2831-SU-256 2831-TK-071 2831-PP-230 2831-PP-230A 2831-PP-231 2831-PP-231A 2831-PP-232 2831-PP-232A NOTE 6 & 7
WARM WATER WARM WATER CONCENTRATOR CONCENTRATOR FRESH WATER CONCENTRATOR CONCENTRATOR FRESH WATER CONCENTRATOR CONCENTRATOR FRESH WATER
TANK SUMP TANK FRESH WATER PUMP PUMP - ELECTRICAL MOTOR FRESH WATER PUMP PUMP - ELECTRICAL MOTOR FRESH WATER PUMP PUMP - ELECTRICAL MOTOR
1.0 m L x 1.0 mW x 1.0 m Deep Working Volume: 450 m3 697 m3/h; 62.2 m.w.c. TDH 147 kW ( E ) 697 m3/h; 62.2 m.w.c. TDH 147 kW ( E ) 697 m3/h; 62.2 m.w.c. TDH 147 kW ( E )
Concrete 9.5 m D x 9.5 m H NOTE 3
Carbon Steel (TYP.) 1"
E
FIT V-21275
A 12788
2831-CW-4"-C1E2A-21346
COOLING WATER A
NOTE 5 NOTE 5 2272 2220-PR-PID-000015
COOLING WATER TO HIG REGRIND MILL
2831-CW-18"-C1E2A-05008 2831-CW-18"-C1E2A-05008 FREQUENCY DRIVE
1205 2831-PR-PID-000001 M
FROM COOLING WATER V-21390 V-21391 FIC
P4
PUMPS 2831-PP-224 / 225 NC IA V-21396 V-21272
LI LALL S/D 12788
2831-CW-18"-C1E2A-21320 V-21392 06841 06841
I PP-230@232 FCV
2831-CW-10"-C1E2A-21345
COOLING WATER
PP-212/213 NOTE 5 12788 NOTE 5 1425 2220-PR-PID-000024
M3 TO FLOTATION BLOWER
2831-CR-18"-C1E2A-05075 YC
NOTE 6 & 11 2220-BL-001@003
LIT LI 12793
18"x16" V-21394 FL V-21393 COOLING WATER
NOTE 5 06841 06841 A 2210-CW-3"-C1E2A-21044
1323 2210-PR-PID-000029
V-21274
V-21279
2831-CR-24"-C1E2H-21299
18" 2831-CW-12"-C1E2A-21319 2210-MB-002-CY1
24" type changed)
12780
B 2831-PP-230A M 2210-CW-3"-C1E2A-21040
COOLING WATER
B
2831-CR-16"-C1E2A-21290
2831-CR-8"-C1E2A-21030
IA FL NOTE 10
2210-CW-16"-C1E2A-21180
NOTE 10 TO BALL MILL N°1
NO 1/2"
NOTE 13 2831-FRW-12"-C1E2A-05057 CYCLOCONVERTER
2210-MB-001-CY1
N-5 2831-FRW-16"-C1E2A-21263
PV MH
24" V-21035 V-21049 2210-CW-8"-C1E2A-21282 COOLING WATER
12780 N-2 2831-FRW-18"-C1E2A-21027 4"
2210-CW-4"-C1E2A-11120
V-21022 1279 2210-PR-PID-000017
18" NC
V-21278
2831-FRW-4"-C1E2A-21296
2831-FRW-18"-C1E2A-08358
2831-FRW-16"-C1E2A-21264
2831-FRW-16"-C1E2A-00001
1/2" COOLING WATER
1322 2210-PR-PID-000022 2210-CW-4"-C1E2A-21035
FROM CYCLOCONVERTER 1293 2210-PR-PID-000014
2210-MB-001-CY1
2210-CR-4"-C1E2A-21277 TO SAG MIIL MOTOR
COOLING WATER RETURN TO FLOOR 2210-MS-001A
2210-CR-3"-C1E2A-21045
2210-CR-16"-C1E2A-21181
1491 2831-PR-PID-000001
2210-MB-001A 2210-CR-8"-C1E2A-21279
TO POND HOSE
COOLING WATER RETURN TO FLOOR CONNECTION
T
2210-CR-4"-C1E2A-11127 TO FLOOR
