Está en la página 1de 10

8.7 8.7 8.7 8.7 8.

7
8.7

8.7

8.7

CALCULO DE CARGAS

TERCER PISO

COLUMNA COLUMNAS
C1 8.45 C1
C2 10.56 C2
PLACA 36.75 55.76 LACA

LOSA

TOTAL 2724.84 2724.84

ALVAÑILERIA

3RO PISO 42.63 42.63

PLACA

TOTAL 36.75 36.75

WD 2859.98

WL 240

SEGUNDO PISO

COLUMNA COLUMNAS
C1 9.22 C1
C2 11.52 C2
PLACA 40.09 60.83 LACA

LOSA

TOTAL 2724.84 2724.84

ALVAÑILERIA

2DO PISO 46.51 46.51

PLACA

TOTAL 40.09 40.09

WD 2872.27

WL 240

PRIMER PISO

COLUMNA COLUMNAS
C1 11.52 C1
C2 14.4 C2
PLACA 50.11 76.03 LACA

LOSA

TOTAL 2724.84 2724.840

ALVAÑILERIA

3RO PISO 58.14 58.14

PLACA

TOTAL 50.11 50.11

WD 2909.12

WL 240

WDtotal 8641.37

WLtotal 720
FUERZA SISMICA �= (����.�)/��

Z= FACOR DE LA ZONA- LIMA ZONA I 1


U=FACTOR DE USO - EDIFICACION TIPO B 1.3
S= FACTOR SUELO II 1.2
C= COEFICIENTE SISMICO

H=ALTURA TOTAL DE LA EDIFICACION


C= 0.8/(𝑇/𝑇�+1) T= 0.05�/√�
DONDE D=DIMENSION DE EDIFICIO CONCIDERANDO L

T= 0.08

C= 0.71

→ C = 0.4 REGLA

Rd =factor ductil edeficacion eje las fuerzas absorven muros de corte o similares (placas )
Rd= 3

valor de P por ser tipo B (u=1.3)

P= 9001.37

H= 1872.28

DISTRIBUCION DE LAS FUERFAS CORTANTES EN LOS NIVELES


𝐴𝐿𝑇�/𝐴𝑁𝐶��>6 𝑓=0.85

0.05 < 3 f=
𝐴𝐿𝑇�/𝐴𝑁𝐶��>3 𝑓=1

N Pi hi pi*hi
3 3125.47 7.6 23753.61 0.00016 0.29
2 2913.06 5.4 15730.54 0.00011 0.21
1 2962.93 3 8888.78 0.00006 0.12
48372.93

F= 𝐼𝑥/𝑀𝐼�
PLACA 1
I1= 10.9751

I2= 0.0058

C1= 0.0021

C2= 0.0208

mIx= 22.150

F= 0.495

F3= 0.146
F2= 0.104
F1= 0.058

DISTRIBUCION DE LAS CARGAS VERTICALES EN CADA NIVEL


ANCHO LARGO ALTURA N DE COLUMNAS YS
0.4 0.4 2.2 10 2.4
0.5 0.5 2.2 8 2.4
8.7 0.2 2.2 4 2.4

ANCHO LARGO ALTURA N DE COLUMNAS YS


0.4 0.4 2.4 10 2.4
0.5 0.5 2.4 8 2.4
8.7 0.2 2.4 4 2.4

ANCHO LARGO ALTURA N DE COLUMNAS YS


0.4 0.4 3 10 2.4
0.5 0.5 3 8 2.4
8.7 0.2 3 4 2.4
TAL DE LA EDIFICACION
N DE EDIFICIO CONCIDERANDO LA FUERZA SISSMICA