Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Linear Solenoids
45
27
Force – N
18
Stroke – mm
24
16
Force – N
12
Ledex® Tubular Solenoids
■ STA® Series has enhanced ■ Strokes up to 64 mm
design features and
improved performance ■ Life rating of 25 million
actuations for STA designs
■ Push and pull models
LINEAR Tubular
ranging from #23 up to #37 come apart.
An impact cushion
to accommodate your input Both push and pull A Flat Face
(180°) made of resilient non-
power. models offer a built-in
magnetic material absorbs
Refer to the individual combination air gap
energy at the end of the
model specification spacer and plunger stop.
B. 60° Angle stroke. This cushion also
pages for coil wire awg This feature eliminates the
For longer strokes helps eliminate residual
recommendations. Many need for external E-rings
up to 19 mm, the 60° magnetism.
other coil awg sizes are and impact washers which
plunger offers the greatest Size 125M, 150M, and
available. Please feel free typically fail prematurely,
advantage over the flat 175M models are available
to contact our application as well as get in the
face plunger. with other plunger
engineering department way of your attached
configurations, in push
for availability. mechanisms.
type models, and with
All units are provided B 60°
other mountings. Please
Tubular Applications with 250 mm PVC lead
consult the factory as
The STA Series is wires as standard, and
tooling may apply.
particularly ideal for are rated for a maximum
applications where field coil temperature of 130°C.
service is prohibitive. Its UL-approved materials are A: Flat Face
C: 60° Cone
• Computer peripherals please consult the factory
• Industrial sewing for alternate materials
machines which are available in
• Automated teller some models. Mechanical Stroke
machines and electrical ratings may
• Blood analyzers also be affected. Other
• Gate mechanisms options include: special
• Packaging machinery plunger configurations,
• Door interlocks springs, special mounting
• Sorting machines features, and anti-
• Glue dispensers rotation flats on mounting
• Laboratory equipment bushings. Please consult
• Business machines the factory with details
LINEAR Tubular
engineers.
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) ∞ 50 5 2 Recommended Maximum watts dissipated by
LINEAR Tubular
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 140 30 8 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 3 6 12 30 aluminium plate measuring 51 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 268 379 536 847
Coil Resistance ±5% tolerance
Coil Data
Weight 14.5 g
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Dimensions See page F31
27 0.48 108 1.2 1.7 2.4 3.8
28 0.67 123 1.5 2.1 2.9 4.6
29 1.33 184 1.9 2.7 3.9 6.1
30 1.80 204 2.4 3.3 4.7 7.5
31 3.33 290 3.1 4.4 6.2 9.7
32 4.57 325 3.8 5.3 7.5 11.9
33 7.80 432 4.8 6.8 9.7 15.3 How to Order
34 13.10 567 6.2 8.8 12.4 19.6 Add the plunger configuration, anti-rotation flat
35 17.80 630 7.6 11.0 15.0 24.0
36 29.05 808 9.6 14.0 19.0 30.0 number, and the coil awg number to the part number
37 45.70 1008 12.2 17.0 24.0 38.0 (for example: to order a unit with a 60° plunger
1
Continuously pulsed at stated watts and duty cycle configuration without an anti-rotation flat rated for 4.7
2
Single pulse at stated watts (with coil at ambient room VDC at 25% duty cycle, specify 195220-230.
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.
Speed – ms
6.6 50% Duty Cycle
Force - N
4.4
8
2.2
4
LINEAR Tubular
0 0.6 1.2 1.8 2.4 0 0.5 1.0 1.5 2.0 2.5
Stroke - mm Stroke – mm
Latch: A+ B-
Unlatch: A- B+
B
(Black)
LINEAR Tubular
Performance Specifications
Unlatched Operation Pull
Maximum Duty Cycle Voltage 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) n/a 50 5 2 Recommended Maximum watts dissipated by solenoid
when pulsed continuously1 Minimum Heat Sink are based on an unrestricted flow of air
at 2 0°C, with solenoid mounted on the
Watts (@ 20°C) 3 6 12 30 equivalent of an aluminium plate
Ampere Turns (@ 20°C) 268 379 536 847 measuring 51 mm square by 3.2 mm
Coil Data thick
Unlatch Voltage See schematic and coil data
awg Resistance # Unlatched VDC VDC VDC
(0XX)2 (@20°C) Turns3 VDC (Nom) (Nom) (Nom) Magnet Hold Force 2 N (with return spring)
Coil Insulation Class "B"; 130°C max. temperature
27 0.48 108 1.2 1.7 2.4 3.8 standard. Other temperature classes are
28 0.67 123 1.5 2.1 2.9 4.6 available.
