BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 1 of 20

MINIMUM WALL FOR BSR STANDARD SERVICE

MATERIAL FOR ALL PARTS: AISI 1040


CWP: 6000 psi.
STANDARD SERVICE ONLY
3/4" PIECE A B C D E F
As Manufactured 1.013 in. 0.170 in. 0.433 in. 0.245 in. 0.866 in. 0.432 in.
Max Dimension 1.209 in. 0.121 in. 0.147 in. 0.147 in. 1.459 in. 0.146 in.

1" PIECE A B C D E F
As is Dimension 1.013 in. 0.170 in. 0.433 in. 0.245 in. 0.866 in. 0.432 in.
Max Dimension 1.209 in. 0.121 in. 0.208 in. 0.147 in. 1.458 in. 0.146 in.

1 1/4" PIECE A B C D E F
As Manufactured 1.408 in. 0.260 in. 0.460 in. 0.276 in. 1.457 in. 0.530 in.
Max Dimension 1.668 in. 0.167 in. 0.139 in. 0.146 in. 2.098 in. 0.209 in.

1 1/2" PIECE A B C D E F
As Manufactured 1.375 in. 0.260 in. 0.340 in. 0.276 in. 1.695 in. 0.411 in.
Max Dimension 1.668 in. 0.166 in. 0.138 in. 0.129 in. 2.098 in. 0.209 in.

2" PIECE A B C D E F
As Manufactured 2.000 in. 0.300 in. 0.570 in. 0.400 in. 2.160 in. 0.495 in.
Max Dimension 2.292 in. 0.229 in. 0.337 in. 0.254 in. 2.626 in. 0.262 in.

3" PIECE A B C D E F
As is Dimension 2.964 in. 0.500 in. 0.653 in. 0.400 in. 3.195 in.
Max Dimension 3.304 in. 0.330 in. 0.374 in. 0.230 in. 3.752 in.

4" PIECE A B C D E F
As is Dimension 4.000 in. 0.500 in. 0.597 in. 0.495 in. 4.187 in.
Max Dimension 4.168 in. 0.416 in. 0.448 in. 0.411 in. 4.486 in.
Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 2 of 20

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 3 of 20

MINIMUM WALL FOR SWIVEL JOINTS

MATERIAL FOR 2" & 3" PARTS: AISI 8620 AND 4715
STANDARD SERVICE
2" 1502 TLR PIECES #1,#2,,#5,#7,#14 2" 1502 TLR PIECE #11
2" 1502 INTEGRAL LONG RADIUS ELBOW
OD 3.150 in. B* Max. ID B (MIN) OD 2.840 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.700 in. 2.402 in. 0.374 in. ID (A) 1.750 in. 0.545 in. 2.165 in. 0.337 in.
CWP 15000 psi. *AS MANUFACTURED CWP 15000 psi. *AS MANUFACTURED

2" 1502 TLR PIECE #8 & #10 2" 1502 TLR PIECE #9
OD 2.844 in. B* Max. ID B (MIN) OD 2.985 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.547 in. 2.169 in. 0.338 in. ID (A) 1.750 in. 0.618 in. 2.276 in. 0.354 in.
CWP 15000 psi. *AS MANUFACTURED CWP 15000 psi. *AS MANUFACTURED
3" 1502 TLR PIECE #2 & #7 3" 1502 TLR PIECE #11
3" 1502 INTEGRAL LONG RADUIS ELBOW
OD 4.325 in. B* Max. ID B (MIN) OD 4.850 in. B* Max. ID B (MIN)
ID (A) 2.625 in. 0.600 in. 3.298 in. 0.514 in. ID (A) 2.750 in. 1.050 in. 3.698 in. 0.576 in.
CWP 15000 psi. *AS MANUFACTURED CWP 15000 psi. *AS MANUFACTURED

