CELDA DE MEDIA TENSIÓN 10KV - NV.4370 NPS

CELDA ENTRADA CELDA TRANSFORMADOR 150KVA CELDA TRANSFORMADOR 3000KVA


+J01 +J02 +J03

HORA KV A P.F KVA KW KVAR KWh KVAh KVARh KV A P.F KVA KW KVAR KWh KVAh KVARh KV A P.F KVA KW KVAR KWh KVAh KVARh

0:00

1:00

2:00

3:00

4:00

5:00

6:00

7:00

8:00

9:00

10:00

11:00

12:00

13:00

14:00

15:00

16:00

17:00

18:00

19:00

20:00

21:00

22:00

23:00

TEMPERATURA DE TRANSFORMADOR 3000KVA °C


VARIACIÓN DE LA POTENCIA (KW) (01 al 31-03-2018)
1600
DIA PRINCIPAL +J01 150KVA +J02 3000KVA +J03
MAX 10 KV MIN 10 KV MAX 10 KV MIN 10 KV MAX 10 KV MIN 10 KV
MES
1-Mar 1400
2-Mar
3-Mar
1200
4-Mar
5-Mar
6-Mar 1000
7-Mar
8-Mar
800
9-Mar

kw
10-Mar
11-Mar 600
12-Mar
13-Mar
400
14-Mar
15-Mar
16-Mar 200
17-Mar
18-Mar 0
19-Mar ar ar
- M -M
20-Mar 1 2 3
21-Mar
22-Mar
23-Mar
24-Mar
25-Mar
26-Mar
27-Mar Medidor Celda Principal 10
28-Mar Medidor Celda 150KVA 10 K
29-Mar Medidor Celda 3000KVA 10
30-Mar
31-Mar
VARIACIÓN DE LA POTENCIA (KW) SE MAGISTRAL EXISTENTE (MARZO-2018)
1600

1400

1200

1000

800
kw

600

400

200

0
ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar ar
- M -M -M -M -M -M -M -M -M -M -M -M -M -M -M -M -M -M -M -M -M -M -M -M -M
1 2 3 4 5 6 7 8 9 10 1 1 12 13 1 4 15 16 1 7 18 19 2 0 21 22 2 3 24 25 2

RESUMEN DE LAS CELDAS DE SALIDA A MINA - (MARZO -2018)


MAXIMA DEMANDA DEL MES CONSUMO DE ENERGÍA
KW KVAR AMP KW/h
Medidor Celda Principal 10 KV +J01
Medidor Celda 150KVA 10 KV +J02
Medidor Celda 3000KVA 10 KV +J03
XISTENTE (MARZO-2018)

MAX MAG. SUR


MIN MAG. SUR
MAX MAG. CENTRO
MIN MAG. CENTRO
MAX NIVEL 4440
MIN NIVEL 4440

ar ar ar ar ar ar ar ar ar ar ar ar ar
M -M -M -M -M -M -M -M -M -M -M -M -M
2 0 21 22 2 3 24 25 2 6 27 28 2 9 3 0 31

CONSUMO DE ENERGÍA
KVAR/h
MARZO 2018
REGISTRO DE CONSUMO MEDIDORES EN 1

MEDIDOR DE LLEGADA EN 10 KV - CELDA PRINCIPAL +J01


DATOS DEL MEDIDOR ENERGÍA APARENTE KVAh
MARCA Schneider Lectura actual 3/31/2018 #REF!
MODELO ION 7650 Lectura anterior 3/1/2018 0
SERIE CONSUMO #REF!

MEDIDOR DE LLEGADA EN 10 KV - CELDA 150KVA +J02


DATOS DEL MEDIDOR ENERGÍA APARENTE KVAh
MARCA Schneider Lectura actual 3/31/2018 #REF!
MODELO ION 7650 Lectura anterior 3/1/2018 0
SERIE CONSUMO #REF!

MEDIDOR DE LLEGADA EN 10 KV - CELDA 3000KVA +J03


DATOS DEL MEDIDOR ENERGÍA APARENTE KVAh
MARCA Schneider Lectura actual 3/31/2018 #REF!
MODELO ION 7650 Lectura anterior 3/1/2018 0
SERIE CONSUMO #REF!
MARZO 2018
DE CONSUMO MEDIDORES EN 10 KV - SE NV.4370 NPS

EN 10 KV - CELDA PRINCIPAL +J01


ENERGÍA ACTIVA KWh ENERGÍA REACTIVA KVARh
#REF! #REF!
0 0
#REF! #REF!