29 1.33 184 1.9 2.7 4.0 6.1 Spring Force 0.38 N/mm; 1.2 N latched position
30 1.80 204 2.4 3.3 4.7 7.5 Weight 14.7 g
31 3.33 290 3.1 4.4 6.2 9.7 Plunger Weight 2.6 g
32 4.57 325 3.8 5.3 7.5 11.9
Dimensions See page F31
33 7.80 432 4.8 6.8 9.7 15.3
34 13.10 567 6.2 8.8 12.4 20.0
35 17.80 630 7.6 11.0 15.0 24.0
36 29.05 808 9.6 14.0 19.0 30.0
37 45.70 1008 12.2 17.0 24.0 38.0
1
Continuously pulsed at stated watts and duty cycle How to Order
2
Other coil awg sizes available — please consult factory Add the plunger configuration, anti-rotation flat
3
Reference number of turns number, and the coil awg number to the part number
(for example: to order a 60° plunger unit without an anti-
rotation flat, rated for 4.7 VDC at 25% duty cycle, specify
151094-230.
Please see www.ledex.com (click on Stock Products
tab) for our list of stock products available through our
distributors.
6.5
3.9
2.6
1.3
LINEAR Tubular
0
0 0.6 1.2 1.8 2.4 3.0 3.6
Stroke - mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) ∞ 50 5 2 Recommended Maximum watts dissipated by
LINEAR Tubular
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 140 30 8 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 3 6 12 30 aluminium plate measuring 51 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 268 379 536 847
Coil Resistance ±5% tolerance
Coil Data
Weight 14.5 g
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Dimensions See page F31
27 0.48 108 1.2 1.7 2.4 3.8
28 0.67 123 1.5 2.1 2.9 4.6
29 1.33 184 1.9 2.7 3.9 6.1
30 1.80 204 2.4 3.3 4.7 7.5
31 3.33 290 3.1 4.4 6.2 9.7
32 4.57 325 3.8 5.3 7.5 11.9
33 7.80 432 4.8 6.8 9.7 15.3 How to Order
34 13.10 567 6.2 8.8 12.4 19.6 Add the plunger configuration, anti-rotation flat
35 17.80 630 7.6 11.0 15.0 24.0 number, and the coil awg number to the part number
36 29.05 808 9.6 14.0 19.0 30.0
37 45.70 1008 12.2 17.0 24.0 38.0 (for example: to order a unit with a 60° plunger
configuration without an anti-rotation flat rated for 4.7
1
Continuously pulsed at stated watts and duty cycle
VDC at 25% duty cycle, specify 195221-230.
2
Single pulse at stated watts (with coil at ambient room
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.
Speed – ms
Force - N
2.4 12
1.6 8
0.8 4
0
0 0.6 1.2 1.8 2.4 0 0.5 1.0 1.5 2.0 2.5
LINEAR Tubular
Stroke - mm Stroke – mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) ∞ 50 5 2 Recommended Maximum watts dissipated by solenoid
LINEAR Tubular
when pulsed continuously1 Minimum Heat Sink are based on an unrestricted flow of
Maximum ON Time (sec) ∞ 140 30 8 air at 20°C, with solenoid mounted on
for single pulse2 the equivalent of an aluminium plate
Watts (@ 20°C) 4 8 16 40 measuring 51 mm square by 3.2 mm
thick
Ampere Turns (@ 20°C) 497 704 994 1573
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 5 .3 N @ 20°C
awg Resistance # VDC VDC VDC VDC 60°: 4.0 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 24.7 g
27 1.43 306 2.4 3.4 4.8 7.6
28 1.95 342 2.8 3.9 5.6 8.8 Plunger Weight 4.5 g
29 3.84 508 3.9 5.5 7.8 12.4 Dimensions See page F32
30 5.29 572 4.6 6.5 9.2 14.5
31 9.56 795 6.2 8.8 12.4 19.6
32 16.54 1068 8.1 11.5 16.3 25.7
33 22.60 1194 9.5 13.4 19.0 30.0 How to Order
34 37.41 1547 12.2 17.3 24.0 39.0 Add the plunger configuration, anti-rotation flat
35 60.71 1976 15.6 22.0 31.0 49.0 number, and the coil awg number to the part number
36 96.19 2475 19.6 28.0 39.0 62.0
37 141.93 3060 23.8 33.7 47.6 75.3 (for example: to order a unit with a 60° plunger
configuration without an anti-rotation flat rated for 4.8
1
Continuously pulsed at stated watts and duty cycle
VDC at 25% duty cycle, specify 195222-227.
