PVSYST V6.

81 20/06/19 Page 1/4

Grid-Connected System: Simulation parameters


Project : New Project
Geographical Site Sadhu Country India
Situation Latitude 28.47° N Longitude 77.05° E
Time defined as Legal Time Time zone UT+5.5 Altitude 228 m
Albedo 0.20
Meteo data: Sadhu PVGIS api TMY - TMY

PVsyst TRIAL
Simulation variant :

Simulation parameters
Collector Plane Orientation
New simulation variant
Simulation date

System type
Tilt
20/06/19 02h53

No 3D scene defined, no shadings


23° Azimuth 0°
Models used Transposition Perez Diffuse Imported
Horizon Free Horizon
Near Shadings No Shadings
User's needs : Unlimited load (grid)

PVsyst TRIAL
PV Array Characteristics
PV module Si-poly Model Eldora VSP.72.335.05
Original PVsyst database Manufacturer Vikram Solar
Number of PV modules In series 18 modules In parallel 12 strings
Total number of PV modules Nb. modules 216 Unit Nom. Power 335 Wp
Array global power Nominal (STC) 72.4 kWp At operating cond. 69.7 kWp (35°C)
Array operating characteristics (50°C) U mpp 658 V I mpp 106 A
Total area Module area 419 m²

Inverter Model SG60KTL


Original PVsyst database Manufacturer Sungrow
Characteristics Operating Voltage 570-950 V Unit Nom. Power 60.0 kWac
Inverter pack Nb. of inverters 1 units Total Power 60 kWac

PVsyst TRIAL
Pnom ratio 1.21

PV Array loss factors


Array Soiling Losses Loss Fraction 1.5 %
Thermal Loss factor Uc (const) 29.0 W/m²K Uv (wind) 0.0 W/m²K / m/s
Wiring Ohmic Loss Global array res. 97 mOhm Loss Fraction 1.5 % at STC
LID - Light Induced Degradation Loss Fraction 2.0 %
Module Quality Loss Loss Fraction 3.0 %
Module Mismatch Losses Loss Fraction 1.0 % at MPP
Strings Mismatch loss Loss Fraction 0.10 %
Incidence effect (IAM): Fresnel smooth glass, n = 1.526
0° 30° 50° 60° 70° 75° 80° 85° 90°

PVsyst TRIAL
1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

System loss factors


Wiring Ohmic Loss Wires: 3x35.0 mm² 83 m Loss Fraction 2.0 % at STC
Unavailability of the system 3.0 days, 3 periods Time fraction 0.8 %

Auxiliaries loss Proportionnal to Power 5.0 W/kW ... from Power thresh. 0.0 kW

PVsyst Evaluation mode


PVSYST V6.81 20/06/19 Page 2/4

Grid-Connected System: Main results


Project : New Project
Simulation variant : New simulation variant
Main system parameters System type No 3D scene defined, no shadings
PV Field Orientation tilt 23° azimuth 0°
PV modules Model Eldora VSP.72.335.05 Pnom 335 Wp
PV Array Nb. of modules 216 Pnom total 72.4 kWp
Inverter Model SG60KTL Pnom 60.0 kW ac

PVsyst TRIAL
User's needs Unlimited load (grid)

Main simulation results


System Production Produced Energy 122512 kWh/year Specific prod. 1693 kWh/kWp/year
Performance Ratio PR 78.11 %

Normalized productions (per installed kWp): Nominal power 72.4 kWp Performance Ratio PR

8 1.0
Lc : Collection Loss (PV-array losses) 1.14 kWh/kWp/day PR : Performance Ratio (Yf / Yr) : 0.781
0.9
7 Ls : System Loss (inverter, ...) 0.16 kWh/kWp/day
Yf : Produced useful energy (inverter output) 4.64 kWh/kWp/day
0.8
[kWh/kWp/day]