A EN 10 KV - CELDA 150KVA +J02


ENERGÍA ACTIVA KWh ENERGÍA REACTIVA KVARh
#REF! #REF!
0 0
#REF! #REF!

EN 10 KV - CELDA 3000KVA +J03


ENERGÍA ACTIVA KWh ENERGÍA REACTIVA KVARh
#REF! #REF!
0 0
#REF! #REF!
MAXIMA DEMANDA EN 10 K
A CELDA PRINCIPAL - J01 CELDA 150KV
H
POTEN. AMP. COSØ POTEN.
C
FE

KW KVA KVAR (A) F. P. KW


1-Mar 1022 2200 607 131.00 0.96 0
2-Mar 1183 2050 556 131.00 0.96 0
3-Mar 1152 2223 619 131.00 0.96 0
4-Mar 627 2248 626 131.00 0.96 0
5-Mar 117 2278 633 131.00 0.96 0
6-Mar 1046 1877 502 131.00 0.96 0
7-Mar 175 2227 630 131.00 0.96 0
8-Mar 1027 2064 576 131.00 0.96 0
9-Mar 1228 2171 608 131.00 0.96 0
10-Mar 1050 2165 604 131.00 0.96 0
11-Mar 949 2299 733 131.00 0.96 0
12-Mar 946 2217 624 131.00 0.96 0
13-Mar 1009 2267 637 131.00 0.96 0
14-Mar 967 2217 628 131.00 0.96 0
15-Mar 876 2012 556 131.00 0.96 0
16-Mar 917 2063 570 131.00 0.96 0
17-Mar 921 2183 620 131.00 0.96 0
18-Mar 1036 2348 678 131.00 0.96 0
19-Mar 987 2249 642 131.00 0.96 0
20-Mar 1037 2254 645 131.00 0.96 0
21-Mar 1040 2242 607 131.00 0.96 0
22-Mar 1040 2238 607 131.00 0.96 0
23-Mar 1124 2190 607 131.00 0.96 0
24-Mar 0 0 607 131.00 0.96 0
25-Mar 0 0 607 131.00 0.96 0
26-Mar 0 0 607 131.00 0.96 0
27-Mar 0 0 607 131.00 0.96 0
28-Mar 0 0 607 131.00 0.96 0
29-Mar #REF! #REF! 607 131.00 0.96 0
30-Mar 0 0 607 131.00 0.96 0
31-Mar #REF! #REF! 607 131.00 0.96 0
MAX DEL MES #REF! #REF! 733 131.00 0.96 0
A DEMANDA EN 10 KV - SE NV.4370 NPS
CELDA 150KVA - J02 CELDA 3000KVA - J03
AMP. COSØ POTEN. AMP.
KVA KVAR (A) F. P. KW KVA KVAR (A)
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
0 0 0.00 0.00 0 0 0 128.00
- J03
COSØ
F. P.
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
FECHA : 2/1/2019
CELDAS DE MEDIA TENSIÓN 10KV
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00 21:00 22:00 23:00 TOTAL CONSUMO
KV 9.70 9.60 9.80 9.50 9.50 9.60 9.60 9.80 10.00 10.00 9.60 9.60 9.70 9.80 9.90 10.00 9.50 9.80 9.80 9.80 9.80 9.80 9.70 9.70 MAX. KV 10.00
CELDA ENTRADA

A 77.00 131.00 65.00 106.00 106.00 105.00 105.00 102.00 63.00 64.00 111.00 120.00 122.00 115.00 63.00 64.00 126.00 105.00 106.00 104.00 103.00 103.00 104.00 103.00 MAX. AMP. 131.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 MAX. F.P. 0.96
J01

KVA 1270 2200 1076 1760 1762 1753 1763 1744 1664 1077 1856 2007 2060 1956 1175 1840 2088 1794 1807 1765 1767 1767 1757 1760 MAX. KVA 2200 MIN. KVA 1076
KW 1215 2116 1036 1690 1693 1693 1699 1681 1022 1036 1797 1931 1981 1883 1130 1784 2007 1733 1740 1710 1713 1713 1710 1715 MAX. KW 1022
KVAR 366 607 301 458 460 460 461 461 297 302 496 537 564 528 307 259 569 471 477 462 465 465 455 460 MAX. KVAR 607
KW/H TOTAL KW/H 0
KVA/H TOTAL KVA/H 0
KVAR/H TOTAL KVAR/H 0
KV MAX. KV 0.00
CELDA TRANSF.