2
Single pulse at stated watts (with coil at ambient room
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.
8.0 16
Speed – ms
Force – N
6.0 12
4.0 8
2.0 4
0 1.25 2.5 3.75 5.0 6.25 0 1.25 2.5 3.75 5.0 6.25
Stroke – mm Stroke – mm
LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
8.0 60
40
Speed – ms
Force – N
4.0 30
20
2.0
10
0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5
Stroke – mm Stroke – mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) ∞ 50 5 2 Recommended Maximum watts dissipated by
LINEAR Tubular
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 140 30 8 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 4 8 16 40 aluminium plate measuring 51 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 497 704 994 1573
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 4.5 N @ 20°C
awg Resistance # VDC VDC VDC VDC 60°: 3.2 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 25.2 g
27 1.43 306 2.4 3.4 4.8 7.6
28 1.95 342 2.8 3.9 5.6 8.8 Plunger Weight 3.1 g
29 3.84 508 3.9 5.5 7.8 12.4 Dimensions See page F32
30 5.29 572 4.6 6.5 9.2 14.5
31 9.56 795 6.2 8.8 12.4 19.6
32 16.54 1068 8.1 11.5 16.3 25.7
33 22.60 1194 9.5 13.4 19.0 30.0 How to Order
34 37.41 1547 12.2 17.3 24.0 39.0
35 60.71 1976 15.6 22.0 31.0 49.0 Add the plunger configuration, anti-rotation flat
36 96.19 2475 19.6 28.0 39.0 62.0 number and the coil awg number to the part number
37 141.93 3060 23.8 33.7 47.6 75.3 (for example: to order a unit with a 60° plunger
1
Continuously pulsed at stated watts and duty cycle configuration without anti-rotation rated for 4.8 VDC at
2
Single pulse at stated watts (with coil at ambient room 25% duty cycle, specify 195223-227.
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.
16
Speed – ms
Force – N
4 12
0 1.25 2.5 3.75 5.0 6.25 0 1.25 2.5 3.75 5.0 6.25
Stroke – mm Stroke – mm
LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
8 60
40
Speed – ms
Force – N
4 30
20
10
0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5
Stroke – mm Stroke – mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 500 VRMS
Maximum ON Time (sec) ∞ 62 18 5 Recommended Maximum watts dissipated by
LINEAR Tubular
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 179 59 15 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 4.8 9.6 19.2 48 aluminium plate measuring 51 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 762 1078 1525 2410
Coil Resistance ±5% tolerance
Coil Data
Holding Force 60°: 3.9 N at 20°C
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Weight 42.5 g
27 2.03 456 3.1 4.4 6.2 9.9 Plunger Weight 8.5 g
28 4.57 765 4.7 6.6 9.4 14.8 Dimensions See page F33
29 6.30 855 5.5 7.8 11.0 17.4
30 12.34 1276 7.7 10.9 15.4 24.3
31 17.70 1430 9.2 13.0 18.4 29.1
32 30.45 1985 12.1 17.1 24.2 38.2
33 45.10 2350 14.7 20.8 29.4 46.5
34 72.70 2998 18.7 26.4 37.4 59.1
35 118.71 3850 23.9 33.8 47.7 75.5
36 173.00 4510 28.8 40.8 57.6 91.1 How to Order
1
Continuously pulsed at stated watts and duty cycle Add the plunger configuration and the coil awg
2
Single pulse at stated watts (with coil at ambient room number to the part number (for example: to order a unit
temperature 20°C) with a 60° plunger configuration without an anti-rotation
3
Other coil awg sizes available — please consult factory flat rated for 6.2 VDC at 25% duty cycle, specify 153092-
4
Reference number of turns 227.
