Está en la página 1de 8

Traction batteries

Hawker perfect plus™


Superior efficiency and reliability - Increased capacities

Hawker perfect plus™ motive power batteries provide a high level of power and reliability for all industrial truck
applications, from simple applications with a low capacity loading up to heavy duty multi-shift applications.
Why Hawker perfect plus ?
Hawker perfect plus cells provide a higher efficiency in discharge to most other brands, achieved by advanced
components used in the construction of the positive plates. The sizing of the positive and negative plates has
been optimised according to the volume available in the cell box. The process of filling the positive plates has
been improved. All these technical enhancements have enabled an increase in the cell capacities while keeping
the same exterior dimensions. The Hawker perfect plus DIN & BS range is at the highest technology level of
European standards DIN/EN 60254 and IEC 254-2.

Cell Construction
All Hawker perfect plus cells
use robust tubular plate vented
technology, ideally suited for high
cyclic use under todays demanding
shift applications.
The tubular positive electrodes are
diecast using the highest technology
equipment available and together
with the advanced components and
materials used in their manufacture,
provide increased efficiency and
longer life than most competitors
product in the market.
The cell box and lid are made from
high impact, temperature resistant
polypropylene and heat-seal welded
to prevent electrolyte leakage.

Terminals & Connectors Flip Top Filler Caps


The specially designed bolt-on take As standard, all batteries are fitted
off terminals of the cell are mounted with our unique flip top manual
through a secure rubber seal. filling cap. These caps incorporate
The cells are joined by fully insulated electrolyte level markings, a safe
flexible and halogen free perfect plus anti-surge baffle for the electrolyte
connectors. during operation and allow adequate
This combination ensures that The cell lid is equipped with holes escape of charging gas during
no electrolyte can leak from the for the installation of the electrolyte recharge.
cells causing corrosion around the circulation system, temperature
top of the battery. It also means sensors and water probes.
a significant reduction to the
exposure of any lead outside the
cell and securely insulates against
any possible arcing points which
enhance operator safety.
The bolt-on connectors also allow
cells to be replaced or moved without
excessive work using the most
simple tools and eliminating the
dangers of dangerous flame and hot
work.
Full Range - Many Options

Hawker perfect plus™ batteries are available in sizes to fit ALL international and local brands of material
handling equipment. The cells are assembled into computer aided design steel trays under strict quality
procedures. This design process ensures the batteries are of the correct size, weight and appearance.

Hawker perfect plus™ batteries have the following options available. These options offer increased
productivity, enhanced safety and detailed monitoring and protection of your valuable asset.

®
Hawker Aquamatic™ Airlift electrolyte circulation Hawker WiIQ

The Aquamatic™ water refill system The Hawker WiIQ® has been
makes it possible to top up all the developed by EnerSys to allow full
individual cells of a battery from one monitoring of your battery operation.
central point using an integrated This small device will record battery
cap and tubing system. This system Stratification of the With Electrolyte voltage, Ah in and out, temperature,
saves you valuable time and electrolyte at different Circulation voltage balance, depth of discharge,
specific gravity levels
money maintaining your fleet. The number of cycles, low water events,
Aquamatic caps automatically ensure The Hawker electrolyte circulation discharge time, idle time and recharge
the optimum filling level, stopping system, using the Airlift principle, time.
the flow of water when the level consists of a pipe system fitted inside The memory allows over 2,500 cycles
is correct, avoiding any damaging each cell. A small air pump option of data which can be downloaded
overfill. Inspection points in the in the Hawker HF charger sends a wirelessly from a PC or laptop using
cap also allow measurement of the low rate airflow into the cell during the WiIQ Reporting Suite software for
electrolyte specific gravity. recharge which creates a circulating comprehensive report generation.
The Aquamatic filling system can be air stream inside the cell box. This This data is valuable to ensure your
expertly fitted at the factory or on site system can prevent electrolyte asset is being utilised and maintained
to existing batteries if required. stratification whilst optimising the correctly for maximum life.
charging process.

