Está en la página 1de 38

Ledex® Tubular

Linear Solenoids
45

10% Duty Cycle 70W


25% Duty Cycle 28W
50% Duty Cycle 14W
36 100% Duty Cycle 7W

27
Force – N

18

0 2.5 5.0 7.5 10.0 12.5

Stroke – mm

24

10% Duty Cycle 70W


25% Duty Cycle 28W
20 50% Duty Cycle 14W
100% Duty Cycle 7W

16
Force – N

12
Ledex® Tubular Solenoids
■ STA® Series has enhanced ■ Strokes up to 64 mm
design features and
improved performance ■ Life rating of 25 million
actuations for STA designs
■ Push and pull models

All catalogue products manufactured after


April 1, 2006 are RoHS Compliant

Performance Curves Duty Cycle


The performance curves Duty cycle is determined
in this section serve as by: ON time/(ON + OFF
LINEAR Tubular

guides to determine the time).


solenoid size needed to For example: a solenoid
produce a desired force is actuated for 30 seconds,
at a given stroke, duty then off for 90 seconds.
cycle, and power source. 30 sec ON / (30 Sec ON + 90
All curves were developed sec OFF) = 30/120 = 1/4 or
The Ledex® STA Series Design Considerations under the following 25% duty cycle.
of tubular solenoids is
standard test conditions: Ledex tubular solenoids
available in three sizes Pull versus Push Type ambient temperature are rated for various
of 13, 20 and 26 mm In Pull type solenoids, of 20°C, 65% relative duty cycles ranging from
diameter. Both push and the plunger is pulled into humidity. continuous to 10% duty.
pull types are available. the solenoid coil when the Note that maximum
Additionally, each size coil is energised. In Push Starting Force ON time for a particular
and type is available with type solenoids, the same is When determining application can be a factor
a choice of two plunger true, however, the plunger an application’s force which overrides the duty
configurations: flat face has a shaft extension requirement, apply a 1.5 cycle rating. For example,
and 60°, as well as with or which then pushes out safety factor. For example: at 25% duty cycle, the
without an anti-rotation through a hole in the a load requiring 1.0 N maximum ON time for a
flat on the mounting end of the solenoid case. of force should utilise a given Ledex solenoid is
bushing. These options Please note, however, that solenoid providing 1.0 N x 36 seconds. If, however,
offer maximum force for a the magnetic field cannot 1.5 or 1.5 N of force. the solenoid is operated
wide range of applications. be reversed to cause the at a cycle rate which
The new design also opposite action to occur. enables the unit to return
improves performance
Pull Type Push Type to ambient temperature
and provides longer life
Shaft between ON cycles, then
than previous tubular Plunger Plunger
Extension
the maximum ON time is
designs. They offer quiet
extended somewhat. In
operation and improved
the above example, this
reliability for demanding De-energised De-energised extended ON time is 44
applications.
seconds. Maximum ON
time ratings are listed
on the individual model
Energised Energised specification pages.

Ledex® Solenoids F2 www.ledex.com


Ledex® Tubular Solenoids
Life STA Construction about your application as Size 125M, 150M, 175M
When selecting a tubular The STA is constructed tooling may apply to some Standard Tubular Models
solenoid, as with any with a low friction nylon features.
for Large Loads
other solenoid style, it bobbin which insures a
STA Plunger Ledex Size 125M, 150M,
is important to consider 25 million actuations life
and 175M standard tubular
the effects of heat on life. rating on all models. Configurations
models are offered for
When used with a constant The problems associated With two standard heavy duty applications
voltage supply, an increase with powdered metal plunger configurations to requiring larger forces.
in coil temperature flaking in typical tubular choose from, the new STA These standard models are
reduces the work output designs is eliminated Series offers stroke lengths all pull type and offered
and the life of the unit. with the metal-to-plastic up to 18 mm and up to 107 with 60° plungers. These
Standard life is 25,000,000 bearing surface. In N of force. models feature heavy
actuations for STA designs. addition, the new design’s
duty welded mounting
case is rolled over both A. Flat Face
brackets, and heavy duty
Power Requirements ends of the unit for greater For strokes typically less plunger stops to limit
Voltage applied to the shock and vibration than 1.5 mm, the flat face plunger travel, provide
solenoid must be matched integrity, allowing the plunger is recommended positive stopping, and keep
to the coil wire size for STA to withstand severe with a pull or push force pole faces from slamming
proper operation. Solenoids applications in which three to five times greater together at the end of
are catalogued in coil awgs typical solenoids may than 60° plungers. stroke.

LINEAR Tubular
ranging from #23 up to #37 come apart.
An impact cushion
to accommodate your input Both push and pull A Flat Face
(180°) made of resilient non-
power. models offer a built-in
magnetic material absorbs
Refer to the individual combination air gap
energy at the end of the
model specification spacer and plunger stop.
B. 60° Angle stroke. This cushion also
pages for coil wire awg This feature eliminates the
For longer strokes helps eliminate residual
recommendations. Many need for external E-rings
up to 19 mm, the 60° magnetism.
other coil awg sizes are and impact washers which
plunger offers the greatest Size 125M, 150M, and
available. Please feel free typically fail prematurely,
advantage over the flat 175M models are available
to contact our application as well as get in the
face plunger. with other plunger
engineering department way of your attached
configurations, in push
for availability. mechanisms.
type models, and with
All units are provided B 60°
other mountings. Please
Tubular Applications with 250 mm PVC lead
consult the factory as
The STA Series is wires as standard, and
tooling may apply.
particularly ideal for are rated for a maximum
applications where field coil temperature of 130°C.
service is prohibitive. Its UL-approved materials are A: Flat Face

long life and high reliability used in the construction.


are definite advantages in For higher temperature
applications involving: applications up to 180°C,
Force

C: 60° Cone
• Computer peripherals please consult the factory
• Industrial sewing for alternate materials
machines which are available in
• Automated teller some models. Mechanical Stroke
machines and electrical ratings may
• Blood analyzers also be affected. Other
• Gate mechanisms options include: special
• Packaging machinery plunger configurations,
• Door interlocks springs, special mounting
• Sorting machines features, and anti-
• Glue dispensers rotation flats on mounting
• Laboratory equipment bushings. Please consult
• Business machines the factory with details

Ledex® Solenoids F3 www.ledex.com


Ledex® Tubular Solenoids Selection
Tubular solenoids are
All catalogue products manufactured after
available in seven sizes.
April 1, 2006 are RoHS Compliant
The four STA Series sizes
are available in both push
and pull types. Tubular Selection Overview
Use the selection Package Max Nominal Force (N) @ Nominal Stroke
overview chart to Solenoid Dimension (mm) Stroke Stroke and Specified Duty Cycle
determine which size Size Type Dia. Length (mm) (mm) 100% 50% 25% 10%
offers the desired STA 13 x 14 Pull 13.2 13.9 2.5 1.3 0.80 1.33 2.22 4.45
performance and Mag Latch* 13 x 16 Pull 13.2 15.7 3.8 1.9 – 1.11 2.14 3.34
mechanical specifications.
STA 13 x 14 Push 13.2 13.9 2.5 1.3 0.36 0.80 1.11 2.67
Refer to the individual
size specification pages for STA 13 x 27 Pull 13.2 26.7 12.5 2.5 0.84 1.38 2.49 4.45
complete performance and STA 13 x 27 Push 13.2 26.7 12.5 2.5 0.58 1.11 2.14 4.18
mechanical data. STA 13 x 52 Pull 13.2 52.1 20.0 7.5 0.27 0.53 1.02 1.82
STA 20 x 40 Pull 19.6 39.4 17.5 5.1 2.22 4.45 7.25 11.97
Well-suited STA 20 x 40 Push 19.6 39.4 17.5 5.1 1.69 3.56 6.68 12.24
for battery STA 26 x 30 Pull 25.9 29.8 12.5 2.5 7.80 12.9 21.36 36.49
operation. STA 26 x 52 Pull 25.9 52.1 17.5 7.6 4.00 7.79 13.35 23.14
See the "Battery Operated STA 26 x 52 Push 25.9 52.1 17.5 7.6 3.34 8.37 12.90 23.14
LINEAR Tubular

