Está en la página 1de 40

SONI AUTO & ALLIED INDUSTRI

INDUSTRIAL AREA , GA
MIS FOR NEW H & T
DATE: 03.02.2019
SL. NO CHECK POINTS

1 FURNACE CONDITION

2 CONDITION OF THE QUENCHING MACHINE

3 QUENCHING OIL START TEMPRETURE

WHEN QUENCHING OIL TEMPRETURE 75°C THEN


4 START
HEAT EXCHANGER

5 GAS CONSUMPTION PER TONNE


6 TOTAL RUNNING HOURS

7 HARDNESS AFTER HARDENING & TEMPERING

8
PARABOLIC TEMPRETURE
(TEMPERING TEMP. ) -460°C , VFD- 28

9 BREAK DOWN DETAILS (HOURS)

10 FLOW METER READING FOR (HARDING FURANCE )

11 FLOW METER READING FOR (TEMERING FURANCE )

CHECKED BY:
SONI AUTO & ALLIED INDUSTRIES LTD. (UNIT-II)
INDUSTRIAL AREA , GAMHARIA
MIS FOR NEW H & T

ACTUAL FOUND REMARK

OK

OK

52 ° C

NO
HF- 23.27 KG/ TONEE, TF- 8.18 KG/TONEE
HF-21 HOURS , TF- 23 HOYRS

2.4 , 3.1

NO

HF- 99600 TO 100351 KG,

TF- 28287 TO 28551 KG


APPROVED BY:
SONI AUTO & ALLIE
INDUSTRIA
MIS FO
DATE: 03.02.2019
SL. NO CHECK POINTS

1 FURNACE CONDITION

2 CONDITION OF THE QUENCHING MACHINE

3 QUENCHING OIL START TEMPRETURE

WHEN QUENCHING OIL TEMPRETURE 75°C THEN


4 START
HEAT EXCHANGER

5 GAS CONSUMPTION PER TONNE

6 TOTAL RUNNING HOURS

7 HARDNESS AFTER HARDENING & TEMPERING

8
PARABOLIC TEMPRETURE
(TEMPERING TEMP. ) -460°C , VFD- 28

9 BREAK DOWN DETAILS (HOURS)

10 FLOW METER READING FOR (HARDING FURANCE )


11 FLOW METER READING FOR (TEMERING FURANCE )

CHECKED BY:
AUTO & ALLIED INDUSTRIES LTD. (UNIT-II)
INDUSTRIAL AREA , GAMHARIA
MIS FOR NEW H & T

ACTUAL FOUND

OK

OK

52 ° C

NO
HF- 33.054 KG/ TONEE, TF- 7.054 KG/TONEE

HF-17 HOURS , TF- 20 HOURS

2.4 , 3.1

NO

HF- 100351 TO 101369 KG,


TF- 28551 TO 28845 KG
APPROVED BY:
REMARK
SONI AUTO & ALLIE
INDUSTRIA
MIS FO
DATE: 03.02.2019
SL. NO CHECK POINTS

1 FURNACE CONDITION

2 CONDITION OF THE QUENCHING MACHINE

3 QUENCHING OIL START TEMPRETURE

WHEN QUENCHING OIL TEMPRETURE 75°C THEN


4 START
HEAT EXCHANGER

5 GAS CONSUMPTION PER TONNE

6 TOTAL RUNNING HOURS

7 HARDNESS AFTER HARDENING & TEMPERING

8
PARABOLIC TEMPRETURE
(TEMPERING TEMP. ) -460°C , VFD- 28

9 BREAK DOWN DETAILS (HOURS)

10 FLOW METER READING FOR (HARDING FURANCE )


11 FLOW METER READING FOR (TEMERING FURANCE )

CHECKED BY:
AUTO & ALLIED INDUSTRIES LTD. (UNIT-II)
INDUSTRIAL AREA , GAMHARIA
MIS FOR NEW H & T

ACTUAL FOUND

OK

OK

52 ° C

NO
HF- 29.854 KG/ TONEE, TF- 6.984 KG/TONEE

HF-16 HOURS , TF- 19 HOURS

2.4 , 3.1

NO

HF- 101369 TO 101988 KG,


TF- 28845 TO 29063 KG
APPROVED BY:
REMARK
SONI AUTO & ALLIE
INDUSTRIA
MIS FO
DATE: 03.02.2019
SL. NO CHECK POINTS

1 FURNACE CONDITION

2 CONDITION OF THE QUENCHING MACHINE

3 QUENCHING OIL START TEMPRETURE

WHEN QUENCHING OIL TEMPRETURE 75°C THEN


4 START
HEAT EXCHANGER

5 GAS CONSUMPTION PER TONNE

6 TOTAL RUNNING HOURS

7 HARDNESS AFTER HARDENING & TEMPERING

8
PARABOLIC TEMPRETURE
(TEMPERING TEMP. ) -460°C , VFD- 28

9 BREAK DOWN DETAILS (HOURS)

10 FLOW METER READING FOR (HARDING FURANCE )


11 FLOW METER READING FOR (TEMERING FURANCE )

CHECKED BY:
AUTO & ALLIED INDUSTRIES LTD. (UNIT-II)
INDUSTRIAL AREA , GAMHARIA
MIS FOR NEW H & T

ACTUAL FOUND

OK

OK

52 ° C

NO
HF- 29.67 KG/ TONEE & NIGHT- 24.22 KG/ TONEE,
TF- 7.93 KG/TONEE
HF-16 HOURS , TF- 19 HOURS

2.4 , 3.1

NO
HF- 102151 KG TO 102746 KG& NIGHT HF-102746
TO 103161 KG
TF- 29063 TO 29358 KG
APPROVED BY:
REMARK
SONI AUTO & ALL
INDUSTRIA
MIS FO
DATE: 03.02.2019
SL. NO CHECK POINTS

