Está en la página 1de 8

Job Number Sheet

Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

S12
Beam - Column Connection - Ver W2.4.02 - 08 Jan 2009

Title : Default Connection


Code of Practice : AISC - 1999 LRFD
Created : 7/19/2019 4:49:37 PM

Notes and Assumptions


1 All bolt holes are assumed to be normal clearance holes.
2 All bolts are assumed to have threads in their shear planes.
3 It is assumed that the connection is deep enough for the flanges
to resist the compressive and tensile forces in them.
4 It is assumed that compressive forces in flanges and stiffeners
are conveyed through welds and not through bearing.
5 Axial force in the column is not considered in the design.

Summary

Summary of Forces and Capacities for Design to AISC - 1999 LRFD

Check Member Type LC Applied Capacity Units % of Cap. ?

1 Weld Flange 1 0.5 158.1 kN 0.3 O.K.

2 Weld Web 1 140 296.9 kN 47.2 O.K.

3 Column Web Tension Yielding N/A N/A N/A kN N/A N/A

4 Column Web Compression Crippling 1 0.5 187.9 kN 0.3 O.K.

5 Column Web Compression Buckling 1 0.5 219.9 kN 0.2 O.K.

6 Column Web Shear 1 0.5 291.6 kN 0.2 O.K.

7 Bolts & Flange Tension & Bending N/A N/A N/A kN N/A N/A

8 Column Flange Bearing 1 23.3 212.6 kN 11 O.K.

9 Bolts & End Plate Tension & Bending N/A N/A N/A kN N/A N/A

10 End Plate Bearing 1 23.3 121.5 kN 19.2 O.K.

11 Bolts Shear 1 23.3 37.7 kN 61.9 O.K.

12 Bolts Shear & Tension N/A N/A N/A kN N/A N/A

13 Bolts Slip N/A N/A N/A kN N/A N/A

Input
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

General Settings
Bolt Tension Analysis Elastic
Bolt Type Bearing
Bolt Grade 4.6
Member Ultimate Strength 450
Member Yield Strength 240
Weld Ultimate Strength 480

Connection Type Flush End Plate


Column H250X250 I1
Beam H200X100 I1
Column Extent Above(mm) 100
Beam Angle 0
Haunch Depth (mm) 0
Haunch Length (mm) 0
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Ultimate Limit State Loads in Beam SLS Factor


Shear Axial Moment (Divide to
Load Case get Loads)
(kN) (kN) (kNm)
1 140 1 0 1

Width (mm) 112


Extent Above Beam Flange (mm) N/A
End Plate Extent Below Beam Flange (mm) N/A
Thickness (mm) 8
Stiffeners N/A
Width (mm) None
Top Stiffener Thickness (mm) None
Column Stiffeners Bottom Stiffener Thickness (mm) None
Shear Stiffener Thickness (mm) None
Shear Stiffener Orientation None
Layout None
Web Plates
Thickness (mm) None
Top Backing Plate Thickness (mm) None
Bottom Backing Plate Thickness (mm) None
Bolts Diameter (mm) 20
Above Top Flange N/A
Below Top Flange 2
Rows of Bolts Above Bottom Flange 1
Below Bottom Flange N/A
Row Spacing (mm) 65
Web (mm) 30
Bolt Offsets Flange (mm) 30
Above Haunch (mm) N/A
Beam Flanges 6
Beam Web (mm) 6
Welds Top Stiffener (mm) N/A
Bottom Stiffener (mm) N/A
Shear Stiffener (mm) N/A

Check 1 : Capacity of the Beam Flange Welds


The worst load is encountered for Load Case : 1
Fw = 0.5 kN

Table J2.5

 . Fw . Aw
Rw =
1000
0.75 ×288 ×731.856
=
1000
= 158.081 kN

Beam Flange Weld is safe

Check 2 : Capacity of the Beam Web Welds


The worst load is encountered for Load Case : 1
Fw = 140 kN
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Table J2.5