Solenoids" section for


Size 125M 32 x 57 Pull 31.8 57.2 18.0 10.2 4.45 8.90 17.80 28.92
complete information.
Size 150M 38 x 64 Pull 38.1 63.5 20.0 10.2 4.45 11.12 23.14 43.61
Size 175M 44 x 120 Pull 44.4 119.7 63.5 25.4 5.56 11.12 16.69 28.92
All data is at 20°C coil temperature. Force outputs degrade with elevated temperatures.
* See the "Magnetic Latching Solenoids" section for complete information on all our
magnetic latching solenoids.

How to Use Tubular Performance Charts


Performance
1. Select one of the four columns which provides the Maximum Duty Cycle 100% 50% 25% 10%
appropriate duty cycle. (For example 50%.) Maximum ON Time (sec)
∞ 50 5 2
when pulsed continuously
2. Reading down this column provides a variety of Maximum ON Time (sec)
∞ 140 30 8
for single pulse
performance and electrical data including maximum on
Watts (@ 20°C) 4 8 16 40
time, watts, and amp turns.
Ampere Turns (@ 20°C) 497 704 994 1573
3. Following down the column further into the VDC Coil Data
ratings, select the voltage which most closely matches awg Resistance # VDC VDC VDC VDC
(0XX) (@20°C) Turns (Nom) (Nom) (Nom) (Nom)
your supply voltage. (For example, 11.5 for a 12 VDC
27 1.43 306 2.4 3.4 4.8 7.6
power supply.) 28 1.95 342 2.8 3.9 5.6 8.8
29 3.84 508 3.9 5.5 7.8 12.4
4. Read across (to the left) to select the awg suffix . (In 30 5.29 572 4.6 6.5 9.2 14.5
this example, 32 awg is required, thus to order, specify: 31 9.56 795 6.2 8.8 12.4 19.6
195223-232. 32 16.54 1068 8.1 11.5 16.3 25.7
33 22.60 1194 9.5 13.4 19.0 30.0
Note that the digit preceding the awg refers to the 34 37.41 1547 12.2 17.3 24.0 39.0
plunger configuration and anti-rotation flat selected. 35 60.71 1976 15.6 22.0 31.0 49.0
Review the STA plunger section on page E3 and on the 36 96.19 2475 19.6 28.0 39.0 62.0
individual specification page to select the appropriate 37 149.93 3060 24.5 35.0 49.0 77.0
plunger configuration.

Note: The size 102M, 125M, 150M and 175M standard


models do not use this plunger configuration and anti-
rotation flat suffix system. All specifications subject to change without notice.

Ledex® Solenoids F4 www.ledex.com


Ledex® Tubular Solenoids Design Modifications
Options and Typical Examples ofOff
Power Take Custom Features
Modified Designs
Even though many
solenoid designs are
in stock and available
via distribution, our Elliptical Clevis-grooved
customers often require
a product with unique
features or performance
capabilities. In fact, almost
80% of all solenoids
that we make are either
Flatted Clevis-tongue
modified or custom built to
meet our customers’ exact
application requirements.
So, if you don’t find what
you’re looking for in the
catalogue, give us a call to
discuss your needs with Drilled hole Notched
one of our application

LINEAR Tubular
engineers.

Threaded rod Tapped hole

Ledex® Solenoids F5 www.ledex.com


STA® Pull Tubular Solenoids — 13 mm Dia. x 14 mm
Part Number: 195220 - X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


2 60° plunger without anti-rotation flat
Well-suited 6 60° plunger with anti-rotation flat
for battery
operation.
See the "Battery Operated
Solenoids" section for
complete information.

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) ∞ 50 5 2 Recommended Maximum watts dissipated by
LINEAR Tubular

when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 140 30 8 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 3 6 12 30 aluminium plate measuring 51 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 268 379 536 847
Coil Resistance ±5% tolerance
Coil Data
Weight 14.5 g
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Dimensions See page F31
27 0.48 108 1.2 1.7 2.4 3.8
28 0.67 123 1.5 2.1 2.9 4.6
29 1.33 184 1.9 2.7 3.9 6.1
30 1.80 204 2.4 3.3 4.7 7.5
31 3.33 290 3.1 4.4 6.2 9.7
32 4.57 325 3.8 5.3 7.5 11.9
33 7.80 432 4.8 6.8 9.7 15.3 How to Order
34 13.10 567 6.2 8.8 12.4 19.6 Add the plunger configuration, anti-rotation flat
35 17.80 630 7.6 11.0 15.0 24.0
36 29.05 808 9.6 14.0 19.0 30.0 number, and the coil awg number to the part number
37 45.70 1008 12.2 17.0 24.0 38.0 (for example: to order a unit with a 60° plunger
1
Continuously pulsed at stated watts and duty cycle configuration without an anti-rotation flat rated for 4.7
2
Single pulse at stated watts (with coil at ambient room VDC at 25% duty cycle, specify 195220-230.
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.

All specifications subject to change without notice.

Ledex® Solenoids F6 www.ledex.com


STA® Pull Tubular Solenoids — 13 mm Dia. x 14 mm
Pull Tubular Solenoid – 13 mm dia. x 14 mm – 60° Plunger

Typical Force @ 20°C Typical Speed @ No Load, 20°C


11.0 24

100% Duty Cycle


50% Duty Cycle
20 25% Duty Cycle
8.8 10% Duty Cycle

10% Duty Cycle 16


25% Duty Cycle

Speed – ms
6.6 50% Duty Cycle
Force - N

100% Duty Cycle


12

4.4
8

2.2
4

LINEAR Tubular
0 0.6 1.2 1.8 2.4 0 0.5 1.0 1.5 2.0 2.5

Stroke - mm Stroke – mm

All specifications subject to change without notice.

