Está en la página 1de 4

DTMA-800-900-12-AISG

Fullband Double Dual Duplex Tower Mounted Amplifier


(Masthead Amplifier)

• Double unit for easy use with XPol antennas


• Suitable for antenna RET control according to AISG/3GPP standard
• Bypass mode to ensure cell operation in case of DC power down
• Supports AISG 1.1 and AISG 2.0 (default) Ant1 Ant2
• Supports Wide-Band (configuration 1 ... 6) or Single-Band Mode
(configuration 7,8 or 9)
• Built-in lightning protection

AISG = Antenna Interface Standards Group


RET = Remote Electrical Tilt

Technical Data

Type No. Single-Band Mode 78210512V43


DTMA-800-900-12-AISG BTS1
Wide-Band Mode 78210512V44 AISG AISG
BTS2
DTMA-800-900-12-AISG
out1 out2
800 MHz Tx Characteristics
Frequency range MHz 791 - 821
Insertion loss dB Typically 0.5
Input power kW < 0.18 (+52.5 dBm) / < 1.6 (+62 dBm) peak
(per input and frequency band)
Antenna
Intermodulation products in RX dBm < -117 (2 Tx carriers at +43)
band
Return loss dB > 18
RCU RCU
800 MHz Rx Characteristics
Frequency range MHz 832 - 862
Loss in bypass mode dB Typically 2.0 Ant 1 Ant 2

Return loss dB > 18 (DC ON) / > 14 dB (DC OFF) Double TMA
Subject to alteration.

Gain dB 12 nominal
Noise figure dB Typically 1.5
3rd order intercept point (OIP3) dBm Typically 25
900 MHz Tx Characteristics
Frequency range MHz 925 - 960
Insertion loss dB Typically 0.5
Input power kW < 0.18 (+50 dBm) / < 1.6 (+62 dBm) peak
Feeder cable
936.0000138b

(per input and frequency band)


Intermodulation products in RX dBm < -117 (2 Tx carriers at +43)
band
Return loss dB > 18
900 MHz Rx Characteristics
Frequency range MHz 880 - 915
Loss in bypass mode dB Typically 2.0 Dual-band Combiner
Double Unit
Return loss dB > 18 (DC ON) / > 14 (DC OFF) DC-stop DC-stop

Gain dB 12 nominal
Noise figure dB Typically 1.5
3rd order intercept point (OIP3) dBm Typically 25

Main Div Div Main

BTS 800 BTS 900

78210512V43 - 78210512V44 Page 1 of 4


KATHREIN SE | Anton-Kathrein-Straße 1–3 | 83022 Rosenheim, Germany | Phone +49 8031 184-0 | www.kathrein.com | mobilcom@kathrein.de
DTMA-800-900-12-AISG
Fullband Double Dual Duplex Tower Mounted Amplifier
(Masthead Amplifier)

Environmental Characteristics
Operating temperature range °C |°F -40 ... +65 | -40 ... +149
IP rating IP67*
MTBF hours > 1 000 000 (per TMA)
EMC According to ETS 300 342-3
Lightning protection kA 3, 10/350 µs pulse
DC and Alarm Characteristics AISG Mode
DC supply V DC 9 - 31
Operating current per DTMA mA Nom. 300 at 10 V
(without RET) mA Nom. 100 at 30 V
Alarm management AISG*
Mechanical Characteristics
Material Aluminium housing
Connectors RF 4.3 - 10 female
AISG out 8-pin female, IEC 60130-9
(Pin 3: RS485B, pin 5: RS485A, pin 6: 10 - 30 V DC,
pin 7: DC return, other pins: Not connected)
Mounting Wall mounting: With 4 screws (max. 8 mm diameter)
Mast mounting: With additional clamp set
Weight kg | lb 11 | 24.3
Dimensions (w x h x d) mm | in 231 x 246 x 159 | 9.0 x 9.6 x 6.3
(without connectors, without mounting brackets)
Packing size mm | in 397 x 297 x 240 | 15.6 x 12.2 x 9.4
* See note on page 4

Block Diagram

Subject to alteration.
936.0000138b

Page 2 of 4 78210512V43 - 78210512V44


KATHREIN SE | Anton-Kathrein-Straße 1–3 | 83022 Rosenheim, Germany | Phone +49 8031 184-0 | www.kathrein.com | mobilcom@kathrein.de
DTMA-800-900-12-AISG
Fullband Double Dual Duplex Tower Mounted Amplifier
(Masthead Amplifier)

DC Supply, Current Window Alarm and AISG Configuration


(automatically chosen by the DTMA depending on incoming signals)