Please see www.ledex.com (click on Stock Products
tab) for our list of stock products available through our
North American distributors.
Stroke – mm
LINEAR Tubular
Typical Speed @ No Load, 20°C
60
30
20
10
Stroke – mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 230 25 6 Recommended Maximum watts dissipated by
LINEAR Tubular
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 265 63 15 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
aluminium plate measuring 76 mm
Watts (@ 20°C) 7 14 28 70
square by 3.2 mm thick
Ampere Turns (@ 20°C) 855 1200 1700 2700
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 23.3 N @ 20°C
awg Resistance # VDC VDC VDC VDC 60°: 12.8 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 83.6 g
24 1.10 330 2.7 3.8 5.6 8.8
Plunger Weight 20.1 g
25 2.13 488 3.9 5.5 7.7 12.2
26 2.90 544 4.5 6.4 9.0 14.2 Dimensions See page F34
27 5.27 760 6.1 8.6 12.1 19.2
28 9.15 1026 8.0 11.3 16.0 25.0
29 12.50 1146 9.4 13.2 18.7 30.0
30 20.70 1491 12.0 17.0 24.0 38.0 How to Order
31 33.60 1904 15.0 22.0 31.0 48.0
32 53.50 2394 19.4 27.0 39.0 61.0 Add the plunger number and the coil awg number to
33 83.50 2970 24.0 34.0 48.0 76.0 the part number (for example: to order a unit with a 60°
1
Continuously pulsed at stated watts and duty cycle plunger configuration without an anti-rotation flat rated
2
Single pulse at stated watts (with coil at ambient room for 12.1 VDC at 25% duty cycle, specify 195224-227.
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.
Speed – ms
27 30
Force – N
18 20
9 10
0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5
Stroke – mm Stroke – mm
LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
24 50
16
Speed – ms
30
Force – N
12
20
9
10
4
0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 0 2.5 5.0 7.5 10.0 12.5 15.0 17.5
Stroke – mm Stroke – mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 230 25 6 Recommended Maximum watts dissipated by
LINEAR Tubular
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 265 63 15 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 7 14 28 70 aluminium plate measuring 76 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 855 1200 1700 2700
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 22.0 N @ 20°C
awg Resistance # VDC VDC VDC VDC 60°: 12.7 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 87.3 g
24 1.10 330 2.7 3.8 5.6 8.8
25 2.13 488 3.9 5.5 7.7 12.2 Plunger Weight 15.0 g
26 2.90 544 4.5 6.4 9.0 14.2 Dimensions See page F34
27 5.27 760 6.1 8.6 12.1 19.2
28 9.15 1026 8.0 11.3 16.0 25.0
29 12.50 1146 9.4 13.2 18.7 30.0
30 20.70 1491 12.0 17.0 24.0 38.0 How to Order
31 33.60 1904 15.0 22.0 31.0 48.0
32 53.50 2394 19.4 27.0 39.0 61.0 Add the plunger number and the coil awg number to
33 83.50 2970 24.0 34.0 48.0 76.0 the part number (for example: to order a unit with a 60°
1
Continuously pulsed at stated watts and duty cycle plunger configuration without an anti-rotation flat rated
2
Single pulse at stated watts (with coil at ambient room for 12.1 VDC at 25% duty cycle, specify 195225-227.
temperature 20°C) Please see www.ledex.com (click on Stock Products
3
Other coil awg sizes available — please consult factory tab) for our list of stock products available through our
4
Reference number of turns distributors.
