Está en la página 1de 1

A B C D E F G H

DRAWING NO.
000-ST-S-002
1
.)
X TYP. 1/4"
A
1 (M 2000 (MAX.)
00
15 6
300 1500
25x4 TUBE 250 1500 250 100
32x4 TUBE
(MIN.) (MAX. STANCHION)
KICK PLATE
00 TYP. VAR.

400
3 .) STANCHION
IN > SPLICE TYP. HANDRAIL
(M PL6 6
1 40 40 32x4 TUBE

40
2

25
900
25x4 TUBE
00

65
32x4 TUBE

450
=1 P
.)
R

450
25x4 TUBE

500
Y
(T

PL6

90 DET. 21.1 KICK PLATE


KICK PLATE
P
L 100x6 STANCHION
KNEERAIL P
L 100x6

15
600
40x4 TUBE
60 RL FIN FL 25x4 TUBE

600
10 295
RL FIN FL
PL6mm
W.P.

MAX.
6
0x9
x8

70
0
C 25
PL3
RISE

MAX.
6
40
L8
P
(TYP.)

60
RL FIN FL
210 60 290 20 P
L6
5 5
L6
P TUBE SLEEVE GAP.
PL3
30 60 90
26 50x5
30
60

DETAIL 22 DETAIL 23
DETAIL 20 DETAIL 21
30

L8
P TYP.
REMOVABLE/INDIVIDUAL PANELS FIXED STANCHION DETAIL
STAIR HANDRAIL FIXED HANDRAIL

31
KICK PLATE STANCHION STANCHION
STANCHION 100
(TYP.)
60
KICK PLATE
STANCHION 32x4 TUBE HOLES 3/4"
PL20x8x40 32x4 TUBE 2" PIPING EMBEDMENT
L20x8x40
P EXPANSION BOLT 5/8"
L=150 PROJ.= 45 ON CONCRETE
40

40

6 MAX.
50 300
4 TYP. RL FIN FL 4
KICK PLATE
RL FIN FL

25
KICK PLATE

50

(MIN.)
50
HOLES 3/4"
15

70
15

125
PL3 TYP.
PL6 40 PL6

80
(TYP.)

60
10
VAR.

180
PL5Ox6 WITH

30
PIPE 2" L=150 L3
P 31 PIPE 2" L=150
HOLE 11/16"

60
PL3
WITH SLOTTED HOLE L8
P 30 PL75x75x6
40

40

PL10
11/16"x30 mm 30 30 L3
P

30
ON KICK PLATE
65

65

60

PL6
DETAIL 28
HOLES 11/16" DETAIL 21.1
L6
P
DETAIL 26 DETAIL 27
FOR 5/8" BOLTS
DETAIL 24
DETAIL 25
RAILING REMOVABLE IN CONCRETE FLOOR
(SEE NOTE 3)
3 3
REMOVABLE PANEL CONNECTION KICK PLATE CONNECTION FIXED CONCRETE RAILING
(SEE NOTE 3)

35 STANCHION
65 65 WALL FACE
(TYP.)
20

NOTES:
KICK PLATE
HANDRAIL 32x4 75

RL FIN FL PL20x8x40 1.- DIMENSIONS IN MILLIMETERS


KICK PLATE
TYP. 2.- ALL TUBULAR STEEL WORK SHALL BE IN ACCORDANCE

40
P
L10x150x200
70

65
> STANCHION
40

30 R=150 WITH ASTM A53 SCHEDULE 40 OR EQUIVALENT


0
(M (TYP.) STANCHION 3.- FABRICATOR TO ENSURE ADECUATE CLEARANCE BETWEEN

(MAX.)
AX

300
.)
(TYP.)

STANCHION & SLEEVE

P:\SCL_04_Eng_Dwg\01_Civ\04_Final\560-000-ST-S-002_2.dgn
150
80

24 >
00 4.- RL FIN FL = REFERENCE LEVEL FINISH FLOOR

100
(M P
L6
AX (TOP OF GRATING)
.)
35

(TOP FLOOR PLATE)


60

TUBE SLEEVE 25
HOLES 3/4" (TOP OF CONCRETE)
50x5
900

PL3 HOLE 11/16" 300 100


25
2 EXPANSION BOLT 5/8" EXPANSION BOLT 5/8" 2
50 (MAX.)
L=150 PROJ.= 45 FINISHED
L=150 PROJ.= 45
FLOOR LEVEL
DETAIL 31 DETAIL 32

STAIR
DETAIL 29 HANDRAIL CORNER DETAIL - TYPICAL HANDRAIL CORNER
DETAIL - ALTERNATIVE
DETAIL 30
RAILING REMOVABLE IN CONCRETE FLOOR
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
(SEE NOTE 3)
QUALITY CONTROL

WALL HANDRAIL DISCIPLINE MANAGER NAME SIGN

DOCUMENT CONTROL

THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN NAME SIGN & STAMP

11:47:56
SCALE: PROJECT
1 R E F E R E N C E S R E V I S I O N S R E V I S I O N S SHEET SIZE
1
DWG. NO. T I T L E NO. D E S C R I P T I O N BY CHECK APPROVED DATE NO. D E S C R I P T I O N BY CHECK APPROVED DATE
NOTICE NOT SCALE A1 TOROMOCHO PROJECT
AREA

THIS IS A COMPUTER GENERATED DRAWING. ALL CHANGES


DRAWN BY:
RSR DATE: 29.DEC.08
000 - GENERAL C-560 REVISION

HERE TO SHALL BE PERFORMED USING CADD ONLY.


TITLE CAD NO.
1
2 MODIFY INDICATE GSL RMA APR FAV 15-MAR-10 THIS DRAWING IS THE PROPERTY OF AND EMBODIES
CHECKED BY: RMA/FAF DATE: 29.DEC.08 GENERAL
PROPRIETARY INFORMATION BELONGING TO AKER
1 MODIFY INDICATE LSH RMA APR FAV 23-DEC-09 SOLUTIONS AND MUST BE RETURNED IMMEDIATELY UPON APPROVED BY: APR DATE: 21.JUL.09 STANDARD STEEL 560-000STS002.DGN 2

15/03/2010
REQUEST. IT MUST NOT BE COPIED IN WHOLE OR IN
0 ISSUED FOR CONSTRUCTION SCH RMA APR FAV 21.AUG.0 PART, NOR THE INFORMATION SHOWN THERE ON DISCLOSED
DWG. NO.

B ISSUED FOR CLIENT APPROVAL SCH RMA APR FAV 21.JUL.09


TO THIRD PARTIES EXCEPT WITH THE WRITTEN
PERMISSION.
AUTHORIZED BY: FAV DATE: 21.JUL.09
MINERA CHINALCO PERU S.A.
HANDRAILS
A ISSUED FOR INTERNAL COORDINATION RSR RMA RMA 29.DEC.08
MCP APPROVED: DATE:
DETAILS 000-ST-S-002
A B C D E F G

User: CSC3299

También podría gustarte