• High Level of Power and Reliability - from Light to Heavy Duty multi-shift applications
• Advanced construction using the highest quality components
• High Cycle life - Full 1500 cycles*
• Comprehensive range to suit all makes and models
• Controlled global design and assembly processes ensure EnerSys quality every time
• EnerSys global presence for prompt sales, service and support
• Productivity and Management options available for every application and every budget
PzS-cells Hawker perfect plus™ , with bolt-on connectors, dimensions according to DIN/EN 60254-2 and IEC 254-2 Series L standards

DIN Cell
Type
Nominal
Capacity
Plate
Ah
Nominal Max Cell Dimensions
mm
Weight in Kg
with electrolyte
Ah C5 L W H* +/- 5%

2PzS 120 120 60 47 198 370 8.5


3PzS 180 180 60 65 198 370 12.0
4PzS 240 240 60 83 198 370 15.4
5PzS 300 300 60 101 198 370 19.0
6PzS 360 360 60 119 198 370 22.5
7PzS 420 420 60 137 198 370 26.0
8PzS 480 480 60 155 198 370 29.5
9PzS 540 540 60 174 198 370 33.0
10PzS 600 600 60 192 198 370 36.5

2PzS 160 160 80 47 198 435 10.0


3PzS 240 240 80 65 198 435 14.2
4PzS 320 320 80 83 198 435 18.4
5PzS 400 400 80 101 198 435 22.6
6PzS 480 480 80 119 198 435 26.7
7PzS 560 560 80 137 198 435 31.3
8PzS 640 640 80 155 198 435 35.1
9PzS 720 720 80 174 198 435 39.3
10PzS 800 800 80 192 198 435 43.4

2PzS 180 180 90 47 198 505 11.9


3PzS 270 270 90 65 198 505 17.0
4PzS 360 360 90 83 198 505 22.1
5PzS 450 450 90 101 198 505 27.1
6PzS 540 540 90 119 198 505 32.2
7PzS 630 630 90 137 198 505 37.2
8PzS 720 720 90 155 198 505 42.3
9PzS 810 810 90 174 198 505 47.4
10PzS 900 900 90 192 198 505 52.4

2PzS 210 210 105 47 198 541 13.5


3PzS 315 315 105 65 198 541 19.1
4PzS 420 420 105 83 198 541 24.6
5PzS 525 525 105 101 198 541 30.5
6PzS 630 630 105 119 198 541 36.1
7PzS 735 735 105 137 198 541 41.8
8PzS 840 840 105 155 198 541 47.4
9PzS 945 945 105 174 198 541 53.1
10PzS 1050 1050 105 192 198 541 58.4

2PzS 220 220 110 47 198 556 13.0


3PzS 330 330 110 65 198 556 18.5
4PzS 440 440 110 83 198 556 24.0
5PzS 550 550 110 101 198 556 29.7
6PzS 660 660 110 119 198 556 35.2
7PzS 770 770 110 137 198 556 40.7
8PzS 880 880 110 155 198 556 46.4
9PzS 990 990 110 174 198 556 51.8
10PzS 1100 1100 110 192 198 556 57.4
* Overlid jar height (h) is maximum cell height (H) minus 30mm. Terminals are F- M10 at 25Nm+/- 2
PzS-cells Hawker perfect plus™ , with bolt-on connectors, dimensions according to DIN/EN 60254-2 and IEC 254-2 Series L standards

DIN Cell
Type
Nominal
Capacity
Plate
Ah
Nominal Max Cell Dimensions
mm
Weight in Kg
with electrolyte
Ah C5 L W H* +/- 5%

2PzS 230 230 115 47 198 575 14.2


3PzS 345 345 115 65 198 575 20.3
4PzS 460 460 115 83 198 575 26.4
5PzS 575 575 115 101 198 575 32.4
6PzS 690 690 115 119 198 575 39.0
7PzS 805 805 115 137 198 575 44.7
8PzS 920 920 115 155 198 575 50.6
9PzS 1035 1035 115 174 198 575 56.6
10PzS 1150 1150 115 192 198 575 62.7

2PzS 250 250 125 47 198 600 15.0


3PzS 375 375 125 65 198 600 21.2
4PzS 500 500 125 83 198 600 27.4
5PzS 625 625 125 101 198 600 33.9
6PzS 750 750 125 119 198 600 40.3
7PzS 875 875 125 137 198 600 46.5
8PzS 1000 1000 125 155 198 600 53.1
9PzS 1125 1125 125 174 198 600 59.4
10PzS 1250 1250 125 192 198 600 66.0

2PzS 280 280 140 47 198 715 17.5


3PzS 420 420 140 65 198 715 24.7
4PzS 560 560 140 83 198 715 31.8
5PzS 700 700 140 101 198 715 39.3
6PzS 840 840 140 119 198 715 46.7
7PzS 980 980 140 137 198 715 53.9
8PzS 1120 1120 140 155 198 715 61.3
9PzS 1260 1260 140 174 198 715 68.6
10PzS 1400 1400 140 192 198 715 76.0