Wide-Band-Mode
Configuration 1 Configuration 2 Configuration 3 Configuration 4 Configuration 5 Configuration 6

Ant 1 Ant 2 Ant 1 Ant 2 Ant 1 Ant 2 Ant 1 Ant 2 Ant 1 Ant 2 Ant 1 Ant 2

TMA 1 TMA 2 TMA 1 TMA 2 TMA 1 TMA 2 TMA 1 TMA 2 TMA 1 TMA 2 TMA 1 TMA 2

Node B1 Node B2 Node B1 Node B2 Node B1 Node B2 Node B1 Node B2 Node B1 Node B2 Node B1 Node B2

AISG AISG AISG AISG AISG AISG


800 800 800 800 800 800
+ + + + + +
900 900 900 900 900 900
DC DC DC DC DC DC DC DC

Configuration 7 Configuration 8 Configuration 9

Ant 1 Ant 2 Ant 1 Ant 2 Ant 1 Ant 2

TMA 1 TMA 2 TMA 1 TMA 2 TMA 1 TMA 2


Subject to alteration.

Node B1 Node B2 Node B1 Node B2 Node B1 Node B2

AISG AISG AISG AISG AISG AISG


800 900 800 900 800 900

DC DC DC DC
936.0000138b

Accessories (order separately)

Type No. Clamps suitable for


mast diameter
731651 [mm | in] 28 – 60 | 1.1 – 2.4
738546 [mm | in] 42 – 115 | 1.7 – 4.5
85010002 [mm | in] 110 – 220 | 4.3 – 8.7
85010003 [mm | in] 210 – 380 | 8.3 – 15.0

78210512V43 - 78210512V44 Page 3 of 4


KATHREIN SE | Anton-Kathrein-Straße 1–3 | 83022 Rosenheim, Germany | Phone +49 8031 184-0 | www.kathrein.com | mobilcom@kathrein.de
DTMA-800-900-12-AISG
Fullband Double Dual Duplex Tower Mounted Amplifier
(Masthead Amplifier)

Dimensions

172

159

245,4

323
4.3-10 Jack (f) AISG OUT (f) (2x) M8 GND
(4x)

80

230,6

68
8,5

Subject to alteration.

Mounting Instructions

The coupling torque at 4.3-10 connectors is 5 - 8 Nm! The tightning torque for fixing the As a result of more stringent legal regulations and judgements regarding product liability,
936.0000138b

AISG connector must be 0.5 – 1.0 Nm (‘handtightened’). we are obliged to point out certain risks that may arise when products are used under
extraordinary operating conditions.
The DTMA needs to be powered by a LPS (Limited Power Source, Class: PS2) according to Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress
IEC/EN 62368-1. The DTMA needs to be grounded according to EN 62305-3 or equivalent (e.g. strain caused by oscillating support structures), may result in the breakage of a
standard. mast mounted device or even cause it to fall to the ground.
It is recommended to install the DTMA’s with the antenna connectors pointing upwards KATHREIN tower mounted amplifiers are designed to operate under the environmental
and the BTS connectors pointing downwards. conditions as described in ETS 300 019-1-4 class 4.1E and have passed environmental
tests as specified in ETS 300 019-2-4. The homogenous design of KATHREIN‘s tower
It is recommended to mount the DTMA’s with the RET-connectors (Remote Electrical mounted amplifiers use identical modules and materials. Extensive tests have been
Tilt-connectors according to AISG Standard) always pointing downwards! A downward performed on typical samples and models.
slanted mounting position between the vertical and horizontal plane is also allowed.
The installation team must be properly qualified and also be familiar with the
AISG Setting relevantnational safety regulations.
The protocol of the software interface can be switched between AISG 2.0 / 3GPP and The details given on our data sheets have to be followed carefully when installing
AISG 1.1 and vice versa with a vendor specific command (depending on default setting). theantennas, filters, combiners, amplifiers and accessories.
If the primary station does not support the default setting, it has to be switched over
before system start-up. Please contact Kathrein for further information. The limits for the coupling torque of RF connectors, recommended
by the connector manufacturers must be obeyed.
Please note
Any previous datasheet issues have now become invalid.
The DTMA is not designed for permanent operation under water. Test conditions for the
IP67 rating: Submerge depth 1 m, submerge time 1 hour.

Page 4 of 4 78210512V43 - 78210512V44


KATHREIN SE | Anton-Kathrein-Straße 1–3 | 83022 Rosenheim, Germany | Phone +49 8031 184-0 | www.kathrein.com | mobilcom@kathrein.de