Ledex® Solenoids F7 www.ledex.com


STA® Pull Magnetic Latching Solenoid — 13 mm Dia. x 16 mm
Part Number: 151094 - X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


1 Flat Face plunger without anti-rotation flat on mounting
Well-suited 2 60° plunger without anti-rotation flat on mounting
for battery 5 Flat Face plunger with anti-rotation flat on mounting
operation. 6 60° plunger with anti-rotation flat on mounting

See the "Battery Operated


Solenoids" section for A
complete information. Coil Polarity (Red)

Latch: A+ B-
Unlatch: A- B+

B
(Black)
LINEAR Tubular

Performance Specifications
Unlatched Operation Pull
Maximum Duty Cycle Voltage 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) n/a 50 5 2 Recommended Maximum watts dissipated by solenoid
when pulsed continuously1 Minimum Heat Sink are based on an unrestricted flow of air
at 2 0°C, with solenoid mounted on the
Watts (@ 20°C) 3 6 12 30 equivalent of an aluminium plate
Ampere Turns (@ 20°C) 268 379 536 847 measuring 51 mm square by 3.2 mm
Coil Data thick
Unlatch Voltage See schematic and coil data
awg Resistance # Unlatched VDC VDC VDC
(0XX)2 (@20°C) Turns3 VDC (Nom) (Nom) (Nom) Magnet Hold Force 2 N (with return spring)
Coil Insulation Class "B"; 130°C max. temperature
27 0.48 108 1.2 1.7 2.4 3.8 standard. Other temperature classes are
28 0.67 123 1.5 2.1 2.9 4.6 available.
29 1.33 184 1.9 2.7 4.0 6.1 Spring Force 0.38 N/mm; 1.2 N latched position
30 1.80 204 2.4 3.3 4.7 7.5 Weight 14.7 g
31 3.33 290 3.1 4.4 6.2 9.7 Plunger Weight 2.6 g
32 4.57 325 3.8 5.3 7.5 11.9
Dimensions See page F31
33 7.80 432 4.8 6.8 9.7 15.3
34 13.10 567 6.2 8.8 12.4 20.0
35 17.80 630 7.6 11.0 15.0 24.0
36 29.05 808 9.6 14.0 19.0 30.0
37 45.70 1008 12.2 17.0 24.0 38.0
1
Continuously pulsed at stated watts and duty cycle How to Order
2
Other coil awg sizes available — please consult factory Add the plunger configuration, anti-rotation flat
3
Reference number of turns number, and the coil awg number to the part number
(for example: to order a 60° plunger unit without an anti-
rotation flat, rated for 4.7 VDC at 25% duty cycle, specify
151094-230.
Please see www.ledex.com (click on Stock Products
tab) for our list of stock products available through our
distributors.

All specifications subject to change without notice.

Ledex® Solenoids F8 www.ledex.com


STA® Pull Magnetic Latching Solenoid — 13 mm Dia. x 16 mm
Pull Tubular Solenoid – 13 mm dia. x 16 mm – 60° Plunger

Typical Force @ 20°C (Net, with Spring)


7.8

6.5

10% Duty Cycle


5.2 25% Duty Cycle
50% Duty Cycle
Force - N

3.9

2.6

1.3

LINEAR Tubular
0
0 0.6 1.2 1.8 2.4 3.0 3.6

Stroke - mm

All specifications subject to change without notice.

Ledex® Solenoids F9 www.ledex.com


STA® Push Tubular Solenoids — 13 mm Dia. x 14 mm
Part Number: 195221- X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


2 60° plunger without anti-rotation flat
Well-suited 6 60° plunger with anti-rotation flat
for battery
operation.
See the "Battery Operated
Solenoids" section for
complete information.

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) ∞ 50 5 2 Recommended Maximum watts dissipated by
LINEAR Tubular

when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 140 30 8 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 3 6 12 30 aluminium plate measuring 51 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 268 379 536 847
Coil Resistance ±5% tolerance
Coil Data
Weight 14.5 g
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Dimensions See page F31
27 0.48 108 1.2 1.7 2.4 3.8
28 0.67 123 1.5 2.1 2.9 4.6
29 1.33 184 1.9 2.7 3.9 6.1
30 1.80 204 2.4 3.3 4.7 7.5
31 3.33 290 3.1 4.4 6.2 9.7
32 4.57 325 3.8 5.3 7.5 11.9
33 7.80 432 4.8 6.8 9.7 15.3 How to Order
34 13.10 567 6.2 8.8 12.4 19.6 Add the plunger configuration, anti-rotation flat
35 17.80 630 7.6 11.0 15.0 24.0 number, and the coil awg number to the part number
36 29.05 808 9.6 14.0 19.0 30.0
37 45.70 1008 12.2 17.0 24.0 38.0 (for example: to order a unit with a 60° plunger
configuration without an anti-rotation flat rated for 4.7
1
Continuously pulsed at stated watts and duty cycle
VDC at 25% duty cycle, specify 195221-230.
2
Single pulse at stated watts (with coil at ambient room
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.

All specifications subject to change without notice.

Ledex® Solenoids F10 www.ledex.com


STA® Push Tubular Solenoids — 13 mm Dia. x 14 mm
Push Tubular Solenoid – 13 mm dia. x 14 mm – 60° Plunger

Typical Force @ 20°C Typical Speed @ No Load, 20°C


4.8 24

100% Duty Cycle


50% Duty Cycle
4.0 20 25% Duty Cycle
10% Duty Cycle
10% Duty Cycle
3.2 25% Duty Cycle
50% Duty Cycle 16
100% Duty Cycle

Speed – ms
Force - N

2.4 12

1.6 8

0.8 4

0
0 0.6 1.2 1.8 2.4 0 0.5 1.0 1.5 2.0 2.5

LINEAR Tubular
Stroke - mm Stroke – mm

All specifications subject to change without notice.

Ledex® Solenoids F11 www.ledex.com


STA® Pull Tubular Solenoids — 13 mm Dia. x 27 mm
Part Number: 195222 - X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


1 Flat face plunger without anti-rotation flat
Well-suited 2 60° plunger without anti-rotation flat
for battery 5 Flat face plunger with anti-rotation flat
operation. 6 60° plunger with anti-rotation flat

See the "Battery Operated


Solenoids" section for
complete information.

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) ∞ 50 5 2 Recommended Maximum watts dissipated by solenoid
LINEAR Tubular

when pulsed continuously1 Minimum Heat Sink are based on an unrestricted flow of
Maximum ON Time (sec) ∞ 140 30 8 air at 20°C, with solenoid mounted on
for single pulse2 the equivalent of an aluminium plate
Watts (@ 20°C) 4 8 16 40 measuring 51 mm square by 3.2 mm
thick
Ampere Turns (@ 20°C) 497 704 994 1573
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 5 .3 N @ 20°C
awg Resistance # VDC VDC VDC VDC 60°: 4.0 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 24.7 g
27 1.43 306 2.4 3.4 4.8 7.6
28 1.95 342 2.8 3.9 5.6 8.8 Plunger Weight 4.5 g
29 3.84 508 3.9 5.5 7.8 12.4 Dimensions See page F32
30 5.29 572 4.6 6.5 9.2 14.5
31 9.56 795 6.2 8.8 12.4 19.6
32 16.54 1068 8.1 11.5 16.3 25.7
33 22.60 1194 9.5 13.4 19.0 30.0 How to Order
34 37.41 1547 12.2 17.3 24.0 39.0 Add the plunger configuration, anti-rotation flat
35 60.71 1976 15.6 22.0 31.0 49.0 number, and the coil awg number to the part number
36 96.19 2475 19.6 28.0 39.0 62.0
37 141.93 3060 23.8 33.7 47.6 75.3 (for example: to order a unit with a 60° plunger
configuration without an anti-rotation flat rated for 4.8
1
Continuously pulsed at stated watts and duty cycle
VDC at 25% duty cycle, specify 195222-227.
2
Single pulse at stated watts (with coil at ambient room
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.

All specifications subject to change without notice.