2PzS 310 310 155 47 198 750 18.9


3PzS 465 465 155 65 198 750 26.7
4PzS 620 620 155 83 198 750 34.6
5PzS 775 775 155 101 198 750 42.6
6PzS 930 930 155 119 198 750 50.5
7PzS 1085 1085 155 137 198 750 58.5
8PzS 1240 1240 155 155 198 750 66.4
9PzS 1395 1395 155 174 198 750 74.4
10PzS 1550 1550 155 192 198 750 82.4
* Overlid jar height (h) is maximum cell height (H) minus 30mm. Terminals are F- M10 at 25Nm+/- 2
PzB-cells Hawker perfect plus™ , with bolt-on connectors, dimensions according to IEC 254-2 Series E standard

BS Cell
Type
Nominal
Capacity
Plate
Ah
Nominal Max Cell Dimensions
mm
Weight in Kg
with electrolyte
Ah C5 L W H* +/- 5%

2PzB 46 46 23 45 158 230 4.1


3PzB 69 69 23 61 158 230 5.6
4PzB 92 92 23 77 158 230 7.0
5PzB 115 115 23 93 158 230 8.5
6PzB 138 138 23 109 158 230 10.0

2PzB 64 64 32 45 158 292 5.0


3PzB 96 96 32 61 158 292 6.8
4PzB 128 128 32 77 158 292 8.7
5PzB 160 160 32 93 158 292 10.6
6PzB 192 192 32 109 158 292 12.5
7PzB 224 224 32 125 158 292 14.4
8PzB 256 256 32 141 158 292 16.2

2PzB 84 84 42 45 158 358 6.5


3PzB 126 126 42 61 158 358 8.9
4PzB 168 168 42 77 158 358 11.4
5PzB 210 210 42 93 158 358 13.8
6PzB 252 252 42 109 158 358 16.3
7PzB 294 294 42 125 158 358 18.8
8PzB 336 336 42 141 158 358 21.2

2PzB 110 110 55 45 158 428 7.9


3PzB 165 165 55 61 158 428 11.0
4PzB 220 220 55 77 158 428 14.0
5PzB 275 275 55 93 158 428 17.1
6PzB 330 330 55 109 158 428 20.1
7PzB 385 385 55 125 158 428 23.2
8PzB 440 440 55 141 158 428 26.2
9PzB 495 495 55 157 158 428 29.2
10PzB 550 550 55 173 158 428 32.3

2PzB 130 130 65 45 158 484 9.1


3PzB 195 195 65 61 158 484 12.5
4PzB 260 260 65 77 158 484 16.1
5PzB 325 325 65 93 158 484 19.5
6PzB 390 390 65 109 158 484 23.0
7PzB 455 455 65 125 158 484 26.5
8PzB 520 520 65 141 158 484 30.1
9PzB 585 585 65 157 158 484 33.5
10PzB 650 650 65 173 158 484 37.0
11PzB 715 715 65 189 158 484 41.8
12PzB 780 780 65 205 158 484 46.2

2PzB 150 150 75 45 158 541 10.3


3PzB 225 225 75 61 158 541 14.2
4PzB 300 300 75 77 158 541 18.2
4PzB300A 300 75 70 158 519 16.6
5PzB 375 375 75 93 158 541 22.2
6PzB 450 450 75 109 158 541 26.2
7PzB 525 525 75 125 158 541 30.2
8PzB 600 600 75 141 158 541 34.2
9PzB 675 675 75 157 158 541 38.2
10PzB 750 750 75 173 158 541 42.2
11PzB 825 825 75 189 158 541 47.8
12PzB900 900 75 205 158 541 52.0
* Overlid jar height (h) is maximum cell height (H) minus 30mm. Terminals are F- M10 at 25Nm+/- 2
PzB-cells Hawker perfect plus™ , with bolt-on connectors, dimensions according to IEC 254-2 Series E standard

BS Cell
Type
Nominal
Capacity
Plate
Ah
Nominal Max Cell Dimensions
mm
Weight in Kg
with electrolyte
Ah C5 L W H* +/- 5%