3" 1502 TLR PIECE #8 & #10 3" 1502 TLR PIECE #9
OD 4.105 in. B* Max. ID B (MIN) OD 4.375 in. B* Max. ID B (MIN)
ID (A) 2.750 in. 0.678 in. 3.130 in. 0.487 in. ID (A) 2.750 in. 0.813 in. 3.336 in. 0.520 in.
CWP 15000 psi. *AS MANUFACTURED CWP 15000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 4 of 20

MINIMUM WALL FOR SWIVEL JOINTS

MATERIAL FOR 2" & 3" PARTS: AISI 8620 AND 4715
STANDARD SERVICE
2" 602 TLR PIECES #1,#2,#5,#7,#14 2" 602 TLR PIECE #11
2" 602 INTEGRAL LONG RADIUS ELBOW
OD 3.150 in. B* Max. ID B (MIN) OD 2.840 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.700 in. 2.832 in. 0.159 in. ID (A) 1.750 in. 0.545 in. 2.554 in. 0.143 in.
CWP 6000 psi. *AS MANUFACTURED CWP 6000 psi. *AS MANUFACTURED
2" 602 TLR PIECE #8
OD 2.844 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.547 in. 2.557 in. 0.143 in.
CWP 6000 psi. *AS MANUFACTURED

3" 602 TLR PIECE #1, #2, #5, #7, #14 3" 602 TLR PIECE #11
3" 602 INTEGRAL LONG RADUIS ELBOW
OD 4.325 in. B* Max. ID B (MIN) OD 4.850 in. B* Max. ID B (MIN)
ID (A) 2.625 in. 0.600 in. 3.889 in. 0.218 in. ID (A) 2.750 in. 1.050 in. 4.361 in. 0.245 in.
CWP 6000 psi. *AS MANUFACTURED CWP 6000 psi. *AS MANUFACTURED
3" 602 TLR PIECE #8 & #10 3" 602 TLR PIECE #9
OD 4.100 in. B* Max. ID B (MIN) OD 4.375 in. B* Max. ID B (MIN)
ID (A) 2.750 in. 0.675 in. 3.687 in. 0.207 in. ID (A) 2.750 in. 0.813 in. 3.934 in. 0.221 in.
CWP 6000 psi. *AS MANUFACTURED CWP 6000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 5 of 20

MINIMUM WALL FOR SWIVEL JOINTS

MATERIAL FOR 2" & 3" PARTS: AISI 8620 AND 4715
STANDARD SERVICE
2" 1002 TLR PIECES #1,#2,#5,#7,#14 2" 1002 TLR PIECE #11
2" 1002 INTEGRAL LONG RADIUS ELBOW
OD 3.150 in. B* Max. ID B (MIN) OD 2.840 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.700 in. 2.635 in. 0.257 in. ID (A) 1.750 in. 0.545 in. 2.376 in. 0.232 in.
CWP 10000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED
2" 1002 TLR PIECE #8
OD 2.844 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.547 in. 2.379 in. 0.232 in.
CWP 10000 psi. *AS MANUFACTURED

3" 1002 TLR PIECE #2, #7 3" 1002 TLR PIECE #11
3" 1002 INTEGRAL LONG RADUIS ELBOW
OD 4.325 in. B* Max. ID B (MIN) OD 4.850 in. B* Max. ID B (MIN)
ID (A) 2.625 in. 0.600 in. 3.619 in. 0.353 in. ID (A) 2.750 in. 1.050 in. 4.058 in. 0.396 in.
CWP 10000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

3" 1002 TLR PIECE #8 & #10 3" 1002 TLR PIECE #9
OD 4.100 in. B* Max. ID B (MIN) OD 4.375 in. B* Max. ID B (MIN)
ID (A) 2.750 in. 0.675 in. 3.430 in. 0.335 in. ID (A) 2.750 in. 0.813 in. 3.660 in. 0.357 in.
CWP 10000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 6 of 20

