Está en la página 1de 17

16/02/2018

Building Bigger and Better in FRP Composites

David Kendall Optima Projects Ltd


david.kendall@optima-projects.com
+44 7774 887037

2018 Dubai © Optima Projects

Geometric efficiency
Previous examples
Much larger future FRP Structures
Questions / discussion
© Optima Projects

1
16/02/2018

Geometric efficiency

© Optima Projects

2
16/02/2018

© Optima Projects

3
16/02/2018

© Optima Projects

Design wind speed


186mph = 300 km/h
24 years old

© Optima Projects

4
16/02/2018

© Optima Projects

Radome diameter/thickness ratio 800:1


Table tennis ball ~100:1

Ø20m

© Optima Projects

5
16/02/2018

© Optima Projects

© Optima Projects

6
16/02/2018

So how will we make MUCH


larger FRP structures?

© Optima Projects

320m diameter
52m high Millennium Dome / O2 Arena
12 masts 100m high
Each mast 100 tonnes
72km of cables

© Optima Projects

7
16/02/2018

© Optima Projects

© Optima Projects

8
16/02/2018

320m (1050’) Diameter Clear Span

52m
PERSON

320m

80,425m2 covered floor area


Dome surface area 88,920m2 only 10% more than floor area

© Optima Projects

Entrance canopies incorporated whilst


maintaining shell structure philosophy

© Optima Projects

9
16/02/2018

62m wide entrance canopy


© Optima Projects

Totally open clear space inside


could form the largest single clear space ever enclosed
& the largest FRP structure ever built
© Optima Projects

10
16/02/2018

Snow / Imposed Loading to EN1991-1-3:2003

© Optima Projects

Wind Loading to EN1991-1-4:2005

Wind

© Optima Projects

11
16/02/2018

Self-weight
deflection 80mm

© Optima Projects

Self-weight +
snow load
deflection 156mm

© Optima Projects

12
16/02/2018

Wind load
deflection 94mm

© Optima Projects

Wind load + Self weight


deflection 94mm
© Optima Projects

13
16/02/2018

2 tonne load at
centre + Self weight
deflection 94mm

© Optima Projects

Self weight
Buckling Factor = 5.3

© Optima Projects

14
16/02/2018

Self weight + Snow


Buckling Factor = 2.23

© Optima Projects

Stresses all very low


FoS >10

© Optima Projects

15
16/02/2018

Structural Details

• Structure self weight ~ 4000 tonnes


• Self-weight < snow load
• Very high utilisation of material
• Very high thermal insulation
• 2652 tonnes of air in dome
• Diameter/thickness ratio 800:1,
8 times more slender than table tennis ball

© Optima Projects

Methods of Construction
• Conventional moulded panels assembled
on site.
• Sub-assembly of large areas, jacked into
position.
• Very large panels moulded on site
(no transport limits).
• Moulded as 1 piece continuous structure
over inflated fabric former.
• Robotics, drones, additive manufacture etc

© Optima Projects

16
16/02/2018

Thank you – Questions/Discussion


David Kendall - Optima Projects Ltd

david.kendall@optima-projects.com
Tel +44 7774 887037
Optima Projects

17

También podría gustarte