Speed – ms
30
Force – N
18
20
9
10
0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5
Stroke – mm Stroke – mm
LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
24 50
10% Duty Cycle 70W 100% Duty Cycle 7W
25% Duty Cycle 28W 50% Duty Cycle 14W
50% Duty Cycle 14W 25% Duty Cycle 28W
20 100% Duty Cycle 7W
40 10% Duty Cycle 70W
16
Speed – ms
30
Force – N
12
20
8
10
4
0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 0 2.5 5.0 7.5 10.0 12.5 15.0 17.5
Stroke – mm Stroke – mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 104 24 8 Recommended Maximum watts dissipated by
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 187 55 18 flow of air at 20°C, with solenoid
LINEAR Tubular
54
36
Force – N
27
18
LINEAR Tubular
Stroke – mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 360 32 8 Recommended Maximum watts dissipated by
LINEAR Tubular
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 470 120 32 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 10 20 40 100 aluminium plate measuring 102 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 1166 1649 2332 3688
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 61.5 N @ 20°C
awg Resistance # VDC VDC VDC VDC 60°: 29.4 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 197.3 g
23 1.96 536 4.4 6.3 8.9 14.0
24 2.69 600 5.2 7.3 10.4 16.4 Plunger Weight 45.4 g
25 4.89 840 7.0 9.9 14.0 22.0 Dimensions See page F36
26 8.70 1117 9.4 13.3 18.8 29.7
27 11.50 1260 10.7 15.2 21.0 34.0
28 19.20 1645 13.8 19.6 28.0 44.0
29 31.20 2104 17.7 25.0 35.0 56.0 How to Order
30 49.60 2646 22.0 31.0 45.0 70.0
31 77.40 3280 28.0 39.0 56.0 88.0 Add the plunger configuration number and the coil
32 119.00 4026 35.0 49.0 69.0 109.0 awg number to the part number (for example: to order
33 202.00 5317 45.0 64.0 90.0 142.0 a unit with a 60° plunger rated for 21 VDC at 25% duty
1
Continuously pulsed at stated watts and duty cycle cycle, specify 195226-227.
2
Single pulse at stated watts (with coil at ambient room Please see www.ledex.com (click on Stock Products
temperature 20°C) tab) for our list of stock products available through our
3
Other coil awg sizes available — please consult factory distributors.
4
Reference number of turns
90
Speed – ms
30
Force – N
72
54
20
36
10
18
0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5
Stroke – mm Stroke – mm
LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
54 50
36
Speed – ms
30
Force – N
27
20
18
10
9
0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 0 2.5 5.0 7.5 10.0 12.5 15.0 17.5
Stroke – mm Stroke – mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 360 32 8 Recommended Maximum watts dissipated by
LINEAR Tubular
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 470 120 32 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 10 20 40 100 aluminium plate measuring 102 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 1166 1649 2332 3688
Coil Resistance ±5% tolerance
Coil Data
Holding Force Flat Face: 52.6 N @ 20°C
awg Resistance # VDC VDC VDC VDC
60°: 28.9 N @ 20°C
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom)
Weight 190.8 g
23 1.96 536 4.4 6.3 8.9 14.0
24 2.69 600 5.2 7.3 10.4 16.4 Plunger Weight 33.7 g
25 4.89 840 7.0 9.9 14.0 22.0 Dimensions See page F36
26 8.70 1117 9.4 13.3 18.8 29.7
27 11.50 1260 10.7 15.2 21.0 34.0
28 19.20 1645 13.8 19.6 28.0 44.0
29 31.20 2104 17.7 25.0 35.0 56.0 How to Order
30 49.60 2646 22.0 31.0 45.0 70.0
31 77.40 3280 28.0 39.0 56.0 88.0 Add the plunger configuration number and the coil
32 119.00 4026 35.0 49.0 69.0 109.0 awg number to the part number (for example: to order
33 202.00 5317 45.0 64.0 90.0 142.0 a unit with a 60° plunger rated for 21 VDC at 25% duty
1
Continuously pulsed at stated watts and duty cycle cycle, specify 195227-227.
2
Single pulse at stated watts (with coil at ambient room Please see www.ledex.com (click on Stock Products
temperature 20°C) tab) for our list of stock products available through our
3
Other coil awg sizes available — please consult factory distributors.
