Está en la página 1de 1

NOTES

1. ALL DIMENSIONS ARE IN mm


2. CONCRETE FOR ALL STRUCTURAL MEMBERS TO BE
FOUNDATION AND COLUMNS GRADE 25
SLABS, BEAMS, STAIRS AND RAMP GRADE 25
3. READ THIS DRAWING IN CONJUCTION WITH
RELEVANT ARCHITECTURAL DRAWINGS.
4. UNLESS OTHERWISE STATED, MINIMUM COVER TO
ALL REINFORCEMENTS TO BE:
FOUNDATION 50mm
A A1 B C 5.
COLUMNS 30mm
ALL REINFORCING STEEL TO HAVE
CHARACTERISTIC STRENGTH OF 410N/mm² (HIGH
9700 6.
TENSILE STEEL) TO BS 4449
AGGREGATES TO BE OF MAXIMUM SIZE OF 20MM
GRADED TO TABLE 4 BS 881 : 1983 FOR ALL
4850 4850 STRUCTURAL MEMBERS

No. Revision By.


F1 F1 F1 F1
C1
1
C1 C1 C1

2 2
Date Issued to:
2 2 2 2
4075
7625

F1 F1 F1 Project
PROPOSED RESIDENTIAL HOUSE
TO BE BUILT ON PLOT No ..... ,
2 BLOCK "....."
C1 C1 C1 AT KEREGE AMANI-BAGAMOYO

Client
3550

PASCHAL B MAZIKU
P.O.BOX.....
DSM

STR ENGINEER

F1 F1 F1

3
C1 C1 C1 Job stage and description
STRUCTURAL DRAWING

Job No 2019/005

Drawing No. STR - 01

FOUNDATION LAYOUT PLAN Drawing Title

FOUNDATION LAYOUT PLAN

Drawn: M.H.K
Checked: H.S
Date: JULY. 2019