximum wind-speed readings.
Point the Propeller towards the wind direction
10.1 Wind Speed Mode - Wind Speed Mode Function
Wind Speed Mode Functions
Current, Max ! This ADC has the following wind speed
Beaufort and Average functions:
Scale Wind Speed 1) The Beaufort Scale: The longest and
most widely used set of criteria to
describe the wind conditions. Check the
coming ' Beaufort Scale ' section for more
Wind Speed
Wind detail on Beaufort Scale.
Speed
Display Lock
Alarm
2) The Current, Maximum and Average
Average Wind Speed.
3) Wind Speed Alarm: alarm that alerts the
user when the current wind speed is higher
than the predefined level.
Time Span
Setting 4) Wind Speed Display Lock: This feature
can lock the wind speed display for 5
seconds.
5) Time Span Setting: This feature defines
Wind Speed Mode Functions the time for the Average Wind Speed
Calculation. Check the coming ' Time
Span Setting for Average Wind Speed '
section for more detail on the setting.
10.2 Wind Speed Mode - Wind Speed Display
Wind Speed Display
Mode Wind ! In Wind Speed Mode, the display will show
Indicator Speed Unit the following:
Beaufort WIND mph 1) The ' WIND ' Indicator and the wind speed
Scale Current unit appear on the 1st row of the display.
(by average 21.3 Wind Speed
2) T h e B e a u f o r t S c a l e ( c a l c u l a t e d b y
wind speed) 18.3 8.3
average wind speed) appears on the 2nd
Average
Maximum
Wind Speed row of the display.
Wind Speed
Wind Speed Mode 3) The Current Wind Speed appears on the
3rd row of the display.
4) The maximum and average wind speed
[reset] appears on the 4th row of the display.
Km/h mph To Change Wind Speed Unit
! This ADC can display wind speed in the
[reset] following wind speed units:
[reset]
1) Km/h (Kilometer per hour),
2) mph (mile per hour),
m/s feet/s
3) feet/s (feet per second)
4) m/s (meter per second) and
[reset] [reset]
5) Knots.
! In Wind Speed Mode, press the [reset]
Knots button to change the wind speed unit
following the adjacent diagram.
Wind Speed Unit Selection Sequence
10.3 Wind Speed Mode - What is Beaufort Scale?
What is Beaufort Scale?
! Beaufort Scale is the longest and most
widely used set of criteria to describe the
Beaufort WIND mph wind conditions and its effects on land as
Scale well as on sea.
(by average 21.3 Average
wind speed) 18.3 8.3 Wind Speed
! It categorizes the wind speed into 13 force
numbers, from 0 (calm) to 12 (hurricane).
Check the 'Beaufort Scale Table' section
Wind Speed Mode below for more detail on the Beaufort Scale.
Beaufort Scale Bar
Beaufort Scale ! For user's convenience, the ADC displays
(calculated by average wind speed)
Beaufort Scale for average wind speed.
force force force
no. 1 no. 5 no. 10
! T h e A D C e x h i b i ts B e a u f o r t S c a l e b y
displaying different number of bars on the
upper row of the display. One exhibited bar
is equivalent to one Beaufort Scale force
Example A: Number 5 of Beaufort Scale number. For example, if there are 5 bars on
the display, the average wind speed is
Beaufort Scale equivalent to force number 5 of Beaufort
(calculated by average wind speed) Scale.
force force force
no. 1 no. 8 no. 10 ! The ADC displays the Beaufort Scale force
number from 0 to 10 (if the average wind
speed is higher than force number 10, the
ADC will display 10).
Example B: Number 8 of Beaufort Scale
10.4 Wind Speed Mode - Beaufort Scale Table
10.5 Wind Speed Mode - Wind Speed Display Lock, Reset Max Wind Speed
Wind Speed Display Lock
! The ADC is equipped with a function to hold
WIND mph the fluctuating wind speed reading on the
display.
21.3
18.3 8.3 ! In Wind Speed Mode, press the [set] button
to lock the wind speed reading (the display
will hold the current reading for 5 seconds).