MINIMUM WALL FOR SWIVEL JOINTS

MATERIAL FOR 4" PARTS: AISI 8620 AND 4715


STANDARD SERVICE
4" 1002 TLR PIECES #2, #7, & #9 4" 1002 TLR PIECE #11
4" 1002 INTEGRAL LONG RADIUS ELBOW
OD 5.450 in. B* Max. ID B (MIN) OD 5.350 in. B* Max. ID B (MIN)
ID (A) 3.750 in. 0.850 in. 4.560 in. 0.445 in. ID (A) 3.750 in. 0.800 in. 4.476 in. 0.437 in.
CWP 10000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

4" 1002 TLR PIECE #8 & #10


OD 5.000 in. B* Max. ID B (MIN)
ID (A) 3.750 in. 0.625 in. 4.183 in. 0.408 in.
CWP 10000 psi. *AS MANUFACTURED
4" 1502 TLR PIECE #2, #7, & #9 4" 1502 TLR PIECE #8, #10, & #11
4" 1502 INTEGRAL LONG RADUIS ELBOW
OD 5.450 in. B* Max. ID B (MIN) OD 5.350 in. B* Max. ID B (MIN)
ID (A) 3.500 in. 0.975 in. 4.156 in. 0.647 in. ID (A) 3.500 in. 0.925 in. 4.079 in. 0.635 in.
CWP 15000 psi. *AS MANUFACTURED CWP 15000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 7 of 20

MINIMUM WALL FOR SWIVEL JOINTS

MATERIAL FOR 2" & 3" PARTS: AISI 8620 AND 4715
SOUR SERVICE (H2S)
2" 1502 TLH PIECES #1,#2,#5,#7,#14 2" 1502 TLH PIECE #11
2" 1502 INTEGRAL LONG RADIUS ELBOW
OD 3.150 in. B* Max. ID B (MIN) OD 2.840 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.700 in. 2.572 in. 0.289 in. ID (A) 1.750 in. 0.545 in. 2.319 in. 0.261 in.
CWP 10000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED
2" 1502 TLH PIECE #8 & #10 2" 1502 TLH PIECE #9
OD 2.844 in. B* Max. ID B (MIN) OD 2.985 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.547 in. 2.322 in. 0.261 in. ID (A) 1.750 in. 0.618 in. 2.437 in. 0.274 in.
CWP 10000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

3" 1502 TLH PIECE #2 & #7 3" 1502 TLH PIECE #11
3" 1502 INTEGRAL LONG RADUIS ELBOW
OD 4.325 in. B* Max. ID B (MIN) OD 4.850 in. B* Max. ID B (MIN)
ID (A) 2.625 in. 0.600 in. 3.531 in. 0.397 in. ID (A) 2.750 in. 1.050 in. 3.960 in. 0.445 in.
CWP 10000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED
3" 1502 TLH PIECE #8 3" 1502 TLH PIECE #9
OD 4.105 in. B* Max. ID B (MIN) OD 4.375 in. B* Max. ID B (MIN)
ID (A) 2.750 in. 0.678 in. 3.352 in. 0.377 in. ID (A) 2.750 in. 0.813 in. 3.572 in. 0.401 in.
CWP 10000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 8 of 20

MINIMUM WALL FOR SWIVEL JOINTS

MATERIAL FOR 4" PARTS: AISI 8620 AND 4715


SOUR SERVICE H2S
4" 1002 TLH PIECE #2, #7, & #9 4"1002 TLH PIECE #11
4" 1002 INTEGRAL LONG RADIUS ELBOW
OD 5.450 in. B* Max. ID B (MIN) OD 5.350 in. B* Max. ID B (MIN)
ID (A) 3.750 in. 0.850 in. 4.686 in. 0.382 in. ID (A) 3.750 in. 0.800 in. 4.600 in. 0.375 in.
CWP 7500 psi. *AS MANUFACTURED CWP 7500 psi. *AS MANUFACTURED

4" 1002 TLH PIECE #8 & #10


OD 5.000 in. B* Max. ID B (MIN)
ID (A) 3.750 in. 0.625 in. 4.299 in. 0.351 in.
CWP 7500 psi. *AS MANUFACTURED