A MAX. AMP. 0.00


150KVA

P.F. MAX. F.P. 0.00


J02

KVA MAX. KVA 0 MIN. KVA 0


KW MAX. KW 0
KVAR MAX. KVAR 0
KW/H TOTAL KW/H 0
KVA/H TOTAL KVA/H 0
KVAR/H TOTAL KVAR/H 0
KV MAX. KV 0.00
CELDA TRANSF.

A 74.00 128.00 60.00 102.00 102.00 100.00 99.00 101.00 60.00 60.00 111.00 120.00 121.00 114.00 61.00 60.00 124.00 104.00 105.00 102.00 102.00 102.00 101.00 101.00 MAX. AMP. 128.00
3000KVA

P.F. MAX. F.P. 0.00


J03

KVA MAX. KVA 0 MIN. KVA 0


KW MAX. KW 0
KVAR MAX. KVAR 0
KW/H TOTAL KW/H 0
KVA/H TOTAL KVA/H 0
KVAR/H TOTAL KVAR/H 0
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1 °C
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2 °C
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.60 9.60 9.60 9.50 9.60 97.00 9.80 9.80 9.80 9.80
CELDA ENTRADA

A 107.00 106.00 108.00 124.00 125.00 103.00 108.00 108.00 102.00 90.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 1797 1778 1807 2045 2050 1752 1798 170 1750 1524
KW 1731 1716 1743 1969 1970 1695 1740 1786 6189 1472
KVAR 474 469 478 554 556 440 472 484 453 391
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 102.00 103.00 105.00 120.00 121.00 100.00 102.00 107.00 102.00 88.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/2/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.60 9.90 9.70 9.80 9.60 9.60 9.80 9.80 9.80 9.70 9.70 9.60
121.00 100.00 95.00 103.00 107.00 117.00 75.00 77.00 107.00 106.00 105.00 112.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.95 0.96 0.96 0.96 0.96
2026 1716 1622 1760 1956 1956 1732 1296 1820 1800 1795 1870
1953 1657 1568 1699 1183 1883 1192 1246 1758 1735 1730 1810
546 447 410 451 530 530 351 373 480 471 471 487

119.00 99.00 94.00 102.00 106.00 115.00 71.00 74.00 106.00 103.00 102.00 109.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.50 9.50 MAX. KV 97.00
111.00 112.00 MAX. AMP. 125.00
0.96 0.96 MAX. F.P. 0.96
1854 1844 MAX. KVA 2050 MIN. KVA
1784 1773 MAX. KW 1183
488 487 MAX. KVAR 556
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
107.00 106.00 MAX. AMP. 121.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
170

0
CELD
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.80 9.80 9.50 9.70 9.80 9.60 9.80 9.80 9.80 9.80
CELDA ENTRADA

A 75.00 76.00 134.00 73.00 74.00 133.00 107.00 100.00 76.00 77.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 1244 1245 2221 1200 1230 2223 1797 1721 1276 1288
KW 1192 1198 2135 1152 1178 2136 1743 1652 1224 1235
KVAR 356 358 607 335 354 619 472 448 359 369
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 70.00 71.00 131.00 68.00 69.00 129.00 102.00 99.00 72.00 74.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/3/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.90 9.60 9.80 9.70 9.70 9.70 9.90 9.90 9.80 9.70 9.70 9.90
78.00 126.00 103.00 106.00 117.00 115.00 76.00 76.00 106.00 130.00 129.00 73.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1298 2103 1768 1802 1972 1947 1276 1277 1809 2198 2185 1239
1243 2022 1704 1732 1882 1875 1223 1224 1743 2115 2101 1186
372 581 466 476 534 524 363 364 479 604 602 344

75.00 124.00 102.00 105.00 116.00 114.00 73.00 73.00 105.00 127.00 126.00 69.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.70 9.70 MAX. KV 9.90
76.00 77.00 MAX. AMP. 134.00
0.96 0.96 MAX. F.P. 0.96
1250 1261 MAX. KVA 2223 MIN. KVA 1200
1198 1208 MAX. KW 1152
355 362 MAX. KVAR 619
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
71.00 72.00 MAX. AMP. 131.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CELDA
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.50 9.80 9.90 9.80 9.50 9.90 9.80 9.80 9.90 9.90
CELDA ENTRADA