Ledex® Solenoids F12 www.ledex.com


STA® Pull Tubular Solenoids — 13 mm Dia. x 27 mm
Pull Tubular Solenoid – 13 mm dia. x 27 mm – Flat Face Plunger
Typical Force @ 20°C Typical Speed @ No Load, 20°C
12.0 24

10% Duty Cycle 40W 100% Duty Cycle 4W


25% Duty Cycle 16W 50% Duty Cycle 8W
10.0 50% Duty Cycle 8W 20 25% Duty Cycle 16W
100% Duty Cycle 4W 10% Duty Cycle 40W

8.0 16

Speed – ms
Force – N

6.0 12

4.0 8

2.0 4

0 1.25 2.5 3.75 5.0 6.25 0 1.25 2.5 3.75 5.0 6.25

Stroke – mm Stroke – mm

Pull Tubular Solenoid – 13 mm dia. x 27 mm – 60° Plunger

LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
8.0 60

10% Duty Cycle 40W 100% Duty Cycle 4W


25% Duty Cycle 16W 50% Duty Cycle 8W
50% Duty Cycle 8W 50 25% Duty Cycle 16W
100% Duty Cycle 4W 10% Duty Cycle 40W
6.0

40
Speed – ms
Force – N

4.0 30

20

2.0

10

0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5

Stroke – mm Stroke – mm

All specifications subject to change without notice.

Ledex® Solenoids F13 www.ledex.com


STA® Push Tubular Solenoids — 13 mm Dia. x 27 mm
Part Number: 195223 - X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


1 Flat face plunger without anti-rotation flat
Well-suited 2 60° plunger without anti-rotation flat
for battery 5 Flat face plunger with anti-rotation flat
operation. 6 60° plunger with anti-rotation flat

See the "Battery Operated


Solenoids" section for
complete information.

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) ∞ 50 5 2 Recommended Maximum watts dissipated by
LINEAR Tubular

when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 140 30 8 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 4 8 16 40 aluminium plate measuring 51 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 497 704 994 1573
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 4.5 N @ 20°C
awg Resistance # VDC VDC VDC VDC 60°: 3.2 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 25.2 g
27 1.43 306 2.4 3.4 4.8 7.6
28 1.95 342 2.8 3.9 5.6 8.8 Plunger Weight 3.1 g
29 3.84 508 3.9 5.5 7.8 12.4 Dimensions See page F32
30 5.29 572 4.6 6.5 9.2 14.5
31 9.56 795 6.2 8.8 12.4 19.6
32 16.54 1068 8.1 11.5 16.3 25.7
33 22.60 1194 9.5 13.4 19.0 30.0 How to Order
34 37.41 1547 12.2 17.3 24.0 39.0
35 60.71 1976 15.6 22.0 31.0 49.0 Add the plunger configuration, anti-rotation flat
36 96.19 2475 19.6 28.0 39.0 62.0 number and the coil awg number to the part number
37 141.93 3060 23.8 33.7 47.6 75.3 (for example: to order a unit with a 60° plunger
1
Continuously pulsed at stated watts and duty cycle configuration without anti-rotation rated for 4.8 VDC at
2
Single pulse at stated watts (with coil at ambient room 25% duty cycle, specify 195223-227.
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.

All specifications subject to change without notice.

Ledex® Solenoids F14 www.ledex.com


STA® Push Tubular Solenoids — 13 mm Dia. x 27 mm
Push Tubular Solenoid – 13 mm dia. x 27 mm – Flat Face Plunger

Typical Force @ 20°C Typical Speed @ No Load, 20°C


8 24

10% Duty Cycle 40W 100% Duty Cycle 4W


25% Duty Cycle 16W 50% Duty Cycle 8W
50% Duty Cycle 8W 20 25% Duty Cycle 16W
100% Duty Cycle 4W 10% Duty Cycle 40W
6

16

Speed – ms
Force – N

4 12

0 1.25 2.5 3.75 5.0 6.25 0 1.25 2.5 3.75 5.0 6.25

Stroke – mm Stroke – mm

Push Tubular Solenoid – 13 mm dia. x 27 mm – 60° Plunger

LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
8 60

10% Duty Cycle 40W 100% Duty Cycle 4W


25% Duty Cycle 16W 50% Duty Cycle 8W
50% Duty Cycle 8W 50 25% Duty Cycle 16W
100% Duty Cycle 4W 10% Duty Cycle 40W
6

40
Speed – ms
Force – N

4 30

20

10

0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5

Stroke – mm Stroke – mm

All specifications subject to change without notice.

Ledex® Solenoids F15 www.ledex.com


STA® Pull Tubular Solenoids — 13 mm Dia. x 52 mm
Part Number: 153092 - X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


2 60° plunger without anti-rotation flat
Well-suited 6 60° plunger with anti-rotation flat
for battery
operation.
See the "Battery Operated
Solenoids" section for
complete information.

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) ∞ 62 18 5 Recommended Maximum watts dissipated by
LINEAR Tubular

when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 179 59 15 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 4.8 9.6 19.2 48 aluminium plate measuring 51 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 762 1078 1525 2410
Coil Resistance ±5% tolerance
Coil Data
Holding Force 60°: 3.9 N at 20°C
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Weight 42.5 g
27 2.03 456 3.1 4.4 6.2 9.9 Plunger Weight 8.5 g
28 4.57 765 4.7 6.6 9.4 14.8 Dimensions See page F33
29 6.30 855 5.5 7.8 11.0 17.4
30 12.34 1276 7.7 10.9 15.4 24.3
31 17.70 1430 9.2 13.0 18.4 29.1
32 30.45 1985 12.1 17.1 24.2 38.2
33 45.10 2350 14.7 20.8 29.4 46.5
34 72.70 2998 18.7 26.4 37.4 59.1
35 118.71 3850 23.9 33.8 47.7 75.5
36 173.00 4510 28.8 40.8 57.6 91.1 How to Order
1
Continuously pulsed at stated watts and duty cycle Add the plunger configuration and the coil awg
2
Single pulse at stated watts (with coil at ambient room number to the part number (for example: to order a unit
temperature 20°C) with a 60° plunger configuration without an anti-rotation
3
Other coil awg sizes available — please consult factory flat rated for 6.2 VDC at 25% duty cycle, specify 153092-
4
Reference number of turns 227.
Please see www.ledex.com (click on Stock Products
tab) for our list of stock products available through our
North American distributors.

All specifications subject to change without notice.

Ledex® Solenoids F16 www.ledex.com


STA® Pull Tubular Solenoids — 13 mm Dia. x 52 mm
Pull Tubular Solenoid – 13 mm dia. x 52 mm – 60° Plunger

Typical Force @ 20°C


8

10% Duty Cycle 55W


25% Duty Cycle 22W
50% Duty Cycle 11W
100% Duty Cycle 5.5W
6
Force – N

0 2.54 5.08 7.5 10.0 12.5 15.0 17.5 20.0

Stroke – mm

LINEAR Tubular
Typical Speed @ No Load, 20°C
60

50 100% Duty Cycle


50% Duty Cycle
25% Duty Cycle
10% Duty Cycle
40
Speed – ms

30

20

10

0 0.5 1.0 1.5 2.0 2.5

Stroke – mm

All specifications subject to change without notice.

Ledex® Solenoids F17 www.ledex.com


STA® Pull Tubular Solenoids — 20 mm Dia. x 40 mm
Part Number: 195224 - X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


1 Flat face plunger without anti-rotation flat
Well-suited 2 60° plunger without anti-rotation flat
for battery 5 Flat face plunger with anti-rotation flat
operation. 6 60° plunger with anti-rotation flat

See the "Battery Operated


Solenoids" section for
complete information.

