Está en la página 1de 11

Qty.

Description
2 TPE 80-170/4 A-F-A-BAQE

Product No.: 99113683

Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump
is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for
maintenance or service while the pump housing remains in the pipework.
The pump is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework
connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2).
The pump is fitted with a fan-cooled, permanent-magnet synchronous motor. The motor efficiency is classified as
IE5 in accordance with IEC 60034-30-2.
The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously
variable control of the motor speed, which again enables adaptation of the performance to a given requirement.

Controls:
Frequency converter: Built-in

Liquid:
Pumped liquid: Heating water
Liquid temperature range: 0 .. 120 °C
Density at selected liquid temperature: 965.3 kg/m³

Technical:
Pump speed on which pump data are based: 1455 rpm
Actual calculated flow: 82.8 m³/h
Resulting head of the pump: 11 m
Actual impeller diameter: 219 mm
Primary shaft seal: BAQE
Curve tolerance: ISO9906:2012 3B

Materials:
Pump housing: Cast iron
EN-JL1040
ASTM A48-40 B
Impeller: Cast iron
EN-JL1030
ASTM A48-30 B

Installation:
Range of ambient temperature: -20 .. 50 °C
Maximum operating pressure: 16 bar
Flange standard: DIN
Pipe connection: DN 80
Pressure rating: PN 16
Port-to-port length: 500 mm
Flange size for motor: FF215

Electrical data:
Motor type: 112ME
IE Efficiency class: IE5
Rated power - P2: 4 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-500 V
Rated current: 7.70-6.00 A
Requested voltage: 400 V
Rated current at this voltage: 7.42 A

Printed from Grundfos Product Centre [2019.02.002] 1/11


Qty. Description
Cos phi - power factor: 0.92-0.87
Rated speed: 180-2200 rpm
Efficiency: 90.3%
Motor efficiency at full load: 90.3 %
Enclosure class (IEC 34-5): IP55
Insulation class (IEC 85): F
Motor No: 98971183

Others:
Minimum efficiency index, MEI ≥: 0.70
ErP status: EuP Standalone/Prod.
Net weight: 88 kg
Gross weight: 107 kg
Shipping volume: 0.39 m³
Country of origin: HU
Custom tariff no.: 84137051

Printed from Grundfos Product Centre [2019.02.002] 2/11


99113683 TPE 80-170/4 A-F-A-BAQE 50 Hz
H 2 x TPE 80-170/4, 3*380 V, 50Hz eta
[m] [%]
None
Losses in fittings and valves not included
Q = 82.8 m³/h
H = 11 m
n = 96 % / 1404 rpm
Pumped liquid = Heating water
20 109 % Density = 965.3 kg/m³

18

100 %
16

14
90 %

12

80 %

10 100

70 %
8 80

60 %
6 60

50 %
4 40

40 %

2 20
25 %
20 % Eta pump = 70.8 %
Eta pump+motor+freq.converter = 64.2 %
0 0
0 20 40 60 80 100 120 140 160 Q [m³/h]
P NPSH
[kW] [m]

10 10

P1 (motor+freq.converter)

8 8
P2

6 6

4 4

2 2

P1 (motor+freq.converter) = 3.725 kW
P2 = 3.381 kW
NPSH = 3.33 m
0 0

Printed from Grundfos Product Centre [2019.02.002] 3/11


H 2 x TPE 80-170/4, 3*380 V, 50Hz eta
Description Value [m] [%]
None
General information: Losses in fittings and valves not included
TPE 80-170/4 Q = 82.8 m³/h
Product name: A-F-A-BAQE 20 109 % H = 11 m
n = 96 % / 1404 rpm
Product No: 99113683 18 Pumped liquid = Heating water
Density = 965.3 kg/m³
EAN number: 5712607014148 100 %
Technical: 16
Pump speed on which pump data are
based: 1455 rpm 14 90 %
Actual calculated flow: 82.8 m³/h
12
Resulting head of the pump: 11 m 80 %
Head max: 170 dm 10 100
Actual impeller diameter: 219 mm 70 %
Primary shaft seal: BAQE 8 80

Curve tolerance: ISO9906:2012 3B 60 %


6 60
Pump version: A
50 %
Model: A 4 40
Materials: 40 %

Pump housing: Cast iron 2 20


25 % Eta pump = 70.8 %
20 %
EN-JL1040 Eta pump+motor+freq.converter = 64.2 %
0 0
ASTM A48-40 B 0 20 40 60 80 100 120 140 Q [m³/h]
Impeller: Cast iron P NPSH
[kW] [m]
EN-JL1030 10 10
ASTM A48-30 B P1 (motor+freq.converter)
Material code: A 8
P2
8
Installation:
Range of ambient temperature: -20 .. 50 °C 6 6

Maximum operating pressure: 16 bar


4 4
Flange standard: DIN
Pipe connection: DN 80 2 P1 (motor+freq.converter) = 3.725 kW 2
Pressure rating: PN 16 P2 = 3.381 kW
NPSH = 3.33 m
Port-to-port length: 500 mm 0 0
Flange size for motor: FF215 M16

