Test performed by: Dr. A. F. aiful Amin, Professor, Dept. of Civil Engg.
Important Notes: Samples as supplied to us have been tested in our laboratory. BRTC does not have any responsibility as to the representative character of the samples required to be tested. It is recommended that the
samples are sent in a secure and sealed cover/packet/container under signature of the competent authority. In order to avoid fraudulent fabrication of test results, it is recommended that all test reports be collected by duly
authorized person, and not by the Contractor/Supplier.
Page 1/2
BANGLADESH UNIVERSITY OF ENGINEERING AND TECHNOLOGY (BUET)
DEPARTMENT OF CIVIL ENGINEERING
•
MObile: 01819 557 964; PABX: 9665650-80 Ext. 7226; www.buet.ac.bd/ce/
STRENGTH OF MATERIALS LABORATORY
TENSION TEST OF DEFORMED M.S. BARS BRTC No.: 1100·722821CEl14·15; Dt.15/10/2014
Sent by: Col. Towficur Rahman(Rtd), Sr. General Manager(Marketing& Sales), Ratanpur Steel Re-rolling Mills Ltd., Ref.: RSRM/BUET (BRTC)/400W&500W-8/14; oi 15/1012014
Nahar Mansion, 116 CDA Avenue, Muradpur, Chittagong Date of Test: 16/10/2014
Project: Test of deformed MS bars for RSRM Contractor: -
SI. Frog Nominal Actual Actual Average Yield or Yield or Average Ultimate Ultimate Average TS/yS Elongation Average Bend Rebend
No. Mark Oia Dia Unit Actual Proof Proof Yield or Proof Load Strength "If
Ultimate (%) Elongation Test Test
Weight Unit Load Strength "If
Strength Strength (Gauge (%)
Weight (YS) (TS) length = (G. length =
mm mm kg/m kg/m kN MPa MPa kN MPa MPa 203.2 mm) 203.2 mm) (ISO 6935) (ISO 6935)
.~~
~.Q-
N/mm2or N/mm2or 40 40000 (2810) 70000 (4910) 300 300 (3050) 500 (5090) 11 12
INom. Area. (sq.mm) 11257180416161491138013141201 1131791501 MPa MPa
%
60 60000 (4210) 90000 (6310) 420 420 (4275) 620 (6295) 9 g 8 7
300 330 16 75 75000 (5255) 100000 (7015) 520 520 (5275) 690(7010) 7- 7 6
Sampleswerereceivedin unsealedcondition
. 400
500
440
550
14
14
+ For 19 mm bar only .
(~. -~
S·J(
\
<, ~ m
~
{J {f\
\-n,.' :;;:a./
'a.n c:::.. to •• II c "\ f'A....- ,\J
/'
Countersigned by: Dr. Abu Siddique, Professor, Dept. of Civil Engg.
~
~U~
Test performed by: Dr. A. F. M. Saifl min, Professor, Dept. of Civil Engg.
Important Notes: Samples as supplied to us have been tested in our laboratory. BRTC does not have any responsibility as to the representative character of the samples required to be tested. It is recommended that the
samples are sent in a secure and sealed cover/packet/container under signature of the competent authority. In order to avoid fraudulent fabrication of test results, it is recommended that all test reports be collected by duly
authorized person, and not by the Contractor/Supplier.