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 230 25 6 Recommended Maximum watts dissipated by
LINEAR Tubular

when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 265 63 15 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
aluminium plate measuring 76 mm
Watts (@ 20°C) 7 14 28 70
square by 3.2 mm thick
Ampere Turns (@ 20°C) 855 1200 1700 2700
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 23.3 N @ 20°C
awg Resistance # VDC VDC VDC VDC 60°: 12.8 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 83.6 g
24 1.10 330 2.7 3.8 5.6 8.8
Plunger Weight 20.1 g
25 2.13 488 3.9 5.5 7.7 12.2
26 2.90 544 4.5 6.4 9.0 14.2 Dimensions See page F34
27 5.27 760 6.1 8.6 12.1 19.2
28 9.15 1026 8.0 11.3 16.0 25.0
29 12.50 1146 9.4 13.2 18.7 30.0
30 20.70 1491 12.0 17.0 24.0 38.0 How to Order
31 33.60 1904 15.0 22.0 31.0 48.0
32 53.50 2394 19.4 27.0 39.0 61.0 Add the plunger number and the coil awg number to
33 83.50 2970 24.0 34.0 48.0 76.0 the part number (for example: to order a unit with a 60°
1
Continuously pulsed at stated watts and duty cycle plunger configuration without an anti-rotation flat rated
2
Single pulse at stated watts (with coil at ambient room for 12.1 VDC at 25% duty cycle, specify 195224-227.
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.

All specifications subject to change without notice.

Ledex® Solenoids F18 www.ledex.com


STA® Pull Tubular Solenoids — 20 mm Dia. x 40 mm
Pull Tubular Solenoid – 20 mm dia. x 40 mm – Flat Face Plunger

Typical Force @ 20°C Typical Speed @ No Load, 20°C


45 50

10% Duty Cycle 70W 100% Duty Cycle 7W


25% Duty Cycle 28W 50% Duty Cycle 14W
50% Duty Cycle 14W 25% Duty Cycle 28W
36 100% Duty Cycle 7W 40 10% Duty Cycle 70W

Speed – ms
27 30
Force – N

18 20

9 10

0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5

Stroke – mm Stroke – mm

Pull Tubular Solenoid – 20 mm dia. x 40 mm – 60° Plunger

LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C

24 50

10% Duty Cycle 70W 100% Duty Cycle 7W


25% Duty Cycle 28W 50% Duty Cycle 14W
20 50% Duty Cycle 14W 25% Duty Cycle 28W
100% Duty Cycle 7W 40 10% Duty Cycle 70W

16
Speed – ms

30
Force – N

12

20
9

10
4

0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 0 2.5 5.0 7.5 10.0 12.5 15.0 17.5

Stroke – mm Stroke – mm

All specifications subject to change without notice.

Ledex® Solenoids F19 www.ledex.com


STA® Push Tubular Solenoids — 20 mm Dia. x 40 mm
Part Number: 195225 - X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


1 Flat face plunger without anti-rotation flat
Well-suited 2 60° plunger without anti-rotation flat
for battery 5 Flat face plunger with anti-rotation flat
operation. 6 60° plunger with anti-rotation flat

See the "Battery Operated


Solenoids" section for
complete information.

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 230 25 6 Recommended Maximum watts dissipated by
LINEAR Tubular

when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 265 63 15 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 7 14 28 70 aluminium plate measuring 76 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 855 1200 1700 2700
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 22.0 N @ 20°C
awg Resistance # VDC VDC VDC VDC 60°: 12.7 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 87.3 g
24 1.10 330 2.7 3.8 5.6 8.8
25 2.13 488 3.9 5.5 7.7 12.2 Plunger Weight 15.0 g
26 2.90 544 4.5 6.4 9.0 14.2 Dimensions See page F34
27 5.27 760 6.1 8.6 12.1 19.2
28 9.15 1026 8.0 11.3 16.0 25.0
29 12.50 1146 9.4 13.2 18.7 30.0
30 20.70 1491 12.0 17.0 24.0 38.0 How to Order
31 33.60 1904 15.0 22.0 31.0 48.0
32 53.50 2394 19.4 27.0 39.0 61.0 Add the plunger number and the coil awg number to
33 83.50 2970 24.0 34.0 48.0 76.0 the part number (for example: to order a unit with a 60°
1
Continuously pulsed at stated watts and duty cycle plunger configuration without an anti-rotation flat rated
2
Single pulse at stated watts (with coil at ambient room for 12.1 VDC at 25% duty cycle, specify 195225-227.
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.

All specifications subject to change without notice.

Ledex® Solenoids F20 www.ledex.com


STA® Push Tubular Solenoids — 20 mm Dia. x 40 mm
Push Tubular Solenoid – 20 mm dia. x 40 mm – Flat Face Plunger

Typical Force @ 20°C Typical Speed @ No Load, 20°C


36 50

10% Duty Cycle 70W 100% Duty Cycle 7W


25% Duty Cycle 28W 50% Duty Cycle 14W
50% Duty Cycle 14W 25% Duty Cycle 28W
100% Duty Cycle 7W 40 10% Duty Cycle 70W
27

Speed – ms
30
Force – N

18

20

9
10

0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5

Stroke – mm Stroke – mm

Push Tubular Solenoid – 20 mm dia, x 40 mm – 60° Plunger

LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
24 50
10% Duty Cycle 70W 100% Duty Cycle 7W
25% Duty Cycle 28W 50% Duty Cycle 14W
50% Duty Cycle 14W 25% Duty Cycle 28W
20 100% Duty Cycle 7W
40 10% Duty Cycle 70W

16
Speed – ms

30
Force – N

12

20
8

10
4

0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 0 2.5 5.0 7.5 10.0 12.5 15.0 17.5

Stroke – mm Stroke – mm

All specifications subject to change without notice.

Ledex® Solenoids F21 www.ledex.com


STA® Pull Tubular Solenoids — 26 mm Dia. x 30 mm
Part Number: 153099 - X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


2 60° plunger without anti-rotation flat
6 60° plunger with anti-rotation flat

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 104 24 8 Recommended Maximum watts dissipated by
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 187 55 18 flow of air at 20°C, with solenoid
LINEAR Tubular

for single pulse2 mounted on the equivalent of an


Watts (@ 20°C) 8 16 32 80 aluminum plate measuring 102 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 718 1015 1435 2270
Coil Resistance ±5% tolerance
Coil Data
Holding Force 21.8 N at 20°C
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Weight 110 g
23 0.88 240 2.7 3.8 5.3 8.4 Plunger Weight 28 g
24 1.23 272 3.1 4.4 6.3 9.9 Dimensions See page 35
25 2.23 380 4.2 6.0 8.4 13.3
26 3.85 510 5.6 7.8 11.1 17.6
27 5.32 576 6.5 9.2 13.0 20.6
28 8.83 749 8.4 11.9 16.8 26.6 How to Order
29 14.35 960 10.7 15.1 21.4 33.8
30 22.78 1206 13.5 19.1 27.0 42.7 Add the plunger configuration and the coil awg number
31 35.69 1500 16.9 23.9 33.8 53.4 to the part number (for example: to order a unit with a
32 54.90 1837 21.0 29.7 42.0 66.4 60° plunger configuration without an anti-rotation flat
33 93.08 2431 27.3 38.6 54.6 86.3
rated for 5.3 VDC at 25% duty cycle, specify 153099-223.
1
Continuously pulsed at stated watts and duty cycle
Please see www.ledex.com (click on Stock Products
2
Single pulse at stated watts (with coil at ambient room
tab) for our list of stock products available through our
temperature 20°C)
North American distributors.
3
Other coil awg sizes available — please consult factory
4
Reference number of turns

All specifications subject to change without notice.