A 130.00 74.00 74.00 75.00 134.00 73.00 107.00 106.00 74.00 73.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.86 0.87
J01

KVA 2230 1226 1244 1256 2218 1234 1825 1818 1277 1299
KW 627 1176 1193 1203 2133 1184 1760 1752 1224 1246
KVAR 349 356 362 608 347 480 480 364 371
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 130.00 69.00 70.00 70.00 130.00 68.00 103.00 106.00 73.00 74.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/4/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.70 9.50 9.80 9.70 9.60 9.90 9.60 9.80 9.70 9.70 9.50 9.90
119.00 121.00 128.00 103.00 122.00 66.00 135.00 66.00 107.00 108.00 130.00 72.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
2021 2001 2161 1755 2039 1102 2247 1096 1807 1843 2248 1222
1948 1923 2080 1696 1961 1056 2158 1051 1744 1775 2161 1175
549 548 593 459 558 313 626 310 483 492 626 342

119.00 119.00 128.00 101.00 121.00 62.00 134.00 62.00 106.00 105.00 130.00 67.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.90 9.80 MAX. KV 9.90
74.00 74.00 MAX. AMP. 135.00
0.96 0.96 MAX. F.P. 0.96
1247 1248 MAX. KVA 2248 MIN. KVA 1096
1197 1199 MAX. KW 627
353 354 MAX. KVAR 626
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
69.00 69.00 MAX. AMP. 134.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.70 9.80 9.90 9.70 9.90 9.90 9.80
CELDA ENTRADA

A 130.00 129.00 73.00 71.00 73.00 128.00 108.00


P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 2278 2250 1228 1220 1237 2248 1809


KW 2187 2160 1178 1171 117 2140 1745
KVAR 633 601 347 345 350 600 483
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 131.00 129.00 69.00 70.00 69.00 127.00 106.00


3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/5/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
MAX. KV 9.90
MAX. AMP. 130.00
MAX. F.P. 0.96
MAX. KVA 2278 MIN. KVA 1220
MAX. KW 117
MAX. KVAR 633
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 131.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.70 9.70 9.60
CELDA ENTRADA

A 109.00 108.00 112.00


P.F. 0.96 0.96 0.96
J01

KVA 1837 1836 1877


KW 1770 1776 1807
KVAR 491 476 502
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 107.00 108.00 111.00


3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/6/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.60 9.70 9.80 9.70 9.90 9.80 9.80 9.80 9.80 9.70
112.00 100.00 66.00 103.00 77.00 105.00 106.00 106.00 106.00 107.00
0.96 0.96 0.96 0.96 0.96 0.96 .0.96 0.96 0.96 0.96
1870 1706 1091 1740 1285 1797 1803 1805 104 1800
1806 1645 1046 1681 1230 1735 1738 1740 1740 1735
492 449 306 458 370 408 479 476 476 475

112.00 100.00 62.00 101.00 73.00 104.00 105.00 102.00 103.00 103.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.90 9.80 MAX. KV 9.90
73.00 74.00 MAX. AMP. 112.00
0.96 96.00 MAX. F.P. 96.00
1217 1230 MAX. KVA 1877 MIN. KVA 104
1167 1169 MAX. KW 1046
346 347 MAX. KVAR 502
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
68.00 70.00 MAX. AMP. 112.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.60 9.80 9.80 9.60 9.60 9.60 9.80 9.90 9.90 9.70
CELDA ENTRADA

A 130.00 73.00 74.00 133.00 73.00 130.00 109.00 76.00 77.00 79.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 2218 1214 1215 2227 1214 2002 1872 1275 1284 1311
KW 2126 1164 1163 2134 1162 2112 1804 1222 1228 1253
KVAR 624 344 346 630 345 620 501 363 370 381
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 128.00 68.00 70.00 129.00 69.00 129.00 106.00 72.00 73.00 76.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/7/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.60 9.60 9.90 9.70 9.60 9.50 9.60 9.80 9.80 9.80 9.70 9.70
132.00 125.00 65.00 101.00 101.00 128.00 126.00 78.00 107.00 108.00 110.00 103.00
0.95 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
2197 2097 1094 1698 1702 2113 2098 1283 1815 1817 1820 1729
2108 2017 1049 1637 1644 2028 2027 1230 1750 175 1760 1671
619 584 310 444 449 597 587 370 483 484 487 453