Wind Speed Mode
Reset the Maximum Wind Speed
hold
[set] 5 seconds [reset] ! To reset the maximum wind speed, press
and hold the [reset] button for 2 second to
WIND mph RESET MAX select the Reset Display.
hold
lock WIND? NO [mode] ! When the Reset Display is displayed, press
indicator L 21.3 (abort the
the [set] button to select between 'YES' and
18.3 8.3 18.3 8.3 reset)
display
'NO'.
keep still flashing
Wind Speed Mode Maximum Wind Speed ! In the ' YES ' display, press and hold the [mode]
(Display Locked) Reset Display - NO button for 2 about seconds to confirm the
hold
[mode] [set] reset (the maximum wind speed will reset to
(confirm zero).
the
Note: reset) ! To abort the reset, press and hold the [mode]
RESET MAX
This diagram illustrates button for 2 seconds in the ' NO ' display.
the general flow among WIND? YES
different functional
displays only, and may 18.3 8.3
NOT conform to fact in flashing
all instances. Maximum Wind Speed
Reset Display - Yes
10.6 Wind Speed Mode - Wind Speed Alarm
Wind Speed Alarm
Wind Speed
'beep' ! The ADC is equipped with a wind speed
for 5 alarm.
seconds
(every 2 ! That alarm alerts user when the current
Alarm Range minutes) wind speed is equal to or higher than the
preset preset wind speed level.
wind speed
level Wind Speed Alarm Sound
! In Wind Speed Mode, if the Current Wind
Below Alarm Range Speed is equal to or larger than the preset
wind speed level, the ADC will start beeping
for about 5 seconds.
0 Time ! After the first beeping, the ADC will beep
again for every 2 minutes if the current wind
The Wind Speed Alarm Range speed holds above the preset level.
! The above repeated alarm will stop unless
the wind speed again exceeds the preset
level or the wind speed alarm is set to OFF.
10.7 Wind Speed Mode - Setting the Wind Speed Alarm and Time Span
To Set the Wind Speed Alarm, and Time Span
hold Wind Speed Alarm and for Average Wind Speed Calculation
[mode] Time Span Setting Sequence
! To set the wind speed alarm, press and hold
WIND mph [mode]
the [mode] button for about 2 seconds to
Wind Speed Time Span
Setting select the setting display (wind speed starts
21.3 Alarm
flashing).
18.3 8.3
hold
[mode] ! When the 'wind speed' is flashing, press the
Wind Speed Mode [mode] button to select between time span
setting and wind speed alarm setting.
Wind Speed Alarm Setting Time Span
Setting ! When 'wind speed' is flashing, press the
Alarm OFF Alarm ON
[reset] button to scroll the target wind speed
level by 1 step (hold down the button to
WIND mph WIND mph WIND mph scroll the setting faster). To select the wind
[set]
OFF ON
flash AVG PERIOD speed alarm between ON and OFF, press
---- 50.3 10 the [set] button.
18.3 8.3 18.3 8.3 SEC
! When 'time' is flashing, press the [set] or
[reset] button to scroll the target time span
for average wind speed calculation by 1
(hold down the button to scroll the setting
faster).
hold [reset] [reset] hold [reset] [reset]
! Press and hold the [mode] button for about
2 seconds to exit the setting sequence.
scroll scroll through scroll scroll through
thesetting
the settingat
faster
a faster pace
the settings by
increment
the setting at
a faster pace
the settings by
decrement
! The setting display will change to Wind
Mode automatically if no key-stoke has
been activated for about 1 minute.
10.8 Wind Speed Mode - Using the Propeller as a Mechanical Compass
Propeller as a Mechanical Compass
! The ADC measures ambient temperature,
wind speed, and it also tells compass
North East directions.
North Target object ! One of the propeller blades is red-colored to
pole
indicate the magnetic north pole.
! Four reference points were engraved on the
propeller ADC as reference points.
red-colored To use the Mechanical Compass
blade ! To check bearing of an object, make sure
reference that the propeller cover is opened, and the
points blades are entirely exposed to air.
! Tilt the ADC until the propeller blades are
parallel to the horizon, and the propeller
blades rotate freely.
! The red-colored blade of the propeller will
Using the Propeller as a points to the magnetic north pole. Make use
Mechanical Compass of the reference points (marked on the
product) to check the direction of the target
object.
11.0 Temperature - Temperature Functions
Temperature Mode Functions
! The ADC has the following temperature
Current, Minimum functions:
Current Wind Chill
Temperature 1) The Current Temperature: The Current
Temperature
Temperature readings.
