Está en la página 1de 13

CALCULO DE POBLACION FUTURA DE KELLUYO

1.0.- DATOS CENSALES DE POBLACION NOMINALMENTE CENSADOS

POBLACION
AÑO MUJER HOMBRE TOTAL POBLACION DEL DISTRITO DE KELLUYO SEGUN LOS CENSOS

### 1515 1608 3123 5000

### 1913 1914 3827 4500


### 2220 2132 4352
4000
### 2122 2127 4249
3500
### 2374 2575 4949
FUENTE INEI 3000
1960 1968 1976 1984 1992 2000 2008 2016
AÑOS

1.1.- METODO DE CRECIMIENTO ARITMETICO

AÑO TOTAL r
### 3123 0.01879
12### 3827 0.01143
12### 4352 -0.0118
2### 4249 0.01647
10### 4949 0.0087 0.0087
1### P=4992
3### P=5078 𝑟=(�_�/�_𝑜
𝑟=(�_�/�_𝑜 −1)/𝑡
−1)/𝑡
4### P=5122
2### P=5035
22### P=5898
�_�=�_𝑜
�_�=�_𝑜 (1+𝑟.𝑡)
(1+𝑟.𝑡)
1.2.- METODO DE CRECIMIENTO GEOMETRICO

AÑO TOTAL r
### 3123 0.01708
12### 3827 0.01077
12### 4352 -0.0119
2### 4249 0.01537
10### 4949 0.0078 0.0078
1### P=4988
3### P=5066
4### P=5106 𝑟=(�_�/�_𝑜
𝑟=(�_�/�_𝑜 ))
2### P=5027 ^(1/𝑡)−1
^(1/𝑡)−1
22### P=5875

�_�=�_𝑜 (1+𝑟)^𝑡
1.3.- METODO DE CRECIMIENTO WAPPAUS �_�=�_𝑜 (1+𝑟)^𝑡
POBLACION

AÑO TOTAL r ESTIMACION POBLACIONAL HASTA 2039


7000
### 3123 0.01688
6500
6000
5500
5000
POBLACION
ESTIMACION POBLACIONAL HASTA 2039
7000
6500
12### 3827 0.0107
6000
12### 4352 -0.012 5500
2### 4249 0.01522 5000
10### 4949 0.0077 0.0077 4500
1### P=4987 4000
3### P=5065 3500
4### P=5104 3000
𝑟=2(�_�−�_𝑜
𝑟=2(�_�−�_𝑜
1960 )/𝑡(
)/𝑡( 2000 2010 2020 2030 2040
1970 1980 1990
2### P=5026 �_�+�_𝑜
�_�+�_𝑜 )) AÑOS
22### P=5866
1.4.- METODO DE �_�=(�_𝑜
�_�=(�_𝑜
CRECIMIENTO EXPONENCIAL
(2+𝑟𝑡))/((2−𝑟𝑡)
(2+𝑟𝑡))/((2−𝑟𝑡)))

POBLACION
AÑO TOTAL r ESTIMACION POBLACIONAL HASTA 2039
7000
### 3123 0.01694
6500
12### 3827 0.01071
6000
12### 4352 -0.012 5500
2### 4249 0.01525 5000
10### 4949 0.0077 0.0077 4500
1### P=4987 4000
3### P=5065 3500
4### P=5104 3000
1960 1970 1980 1990 2000 2010 2020 2030 2040
2### P=5026 𝑟=l𝑛
𝑟=l𝑛(�_�/�_𝑜
(�_�/�_𝑜 )/𝑡
)/𝑡
AÑOS
22### P=5867

�_�=�_𝑜.𝑒^𝑟𝑡
�_�=�_𝑜.𝑒^𝑟𝑡
1.5.- METODO PARABOLICO 2do GRADO
POBLACION

AÑO TOTAL ESTIMACION POBLACIONAL HASTA 2039


5500
### 3123
12### 3827 5000
12### 4352
4500
2### 4249
10### 4949 4000
1### P=4947
3500
3### P=5046
4### P=5096 3000
1960 1970 1980 1990 2000 2010 2020 2030 2040
2### P=4997
AÑOS
22### P=6003
m m m

a0 =41931.43945 ma0  a1  y i  a 2  y i2   f ( y i )
x  a0  a1. y  a 2. y 2 i 1 i 1 i 1
a1 = -86.2148433 m m m m
a2 =0.033640998 a 0  y i  a1  y i2  a 2  y i3   f ( y i ) y i
i 1 i 1 i 1 i 1
m m m m
a 0  y  a1  y  a 2  y   f ( y i ) y i2
2
i
3
i
4
i
i 1 i 1 i 1 i 1
poblacion futura: P=4918
OS CENSOS
3123
3827
4352
4249
4949