130.00 63.00 63.00 100.00 100.00 126.00 127.00 73.00 73.00 72.00 99.00 100.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.70 9.80 MAX. KV 9.90
104.00 101.00 MAX. AMP. 133.00
0.96 0.60 MAX. F.P. 0.96
1730 1727 MAX. KVA 2227 MIN. KVA 1094
1672 1667 MAX. KW 175
454 450 MAX. KVAR 630
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
100.00 100.00 MAX. AMP. 130.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 97.00 9.70 9.80 9.80 9.90 9.80 9.70 9.70 9.60
CELDA ENTRADA

A 111.00 109.00 100.00 109.00 76.00 101.00 108.00 108.00 109.00


P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 1884 1880 1869 1870 1277 1727 1842 1834 1822
KW 1817 1810 1800 1812 1217 1667 1772 1770 1755
KVAR 506 504 499 498 367 450 490 492 488
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 129.00 122.00 106.00 109.00 71.00 100.00 107.00 106.00 107.00


3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/8/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00 21:00
9.60 9.80 9.80 9.60 9.50 9.60 9.70 9.50 9.60 9.80 9.80 9.80
104.00 104.00 104.00 106.00 118.00 115.00 64.00 124.00 105.00 105.00 104.00 105.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1744 1752 1760 1765 1953 1924 1070 2058 1762 1764 1765 1751
1684 1690 1698 1699 1880 1854 1027 1977 1700 1700 1705 1711
461 462 463 469 537 525 305 571 465 464 463 459

101.00 100.00 101.00 103.00 114.00 112.00 60.00 122.00 102.00 104.00 104.00 103.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.70 9.60 MAX. KV 97.00
123.00 124.00 MAX. AMP. 124.00
0.96 0.96 MAX. F.P. 0.96
2011 2064 MAX. KVA 2064 MIN. KVA 1070
1972 1971 MAX. KW 1027
554 576 MAX. KVAR 576
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
123.00 122.00 MAX. AMP. 129.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.80 9.60 9.50 9.90 9.80 9.70 9.80 9.70
CELDA ENTRADA

A 77.00 127.00 123.00 77.00 78.00 123.00 101.00 108.00


P.F. 0.95 0.95 0.96 0.96 0.95 0.96 0.96 0.96
J01

KVA 1283 2171 2064 1284 1361 2077 1735 1828


KW 1228 2044 1982 1230 1246 1995 1677 1762
KVAR 371 596 573 371 379 577 452 490
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 74.00 127.00 122.00 74.00 75.00 123.00 101.00 105.00 111.00


3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/9/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.80 9.70 MAX. KV 9.90
76.00 129.00 MAX. AMP. 129.00
0.95 0.95 MAX. F.P. 0.96
1300 2163 MAX. KVA 2171 MIN. KVA 1283
1244 2076 MAX. KW 1228
376 608 MAX. KVAR 608
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
75.00 129.00 MAX. AMP. 129.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.60 9.90 9.50 9.90 9.80 9.90 9.80 9.90 9..5
CELDA ENTRADA

A 126.00 77.00 130.00 75.00 77.00 76.00 126.00 78.00 121.00


P.F. 0.95 0.95 0.95 0.95 0.95 0.95 0.96 0.96 0.96
J01

KVA 2103 1289 2147 1266 1278 1286 2148 1305 2016
KW 2019 1254 2062 1212 1223 1230 2065 1248 1935
KVAR 591 373 604 365 375 375 601 382 555
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 126.00 73.00 127.00 72.00 75.00 73.00 125.00 74.00 120.00


3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/10/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.40 9.40 9.80 9.50 9.50 9.50 9.70 9.60 9.60 9.60 9.60 9.50
122.00 126.00 67.00 120.00 122.00 123.00 66.00 126.00 129.00 121.00 120.00 118.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
2002 2022 1112 1994 2012 2039 1095 2113 2165 2014 1997 1947
1924 1944 1066 1917 1931 1960 1050 2028 2078 1937 1921 1874
552 560 320 549 559 566 312 590 603 554 548 532

119.00 124.00 117.00 117.00 120.00 120.00 62.00 122.00 127.00 122.00 120.00 117.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.70 9.70 MAX. KV 9.90
79.00 79.00 MAX. AMP. 130.00
0.96 0.96 MAX. F.P. 0.96
1296 1296 MAX. KVA 2165 MIN. KVA 1095
1239 1240 MAX. KW 1050
380 378 MAX. KVAR 604
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
77.00 75.00 MAX. AMP. 127.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.60 9.70 9.90 9.50 9.60 9.80 9.70 9.50 9.50
CELDA ENTRADA