4" 1502 TLH PIECE #2, #7, & #9 4" 1502 TLH PIECE #8, #10, & #11
4" 1502 INTEGRAL LONG RADUIS ELBOW
OD 5.450 in. B* Max. ID B (MIN) OD 5.350 in. B* Max. ID B (MIN)
ID (A) 3.500 in. 0.975 in. 4.450 in. 0.500 in. ID (A) 3.500 in. 0.925 in. 4.368 in. 0.491 in.
CWP 10000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 9 of 20

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 10 of 20

MINIMUM WALL FOR ITR AND ITH PUPS FOR HOSE LOOPS
MATERIAL FOR ALL PARTS: AISI 8620

2" 1502 ITR PUPS STANDARD SERVICE 2" 1502 ITH PUPS H2S SERVICE
OD 2.687 in. B* Max. ID B (MIN) OD 2.687 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.469 in. 2.049 in. 0.319 in. ID (A) 1.750 in. 0.469 in. 2.194 in. 0.247 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

2" 1002 ITR HOSE LOOP STANDARD SERVICE 2" 602 ITR HOSE LOOP STANDARD SERVICE
OD 2.687 in. B* Max. ID B (MIN) OD 2.687 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.469 in. 2.248 in. 0.219 in. ID (A) 1.750 in. 0.469 in. 2.416 in. 0.135 in.
CWP 10000 psi. *AS MANUFACTURED CWP 6000 psi. *AS MANUFACTURED

3" 1502 ITR PUPS STANDARD SERVICE 3" 1502 ITH PUPS H2S SERVICE
OD 3.750 in. B* Max. ID B (MIN) OD 3.750 in. B* Max. ID B (MIN)
ID (A) 2.750 in. 0.500 in. 2.859 in. 0.445 in. ID (A) 2.750 in. 0.500 in. 3.062 in. 0.344 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 11 of 20

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 12 of 20

MINIMUM WALL FOR INTEGRAL/NPST/LPT PUPS

MATERIAL FOR ALL PARTS: AISI 4130/4140

2" INTEGRAL FIG 1502 MALE x FEMALE PUP JOINT 2" INTEGRAL FIG 1502 MALE x FEMALE PUP JOINT
STANDARD SERVICE H2S SERVICE
OD 2.500 in. B* Max. ID B (MIN) OD 2.500 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.375 in. 2.011 in. 0.245 in. ID (A) 1.750 in. 0.375 in. 2.041 in. 0.229 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED
2" INTEGRAL FIG 1002 MALE x FEMALE PUP JOINT 2" INTEGRAL FIG 1002 MALE x FEMALE PUP JOINT
STANDARD SERVICE H2S SERVICE
OD 2.500 in. B* Max. ID B (MIN) OD 2.500 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.375 in. 2.165 in. 0.167 in. ID (A) 1.750 in. 0.375 in. 2.149 in. 0.175 in.
CWP 10000 psi. CWP 7500 psi.
2" INTEGRAL FIG 602 MALE x FEMALE PUP JOINT 2" INTEGRAL FIG 602 MALE x FEMALE PUP JOINT
STANDARD SERVICE H2S SERVICE
OD 2.500 in. B* Max. ID B (MIN) OD 2.500 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.375 in. 2.294 in. 0.103 in. ID (A) 1.750 in. 0.375 in. 2.216 in. 0.142 in.
CWP 6000 psi. *AS MANUFACTURED CWP 6000 psi. *AS MANUFACTURED
3" INTEGRAL FIG 1502 MALE x FEMALE PUP JOINT 3" INTEGRAL FIG 1502 MALE x FEMALE PUP JOINT
STANDARD SERVICE H2S SERVICE
OD 3.750 in. B* Max. ID B (MIN) OD 3.750 in. B* Max. ID B (MIN)
ID (A) 2.750 in. 0.500 in. 3.016 in. 0.367 in. ID (A) 2.750 in. 0.500 in. 3.062 in. 0.344 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 13 of 20