Ledex® Solenoids F22 www.ledex.com


STA® Pull Tubular Solenoids — 26 mm Dia. x 30 mm
Pull Tubular Solenoid – 26 mm dia, x 30 mm – 60° Plunger

Typical Force @ 20°C

54

10% Duty Cycle 85W


25% Duty Cycle 34W
45 50% Duty Cycle 17W
100% Duty Cycle 8.5W

36
Force – N

27

18

0 2.5 5.0 7.5 10.0 12.5

LINEAR Tubular
Stroke – mm

All specifications subject to change without notice.

Ledex® Solenoids F23 www.ledex.com


STA® Pull Tubular Solenoids — 26 mm Dia. x 52 mm
Part Number: 195226 - X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


1 Flat face plunger without anti-rotation flat
2 60° plunger without anti-rotation flat
5 Flat face plunger with anti-rotation flat
6 60° plunger with anti-rotation flat

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 360 32 8 Recommended Maximum watts dissipated by
LINEAR Tubular

when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 470 120 32 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 10 20 40 100 aluminium plate measuring 102 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 1166 1649 2332 3688
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 61.5 N @ 20°C
awg Resistance # VDC VDC VDC VDC 60°: 29.4 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 197.3 g
23 1.96 536 4.4 6.3 8.9 14.0
24 2.69 600 5.2 7.3 10.4 16.4 Plunger Weight 45.4 g
25 4.89 840 7.0 9.9 14.0 22.0 Dimensions See page F36
26 8.70 1117 9.4 13.3 18.8 29.7
27 11.50 1260 10.7 15.2 21.0 34.0
28 19.20 1645 13.8 19.6 28.0 44.0
29 31.20 2104 17.7 25.0 35.0 56.0 How to Order
30 49.60 2646 22.0 31.0 45.0 70.0
31 77.40 3280 28.0 39.0 56.0 88.0 Add the plunger configuration number and the coil
32 119.00 4026 35.0 49.0 69.0 109.0 awg number to the part number (for example: to order
33 202.00 5317 45.0 64.0 90.0 142.0 a unit with a 60° plunger rated for 21 VDC at 25% duty
1
Continuously pulsed at stated watts and duty cycle cycle, specify 195226-227.
2
Single pulse at stated watts (with coil at ambient room Please see www.ledex.com (click on Stock Products
temperature 20°C) tab) for our list of stock products available through our
3
Other coil awg sizes available — please consult factory distributors.
4
Reference number of turns

All specifications subject to change without notice.

Ledex® Solenoids F24 www.ledex.com


STA® Pull Tubular Solenoids — 26 mm Dia. x 52 mm
Pull Tubular Solenoid – 26 mm dia. x 52 mm – Flat Face Plunger

Typical Force @ 20°C Typical Speed @ No Load, 20°C


126 50

10% Duty Cycle 100W 100% Duty Cycle 10W


108 25% Duty Cycle 40W 50% Duty Cycle 20W
50% Duty Cycle 20W 25% Duty Cycle 40W
100% Duty Cycle 10W 40 10% Duty Cycle 100W

90

Speed – ms
30
Force – N

72

54
20

36

10
18

0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5

Stroke – mm Stroke – mm

Pull Tubular Solenoid – 26 mm dia. x 52 mm – 60° Plunger

LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
54 50

10% Duty Cycle 100W 100% Duty Cycle 10W


25% Duty Cycle 40W 50% Duty Cycle 20W
45 50% Duty Cycle 20W 25% Duty Cycle 40W
100% Duty Cycle 10W 40 10% Duty Cycle 100W

36
Speed – ms

30
Force – N

27

20
18

10
9

0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 0 2.5 5.0 7.5 10.0 12.5 15.0 17.5

Stroke – mm Stroke – mm

All specifications subject to change without notice.

Ledex® Solenoids F25 www.ledex.com


STA® Push Tubular Solenoids — 26 mm Dia. x 52 mm
Part Number: 195227 - X XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant
Coil AWG Number
(from performance chart below)

Plunger Configurations and anti-rotation flat on mounting


1 Flat face plunger without anti-rotation flat
2 60° plunger without anti-rotation flat
5 Flat face plunger with anti-rotation flat
6 60° plunger with anti-rotation flat

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 360 32 8 Recommended Maximum watts dissipated by
LINEAR Tubular

when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 470 120 32 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 10 20 40 100 aluminium plate measuring 102 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 1166 1649 2332 3688
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 52.6 N @ 20°C
awg Resistance # VDC VDC VDC VDC
60°: 28.9 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 190.8 g
23 1.96 536 4.4 6.3 8.9 14.0
24 2.69 600 5.2 7.3 10.4 16.4 Plunger Weight 33.7 g
25 4.89 840 7.0 9.9 14.0 22.0 Dimensions See page F36
26 8.70 1117 9.4 13.3 18.8 29.7
27 11.50 1260 10.7 15.2 21.0 34.0
28 19.20 1645 13.8 19.6 28.0 44.0
29 31.20 2104 17.7 25.0 35.0 56.0 How to Order
30 49.60 2646 22.0 31.0 45.0 70.0
31 77.40 3280 28.0 39.0 56.0 88.0 Add the plunger configuration number and the coil
32 119.00 4026 35.0 49.0 69.0 109.0 awg number to the part number (for example: to order
33 202.00 5317 45.0 64.0 90.0 142.0 a unit with a 60° plunger rated for 21 VDC at 25% duty
1
Continuously pulsed at stated watts and duty cycle cycle, specify 195227-227.
2
Single pulse at stated watts (with coil at ambient room Please see www.ledex.com (click on Stock Products
temperature 20°C) tab) for our list of stock products available through our
3
Other coil awg sizes available — please consult factory distributors.
4
Reference number of turns

All specifications subject to change without notice.

Ledex® Solenoids F26 www.ledex.com


STA® Push Tubular Solenoids — 26 mm Dia. x 52 mm
Push Tubular Solenoid – 26 mm dia. x 52 mm – Flat Face Plunger

Typical Force @ 20°C Typical Speed @ No Load, 20°C


126 50

10% Duty Cycle 100W 100% Duty Cycle 10W


108 25% Duty Cycle 40W 50% Duty Cycle 20W
50% Duty Cycle 20W 25% Duty Cycle 40W
100% Duty Cycle 10W 40 10% Duty Cycle 100W

90

Speed – ms
30
Force – N

72

54
20

36

10
18

0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5

Stroke – mm Stroke – mm

Push Tubular Solenoid – 26 mm dia. x 52 mm – 60° Plunger

LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
54 50

10% Duty Cycle 100W 100% Duty Cycle 10W


25% Duty Cycle 40W 50% Duty Cycle 20W
45 50% Duty Cycle 20W 25% Duty Cycle 40W
100% Duty Cycle 10W 40 10% Duty Cycle 100W

36
Speed – ms

30
Force – N

27

20
18

10
9

0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 0 2.5 5.0 7.5 10.0 12.5 15.0 17.5

Stroke – mm Stroke – mm

All specifications subject to change without notice.