2) The Current and Minimum Wind Chill
temperature: The wind effect on
Wind Chill temperature. Check the'WindChill
Temperature Temperature' section below for more detail
Temperature
History Graph on Wind Chill Temperature.
Alarm
3) The Temperature History Graph: The
temperature memory for the last 24 hours.
4) The Wind Chill Temperature Alarm: alarm
Temperature to alert the user when the current Wind
Calibration Chill Temperature is lower than the
predefined limit.
5) The Calibration: The process to calibrate
the temperature reading.
Temperature Mode Functions
11.1 Temperature - Temperature Display
Temperature Display
! In Temperature Mode, the display will show
Mode Temperature
Indicator Unit the following:
TEMP 8C
Current
1) The ' TEMP ' Indicator and the temperature
28.3 Temperature unit appear on the 1st row of the display.
Current Wind Chill
18.2 13.2
Minimum Wind Chill
2) The Current Temperature appears on the
Temperature Temperature 3rd row of the display.
Temperature Mode 3) The Current and Minimum Wind Chill
Temperature appear on the 4th row of the
display.
To Change Temperature Unit
! The ADC can display temperature in the
C following units:
1) Degree Celsius (C)
[reset]
2) Degree Fahrenheit (F)
! In Temperature Mode, press the [reset]
F button once to change the temperature unit.
See adjacent figure.
11.2 Temperature Mode- Wind Chill Temperature
What is Wind Chill Temperature
! Wind chill is a temperature factor that
Wind Current Wind Chill combines air temperature and the effect of
Case Conditions Temperature Temperature Weather blowing wind.
! As blowing wind makes you feel as though
the temperature is lower than simple air
1. NO wind 15F/ -9.4C 15F/ -9.4C Cold temperature.
! For example, if it is -9.4 degrees Celsius
and the wind blows at 80.5 km per hour:
People will feel as if the temperature is -23.3
2. wind speed 15F/ -9.4C -10F/ -23.3C Very degrees Celsius. In this case, the wind chill
at 50 mph/ Cold temperature is -23.3 degrees Celsius.
80.5 km/h
! The ADC is also equipped with wind chill
temperature functions, including displaying
current and minimum wind chill temperature,
3. NO wind -10F/ -23.3C -10F/ -23.3C Very and having a wind chill temperature alarm.
Cold
Note:
Wind Chill Temperature Effects ! Wind chill temperature is the effect that
combines wind speed and temperature, the
ADC must measure the wind speed in order
to display the wind chill temperature.
! Check the previous ' Before Using the Wind
Speed Mode ' section for more detail on
Wind Speed Measurement.
11.3 Temperature Mode - To Reset Minimum Wind Chill Temperature
To R e s e t t h e M i n i m u m W i n d C h i l l
Temperature
TEMP 8C ! To reset the minimum wind chill temperature,
press and hold the [reset] button for 2
28.3 seconds to select the Reset Display.
18.2 13.2
! When the Reset Display is displaying, press
Temperature Mode the [set] button to select between the ' YE S '
and ' NO ' Display.
hold
[reset] ! In the ' YES ' display, press and hold the [mode]
hold button for about 2 seconds to confirm the
RESET MIN [mode] reset (the minimum wind chill temperature
(abort the
W.CHILL? NO reset) will reset to zero).
! To abort the reset, press and hold the [mode]
18.2 13.2 button for 2 seconds in the ' NO ' display.
flashing
Maximum Wind Speed
Reset Display - NO
hold
[mode] [set]
(confirm
the
Note: reset)
This diagram illustrates RESET MIN
the general flow among W.CHILL? YES
different functional
displays only, and may 18.2 13.2
not conform to fact in flashing
all instances. Maximum Wind Speed
Reset Display - Yes
11.4 Temperature Mode - Temperature History Graph for the Last 24 Hours
Temperature History Graph
TEMP 8C ! The ADC is equipped with a temperature
memory function. It records the last 24-hour
28.3 temperature and displays them by bar-graph.
18.2 13.2
! In Temperature Mode, press the [set] button
to select the Temperature History Graph
Temperature Mode Display.
