Está en la página 1de 4

Dial Setting /Deviation Setting Type

Analog and Non indication type ,Set temperature by dial


(A)
Counter

▣Features

lNon indicating type (B)


lTemperature deviation indication Timer

type by LED : TDM, TDL


lSetting temperature by Dial : TOS (C)
Temp.
controlle

(D)
Power
controlle
Please read "Caution for your safety" in operation
! manual before using.

(E)
Panel
meter
▣Ordering information
(F)

T O S F 4 Tacho/
R P 4 C Speed/
Pulse
meter

(G)
Unit Display
C ℃ unit

X 0~60
1 0~100
(H)
2 0~200 Sensor
controlle
Temperature range 3 0~300
4 0~400
6 0~600 (I)
8 0~800 Proximit
sensor
C 0~1200

P Pt100Ω
Sensor input type (J)
J J(IC) Photo
electri c
K K(CA) sensor

Output mode R Relay output


S SSR output
(K)
Pressur
Power supply 3 110/220VAC 50/60Hz sensor

4 100-240VAC 50/60Hz

P Proportional control (L)


Control mode Rotary
F ON/OFF control encoder
B ON/OFF, Proportional control
(M)
S DIN W48×H48mm
Size 5-Phase
M DIN W72×H72mm stepping
motor &
L DIN W96×H96mm Driver &
Controlle

Digit O Non-indication type


D LED deviation indication type
Item
T Temperature

※Please check the range of temperature when select model. (Please see page C-41)

C-40
TOS/TOM/TDM/TOL/TDL

▣Temperature range for each sensor


Model TOS / TOM / TDM / TOL / TDL
Sensor Thermocouples RTD
input type J(IC) K(CA) Pt100Ω
1200℃
(℃/℉ ) 1200
1000
800℉ 800℃
Standard 800 600℉
600℉ 600℃
scale 600 400℉
400℃ 400℃ 400℃
range 400 200℉ 300℃ 300℃
200℃ 200℃ 200℃
200
100℃ 100℃ 100℃
100 60℃
0

※Only TOS series is available ℉ degree for above Temp. range.

▣Specifications
Model TOS TOM TDM TOL TDL

Power supply 100-240VAC


110/220VAC 50/60Hz
50/60Hz
Allowable voltage
range 90 ~ 110% of rated voltage

Power consumption 2VA 3VA


LED ON/OFF LED deviation LED ON/OFF LED deviation
Display method LED ON indicator
indicator indicator indicator indicator
Display accuracy
Setting method Dial setting
Setting accuracy F・S ± 2%
Sensor input Thermocouples : K(CA), J(IC) / RTD : Pt100Ω
Input line resistance Thermocouples : Max. 100Ω, RTD : Max. 5Ω per a wire
ON/OFF Hysteresis : F・S 0.5 ±0.2% fixed
Control
Proportional Proportional band : F・S 3% fixed, Period : 20sec. fixed
lRelay output :
250VAC 2A 1c
lRelay contact output : 250VAC 3A 1c
Control output lSSR Output :
12VDC ±3V lSSR Output : 12VDC ±3V 20mA max.
Load 20mA Max.
Self-diagnosis Built-in burn out function
Insulation resistance Min. 100MΩ(at 500VDC)
Dielectric strength 2000VAC 50/60Hz for 1 minute
Noise strength ±2kV the square wave noise(pulse width:1㎲) by the noise simulator
Mechanical 0.75mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 1 hour
Vibration
Malfunction 0.5mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 10 minutes
Mechanical 300m/s²(Approx. 30G) 3 times at X, Y, Z direction
Shock
Malfunction 100m/s²(Approx. 10G) 3 times at X, Y, Z direction

Relay Mechanical Min. 10,000,000 times


life cycle Electrical Min. 100,000 times(250VAC 3A at resistive load )
Ambient temperature -10 ~ +50℃(at non-freezing status)
Storage temperature -25 ~ +65℃(at non-freezing status)
Ambient humidity 35 ~ 85%RH
Weight Approx. 104g Approx. 419g Approx. 461g Approx. 426g Approx. 471g