Ledex® Solenoids F27 www.ledex.com


Ledex® Size 125M Pull Tubular Solenoids — 32 mm Dia. x 57 mm
Part Number: 282366-0XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 390 60 18 Recommended Maximum watts dissipated by
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 510 160 45 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 13 26 52 130 aluminium plate measuring 127 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 1500 2121 3000 4743
Coil Resistance ±5% tolerance
Coil Data
Holding Force 40.0 N @ 20°C
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Weight 295 g
23 3.52 780 6.8 9.6 13.6 22.0 Dimensions See page F37
24 6.04 1056 8.6 12.2 17.2 27.0
25 8.47 1176 10.9 15.4 22.0 34.0
26 14.10 1540 13.8 19.5 28.0 44.0
27 22.50 1970 17.3 24.0 35.0 55.0
28 36.10 2484 22.0 31.0 44.0 69.0
LINEAR Tubular

29 55.10 3060 27.0 38.0 54.0 86.0 How to Order


30 88.10 3805 35.0 49.0 70.0 110.0 Add the coil awg number (0XX) to the part number (for
31 147.00 5044 44.0 62.0 88.0 139.0
32 214.00 5992 54.0 76.0 107.0 170.0 example: to order a 25% duty cycle unit rated at 35 VDC,
33 354.00 7744 69.0 98.0 138.0 218.0 specify 282366-027).
1
Continuously pulsed at stated watts and duty cycle Please see www.ledex.com (click on Stock Products
2
Single pulse at stated watts (with coil at ambient room tab) for our list of stock products available through our
temperature 20°C) distributors.
3
Other coil awg sizes available — please consult factory
4
Reference number of turns

Size 125M Pull — Typical Force @ 20°C Size 125M Pull — Typical Speed @ No Load, 20°C

88 80
10% Duty Cycle 130 W
25% Duty Cycle 52 W
50% Duty Cycle 26 W 100% Duty Cycle 13 W
66 100% Duty Cycle 13 W 60 50% Duty Cycle 26 W
25% Duty Cycle 52 W
10% Duty Cycle 130 W
Force - N

Time - ms

44 40

22
20

0 2.5 5.0 7.5 10.0 12.5 15.0 17.5


0 5.0 10.0 15.0 20.0 25.0
Stroke - mm
Stroke - mm

All specifications subject to change without notice.

Ledex® Solenoids F28 www.ledex.com


Ledex® Size 150M Pull Tubular Solenoids — 38 mm Dia. x 64 mm
Part Number: 282367-0XX All catalogue products manufactured after
April 1, 2006 are RoHS Compliant

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 420 100 25 Recommended Maximum watts dissipated by
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 570 252 75 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 17 34 68 170 aluminium plate measuring 152 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 1800 2546 3600 5692
Coil Resistance ±5% tolerance
Coil Data
Holding Force 64.5 N at 20°C
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Weight 481.8 g
23 5.58 1030 9.8 13.9 19.7 31.0 Dimensions See page F37
24 9.30 1344 12.4 17.6 25.0 39.0
25 14.90 1712 15.7 22.0 31.0 50.0
26 24.00 2180 19.9 28.0 40.0 63.0
27 36.90 2680 25.0 35.0 50.0 79.0
28 58.40 3322 32.0 45.0 63.0 100.0

LINEAR Tubular
29 87.50 4008 39.0 56.0 79.0 124.0 How to Order
30 148.00 5292 50.0 71.0 101.0 159.0
31 224.00 6360 63.0 90.0 127.0 200.0 Add the coil awg number (0XX) to the part number (for
32 344.00 7956 78.0 110.0 155.0 246.0 example: to order a 25% duty cycle unit rated at 50 VDC,
33 554.00 10070 100.0 141.0 199.0 315.0 specify 282367-027).
1
Continuously pulsed at stated watts and duty cycle Please see www.ledex.com (click on Stock Products
2
Single pulse at stated watts (with coil at ambient room tab) for our list of stock products available through our
temperature 20°C) distributors.
3
Other coil awg sizes available — please consult factory
4
Reference number of turns

Size 150M Pull — Typical Force @ 20°C Size 150M Pull — Typical Speed @ No Load, 20°C

88 80

10% Duty Cycle 170W


25% Duty Cycle 68W 100% Duty Cycle 17W
50% Duty Cycle 34W 50% Duty Cycle 34W
66 100% Duty Cycle 17W 60
25% Duty Cycle 68W
10% Duty Cycle 170W
Force - N

Time - ms

44 40

22 20

0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 0 5.0 10.0 15.0 20.0 25.0

Stroke - mm Stroke - mm

All specifications subject to change without notice.

Ledex® Solenoids F29 www.ledex.com


Ledex® Size 175M Pull Tubular Solenoids — 44 mm Dia. x 120 mm
Part Number: 196675-0XX Class 180 H UL Recognised All catalogue products manufactured after
Coil Insulation System April 1, 2006 are RoHS Compliant

UL File No. E131577

Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 882 209 54 Recommended Maximum watts dissipated by
when pulsed continuously1 Minimum Heat Sink solenoid a re based on an unrestricted
Maximum ON Time (sec) ∞ 1,200 528 162 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 20 40 80 200 aluminium plate measuring 254 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 2923 4133 5844 9238
Coil Resistance ±5% tolerance
Coil Data
Holding Force 80.1 N @ 20°C
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Weight 1.02 kg
23 14.60 2544 17.1 24.2 34.2 54.0 Dimensions See page F38
24 23.30 3204 21.6 30.5 43.2 68.3
25 36.40 3990 27.0 38.2 54.0 85.3
26 56.20 4906 33.5 47.4 67.1 106.0
27 95.30 6474 43.7 61.7 87.3 138.1
28 142.90 7798 53.5 75.6 106.9 169.1
LINEAR Tubular

29 231.80 9952 68.1 96.3 136.2 215.3 How to Order


30 368.40 12510 85.8 121.4 171.7 271.4
31 575.40 15520 107.3 151.7 214.6 339.2 Add the coil awg number (0XX) to the part number (for
32 940.20 19895 137.1 193.9 274.3 433.6 example: to order a 25% duty cycle unit rated at 87 VDC,
33 1,425.00 24125 168.8 238.7 337.6 533.9 specify 196675-027).
1
Continuously pulsed at stated watts and duty cycle Please see www.ledex.com (click on Stock Products
2
Single pulse at stated watts (with coil at ambient room tab) for our list of stock products available through our
temperature 20°C) distributors.
3
Other coil awg sizes available — please consult factory
4
Reference number of turns

Size 175M Pull — Typical Force @ 20°C Size 175M Pull — Typical Speed @ No Load, 20°C
110 140
10% Duty Cycle 200W 100% Duty Cycle 20W
25% Duty Cycle 80W 50% Duty Cycle 40W
120 25% Duty Cycle 80W
88 50% Duty Cycle 40W
100% Duty Cycle 20W 10% Duty Cycle 200W
100
Time - ms

66
Force - N

80

44 60

40
22
20

0 12.5 25.0 37.5 50.0 62.5 0 12.5 25.0 37.5 50.0 62.5

Stroke - mm Stroke - mm

Force values for reference only. All specifications subject to change without notice.

Ledex® Solenoids F30 www.ledex.com


Ledex® Tubular Solenoids Dimensions
mm

STA® Series Pull — 13 mm Dia. x 14 mm

28.58 R Min.

Ø1.57 / 1.65 Thru

3.86 ± 0.30 Flat


3.18 ± 0.30 14.27 ± 0.38 13.97 Max. Ø13.20 Max.

Ø4.70 ± 0.08 Ø4.70 ± 0.08 Ø1.98 Ref.


6.35 ± 0.25
6.35 ± 0.030

1.57

M10 x 0.75

Mounting Nut: 2.3 thick x 12.7 flats. 250 mm min.