1 FURNACE CONDITION

2 CONDITION OF THE QUENCHING MACHINE

3 QUENCHING OIL START TEMPRETURE

4 MODEL(DAY)

5 MODEL(NIGHT)

5 GAS CONSUMPTION PER TONNE

6 TOTAL RUNNING HOURS


7 HARDNESS AFTER HARDENING & TEMPERING

8
PARABOLIC TEMPRETURE
(TEMPERING TEMP. ) -460°C , VFD- 28

9 BREAK DOWN DETAILS (HOURS)

10 FLOW METER READING FOR (HARDING FURANCE )

11 FLOW METER READING FOR (TEMERING FURANCE )

CHECKED BY:
AUTO & ALLIED INDUSTRIES LTD. (UNIT-II)
INDUSTRIAL AREA , GAMHARIA
MIS FOR NEW H & T

ACTUAL FOUND

OK

OK

52 ° C

2515/R-(ML-74 , 2L-76 3L-124, 4L-124,5L-124,6L-


124,7L-124)
5066/R-(3L-98, 4L- 98,5L-100,6L-100, 7L-100)
& 2515/F-(ML-70)
5066/R(ML-199 , 2L-199 ) 2515/R(3L-
76, 4L-76,5L-76,6L-76,7L-76)

HF- 27.09 KG/ TONEE(DAY)


HF- 32.887 KG/ TONEE(NIGHT)
TF- 8.68 KG/TONEE(DAY)
TF- 9.15 KG/ TONEE(NIGHT)

HF-15 HOURS , TF- 18 HOURS


2.4 , 3.1

NO
HF-103161 TO 103601 KG(DAY)
HF-103601 TO 10392 KG(NIGHT)
TF-29358 TO 29499 KG (DAY)
TF-29499 TO 29653 KG(NIGHT)
APPROVED BY:
REMARK
SONI AUTO & ALL
INDUSTRIA
MIS FO
DATE: 09.02.2019
SL. NO CHECK POINTS

1 FURNACE CONDITION

2 CONDITION OF THE QUENCHING MACHINE

3 QUENCHING OIL START TEMPRETURE

4 MODEL(DAY)

5 MODEL(NIGHT)

5 GAS CONSUMPTION PER TONNE

7 HARDNESS AFTER HARDENING & TEMPERING


8
PARABOLIC TEMPRETURE
(TEMPERING TEMP. ) -460°C , VFD- 28

9 BREAK DOWN DETAILS (HOURS)

10 FLOW METER READING FOR (HARDING FURANCE )

11 FLOW METER READING FOR (TEMERING FURANCE )

CHECKED BY:
AUTO & ALLIED INDUSTRIES LTD. (UNIT-II)
INDUSTRIAL AREA , GAMHARIA
MIS FOR NEW H & T

ACTUAL FOUND

OK

OK

52 ° C

VFJ/F- ML-150 , 2L-147 ,3L-150 ,4L-150,5L-150,6L-150


5066/R-3L-152,4L-152,5L-150,6L-150,ML-62,2L-60

5066/R-ML-120NOS,2L-120,3L-46,4L- 46,5L-44,6L-44,
2515/R 3L-188 ,4L-188,5L-188,6L-188,7L-
188,PARABOLIC-94

HF(DAY)-31.97 KG,NIGHT-29.27 TF-9.77 (DAY), TF-


(NIGHT)-12.14 KG

2.4 , 3.1
NO
HF-103923 TO 104451 KG(DAY)
HF-104451 TO 104974 KGKG(NIGHT)
TF-29563 TO 29817 KG (DAY)
TF-29817 TO 29987 KG(NIGHT)
APPROVED BY:
REMARK
SONI AUTO & ALL
INDUSTRIA
MIS FO
DATE: 10.02.2019
SL. NO CHECK POINTS

1 FURNACE CONDITION

2 CONDITION OF THE QUENCHING MACHINE

3 QUENCHING OIL START TEMPRETURE

4 MODEL(DAY)

5 MODEL(NIGHT)

5 GAS CONSUMPTION PER TONNE

7 HARDNESS AFTER HARDENING & TEMPERING


8
PARABOLIC TEMPRETURE
(TEMPERING TEMP. ) -460°C , VFD- 28

9 BREAK DOWN DETAILS (HOURS)

10 FLOW METER READING FOR (HARDING FURANCE )

11 FLOW METER READING FOR (TEMERING FURANCE )

CHECKED BY:
AUTO & ALLIED INDUSTRIES LTD. (UNIT-II)
INDUSTRIAL AREA , GAMHARIA
MIS FOR NEW H & T

ACTUAL FOUND

OK

OK

52 ° C

5066/R -ML-100, 2L-100, 3L-150,4L-148,5L-150,6L-148

0120/F-ML-200,2L-200,3L-200,4L-198,5L-200,6L-
200,7L-200

HF(DAY)-23.95 KG,NIGHT-27.846 TF-9.927 (DAY), TF-


(NIGHT)- 8.845 KG

2.4 , 3.1
NO
HF-104974 TO 105225 KG(DAY)
HF-105225 TO 105639 KG(NIGHT)
TF-29987 TO 30091 KG (DAY)
TF-30091 TO 30232 KG(NIGHT)
APPROVED BY:
REMARK