Rp 1/4
250

500
187
162

80

191.3
145.5

201

Connect code: F 201 201


201
Liquid:
191.3
145.5 145.5
Pumped liquid: Heating water
Liquid temperature range: 0 .. 120 °C
Density at selected liquid temperature: 965.3 kg/m³
Electrical data:
653

Motor type: 112ME


Rp 1/4
204

IE Efficiency class: IE5


Rated power - P2: 4 kW
115

Mains frequency: 50 Hz 80
0

187 162 500


Rated voltage: 3 x 380-500 V
Rated current: 7.70-6.00 A M16

Requested voltage: 400 V


144

Rated current at this voltage: 7.42 A


Cos phi - power factor: 0.92-0.87
250
Rated speed: 180-2200 rpm
Efficiency: 90.3%
Motor efficiency at full load: 90.3 %
Enclosure class (IEC 34-5): IP55 L1

L2
L1

L2
L3 L3

Insulation class (IEC 85): F PE

Motor protec: YES NC

C1

Motor No: 98971183


NO

NC

C2

Controls: OC DI
NO

18 GND
+24 V*
11 DI4/OC2

Control panel: HMI200 - Standard 19

17
Pt100/1000

Pt100/1000
12 AO

Function Module: FM300 - Advanced +24 V* +24 V* +24 V*/5 V* +5 V* 9


14
GND

AI3
1 DI2

Frequency converter: Built-in 21


20
LiqTec
GND

Others: +24 V*
OC
GND
DI
22

10
LiqTec

DI3/OC1

4 AI1

Minimum efficiency index, MEI ≥: 0.70 +24 V* +24 V* +24 V*/5 V* 2
5
DI1
+5 V
6 GND

ErP status: EuP Standalone/Prod. A


Y
GENIbus A

GENIbus Y

B GENIbus B

Net weight: 88 kg 3
15
GND

+24 V
8 +24 V

Gross weight: 107 kg 26


23
+5 V

GND
25 GDS TX

Shipping volume: 0.39 m³


+24 V* +24 V* +24 V*/5 V*
24 GDS RX
+5 V* 7 AI2

Printed from Grundfos Product Centre [2019.02.002] 4/11


Description Value
Config. file no: 99100731
Country of origin: HU
Custom tariff no.: 84137051

Printed from Grundfos Product Centre [2019.02.002] 5/11


99113683 TPE 80-170/4 A-F-A-BAQE 50 Hz
cos phi TPE80-170/4 + 112ME 4 kW 3*380 V, 50 Hz I
eta [A]

eta
cos phi

0.8 8

0.6 6

0.4 4

0.2 2

0.0 0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 P2 [kW]
n P1
[rpm] [kW]
P1 (motor+freq.converter)

1600 4.0
n

1200 3.0

800 2.0

400 1.0

n = 109 %
0 0.0

Printed from Grundfos Product Centre [2019.02.002] 6/11


99113683 TPE 80-170/4 A-F-A-BAQE 50 Hz

201 201

201

191.3
145.5 145.5

653
Rp 1/4

80 204
115
0
187 162 500

M16
144

250

Note! All units are in [mm] unless others are stated.


Disclaimer: This simplified dimensional drawing does not show all details.

Printed from Grundfos Product Centre [2019.02.002] 7/11


99113683 TPE 80-170/4 A-F-A-BAQE 50 Hz

L1 L1
L2 L2
L3 L3
PE

NC
C1
NO

NC
C2
NO

18 GND
OC DI
+24 V*
11 DI4/OC2

19 Pt100/1000

17 Pt100/1000
12 AO

+24 V* +24 V*/5 V* +5 V* 9 GND


+24 V*
14 AI3
1 DI2

21 LiqTec
20 GND
22 LiqTec
OC DI
+24 V* GND
10 DI3/OC1
4 AI1
+24 V* +24 V* +24 V*/5 V* 2 DI1
5 +5 V
6 GND
A GENIbus A
Y GENIbus Y
B GENIbus B

3 GND
15 +24 V
8 +24 V
26 +5 V
23 GND
25 GDS TX
+24 V* +24 V* +24 V*/5 V*
24 GDS RX
+5 V* 7 AI2

Note! All units are in [mm] unless others are stated.