Shipped as loose item. 0.20 mm2
PVC

LINEAR Tubular
STA® Series Magnetic Latching Pull — 13 mm Dia. x 16 mm

28.58 R Min.

Ø1.57 / 1.65 Thru

3.18 ± 0.254 14.27 ± 0.38 15.75 Max.

13.21 Max.
6.35 ± 0.25
Ø4.70 ± 0.08

Red
1.57

6.35 ± 0.254 Black


M10 x 0.75 250 mm min.
0.20 mm2
PVC

STA® Series Push — 13 mm Dia. x 14 mm

3.86 ± 0.30 Flat 12.70 ± 0.38 13.97 Max. Ø2.77 Max.

Ø13.21 Max.
6.35 ± 0.25

Ø1.57 ± 0.08

M10 x 0.75
250 mm min.
Mounting Nut: 2.3 thick x 12.7 flats. 0.20 mm2
Shipped as loose item. PVC

All solenoids are illustrated in energised state All specifications subject to change without notice.

Ledex® Solenoids F31 www.ledex.com


Ledex® Tubular Solenoids Dimensions
mm

STA® Series Pull — 13mm Dia. x 27 mm

28.6 R min

3.18 ± 0.30 Ø2.05 / 2.15


Ø13.21
Ø4.70 ± 0.08 14.29 26.67 max max
± 0.38
6.35 ± 0.30 Ø1.98
max.
6.35 ± 0.3
LINEAR Tubular

2.1 ± 0.3
M10 x 0.75

3.86 250 mm min.,


Mounting nut shipped loose. 0.20 mm2
PVC

STA® Series Push — 13 mm Dia. x 27 mm

Ø13.21 19.05 26.67 max 2.77 max


max ± 0.38
6.35 ± 0.30

1.59 ± 0.08
M10 x 0.75
3.86
Mounting nut shipped loose. 250 mm min.,
0.20 mm2
PVC

All solenoids are illustrated in energised state All specifications subject to change without notice.

Ledex® Solenoids F32 www.ledex.com


Ledex® Tubular Solenoids Dimensions
mm

STA® Series Pull — 13 mm Dia. x 52 mm

28.58 R min
Chamfer 0.13/0.38
2.36 ± 0.25 Ø2.05/2.15 thru
Ø13.21
13.46 ± 0.38 52.07 max max

6.35 ± 0.30 Ø1.98


3.96 ± 0.25 dia. ref

LINEAR Tubular
Plunger 1.59
Ø5.16 ± 0.08
Without
Anti-Rotation Flat
M10 x 0.75
250 mm min.
20.0 mm2
3.86 PVC
Mounting Nut: 2.3 thick x 12.7 flats.
Shipped as loose item.

Plunger
Ø5.16 ± 0.08
With
Anti-Rotation Flat

All solenoids are illustrated in energised state All specifications subject to change without notice.

Ledex® Solenoids F33 www.ledex.com


Ledex® Tubular Solenoids Dimensions
mm

STA® Series Pull — 20 mm Dia. x 40 mm

28.6 R min

4.76 ± 0.30 Ø2.5 / 2.6


19.05 Ø19.56
Ø7.82 ± 0.08 39.37 max max
± 0.38
9.52 ± 0.30 Ø2.29 ref
9.5 ± 0.3
LINEAR Tubular

2.5 ± 0.3
M14 x 1.5

5.97
Mounting nut shipped loose.
250 mm min.,
0.20 mm2
PVC

STA® Series Push — 20 mm Dia. x 40 mm

28.58 39.37 max 3.56 max


Ø19.56 ± 0.38
max
9.52 ± 0.30

2.39 ± 0.08

M14 x 1.5
5.97
Mounting nut shipped loose.
250 mm min.,
0.20 mm2
PVC

All solenoids are illustrated in energised state All specifications subject to change without notice.

Ledex® Solenoids F34 www.ledex.com


Ledex® Tubular Solenoids Dimensions
mm

STA® Series Pull — 26 mm dia. x 30 mm

28.58 R min
Chamfer 0.51/0.76 x 45° ±5°

Ø3.05/3.15 thru
3.96 ± 0.25 Ø25.91
19.81 29.85 max
± 0.38 max
Plunger 9.52 ± 0.25
Ø11.10 ± 0.08

LINEAR Tubular
11.90 ± 0.25

4.75 ± 0.25 Ø2.18 ref

Without M20 x 1.5


Anti-Rotation Flat

250 mm min.
Plunger 0.20 mm2, PVC
Ø11.10 ± 0.08

Mounting Nut: 4.1 thick x 22.2 flats.


Shipped as loose item.

7.92

With
Anti-Rotation Flat

Ledex® Solenoids F35 www.ledex.com


Ledex® Tubular Solenoids Dimensions
mm

STA® Series Pull — 26 mm Dia. x 52 mm

28.58 R min

4.76 ± 0.30 Ø3.05 / 3.15


Ø25.91
19.05 52.07 max max
Ø10.95 ± 0.08 ± 0.38
9.52 ± 0.30 Ø3.97
ref
9.5 ± 0.3

3.1 ± 0.3
LINEAR Tubular

M20 x 1.5
7.92
Mounting nut shipped loose.
250 mm min.,
0.20 mm2
PVC

STA® Series Push — 26 mm Dia. x 52 mm

28.58 52.07 max 3.56 max


± 0.38
Ø25.91
max 9.52 ± 0.30

3.18 ± 0.08
M20 x 1.5
7.92
Mounting nut shipped loose.
250 mm min.,
0.20 mm2
PVC

All solenoids are illustrated in energised state All specifications subject to change without notice.

Ledex® Solenoids F36 www.ledex.com


Ledex® Tubular Solenoids Dimensions
mm

Ledex® Size 125M Pull — 32 mm Dia. x 57 mm Ledex® Size 150M Pull — 38 mm Dia. x 64 mm

18.237 ± 0.381 21.412 ± 0.381


1.473 1.473

16.662
16.662 38.1 ± 0.381
42.062
42.062 31.75 ± 0.381 max 33.325
max 33.325

Ø3.657 ± 0.051, 4 holes


Ø3.657 ± 0.051, 4 holes
Ø15.875 ± 0.762 4.749

Ø12.7 ± 0.762 4.749 9.5 ± 0.3

9.5 ± 0.3 Ø3.05 /3.15 4.0 ± 0.3 7.925 ± 0.381


4.0 ± 0.3 7.925 ± 0.381
Ø3.05 / 3.15

LINEAR Tubular
17.856 ± 0.381

14.681 ± 0.381 Plunger stop

Plunger stop 29.362 63.5 ± 0.787

29.362 57.15 ± 0.787

250 mm min.,
0.34 mm2
PVC
250 mm min.,
0.34 mm2
PVC

All solenoids are illustrated in energised state All specifications subject to change without notice.

Ledex® Solenoids F37 www.ledex.com


Ledex® Tubular Solenoids Dimensions
mm

Ledex® Size 175M Pull — 44 mm Dia. x 120 mm

24.77 ± 0.38 ref

4.27
ref

16.66
42.06 44.45 ± 0.38
max 33.33

Ø15.19 ± 0.76 4.75

9.5 ± 0.3
LINEAR Tubular

4.0 ± 0.3 7.93 ± 0.38


Ø3.05 / 3.15
Non-magnetic
air gap spacer
29.36

71.45 ± 0.25

119.56
max

29.36

M4 x 0.7
8x
250 mm min.,
0.34 mm2
(Teflon)

All solenoids are illustrated in energised state All specifications subject to change without notice.

Ledex® Solenoids F38 www.ledex.com