A 128.00 122.00 72.00 130.00 124.00 77.00 108.00 109.00 123.00


P.F. 0.95 0.96 0.95 0.95 0.96 0.96 0.96 0.96 0.96
J01

KVA 2132 2065 1285 2143 2073 1285 1832 1816 2028
KW 2046 1983 1228 2055 1989 1229 1763 1745 1949
KVAR 600 373 374 609 579 374 488 483 561
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 126.00 120.00 74.00 129.00 124.00 74.00 107.00 106.00 120.00


3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/11/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00 21:00
9.40 9.80 9.80 9.70 9.80 9.60 9.80 9.80 10.00 9.90 9.80
121.00 77.00 77.00 79.00 79.00 138.00 80.00 80.00 80.00 59.00 62.00
0.96 0.96 0.96 0.96 0.95 0.95 0.95 0.95 0.95 0.96 0.96
1986 1276 1282 1302 1312 2299 1324 1322 1356 989 1024
1908 1221 1228 1248 1254 2203 1271 1270 1297 949 985
598 367 369 733 382 652 388 387 396 271 285

118.00 72.00 72.00 73.00 134.00 76.00 77.00 76.00 76.00 56.00 59.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.60 9.60 MAX. KV 10.00
109.00 109.00 MAX. AMP. 138.00
0.96 0.96 MAX. F.P. 0.96
1832 1829 MAX. KVA 2299 MIN. KVA 989
1766 1761 MAX. KW 949
487 488 MAX. KVAR 733
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
108.00 108.00 MAX. AMP. 134.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.70 9.60 9.60 9.60 9.70 9.60 9.60 9.70 9.70 9.70
CELDA ENTRADA

A 108.00 113.00 113.00 112.00 112.00 113.00 112.00 116.00 116.00 118.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 1823 1879 1883 1885 1889 1885 1886 1966 1966 2023
KW 1757 1808 1813 1815 1818 1815 1817 1890 1890 946
KVAR 487 507 509 508 509 510 511 535 535 555
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 107.00 111.00 113.00 112.00 111.00 111.00 112.00 112.00 113.00 115.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/12/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
10.20 9.70 9.70 9.60 9.50 9.90 9.90 9.70 9.70 9.80 9.80 9.70
61.00 131.00 131.00 129.00 130.00 61.00 63.00 131.00 130.00 99.00 100.00 106.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1055 2180 2180 2160 2154 1019 1049 2217 2202 1682 1708 1795
1014 2093 2093 2073 2067 989 1005 2127 2116 1622 1650 1732
297 612 612 600 603 281 296 624 619 438 445 474

57.00 126.00 126.00 126.00 126.00 57.00 59.00 128.00 127.00 97.00 99.00 105.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.70 9.60 MAX. KV 10.20
113.00 113.00 MAX. AMP. 131.00
0.96 0.96 MAX. F.P. 0.96
1897 1890 MAX. KVA 2217 MIN. KVA 1019
1826 1817 MAX. KW 946
513 510 MAX. KVAR 624
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
111.00 112.00 MAX. AMP. 128.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.60 9.70 9.70 9.50 9.60 9.50 9.60 9.50 9.60 9.90
CELDA ENTRADA

A 112.00 110.00 112.00 100.00 101.00 102.00 102.00 101.00 102.00 63.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 1873 1866 1869 1670 1690 1709 1709 1710 1715 1060
KW 1802 1798 1799 1613 1632 1648 1648 1646 1650 1016
KVAR 504 500 503 436 442 448 448 447 446 299
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 111.00 109.00 110.00 98.00 101.00 100.00 101.00 98.00 100.00 58.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/13/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.90 9.60 9.60 9.90 9.60 9.90 9.90 9.80 9.80 9.80 9.80 9.70
64.00 135.00 131.00 64.00 133.00 63.00 63.00 132.00 102.00 109.00 108.00 101.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1075 2240 2198 1073 2217 1051 1057 2267 1744 1852 1854 1709
1030 2149 2108 1030 2127 1009 1014 2176 1679 1785 1786 1649
310 634 617 310 626 295 296 637 457 493 493 447