C-41
Dial Setting /Deviation Setting Type
▣Connections
(A)
※RTD(Resistance Temperature Detector) : Pt 100Ω(3-wire type) ※Thermocouple : K, J, R Counter

lTOS lTOM, TDM


SSR OUT:
12VDC ±3V (B)
CONTACT OUT: 20mA Max. Timer
250VAC 2A 1c 1 8 (TDM outut s up
RESISTIVE LOAD
H to 16VDC)
SSR OUT: + C CONTACT OUT: C
12VDC ±3V 2 250VA C 3A 1c 9 -
(C)
20mA Max. - 4 5 RESISTIVE LOAD Temp.
L H L
B' 3 10 + controlle
3 6

- B 4 11
2 7 B'
(D)
! SOURCE
Power
SENSOR 1 8 5 12 controlle
B - 220VAC
+ A
~ S ENSOR 6 SENSOR ~ 13
T.C RTD 110VAC
! SOURCE ~ (E)
100-240VAC + 0V Panel
7 14
50/60Hz A T.C meter
RTD

(F)
Tacho/
lTOL, TDL Speed/
Pulse
meter
RTD T.C
CONTACT OUT: 1 18
A +
250VAC 3A 1c L (G)
Display
RESISTIVE LOAD 2 17 unit
C SENSOR
H
3 16 B
(H)
Sensor
SSR OUT: - 4 15 controlle
B' -
12VDC ±3V
20mA Max. + 5 14
※TDL outputs (I)
Proximity
up to 16VDC 6 13 sensor

220 VAC
7 12
(J)
110VAC Photo
! SOURCE ~ 8 11 electric
~ sensor
0V
9 10
(K)
Pressur
sensor

▣Dimensions
lTOS (L)
Rotary
lPanel cut-out encoder

92
48 Min. 53
13 64 15 (M)
5-P hase
stepping
motor &
+ 0.6 Driver &
45 -0 Controlle

M in. 62 45 +0.6
-0

TOS

Unit:mm

C-42
TOS/TOM/TDM/TOL/TDL
▣Dimensions

lTOM, TDM lPanel cut-out


Min. 91
132
72
20 102 10

ON OFF
ON O FF
68 +0
-0
.7

200 10 0

Min. 91
68 +- 0.0 7
IN P UT K

℃ IN P U T K


TO M TD M

Unit:mm

lTOL, TDL
1 21 lPanel cut-out
96
21 87 13 Min. 116

ON O FF
ON OFF

2 00 100
92 +- 0.8
0

Min. 116
I N PU T K
92 +0
-0
.8

C I N PU T K


T OL TDL

Unit:mm

▣Proper usage
◎Application of temperature controller and load ◎How to select ON/OFF or proportional by plug
connection pin
lSSR output Factory specification is proportional control.
Temperature When using ON/OFF control, transfer the switch of
controller SSR
control mode from P to F after detaching the case
+
+
from its body.
SSR I
L Load Note)Several models require changing control
driving 12VDC N
P O
voltage 20mA M ax A mode by jump line or solder.
U Load
out put D ~
T power
terminal -
-

P F P F
lRelay output
Temperat ure controller Proportional control ON/OFF control
Load
NO ◎Indicating LED deviation
L Load
~ power The price of digital indicating type is high and non-
C COM
indicating type has a problem with catching actual
H temperature.
Relay contact output terminal
NC 250VAC 2A 1c In this case indicating deviation type is useful.
250VAC 3A 1c
LED deviation indicator is a temperature controller
◎NormalU Reverse operation having the function of lighting or putting out light.
Reverse operation outputs ON when processing ※The shipping specification is 10℃ per one LED.
value is lower than setting value, and it is used Extending temperature deviation is available with
with reverse operation when heated. additional orde
On the contrary, normal operation runs conversely
and used for cooling. (This item runs as a reverse
operation)

C-43