MINIMUM WALL FOR INTEGRAL/NPST/LPT PUPS

MATERIAL FOR ALL PARTS: AISI 4130/4140

3" INTEGRAL FIG 1002 MALE x FEMALE PUP JOINT 3" INTEGRAL FIG 1002 MALE x FEMALE PUP JOINT
STANDARD SERVICE H2S SERVICE
OD 3.750 in. B* Max. ID B (MIN) OD 3.750 in. B* Max. ID B (MIN)
ID (A) 2.750 in. 0.500 in. 3.248 in. 0.251 in. ID (A) 2.750 in. 0.500 in. 3.224 in. 0.263 in.
CWP 10000 psi. *AS MANUFACTURED CWP 7500 psi. *AS MANUFACTURED
3" INTEGRAL FIG 602 MALE x FEMALE PUP JOINT 3" INTEGRAL FIG 602 MALE x FEMALE PUP JOINT
STANDARD SERVICE H2S SERVICE
OD 3.750 in. B* Max. ID B (MIN) OD 3.750 in. B* Max. ID B (MIN)
ID (A) 2.750 in. 0.500 in. 3.441 in. 0.154 in. ID (A) 2.750 in. 0.500 in. 3.324 in. 0.213 in.
CWP 6000 psi. *AS MANUFACTURED CWP 6000 psi. *AS MANUFACTURED
1" FIG 1502 MALE x FEMALE NPST PUP JOINT 1" FIG 1502 MALE x FEMALE NPST PUP JOINT
STANDARD SERVICE H2S SERVICE
OD 1.323 in. B* Max. ID B (MIN) OD 1.323 in. B* Max. ID B (MIN)
ID (A) 0.815 in. 0.254 in. 1.064 in. 0.129 in. ID (A) 0.815 in. 0.254 in. 1.080 in. 0.121 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED
2" FIG 1502 MALE x FEMALE NPST PUP JOINT 2" FIG 1502 MALE x FEMALE NPST PUP JOINT
STANDARD SERVICE H2S SERVICE
OD 2.375 in. B* Max. ID B (MIN) OD 2.375 in. B* Max. ID B (MIN)
ID (A) 1.625 in. 0.375 in. 1.910 in. 0.232 in. ID (A) 1.625 in. 0.375 in. 1.939 in. 0.218 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 14 of 20

MINIMUM WALL FOR INTEGRAL/NPST/LPT PUPS

MATERIAL FOR ALL PARTS: AISI 4130/4140

3" FIG 1502 MALE x FEMALE NPST PUP JOINT 3" FIG 1502 MALE x FEMALE NPST PUP JOINT
STANDARD SERVICE H2S SERVICE
OD 3.500 in. B* Max. ID B (MIN) OD 3.500 in. B* Max. ID B (MIN)
ID (A) 2.420 in. 0.540 in. 2.815 in. 0.342 in. ID (A) 2.420 in. 0.540 in. 2.858 in. 0.321 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED
3" FIG 602 MALE x FEMALE NPST PUP JOINT 3" FIG 602 MALE x FEMALE NPST PUP JOINT
STANDARD SERVICE H2S SERVICE
OD 3.500 in. B* Max. ID B (MIN) OD 3.500 in. B* Max. ID B (MIN)
ID (A) 2.750 in. 0.375 in. 3.212 in. 0.144 in. ID (A) 2.750 in. 0.375 in. 3.102 in. 0.199 in.
CWP 6000 psi. *AS MANUFACTURED CWP 6000 psi. *AS MANUFACTURED
4" FIG 1502 MALE x FEMALE NPST PUP JOINT 4" FIG 1002 MALE x FEMALE NPST PUP JOINT
STANDARD SERVICE STANDARD SERVICE
OD 4.500 in. B* Max. ID B (MIN) OD 4.500 in. B* Max. ID B (MIN)
ID (A) 3.250 in. 0.625 in. 3.620 in. 0.440 in. ID (A) 3.592 in. 0.454 in. 3.897 in. 0.301 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED
2" FIG 1502 MALE x FEMALE LPT PUP JOINT 3" FIG 1502 MALE x FEMALE LPT PUP JOINT
STANDARD SERVICE STANDARD SERVICE
OD 2.375 in. B* Max. ID B (MIN) OD 3.500 in. B* Max. ID B (MIN)
ID (A) 1.500 in. 0.438 in. 1.910 in. 0.232 in. ID (A) 2.300 in. 0.600 in. 2.815 in. 0.342 in.
CWP 6000 psi. *AS MANUFACTURED CWP 6000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 15 of 20