59.00 131.00 127.00 59.00 130.00 58.00 58.00 128.00 99.00 107.00 107.00 100.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.70 9.60 MAX. KV 9.90
103.00 126.00 MAX. AMP. 135.00
0.96 0.96 MAX. F.P. 0.96
1744 2108 MAX. KVA 2267 MIN. KVA 1051
1682 2023 MAX. KW 1009
459 588 MAX. KVAR 637
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
102.00 125.00 MAX. AMP. 131.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.70 9.60 9.70 9.70 9.80 97.00 9.80 9.60 9.90
CELDA ENTRADA

A 120.00 103.00 103.00 107.00 108.00 109.00 109.00 133.00 73.00


P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 2014 1723 1752 1825 1826 1869 1865 2217 1220
KW 1936 1663 1689 1761 1759 1800 1799 2130 1170
KVAR 554 452 461 490 487 498 497 626 345
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 119.00 100.00 102.00 107.00 107.00 108.00 107.00 130.00 68.00


3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/14/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.90 9.60 9.80 9.80 9.90 9.40 9.60 9.90 9.70 9.70 9.70 9.80
74.00 731.00 74.00 75.00 76.00 735.00 726.00 60.00 118.00 108.00 108.00 108.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1240 2186 1227 1247 1264 2205 2123 1008 1992 1824 1823 1834
1190 2098 1179 1190 1213 2123 2030 967 1912 1760 1759 1767
354 619 351 356 361 628 591 281 546 484 485 487

69.00 129.00 69.00 70.00 71.00 132.00 122.00 56.00 115.00 107.00 106.00 106.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.70 9.90 MAX. KV 97.00
109.00 110.00 MAX. AMP. 735.00
0.96 0.96 MAX. F.P. 0.96
1840 1829 MAX. KVA 2217 MIN. KVA 1008
1775 1764 MAX. KW 967
489 491 MAX. KVAR 628
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
108.00 108.00 MAX. AMP. 132.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.70 9.70 9.60 9.60 9.60 9.60 9.70 9.70 9.70 9.70
CELDA ENTRADA

A 109.00 107.00 108.00 109.00 109.00 111.00 108.00 107.00 108.00 116.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 1838 1817 1809 1831 830 1867 1823 1812 1814 1945
KW 1771 1751 1746 1763 1762 1799 1756 1743 1744 1869
KVAR 490 483 483 491 490 503 486 484 485 532
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 10.00 106.00 106.00 108.00 108.00 110.00 107.00 104.00 103.00 116.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/15/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.60 9.90 9.70 9.70 9.70 9.70 9.70 9.70 9.70 9.70 9.70 9.70
116.00 55.00 118.00 113.00 57.00 120.00 119.00 115.00 110.00 110.00 115.00 110.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1927 913 1984 1939 1925 2012 2008 1945 1865 1865 1945 1865
1854 876 1906 1866 1852 1932 1930 1871 1798 1798 1871 1798
528 247 545 530 525 556 554 532 502 502 532 502

117.00 51.00 115.00 112.00 52.00 116.00 117.00 112.00 104.00 104.00 112.00 104.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.70 9.70 MAX. KV 9.90
63.00 64.00 MAX. AMP. 120.00
0.96 0.96 MAX. F.P. 0.96
1039 1050 MAX. KVA 2012 MIN. KVA 830
998 1010 MAX. KW 876
292 301 MAX. KVAR 556
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
58.00 59.00 MAX. AMP. 117.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.50 9.50 9.70 9.70 9.70 9.70 9.80 9.80 9.70 9.60
CELDA ENTRADA

A 124.00 115.00 108.00 109.00 109.00 109.00 110.00 111.00 122.00 104.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 2044 1896 1828 1827 1829 1827 1850 1851 2042 1941
KW 1965 1821 1756 1756 1759 1757 1787 1788 1964 1681
KVAR 570 517 487 489 490 490 496 495 567 462
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 122.00 113.00 105.00 106.00 108.00 107.00 108.00 107.00 117.00 101.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/16/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00 21:00
9.50 9.60 9.70 9.90 9.90 9.80 9.50 9.70 9.70
114.00 122.00 101.00 57.00 60.00 122.00 115.00 108.00 109.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1890 2040 1707 656 1004 2063 1896 1828 1827
1823 1980 1645 917 963 1984 1821 1756 1756
516 570 450 261 280 570 517 487 489