! While in the Temperature History Graph
[mode] [set] Display setting, the right most bar will start
-24 hour 0 hour (current) flashing.
the temperature
TEM flashing bar ! The right most bar represents the current
represents
of the selected 8C the selected record temperature (0 hour). While the other bars
record (numeric) 28.3 (graphical bar) represent the temperature records of the last
current 18.2 1-00 the time that took 24 hours. Each temperature record is taken
wind chill this record at the hour (i.e. 12:00, 1:00, 2:00 ...)
Temperature History Graph Display ! To browse the temperature record at
hold [reset] [reset] hold [set] [set] different times, press the [set] button to
select the record by backward scrolling or
Select the record by Select the record by [reset] button to select time by forward
forward scrolling backward scrolling scrolling (hold down the button to scroll the
(1 hour per step) (1 hour per step)
setting at a faster pace).
! Press the [mode] button once to exit the
Select the lap time by Select the lap time by
forward scrolling backward scrolling Pressure History Graph Display.
(fast scrolling) (fast scrolling)
11.5 Temperature Mode - Wind Chill Temperature Alarm
Wind Chill Temperature Alarm
Wind Chill
Temperature ! The ADC is equipped with a wind chill
temperature alarm.
! That alarm alerts user when the current
wind chill temperature is equal to or lower
High Temperature Range than the preset wind chill temperature level.
Wind Chill Temperature Alarm Sound
'beep'
preset for 5 ! In Temperature Mode: When the Current
wind chill seconds Wind Chill Temperature is equal to or lower
temperature (every 2
level Low Temperature Range than the preset wind chill temperature level,
minutes) the ADC starts beeping for about 5 seconds.
0 Time ! After the first beeping, the ADC will beep
The Wind Chill Temperature Alarm again for every 2 minutes if the current wind
chill temperature holds at or below the preset
value.
! The above repeated alarm will stop unless
the wind chill temperature equals or drops
below the preset value or the wind chill
temperature alarm is set to OFF.
11.6 Temperature Mode - Setting the Wind Chill Temperature Alarm
To Select Setting Display
Wind Chill Temperature Alarm and
hold Temperature Calibration
[mode] Setting Sequence
! To select the setting display, press and hold
the [mode] button for about 2 seconds to
TEMP 8C [mode]
select the setting display (temperature digits
Wind Chill Temperature
Temperature Calibration
will start flashing).
28.3 Alarm
18.2 13.2 The Setting Sequence
hold
[mode] ! When the temperature digits are flashing,
Temperature Mode press the [mode] button to select between
the Wind Chill Temperature Alarm Setting
Wind Chill Temperature Temperature a n d Te m p e r a t u r e C a l i b r a t i o n D i s p l a y
Alarm Setting Calibration Display
Alarm OFF Alarm ON following the adjacent diagram. Check the
'Calibrating the Temperature' section below
W.CHILL 8 C W.CHILL 8 C TEMP 8C for more detail on temperature calibration.
[set]
OFF ON OFFSET ! When the temperature digits are flashing,
---- -10.0 0.0 press the [reset] button to scroll through to
18.3 8.3 18.3 8.3 18.3 8.3
flash
select target wind chill temperature level
(hold down the button to scroll the setting at
a faster pace), or press the [set] button to
select the between wind chill temperature
hold hold
[reset] [reset] [mode] [reset] alarm ON and OFF.
! When the above settings finished, press and
Calibration Setting Display
scroll
scroll the hold the [mode] button for about 2 seconds
setting by
the setting increment Check 'Calibrating to exit the setting sequence.
faster of 1 step the Temperature' section
below for more detail
11.7 Temperature Mode - Calibrating the Temperature
To Select Setting Display
TEMP 8C
! Following the previous ' Setting the Wind
OFFSET
Chill Temperature Alarm ' section to select
0.0 the Calibration Display.
18.3 8.3 ! In the Calibration Display, press and hold
the [reset] button for 2 seconds to select the
Temperature Calibration Display Calibration Setting Display.
The Setting Sequence
[mode] hold [reset]
! When the 'offset value' digits are flashing,
press the [set] or [reset] buttons scroll
TEMP 8C through to select target offset value (hold
OFFSET the offset down the button to scroll the setting at a
value
wind chill 0.0 faster pace).
temperature 18.3 8.3 current ! When the above settings finished, press the
temperature
[mode] button once to exit the setting
Calibration Setting Display sequence.
hold [reset] [reset] hold [set] [set] Note:
Select the Select the
1) When the temperature has been calibrated,
setting by setting by the ADC will offset the current temperature
forward scrolling backward scrolling by the target offset value. For example:
If the offset value is +2 and the current
Select the setting by Select the setting by temperature is 26 degrees C, the ADC will
forward scrolling backward scrolling display 28 degrees C (26+2).
