Introduction:
The purpose of this experiment was to extract chlorophyll and carotenoid pigments from spinach
leaves using a solvent and to use thin-layer chromatography.
B-Carotene
Procedure:
See attachment.
Elizabeth Ping | October 25, 2011| 2
Observations:
3.0 cm
2.5 cm
Acetaminophen
Salicylamide
Ibuprofen
Reference
Pamprin
Pamprin
Caffeine
Aspirin
Calculations
TLC Plate 1
Drug Distance Solvent Front 𝑹𝒇 Calculation 𝑹𝒇
Traveled
Acetaminophen 7.5 cm 11.6 cm 7.5 𝑐𝑚 0.647
𝑅𝑓 =
11.6 𝑐𝑚
Aspirin 8.5 cm 11.6 cm 8.5 𝑐𝑚 0.733
𝑅𝑓 =
11.6𝑐𝑚
Caffeine 3.0 cm 11.6 cm 3.0 𝑐𝑚 0.2586
𝑅𝑓 =
11.6 𝑐𝑚
Pamprin 7.5 cm 11.6 cm 7.5 𝑐𝑚 0.647
𝑅𝑓 =
11.6 𝑐𝑚
TLC Plate 2
Drug Distance Solvent Front 𝑹𝒇 Calculation 𝑹𝒇
Traveled
Ibuprofen N/A N/A N/A N/A
Salicylamide 11.0 cm 12.0 cm 11.0 𝑐𝑚 0.917
𝑅𝑓 =
12.0 𝑐𝑚
Reference 7.5 cm 12.0 cm 7.5𝑐𝑚 0.625
𝑅𝑓 =
12.0 𝑐𝑚
Elizabeth Ping | October 25, 2011| 3
Conclusions:
Thin layer chromatography was used to find the active ingredients that the over-the-counter
analgesic, Pamprin, contains. It was found that Pamprin contains acetaminophen and caffeine.
This is because the R f values for Pamprin were found to be 0.208 and 0.625 on plate 2 and 0.647
on plate 1. This correlated with the R f values of pure acetaminophen which was 0.647 and pure
caffeine which was 0.2586. The actual components of Pamprin according to the drug label are
acetaminophen, caffeine, and aspirin, and ibuprofen. Ibuprofen was not visualized with either
iodine or UV analysis in the pure form or in Pamprin. Furthermore, even aspirin did not appear
as component of Pamprin in either iodine or UV analysis. Also no spots were seen using the UV
analysis, and therefore R f values were calculated using the spots visualized during the iodine
analysis. All the spots were light to dark yellow-brown in color using iodine analysis.
Compounds of high polarity have R f values (caffeine with a R f value of 0.259) that are less than
polar compounds that have higher R f values (salicylamide, aspirin, and acetaminophen with R f
values all greater than 0.5) that develop on the same plate. This is because compounds that are more
polar interact strongly with the solvent and thus travel a shorter distance on the TLC plate, while
compounds that are less polar interact less strongly to the solvent and thus can travel a longer
distance on the TLC plate. Since only two out of the four possible analgesics were identified during
the TLC analysis, this experiment was a semi-success.
Possible sources of error include the cross-contamination between micropippets, not spotting
enough solution onto the TLC plates, not heating the Pamprin long enough to break down the
binding, and not visualizing the plates under the UV lamp in a dark enough area to see the
formation of spots.
Questions:
References:
Elizabeth Ping | October 25, 2011| 4
Pavia, Donald, Gary Lampman, George Kriz, and Randall Engel. Introduction to Organic
Laboratory Techniques: A Microscale Approach. Belmont: Thomson Brooks, 2007.