Está en la página 1de 1

WPS-CIV-011

P.Q.R. N° CIV-013
REV DATE PROJECT
0A 17/03/2014 PIPELINE

Welding Procedure Specification


Sheet : 1/1
Welding Supervisor
Welder
A.- Process Computerized Automatic GMAW "PWT-CWS.02"
B.- Material API 5L Gr. X65
C.- Pipe outside diameter 30" / specified OD greater than 12.750 in. (323.9 mm). As per "API 1104 para. 6.2.2 d."
D.- Wall Thickness 1" / specified pipe wall thickness greater than 0.750 in. (19.1 mm). As per "API 1104 para. 6.2.2 e."
E.- Joint desing See annex No. 1
F.- Filler metal and No. Of Layer See table No. 1
G.- Electrical or flame characteristics See table No. 1
H.- Position 5G-Fixed
I.- Direction of Welding Down-hill
J.- No. Of Welders Two (2)
K.- Time lapse between passes Max. 10 Minutes
L.- Type and removal of lineup clamp Standrad Internal Pneumatic Including PWT- Backing System
M.- Cleaning and/or grinding whit power tools cleaning, grinding
N.- Preheat 75 °C (170 °F)
O.- Stress relief --------
P.- Shielding gas and flow rate See table No. 1
Q.- Shielding Flux --------
R.- Speed of Travel See table No. 1
S.- Plasma gas flow rate --------
T.- Plasma gas composition --------
U.- Plasma gas orifice size --------
Annex No. 1

11
10
9
8
7
6
5
4

Table No. 1
Filler Metal Wire Feed Heat Travel Shielding
Current Type Amps Range
Weld Pass(es) Process Speed Input Volts (V) Speed gas and No. Layer
and Polarity (Amps)
Classification Diameter (m/min) (kJ/mm) (cm/min) flow rate

AWS ER70S- CO2 80% / AR


Root pass GMAW 1.2 mm DC + 230-300 6.8-8.0 0.4-0.5 20-23 60-85 20%
1
6

AWS ER70S-
Hot-pass GMAW 1.2 mm DC + 230-300 6.8-8.0 0.65-0.75 20-24 40-55 CO2 100% 1
6

AWS ER70S- CO2 50% / AR


Fill GMAW 1.2 mm DC + 190-280 5.0-7.0 0.65-0.75 19-22 35-50 50%
8
6

AWS ER70S- CO2 50% / AR


Cap GMAW 1.2 mm DC + 160-210 3.5-5.0 0.8-0.9 17-21 15-30 50%
1
6

TRIME,CA CARDON IV
Prepared Approved Revised Approved
Name M. SOSA J. G. NUñEZ
Signed