6
0.7
Performance Ratio PR

5
0.6

PVsyst TRIAL
Energy

4 0.5

0.4
3
Normalized

0.3
2
0.2

1
0.1

0 0.0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

New simulation variant


Balances and main results

PVsyst TRIAL
GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR
kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh
January 108.7 44.76 13.10 146.2 140.0 9070 8415 0.795
February 118.3 48.22 16.40 146.3 140.1 8911 8660 0.818
March 185.4 58.98 23.20 212.7 204.2 12414 12047 0.783
April 205.8 72.00 29.15 213.7 204.6 12130 11778 0.762
May 197.7 87.36 31.62 191.6 182.9 10854 10548 0.761
June 206.4 97.58 34.11 194.8 185.8 10961 10661 0.756
July 179.1 97.98 30.00 171.3 163.0 9940 9403 0.759
August 198.7 82.48 31.69 200.2 191.3 11437 11112 0.767
September 160.4 71.78 27.88 174.2 166.6 10184 9899 0.785
October 160.2 58.09 26.12 194.0 186.1 11322 11001 0.784
November 129.6 45.60 22.17 173.6 166.7 10356 10068 0.801
December 108.0 43.06 14.54 148.9 142.9 9174 8921 0.828

PVsyst TRIAL Year

Legends: GlobHor
DiffHor
T_Amb
GlobInc
1958.4 807.90

Horizontal global irradiation


Horizontal diffuse irradiation
Ambient Temperature
Global incident in coll. plane
25.03 2167.5 2074.3

GlobEff
EArray
E_Grid
PR
126753 122512 0.781

Effective Global, corr. for IAM and shadings


Effective energy at the output of the array
Energy injected into grid
Performance Ratio

PVsyst Evaluation mode


PVSYST V6.81 20/06/19 Page 3/4

Grid-Connected System: Special graphs


Project : New Project
Simulation variant : New simulation variant
Main system parameters System type No 3D scene defined, no shadings
PV Field Orientation tilt 23° azimuth 0°
PV modules Model Eldora VSP.72.335.05 Pnom 335 Wp
PV Array Nb. of modules 216 Pnom total 72.4 kWp
Inverter Model SG60KTL Pnom 60.0 kW ac

PVsyst TRIAL
User's needs Unlimited load (grid)

Daily Input/Output diagram

500
Values from 01/01 to 31/12

400
[kWh/day]
grid

300

PVsyst TRIAL
into
injected

200
Energy

100

0
0 1 2 3 4 5 6 7 8
Global incident in coll. plane [kWh/m².day]

System Output Power Distribution

PVsyst TRIAL 3500

3000
Values from 01/01 to 31/12
Bin]
/

2500
[kWh
grid

2000
into

1500
injected

PVsyst TRIAL 1000


Energy

500

0
0 10 20 30 40 50 60
Power injected into grid [kW]

PVsyst Evaluation mode


PVSYST V6.81 20/06/19 Page 4/4

Grid-Connected System: Loss diagram


Project : New Project
Simulation variant : New simulation variant
Main system parameters System type No 3D scene defined, no shadings
PV Field Orientation tilt 23° azimuth 0°
PV modules Model Eldora VSP.72.335.05 Pnom 335 Wp
PV Array Nb. of modules 216 Pnom total 72.4 kWp
Inverter Model SG60KTL Pnom 60.0 kW ac

PVsyst TRIAL
User's needs Unlimited load (grid)

Loss diagram over the whole year

1958 kWh/m² Horizontal global irradiation


+10.7% Global incident in coll. plane

0.00% Global incident below threshold


-2.84% IAM factor on global
-1.50% Soiling loss factor

2074 kWh/m² * 419 m² coll. Effective irradiation on collectors

PVsyst TRIAL efficiency at STC = 17.28%

150215 kWh
-0.35%

-3.00%
-8.89%
PV conversion

Array nominal energy (at STC effic.)


PV loss due to irradiance level

PV loss due to temperature

Module quality loss


-2.00% LID - Light induced degradation
-1.10% Mismatch loss, modules and strings
-1.14% Ohmic wiring loss
126757 kWh Array virtual energy at MPP

-1.19% Inverter Loss during operation (efficiency)

PVsyst TRIAL
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
125240 kWh Available Energy at Inverter Output

-0.50% Auxiliaries (fans, other)


-0.55% System unavailability
-1.15% AC ohmic loss
122512 kWh Energy injected into grid

PVsyst TRIAL
PVsyst Evaluation mode