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 16 of 20

MINIMUM WALL FOR PLUG VALVES

MATERIAL FOR ALL PARTS: AISI 4130/4140

1" PLUG VALVE W/ 2" FIG 1502 MALE x FEMALE 1" PLUG VALVE W/ 2" FIG 1502 MALE x FEMALE
STANDARD SERVICE H2S SERVICE
OD 2.660 in. B* Max. ID B (MIN) OD 2.660 in. B* Max. ID B (MIN)
ID (A) 1.000 in. 0.830 in. 2.140 in. 0.260 in. ID (A) 1.000 in. 0.830 in. 2.172 in. 0.244 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

1" PLUG VALVE W/ 1.5" FEMALE LP 1" PLUG VALVE W/ 2" MALE LP W/ 1" FEMALE LP
STANDARD SERVICE STANDARD SERVICE
OD 3.000 in. B* Max. ID B (MIN) OD 2.375 in. B* Max. ID B (MIN)
ID (A) 1.700 in. 0.650 in. 2.449 in. 0.275 in. ID (A) 1.000 in. 0.688 in. 1.939 in. 0.218 in.
CWP 10000 psi. *AS MANUFACTURED CWP 10000 psi.

2"PLUG VALVE W/ 2" FIG 1502 MALE x FEMALE 2"PLUG VALVE W/ 2" FIG 1502 MALE x FEMALE
STANDARD SERVICE H2S SERVICE
OD 2.844 in. B* Max. ID B (MIN) OD 2.844 in. B* Max. ID B (MIN)
ID (A) 1.880 in. 0.482 in. 2.288 in. 0.278 in. ID (A) 1.880 in. 0.482 in. 2.322 in. 0.261 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED
2" PLUG VALVE W/ 15K FLANGE 2" PLUG VALVE W/ 10K FLANGE
STANDARD SERVICE STANDARD SERVICE
OD 4.380 in. B* Max. ID B (MIN) OD 3.940 in. B* Max. ID B (MIN)
ID (A) 2.060 in. 1.160 in. 3.523 in. 0.428 in. ID (A) 2.060 in. 0.940 in. 3.217 in. 0.362 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

3" PLUG VALVE W/ 3" FIG 1502 MALE x FEMALE 3" PLUG VALVE W/ 3" FIG 1502 MALE x FEMALE
STANDARD SERVICE SOUR SERVICE
OD 4.030 in. B* Max. ID B (MIN) OD 4.030 in. B* Max. ID B (MIN)
ID (A) 2.620 in. 0.705 in. 3.242 in. 0.394 in. ID (A) 2.620 in. 0.705 in. 3.290 in. 0.370 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 17 of 20

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 18 of 20

MINIMUM WALL FOR INTEGRAL ELBOWS, CROSSES, TEES, AND CROSSOVERS

MATERIAL FOR ALL PARTS: AISI 4130/4140

2" 1502 SR ELBOW, CROSS, TEE 2" 1502 SR ELBOW, CROSS, TEE
STANDARD SERVICE H2S SERVICE
OD 2.840 in. B* Max. ID B (MIN) OD 2.840 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.545 in. 2.284 in. 0.278 in. ID (A) 1.750 in. 0.545 in. 2.319 in. 0.261 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