(fast scrolling) (fast scrolling)
2) The current wind chill temperature will be
updated as above accordingly.
12.0 Specifications
Current Time Mode Chronograph Mode
! Hour, minute and second ! Resolution: 1/100 second
! Month, day, day of week and year ! Counting range: 99 hours, 59 minutes, 59.99
! 12 / 24 hour format selectable seconds
! Auto calendar from year 2003 to 2099 ! Measurement: Elapsed time, accumulative
elapsed time and lap time.
Wind Speed Mode ! Lap memory: 50 laps
! Current, Average and Maximum Wind Speed Race Timer Mode
! Beaufort Scale for Average Wind Speed ! Resolution: 1 second
! 5 Wind Speed Unit Selection (Km/h, mph, ! Setting limit: 99 hours, 59 minutes, 59
feet/s, m/s, and Knots). seconds
! User defined time span for Average Wind ! Alarm sound:
Speed calculation.
! User defined Wind Speed Alarm. ! Last 10 minutes: beep once for every
minute.
Temperature Mode ! Last 10 seconds: beep once for every
! Current Temperature, and Current and second.
Minimum Wind Chill Temperatures. ! 0 second: beeps for about 2 seconds.
! User defined Wind Chill Temperature Alarm. Others
! Graphical and numerical displays for ! Electro-luminescent back-light turns on for 3
temperature for the last 24 hour seconds when activated.
Daily Alarm Mode
! Daily Alarm: 1 daily alarm
! Alarm Duration: about 30 seconds
12.1 Accuracy, resolution and units

Wind Speed
Up to 3.0 m/s, better than +/-10%
Over 3.0 m/s, better than +/-5%
Resolution: 0.1 m/s
Units: m/s, km/h, mph, knots, ft/s

Temperature
Better than +/-1 Celsius degree (offset
calibration possible)
Resolution: 0.1 degree
Units: Celsius, Fahrenheit

Time
Better than +/- 1 sec/day
13.0 Warranty
Brunton Two Year Warranty
To register this product:
Brunton warrants this product to be free of defects in
materials and workmanship for a period of two years. Print this form, fill out , and Send to Brunton at:
This warranty extends to the original purchaser from
the date of purchase. This warranty is void and a BRUNTON
charge for repair will be made if the ADC has been WARRANTY
damaged by negligence, accident or mishandling, or 2255 Brunton Court
has not been operated in accordance with standard Riverton, WY 82501
operating procedures, or if the ADC was altered or
repaired by anyone other than a Brunton repair facility.
---------------------------------------------------------------------------------------------------------
This warranty gives you specific legal rights, and you
also have rights, which vary from state to state. No
other warranty, expressed or implied, applies to the Name: ___________________________________________________________
Brunton product, nor is any person or company Address: _________________________________________________________
authorized to assume any other warranty for Brunton. City: _______________________ State: ___________ Zip: ________________
Brunton does not assume any responsibility for any Phone: ___________________________Email__________________________
consequential damages occasioned by this product. Date Purchased: ______________________
Should the product prove defective, contact Brunton, Amount Paid: _________________________
and you will be provided with a Return Authorization
Number (RA#). Send a copy of your proof of Would you like to receive a Brunton Catalog? ( )Yes ( )No
purchase, the RA#, a short description of the problem
and the product to Brunton at the following address. Please let us know where you purchased your ADC
Brunton suggests insuring the product in case of
Store Name: ________________________
damage or loss in shipment.
City: _______________________ State: ___________ Zip: ____________
( ) Online site _________________ ( ) Catalog ___________________
Brunton ( ) Gift ( ) Brunton
( ) Other _____________________
Warranty Repair (307) 857-4700
2255 Brunton Court support@brunton.com Do you own another Brunton Product?
Riverton, WY 82501 www.brunton.com ( ) Yes. Product: _____________________________ ( ) No.

I purchased this Brunton ADC primarily for...


( ) Profesional Use ( ) It was a gift ( ) It looked cool
( ) Recreational Use ( ) Other________________

También podría gustarte