20
2008
STA 2039
0.056
3123 335.09
3827 665627
4352 400000000
4249
4949
4992
5078
5122
030 2040
5035
5898

STA 2039
3123
3827
4352
4249
4949
4988
5066
5106
030 2040
5027
5875

STA 2039
3123
STA 2039

3827
4352
4249
4949
4987
5065
5104
030 2040
5026
5866

STA 2039
3123
3827
4352
4249
4949
4987
5065
5104
030 2040
5026
5867

STA 2039 X Y
3123 POBL AÑO
3827 1 3123 1981
4352 2 3827 1993
4249 3 4352 2005
4949 4 4249 2007
4947 5 4949 2017
5046 20500 10003
5096
030 2040
4997
6003 5 10003 20012773
10003 20012773 4.0041E+10
yi ) 20012773 4.0041E+10 8.0115E+13

 f (y )y
i i
171536291 -171667.65 42.9480745
1 -171667.65 171.800415 -0.04298161
m
42.9480745 -0.0429816 1.07534E-05
 f (y )y
1
i
2
i
DE LAMPA SEGUN LOS CENSOS

0705x^2 + 665626.570870657x - 440740267.468873

DATOS CENSALES

4 1992 2000 2008 2016


ÑOS

453397533
1351104326 -897706793
5.38917E+15
3.23855E+18
-3.2332E+18
Y2 Y3 Y4 X.Y X.Y2
392436177741591411.5401E+13 61866631.2256E+10
397204979162936571.5777E+13 76272111.5201E+10
402002580601501251.6161E+13 87257601.7495E+10
402804980842943431.6225E+13 85277431.7115E+10
406828982057389131.6551E+13 99821332.0134E+10
200127734.0041E+10 8.0115E+13 410495108.2201E+10

20500
41049510
82201102188

41931.48682
-86.2148433
0.033640998
PRIMERO 1. DOTACION Y CONSUMO

Población de diseño 4918

1.1. DOTACION

d= 130

1.2. CONSUMO

1.2.1. CALCULO DE CAUDAL MEDIO (Qp)

P f .d Donde:
Qp  Pf = Población futura
86400 d = Dotación
Qp = Consumo Promedio

Qp= 7.40

1.2.2. CALCULO DE CONSUMO MAXIMO DIARIO

Qmd  K 1 * Qp K1 = 1.30

Qmd = 9.62

1.2.3. CALCULO DE CONSUMO MAXIMO HORARIO

Qmh  K 2 * Qp k2 = 2.50

Qmh = 18.50

1) Determinación del Volumen de Regulacion


HORAS CONSUMO (L/S)
0 20
1 20
2 20 Variación Horaria de Consumo
3 20
250
4 30

200

150
Variación Horaria de Consumo
250

5 60
6 140 200
7 180
8 170 150
9 210
10 210 100
11 230
12 210
50
13 200
14 200
15 190 0
0 5 10 15 20 25
16 180
17 160
18 150
19 130
20 120
21 110
22 100
23 60
24 20

SEGÚN UN CALCULO ANÁLITICO


La ley de demanda o salida (CONSUMO), la conocemos en función de porcentajes horarios del caudal máximo dia
en esta misma forma se expresa la ley de entrada (SUMINISTRO).

Para nuestro casoPara nuestro caso es aplicable por ser un sistema por gravedad

VOLUMENES DE REGULACION PARA EL CASO DE UN SUMINISTRO A LAS 24 HORAS


(Generalmente es sistemas por Gravedad)

HORAS Demanda (salidas)


Suministro
(entrada)
Demanda Diferencias
De A horaria en diferencias acumuladas
%
0 1 130 20 110 110
1 2 130 20 110 220
2 3 130 20 110 330
3 4 130 20 110 440
4 5 130 30 100 540
5 6 130 60 70 610
6 7 130 140 -10 600
7 8 130 180 -50 550
8 9 130 170 -40 510
9 10 130 210 -80 430
10 11 130 210 -80 350
11 12 130 230 -100 250
12 13 130 210 -80 170
13 14 130 200 -70 100
14 15 130 200 -70 30
15 16 130 190 -60 -30
16 17 130 180 -50 -80
17 18 130 160 -30 -110
18 19 130 150 -20 -130
19 20 130 130 0 -130
20 21 130 120 10 -120
21 22 130 110 20 -100
22 23 130 100 30 -70
23 24 130 60 70 0
3120 3120

En este caso el maximo deficit es de 130

Finalmente calculamos el volumen del reservorio con la siguiente formula :

Vol. Res = Qmd [l/s]*(Imax excedente%I+Imax faltante%I)[1m3/1000L]

Datos :
Qmd= 21.96
max exceden 610
max faltante 130

Vol. Reservorio= 585.014 m3

15lts m 3 3600 seg


Vol. Contra Incendios= Vci  * *
s 1000 lts 1hora
El Volúmen contra incendio según reglamento asumido para nuestro caso será de 15 lt/s,
acion

e Consumo
e Consumo

20 25 30

TICO
orarios del caudal máximo diario (Qmd),

A LAS 24 HORAS

Diferencias
acumuladas
+ max.
Deficit

240
350
460
570
670
740
730
680
640
560
480
380
300
230
160
100
50
20
0
0
10
30
60
130

la siguiente formula :

Imax faltante%I)[1m3/1000L][3600s/1h][1/100%]

s m 3 3600 seg
* * = 54 m3/h
1000 lts 1hora

También podría gustarte