Está en la página 1de 5
Certificate of Conformance Ref No.: 29116 Issued to Equimed Gestion Teenologica Pasaje Oe6A 82 Y San Gabriel Quito, Ecuador Identification MODEL RGDM+MA RAPID-GOLD MA DIGITIZER S/N 49-1602 MODEL AGMS-D! MULTISENSOR, DIAG S/N 43-1279 The equipment identified above has been calibrated and tested using production acceptance procedure ‘44500005, Radcal Quality Manual PP1007, Radcal Policy and Procedure PP 1038, PI1035, PL10SS, and ‘other related documents. The equipment has been found to conform in all respects. These test Procedures are designed to ensure that the tested equipment mects or exceeds all aspects of Radcal’s Published product specifications and requirements. Radcal is an ACLASS accredited calibration lab that meets the requirements of ISO 17025 and ANSUNCLS 2540-1, cert number AC-1553. All measuren ents performed during the acceptance testing employ equipment taceable to NIST or another recognized national laboratory such as Physikalisch- Technische Bundesansalt (P18), For additional information please refer to Radca's Product note: "Service Description" Certificate Issue Date; 21-Aug-19 by Authorized Representative Raucal Corporation 426 W, Duarte Rd. Monrovia, CA 91016, DI FAX: (626) 387. 163. email service radeal co “Monrovia. CA 91016-4501 USA. Weezess7.7e21 F:68357 2063 Wimamadcal com vericw@redcal.com Xencoire Report No: 291160AL, Cer ate of Calibration ued To: Equimed Gestion Tecnologica Pasaje Oe6A 82 ¥ San Gabrel Quito, Eovador Status Equipment Description Model sm Asset, AS Left RAPIO-GOLD MA DIGITIZER RGOMeMA 49-1602 NA - MULTISENSOR, DIAG AGMS.0+ —43:1279 NA InTolerance NOTE: Pror to calibration, the equipment was examined and found to be in good condition and performed in ‘accordance with the manufacturers specifications wth the exceptions listed below 1. None Status As Found/Lett refers to system performance with each distinct sensor or chamber defining the system “The equipment ssentied above nas been calbraled and ested use stondard Radca!calbraton and acceptance procedures Trecensdance wih Racca! Quelly Manual PP1CO7, 4600129 - Certal- Diag XLT Rev @ and technical reaurements Contaved tne custome’’ order These procedutes are designed to ensure that retested equinment meets ar exceeds the stated specications and the requements of ANSUNCLS 7540-1-1094 and 1SO 17025 ‘An measurements performed dunng he tesing employ equbrrent traceable Yo NIST anotner recogn zed Nationa Catorstony such as Phyaikaisch Technische Bundesansat (PTE), Al calraionresuts ince wi hs certicate cae tecorded ot he tune of measurement and shall nat mply anything about the instrument's ute stability This ust be determined trom previous historical dala Calibration Date 21 August 2019 ‘Date of Report 21 Aujust 2019 Interval, as defined by customer. 24 morths ater date of calbratin Calibration Ove 21 August 202 Calibration Tech by Tuihorzed Reviewers E Macintosh /M. Bryant ‘Sensor Engineering RAACADP covomnon se wee Ose Rous Mivera.cx biotease! usa Peper Fetes ones Wi immumtoaicon | sowengreceatcom Report No: 291 16DAL Certificate of Calibration Measurement Test Conditions ‘An Electromed EDEC-80 X-ray generator equipped with an Eimac Model A192 tungsten target x ray tube was used as the source of the required x-ray beam. The generator nipple is less than 0.5 KV. The inherent fitration was adjusted by the addition of aluminum to produce a total fitration of 2.5mm Al in accordance with IPSM Report No, 64 “Data for Estimating X-ray Tube Total Filtration” ‘The output of the generator was measured by a Rascal DynalyzerIlIU. The test instrument and the Dynalyzer were monitored simultaneously by anaiog to digital converters with an uncertainty of + 0.1%. All reported voltage measurement results have an uncertainty of better thant 1% at the ‘95% confidence level, All dose measurements were performed using the substitution method and ‘normalized with a transmission chamber All reported dose and dose rate measurement results hhave an uncertainty of better than 2 5% at the 95% confidence level ‘The descnption and traceabilty ofall standards and equipment used inthis calibration are found in Appendix A of this report. NOTE: At dose measurements were normalized 10 22°C, 101.9 kPa "GF" = correction factor and True Reading » CF x Reading ‘All exposures were made with the DUT oriented perpendicular to the beam ‘The beams) were collmated to not excose the chamber stem Pagezete Report No: 291 160AL Mult rf n A DUT Reasings| ‘Standards Uncertainty(k2) Published Uncertainty ‘TUR! Standards Uncertainty(k=2) Published Uncertanty TuR| RAACAM conromnon ‘<8 Viet Doan Ras (e489) USA, eae serrate 3s7 200s Wemmmadeacan € verdoegracestcom DYNALYZER TANK REF DEC 80 FILTER SET ‘Thermometer, 1927C SETRA SIGNAL CONDITIONER DYN. DISPLAY APPENDIX -A- Report No: 29176DAL, 358.041219 349.092718 768-111318 347-052819 369-042919 ‘564604 112071519 345-032819 726073119 585-092818 703-100118 Note" Raden! poley 11634 proves up 30 eye pon cl uw at fr sada rcal ton 0 OF REPORT 31-4day-2020 30-Apr-7020 30-Jun-2020 3t-Ju2021 ‘-btar-2020 31-Jul-2020 30-Se0-2019 31-04-2019 Paaw acta

También podría gustarte