F 1302 2210-PR-PID-000021 NOTE 12 NOTE 12
FRESH WATER F
FROM BALL MIIL N°1 MOTOR 2831-FRW-16"-C1E2A-00001
555 2831-PR-PID-000002
2210-MB-001A
TO FRESH WATER
COOLING WATER RETURN DISTRIBUTION
2210-CR-4"-C1E2A-11126
1303 2210-PR-PID-000014
FROM SAG MILL MOTOR GLAND SEAL WATER
2210-MS-001A
2210-CR-6"-C1E2A-21280 2831-GW-10"-C1E2A-21011
T 573 2831-PR-PID-000014
COOLING WATER RETURN TO GLAND SEAL WATER
2210-CR-4"-C1E2A-11125 PUMPS 2831-PP-212/213
1304 2210-PR-PID-000014
FROM SAG MILL MOTOR
2210-MS-001A SPILLAGE
2831-FRW-14"-C1E2H-05077
COOLING WATER RETURN 619 2265-PR-PID-000003
2220 2210-PR-PID-000015
2210-CR-4"-C1E2A-11296 0.5 m
SLOP
E TO PIPELINE
FROM ADJUSTABLE 100.0 m 2265-RW-20"-M1E0H2U-03206
FREQUENCY DRIVE NOTE 9
2210-PP-001/002 SPANISH LANGUAGE GOVERNS
COOLING WATER RETURN X ENGLISH LANGUAGE GOVERNS
2210-CR-4"-C1E2A-11119
571 2210-PR-PID-000010 6"
T
FROM SAG MILL LUBRICATION
SYSTEM
V-21453
COOLING WATER RETURN NC
2210-CR-3"-C1E2A-21037 1.- FOR P&ID LEGENDS AND SYMBOLS SEE DRAWINGS N°4-V2-2000-PR-PID-000001@000009. MINERA SPENCE S.A.
1320 2210-PR-PID-000030
T 2.- * INDICATES THAT IS PROVIDED BY VENDOR OR EQUIPMENT SUPPLIER.
SAG MILL CYCLOCONVERTER
3.- IN EQUIPMENT POWER DESCRIPTION, (E) ESTIMATED, (C) CALCULATED, (V) VENDOR´S CONFIRMED DATA.
2210-MS-001-CY1 TO FLOOR
4.- FOR FLUIDS CODES DETAILS SEE DRAWING N° 4-V2-2000-PR-PID-000004.
5.- PIPE DIAMETERS TO BE CONFIRMED BY VENDOR. ESCALA FECHA FECHA PROYECTO SGO
6.- TRIPLE EFFECT.
INGENIERIA
DISEÑADO DIBUJADO
7.- ELEV. 1687 MASL. POR: POR: C. ACUÑA 17-08-16
8.- END OF LINE REVISADO LIDER
UTILITIES & ONSITE INFRASTRUCTURE
9.- MINIMUM SLOPE REQUIRED. POR: H. ALVAREZ 17-08-16 DISC.: J. BARRERA 17-08-16
0 20-03-18 ISSUED APPROVED FOR DESIGN CA HA JB 10.- PENDING INFORMATION BY VENDOR WATER SUPPLY & DISTRIBUTION
GTE. INGENIERIA:
C. LEGGETT 17-08-16 GTE. PROYECTO: A. KING 17-08-16
11.- ELEV. 1686. COOLING WATER P&ID
0A 29-09-17 ISSUED FOR COMPANY APPROVAL CA HA JB
BHP
12.- CONTAINED AREA. SPILLS DRAIN TO SUMP 2831-SU-256. GTE. INGENIERIA: GTE. PROYECTO:
A 16-08-17 ISSUED FOR INTERNAL REVIEW CA HA JB FRESH WATER DISTRIBUTION - PFD 4-V2-2800-PR-PFD-000001 13.- TEMPORARY CONE STRAINER.
CONTRATO N°: REV.
PLANO PROVEEDOR N°: PLANO BHP N° :
Rev.
No.
FECHA REVISIONES DIS. REV. L.D BHP DOCUMENTOS DE REFERENCIA N° BHP NOTAS 4-V2-2831-PR-PID-000008 8500135645 4-V2-2831-PR-PID-000008 0