 . Fw. Aw
Rw =
1000
0.75 ×288 ×1 374.616
=
1000
= 296.917 kN

Beam Web Weld is safe

Check 3 : Capacity of the Column web in tension


No tensile forces on the web

Check 4 : Crippling Capacity of the Column web in Compression


Opposite Top flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =0.5 kN

The Capacity of the web is :


K1-3
tw. leff . f y
Rn =
1000
9 ×87 ×240
=
1000
= 187.920 kN

Opposite Bottom flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =0.5 kN

The Capacity of the web is :


K1-3
tw. leff . f y
Rn =
1000
9 ×162 ×240
=
1000
= 349.920 kN

Column web is safe in compression for crippling

Check 5 : Buckling Capacity of the Column web in Compression


Opposite Top flange of the beam :

The worst load is encountered for Load Case : 1


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

when Fn =0.5 kN

K1-4
1.5
3 . N. tw .
. f y tf
 . 178.5 . tw2 . 1 +
d tf tw
Rn =
1000
3 ×8 9 1.5 240 ×14
0.75 ×178.5 ×9 2 × 1 + × ×
250 14 9
=
1000
= 219.891 kN

Opposite Bottom flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =0.5 kN

K1-4
1.5
3 . N. tw .
. f y tf
 . 354.5 . tw2 . 1 +
d tf tw
Rn =
1000
3 ×8 9 1.5 240 ×14
0.75 ×354.5 ×9 2 × 1 + × ×
250 14 9
=
1000
= 436.703 kN

Column web is safe in compression for buckling

Check 6 : Shear Capacity of the Column Web


The worst load is encountered for Load Case : 1
when Pv =0.5 kN

K1-7
0.9 . 0.6 . f y. tw. dc
Rv =
1000
0.9 ×0.6 ×240 ×9 ×250
=
1000
= 291.600 kN

Column web shear is safe

Check 7 : Bolt tension and Column Flange Bending


No tensile bolt forces

Check 8 : Bearing on the Column Flange


There are two checks : Check 1 :
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

The worst load is encountered for Load Case : 1


Fn = 23.333 kN

The Bearing Capacity of the flange at any Bolt is :


J3.10
 . 1.5 . Fu. Lc. t
Rn =
1000
0.75 ×1.5 ×450 ×30 ×14
=
1000
= 212.625 kN

Check 2 :
The Bearing Capacity of the Plate at any Bolt is :
J3.10
 . 3.0 . Fu. d . t
Rn =
1000
0.75 ×3.0 ×450 ×20 ×14
=
1000
= 283.500 kN

Column flange bearing is safe

Check 9 : Bolt tension and End Plate Bending


No bolt tensile forces

Check 10 : Bearing on the End Plate


There are two checks : Check 1 :
The worst load is encountered for Load Case : 1
Fn = 23.333 kN

The Bearing Capacity of the Plate at any Bolt is :


J3.10
 . 1.5 . Fu. Lc. t
Rn =
1000
0.75 ×1.5 ×450 ×30 ×8
=
1000
= 121.500 kN

Check 2 :
The Bearing Capacity of the Plate at any Bolt is :
J3.10
 . 3.0 . Fu. d . t
Rn =
1000
0.75 ×3.0 ×450 ×20 ×8
=
1000
= 162.000 kN
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

End plate bearing is safe

Check 11 : Shear Capacity of the Bolts


The worst load is encountered for Load Case : 1
when Fn =23.333 kN

J3.6
C-J3-4
Fn = 0.4 . Fu
= 0.4 ×400
= 160.000 MPa

The resistance of any bolt is :

n .  . Fn. Ab
Rshear =
1000
1 ×0.75 ×160.000 ×314.159
=
1000
= 37.699 kN

Bolt shear is safe

Check 12 : Shear and Tension Capacity of the Bolts


No shear or tension forces on the bolts
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Bolt Forces

Bolt Forces for Load Case : 1

0 kN

0 kN

0 kN

Shear force per bolt : 23.33 kN