3" 1502 SR ELBOW, CROSS, TEE 3" 1502 SR ELBOW, CROSS, TEE
STANDARD SERVICE H2S SERVICE
OD 4.105 in. B* Max. ID B (MIN) OD 4.105 in. B* Max. ID B (MIN)
ID (A) 2.630 in. 0.738 in. 3.302 in. 0.401 in. ID (A) 2.630 in. 0.738 in. 3.352 in. 0.377 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED
2" 1502 MALE x FEMALE, MALE x MALE CROSSOVER 2" 1502 MALE x FEMALE, MALE x MALE CROSSOVER
STANDARD SERVICE H2S SERVICE
OD 2.805 in. B* Max. ID B (MIN) OD 2.805 in. B* Max. ID B (MIN)
ID (A) 1.630 in. 0.588 in. 2.256 in. 0.274 in. ID (A) 1.630 in. 0.588 in. 2.290 in. 0.257 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

2" 1502 FEMALE x FEMALE CROSSOVER 2" 1502 FEMALE x FEMALE CROSSOVER
STANDARD SERVICE H2S SERVICE
OD 3.250 in. B* Max. ID B (MIN) OD 3.250 in. B* Max. ID B (MIN)
ID (A) 1.630 in. 0.810 in. 2.614 in. 0.318 in. ID (A) 1.630 in. 0.810 in. 2.654 in. 0.298 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 19 of 20

MINIMUM WALL FOR INTEGRAL ELBOWS, CROSSES, TEES, AND CROSSOVERS

MATERIAL FOR ALL PARTS: AISI 4130/4140

2" 1002 MALE x FEMALE, MALE x MALE CROSSOVER 2" 1002 MALE x FEMALE, MALE x MALE CROSSOVER
STANDARD SERVICE H2S SERVICE
OD 2.625 in. B* Max. ID B (MIN) OD 2.625 in. B* Max. ID B (MIN)
ID (A) 1.750 in. 0.438 in. 2.273 in. 0.176 in. ID (A) 1.750 in. 0.438 in. 2.257 in. 0.184 in.
CWP 10000 psi. *AS MANUFACTURED CWP 7500 psi. *AS MANUFACTURED

3" 1502 MALE x FEMALE, MALE x MALE CROSSOVER 3" 1502 MALE x FEMALE, MALE x MALE CROSSOVER
STANDARD SERVICE H2S SERVICE
OD 4.105 in. B* Max. ID B (MIN) OD 4.105 in. B* Max. ID B (MIN)
ID (A) 2.300 in. 0.903 in. 3.302 in. 0.401 in. ID (A) 2.300 in. 0.903 in. 3.352 in. 0.377 in.
CWP 15000 psi. CWP 10000 psi.
3" 1502 FEMALE x FEMALE CROSSOVER 3" 1502 FEMALE x FEMALE CROSSOVER
STANDARD SERVICE H2S SERVICE
OD 4.375 in. B* Max. ID B (MIN) OD 4.375 in. B* Max. ID B (MIN)
ID (A) 2.300 in. 1.038 in. 3.519 in. 0.428 in. ID (A) 2.300 in. 1.038 in. 3.572 in. 0.401 in.
CWP 15000 psi. *AS MANUFACTURED CWP 10000 psi. *AS MANUFACTURED

3" 1002 MALE x FEMALE 3" 602 MALE x FEMALE


STANDARD SERVICE H2S SERVICE
OD 4.105 in. B* Max. ID B (MIN) OD 4.105 in. B* Max. ID B (MIN)
ID (A) 2.300 in. 0.903 in. 3.555 in. 0.275 in. ID (A) 2.300 in. 0.903 in. 3.639 in. 0.233 in.
CWP 10000 psi. *AS MANUFACTURED CWP 6000 psi. *AS MANUFACTURED

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.
DOCUMENT
BFR003
MINIMAL WALL
STANDARD FOR REVISION H

BEST PRODUCTS DATE 07/28/2016

PAGE Page 20 of 20

Wall thickness measurements should be taken at the points designated in the diagram(s), anywhere in between the points, and any other areas indicated during visual
inspection. Check the measurements around the circumference of the test point shown on the diagram on straight joints, crossovers, and male connectors. A minimum of 3
readings is advised for all parts.