4
Reference number of turns
90
Speed – ms
30
Force – N
72
54
20
36
10
18
0 2.5 5.0 7.5 10.0 12.5 0 2.5 5.0 7.5 10.0 12.5
Stroke – mm Stroke – mm
LINEAR Tubular
Typical Force @ 20°C Typical Speed @ No Load, 20°C
54 50
36
Speed – ms
30
Force – N
27
20
18
10
9
0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 0 2.5 5.0 7.5 10.0 12.5 15.0 17.5
Stroke – mm Stroke – mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 390 60 18 Recommended Maximum watts dissipated by
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 510 160 45 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 13 26 52 130 aluminium plate measuring 127 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 1500 2121 3000 4743
Coil Resistance ±5% tolerance
Coil Data
Holding Force 40.0 N @ 20°C
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Weight 295 g
23 3.52 780 6.8 9.6 13.6 22.0 Dimensions See page F37
24 6.04 1056 8.6 12.2 17.2 27.0
25 8.47 1176 10.9 15.4 22.0 34.0
26 14.10 1540 13.8 19.5 28.0 44.0
27 22.50 1970 17.3 24.0 35.0 55.0
28 36.10 2484 22.0 31.0 44.0 69.0
LINEAR Tubular
Size 125M Pull — Typical Force @ 20°C Size 125M Pull — Typical Speed @ No Load, 20°C
88 80
10% Duty Cycle 130 W
25% Duty Cycle 52 W
50% Duty Cycle 26 W 100% Duty Cycle 13 W
66 100% Duty Cycle 13 W 60 50% Duty Cycle 26 W
25% Duty Cycle 52 W
10% Duty Cycle 130 W
Force - N
Time - ms
44 40
22
20
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 420 100 25 Recommended Maximum watts dissipated by
when pulsed continuously1 Minimum Heat Sink solenoid are based on an unrestricted
Maximum ON Time (sec) ∞ 570 252 75 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 17 34 68 170 aluminium plate measuring 152 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 1800 2546 3600 5692
Coil Resistance ±5% tolerance
Coil Data
Holding Force 64.5 N at 20°C
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Weight 481.8 g
23 5.58 1030 9.8 13.9 19.7 31.0 Dimensions See page F37
24 9.30 1344 12.4 17.6 25.0 39.0
25 14.90 1712 15.7 22.0 31.0 50.0
26 24.00 2180 19.9 28.0 40.0 63.0
27 36.90 2680 25.0 35.0 50.0 79.0
28 58.40 3322 32.0 45.0 63.0 100.0
LINEAR Tubular
29 87.50 4008 39.0 56.0 79.0 124.0 How to Order
30 148.00 5292 50.0 71.0 101.0 159.0
31 224.00 6360 63.0 90.0 127.0 200.0 Add the coil awg number (0XX) to the part number (for
32 344.00 7956 78.0 110.0 155.0 246.0 example: to order a 25% duty cycle unit rated at 50 VDC,
33 554.00 10070 100.0 141.0 199.0 315.0 specify 282367-027).
1
Continuously pulsed at stated watts and duty cycle Please see www.ledex.com (click on Stock Products
2
Single pulse at stated watts (with coil at ambient room tab) for our list of stock products available through our
temperature 20°C) distributors.
3
Other coil awg sizes available — please consult factory
4
Reference number of turns
Size 150M Pull — Typical Force @ 20°C Size 150M Pull — Typical Speed @ No Load, 20°C
88 80
Time - ms
44 40
22 20
0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 0 5.0 10.0 15.0 20.0 25.0
Stroke - mm Stroke - mm
Performance Specifications
Maximum Duty Cycle 100% 50% 25% 10% Dielectric Strength 1000 VRMS
Maximum ON Time (sec) ∞ 882 209 54 Recommended Maximum watts dissipated by
when pulsed continuously1 Minimum Heat Sink solenoid a re based on an unrestricted
Maximum ON Time (sec) ∞ 1,200 528 162 flow of air at 20°C, with solenoid
for single pulse2 mounted on the equivalent of an
Watts (@ 20°C) 20 40 80 200 aluminium plate measuring 254 mm
square by 3.2 mm thick
Ampere Turns (@ 20°C) 2923 4133 5844 9238
Coil Resistance ±5% tolerance
Coil Data
Holding Force 80.1 N @ 20°C
awg Resistance # VDC VDC VDC VDC
(0XX)3 (@20°C) Turns4 (Nom) (Nom) (Nom) (Nom) Weight 1.02 kg
23 14.60 2544 17.1 24.2 34.2 54.0 Dimensions See page F38
24 23.30 3204 21.6 30.5 43.2 68.3
25 36.40 3990 27.0 38.2 54.0 85.3
26 56.20 4906 33.5 47.4 67.1 106.0
27 95.30 6474 43.7 61.7 87.3 138.1
28 142.90 7798 53.5 75.6 106.9 169.1
LINEAR Tubular
Size 175M Pull — Typical Force @ 20°C Size 175M Pull — Typical Speed @ No Load, 20°C
110 140
10% Duty Cycle 200W 100% Duty Cycle 20W
25% Duty Cycle 80W 50% Duty Cycle 40W
120 25% Duty Cycle 80W
88 50% Duty Cycle 40W
100% Duty Cycle 20W 10% Duty Cycle 200W
100
Time - ms
66
Force - N
80
44 60
40
22
20
0 12.5 25.0 37.5 50.0 62.5 0 12.5 25.0 37.5 50.0 62.5
Stroke - mm Stroke - mm
Force values for reference only. All specifications subject to change without notice.