Printed from Grundfos Product Centre [2019.02.002] 8/11


99113683 TPE 80-170/4 A-F-A-BAQE 50 Hz
Input Sizing result
General Type TPE 80-170/4
Application Heating Quantity 2
Application area District heating Motor 4 kW
Installation type Distribution Flow 82.8 m³/h
Installation Main circulator - Head 11 m
flow or return Min.inlet pressure 1.49 bar ( 120 °C, against
Flow (Q) 82.8 m³/h atmosphere)
Head (H) 11 m Power P1 3.725 kW
BMS connectivity No Power P2 required in the duty 3.381 kW
Prefer fast delivery No point
Your requirements Eta pump 70.8 %
Pumped liquid Heating water Eta motor 90.8 %
Min. liquid temperature 20 °C Eta pump+motor 64.2 % =Eta pump * Eta
Max. liquid temperature 120 °C motor
Liquid temperature during operation 90 °C Eta total 64.2 % =Eta relative to the
Max. operation pressure 16 bar duty point
Min. inlet pressure 1.5 bar Energy consumption 9158 kWh/Year
Allowed flow undersize 10 % CO2 emission 5900 kg/Year
Price 9.372,17 EUR
Control mode Life cycle cost 42295 EUR /15Years
Control mode Prop. pressure H eta
2 x TPE 80-170/4, 3*380 V, 50Hz
Decrease at low flow 50 % [m] [%]
None
Enclosure class IP20 Losses in fittings and valves not included
Remote controlled by external controller No Q = 82.8 m³/h
20 109 % H = 11 m
n = 96 % / 1404 rpm
Edit load profile Pumped liquid = Heating water
18 Density = 965.3 kg/m³
Heating season 285 days
100 %
Load profile Standard profile 16
Reduced night-time duty No
14 90 %
Configuration
Select type of hydraulic Parallel 12
Total number of pumps 2 80 %

Of these: number of standby pumps 1 10 100

70 %
Pump design 8 80

Pump material Cast iron or 60 %


stainless steel 6 60

50 %
Operational conditions 4 40
40 %
Frequency 50 Hz
2 20
Phase 1 or 3 25 %
20 % Eta pump = 70.8 %
Min. power limit for SD start 5.5 kW Eta pump+motor+freq.converter = 64.2 %
0 0
Voltage 1 x 230 or 3 x 400 V 0 20 40 60 80 100 120 140 160 Q [m³/h]
P NPSH
[kW] [m]
Ambient temperature 20 °C
Hit list settings 10 10
Energy price 0.15 EUR/kWh P1 (motor+freq.converter)

Increase of energy price 6% P2


Calculation period 15 years
5 5

Load Profile
P1 (motor+freq.converter) = 3.725 kW
1 2 3 4 P2 = 3.381 kW
NPSH = 3.33 m
Flow 100 75 50 25 % 0 0
Head 100 88 75 63 %
P1 3.725 2.314 1.334 0.685 kW
Eta total 64.2 67.9 67.2 54.6 %
Time 410 1026 2394 3010 h/a
Energy consumption 1527 2374 3194 2062 kWh/Year
Quantity 1 1 1 1

Printed from Grundfos Product Centre [2019.02.002] 9/11


Installation and Input Sizing Results
Flow (Q): 82.8 m³/hHead (H): 11 m Product number: 99113683
Max. operation pressure: 16 bar Type: TPE 80-170/4
Min. inlet pressure: 1.5 bar Quantity: 2
Motor: 4 kW
Flow: 82.8 m³/h
Head: 11 m
Power P1: 3.725 kW
Eta pump: 70.8 %
Eta pump+motor: 64.2 % =Eta pump * Eta motor
Eta total: 64.2 % =Eta relative to the duty
point
Energy consumption: 9158 kWh/Year
CO2 emission: 5900 kg/Year
Price: 9.372,17 EUR

Pump Curve Dimensional Drawing


H 2 x TPE 80-170/4, 3*380 V, 50Hz eta
[m] [%]
None
Losses in fittings and valves not included
Q = 82.8 m³/h 201 201
H = 11 m
20 109 % 201
n = 96 % / 1404 rpm
Pumped liquid = Heating water
Density = 965.3 kg/m³ 191.3
18 145.5 145.5
100 %
16

14
90 %

12
80 %
653

10 100

70 %
8 80 Rp 1/4
204

60 %
6 60
115

50 %
4 40
40 % 80
0

2 20
25 % 187 162 500
20 % Eta pump = 70.8 %
Eta pump+motor+freq.converter = 64.2 %
0 0
0 20 40 60 80 100 120 140 160 Q [m³/h]
P NPSH
[kW] [m] M16

10 10
P1 (motor+freq.converter)
144

8 8
P2

6 6

250
4 4

2 2
P1 (motor+freq.converter) = 3.725 kW
P2 = 3.381 kW
NPSH = 3.33 m
0 0

Printed from Grundfos Product Centre [2019.02.002] 10/11


Load profile
Q
[m³/h]
82.8

62.1

41.4

20.7

410 1,436 3,830 6,840 t


[h]

1 2 3 4
Flow 100 75 50 25 %
Head 100 88 75 63 %
P1 3.725 2.314 1.334 0.685 kW
Eta total 64.2 67.9 67.2 54.6 %
Time 410 1026 2394 3010 h/a
Energy consumption 1527 2374 3194 2062 kWh/Year
Quantity 1 1 1 1

Total head 11 m

Dimensioning flow 82.8 m³/h

Printed from Grundfos Product Centre [2019.02.002] 11/11