2PzB 170 170 85 45 158 597 12.3


3PzB 255 255 85 61 158 597 17.0
4PzB 340 340 85 77 158 597 21.6
5PzB 425 425 85 93 158 597 26.3
6PzB 510 510 85 109 158 597 30.9
7PzB 595 595 85 125 158 597 35.6
8PzB 680 680 85 141 158 597 40.4
9PzB 765 765 85 157 158 597 44.8
10PzB 850 850 85 173 158 597 49.7
11PzB935 935 85 189 158 597 54.4
12PzB 1020 1020 85 205 158 597 58.2

2PzB200 200 100 45 158 633 12.9


3PzB300 300 100 61 158 633 17.7
4PzB400 400 100 77 158 633 22.6
5PzB500 500 100 93 158 633 27.5
6PzB600 600 100 109 158 633 32.4
7PzB700 700 100 125 158 633 37.3
8PzB800 800 100 141 158 633 42.2
9PzB900 900 100 157 158 633 46.8
10PzB1000 1000 100 173 158 633 52.2
11PzB 1100 1100 100 189 158 633 56.0
12PzB 1200 1200 100 205 158 633 61.2

2PzB 210 210 105 45 158 713 14.8


3PzB 315 315 105 61 158 713 20.4
4PzB 420 420 105 77 158 713 26.1
5PzB 525 525 105 93 158 713 31.7
6PzB 630 630 105 109 158 713 37.3
7PzB 735 735 105 125 158 713 43.0
8PzB 840 840 105 141 158 713 48.7
9PzB 945 945 105 157 158 713 50.3
10PzB1050 1050 105 173 158 713 56.0
11PzB1155 1155 105 189 158 713 61.0
12PzB 1260 1260 105 205 158 713 66.5
* Overlid jar height (h) is maximum cell height (H) minus 30mm. Terminals are F- M10 at 25Nm+/- 2
Wherever you do business, EnerSys® can EnerSys has an enviable position in EnerSys integrated sales and service
support you with motive power energy. technology leadership and with significant network is dedicated to providing our
The Hawker® branded range of matched investment in research and development customers with the best solutions and
batteries, chargers and systems provide we intend to stay at the leading edge after sales support for their business.
trouble free performance under the in product innovation. The recently Whether you require one battery or a
most demanding service conditions. developed energy solutions of Hawker complete fleet of batteries, chargers,
Our strategically located manufacturing Waterless® and Hawker XFC™ batteries battery handling systems and state of the
plants around the globe are efficient and along with Lifetech®, LifeIQ™ and art fleet management systems, you can
responsive with a culture of continuous Lifespeed IQ™ HF chargers, have defined count on us.
improvement and added value to our new benefits for our customers with faster EnerSys is the world’s largest industrial
business partners. recharge, more machine availability, lower battery manufacturer and we are
operating and investment costs and dedicated to being the best.
reduced carbon footprint.
Our team of development engineers
is driven by the desire to build the best
energy solutions and work closely with
customers and suppliers to identify future
development ideas. Our bias for rapid
innovation means we get new products to
market fast.

China Australia / New Zealand


Room 902, Sheng Gao Int. Building 46 Egerton Street
No. 137 Xian Xia Road Silverwater, NSW, 2128
Shanghai, PRC, 200131 Australia
+86 21 6273 6300 +61 2 9739 9999
motivepower@enersys.com.cn sales@enersys.com.au
MPAPP 02.2015 Subject to revisions without prior notice. E&OE

Asia Regional Headquarters Singapore India


#11-03 No. 85 Tuas Ave 1 Plot No. 1057M, 1st Floor
Gateway East Building Singapore, 639518 Road #45, Jubilee Hills
152 Beach Road +65 6558 7333 Hyderabad, 500033
Singapore, 189721 sales@enersys.com.sg +91 40 670 46701
marketing@enersys.com.sg sales@enersys.co.in
www.enersys-asia.com
Malaysia Japan
No. 10 Jalan Anggerik Mokara 31/47 5F Mitaka Mitsubishi Building
Kota Kemuning, Seksyen 31 Shimorenjyaku 3-26-12
40460 Shah Alam Mitaka, 181 0013
Selangor Darul Ehsan, Malaysia Tokyo
+60 3 5125 1111 +81 0422 70 3831
sales@enersys.com.my info@enersys-japan.com

© 2014 EnerSys. All rights reserved.


All trademarks and logos are the property of, or licensed to EnerSys and its affiliates
* Cycle life at 80% DOD, 30°C, dependent on correct maintenance and utilisation according to relevant product instructions of use. Results can vary.

También podría gustarte