28.58 R Min.
1.57
M10 x 0.75
LINEAR Tubular
STA® Series Magnetic Latching Pull — 13 mm Dia. x 16 mm
28.58 R Min.
13.21 Max.
6.35 ± 0.25
Ø4.70 ± 0.08
Red
1.57
Ø13.21 Max.
6.35 ± 0.25
Ø1.57 ± 0.08
M10 x 0.75
250 mm min.
Mounting Nut: 2.3 thick x 12.7 flats. 0.20 mm2
Shipped as loose item. PVC
All solenoids are illustrated in energised state All specifications subject to change without notice.
28.6 R min
2.1 ± 0.3
M10 x 0.75
1.59 ± 0.08
M10 x 0.75
3.86
Mounting nut shipped loose. 250 mm min.,
0.20 mm2
PVC
All solenoids are illustrated in energised state All specifications subject to change without notice.
28.58 R min
Chamfer 0.13/0.38
2.36 ± 0.25 Ø2.05/2.15 thru
Ø13.21
13.46 ± 0.38 52.07 max max
LINEAR Tubular
Plunger 1.59
Ø5.16 ± 0.08
Without
Anti-Rotation Flat
M10 x 0.75
250 mm min.
20.0 mm2
3.86 PVC
Mounting Nut: 2.3 thick x 12.7 flats.
Shipped as loose item.
Plunger
Ø5.16 ± 0.08
With
Anti-Rotation Flat
All solenoids are illustrated in energised state All specifications subject to change without notice.
28.6 R min
2.5 ± 0.3
M14 x 1.5
5.97
Mounting nut shipped loose.
250 mm min.,
0.20 mm2
PVC
2.39 ± 0.08
M14 x 1.5
5.97
Mounting nut shipped loose.
250 mm min.,
0.20 mm2
PVC
All solenoids are illustrated in energised state All specifications subject to change without notice.
28.58 R min
Chamfer 0.51/0.76 x 45° ±5°
Ø3.05/3.15 thru
3.96 ± 0.25 Ø25.91
19.81 29.85 max
± 0.38 max
Plunger 9.52 ± 0.25
Ø11.10 ± 0.08
LINEAR Tubular
11.90 ± 0.25
250 mm min.
Plunger 0.20 mm2, PVC
Ø11.10 ± 0.08
7.92
With
Anti-Rotation Flat
28.58 R min
3.1 ± 0.3
LINEAR Tubular
M20 x 1.5
7.92
Mounting nut shipped loose.
250 mm min.,
0.20 mm2
PVC
3.18 ± 0.08
M20 x 1.5
7.92
Mounting nut shipped loose.
250 mm min.,
0.20 mm2
PVC
All solenoids are illustrated in energised state All specifications subject to change without notice.
Ledex® Size 125M Pull — 32 mm Dia. x 57 mm Ledex® Size 150M Pull — 38 mm Dia. x 64 mm
16.662
16.662 38.1 ± 0.381
42.062
42.062 31.75 ± 0.381 max 33.325
max 33.325
LINEAR Tubular
17.856 ± 0.381
250 mm min.,
0.34 mm2
PVC
250 mm min.,
0.34 mm2
PVC
All solenoids are illustrated in energised state All specifications subject to change without notice.
4.27
ref
16.66
42.06 44.45 ± 0.38
max 33.33
9.5 ± 0.3
LINEAR Tubular
71.45 ± 0.25
119.56
max
29.36
M4 x 0.7
8x
250 mm min.,
0.34 mm2
(Teflon)
All solenoids are illustrated in energised state All specifications subject to change without notice.