110.00 116.00 98.00 53.00 56.00 119.00 113.00 105.00 106.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.70 9.70 MAX. KV 9.90
109.00 109.00 MAX. AMP. 124.00
0.96 0.96 MAX. F.P. 0.96
1829 1827 MAX. KVA 2063 MIN. KVA 656
1759 1757 MAX. KW 917
490 490 MAX. KVAR 570
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
108.00 107.00 MAX. AMP. 122.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.80 9.90 9.60 9.70 9.70 9.70 9.70 9.70 9.60 9.70
CELDA ENTRADA

A 65.00 66.00 114.00 112.00 111.00 104.00 105.00 110.00 123.00 108.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 1084 1102 1919 1895 1885 1755 1780 1859 2094 1809
KW 1040 1056 1843 1824 1814 1692 1722 1793 2012 1745
KVAR 307 312 518 509 506 466 480 503 584 485
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 60.00 61.00 111.00 119.00 109.00 101.00 102.00 106.00 120.00 104.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/17/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
98.00 9.80 9.50 9.60 9.80 9.70 9.60
106.00 58.00 128.00 123.00 111.00 112.00 112.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1802 959 2130 2077 1883 1886 1880
1736 921 2044 1993 1812 1814 1816
484 261 595 578 509 507 508

103.00 53.00 124.00 121.00 106.00 108.00 109.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.30 9.70 MAX. KV 98.00
134.00 67.00 MAX. AMP. 134.00
0.96 0.96 MAX. F.P. 0.96
2183 1103 MAX. KVA 2183 MIN. KVA 959
2093 1058 MAX. KW 921
620 317 MAX. KVAR 620
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
132.00 62.00 MAX. AMP. 132.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.50 9.50 9.80 9.80 9.60 9.80 9.60 9.90 9.80 9.60
CELDA ENTRADA

A 140.00 137.00 74.00 76.00 135.00 107.00 130.00 74.00 75.00 125.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 2320 2269 1232 1267 2269 1835 2177 1248 1249 2089
KW 2221 2173 1180 1206 2176 1766 2086 1195 1197 2007
KVAR 668 647 353 362 648 488 610 358 359 585
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 137.00 135.00 69.00 71.00 132.00 104.00 127.00 69.00 70.00 120.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/18/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.70 9.60 9.60 9.60 9.80 9.70 9.60 9.50 9.50 9.80 9.80 9.60
126.00 75.00 76.00 126.00 73.00 76.00 78.00 77.00 76.00 75.00 75.00 78.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
2125 1228 1120 2120 1214 1255 1240 1235 1222 1247 1247 1278
2041 1175 1036 2036 1164 1203 1184 1181 1170 1195 1195 1223
594 354 363 593 345 365 306 366 356 356 356 374

123.00 70.00 73.00 123.00 69.00 72.00 71.00 72.00 72.00 70.00 70.00 73.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.50 9.50 MAX. KV 9.90
142.00 116.00 MAX. AMP. 142.00
0.96 0.96 MAX. F.P. 0.96
2348 1937 MAX. KVA 2348 MIN. KVA 1120
2246 1865 MAX. KW 1036
678 531 MAX. KVAR 678
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
139.00 113.00 MAX. AMP. 139.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.80 9.70 9.50 9.50 9.50 9.50 9.50 9.60 9.60 9.70
CELDA ENTRADA

A 62.00 65.00 124.00 124.00 114.00 114.00 114.00 113.00 114.00 73.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 1025 1062 2062 2072 1881 1891 1895 1903 1904 1240
KW 987 1020 1983 1993 1812 1820 1823 1832 1836 1193
KVAR 286 302 575 578 513 514 515 518 518 355
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 58.00 60.00 121.00 122.00 111.00 110.00 110.00 110.00 111.00 70.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/19/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.70 9.70 9.70 9.80 9.40 9.80 9.70 9.50 9.50 9.60 9.80
75.00 136.00 74.00 75.00 136.00 73.00 76.00 136.00 116.00 113.00 64.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1247 2206 1211 1244 2241 1211 1239 2249 1894 1884 1060
1194 2114 1160 1196 2150 1163 1186 2154 1825 1815 1012
359 558 345 358 638 343 358 641 513 511 296

71.00 131.00 70.00 71.00 134.00 68.00 71.00 132.00 111.00 109.00 59.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.80 9.30 MAX. KV 9.80
67.00 139.00 MAX. AMP. 139.00
0.96 0.96 MAX. F.P. 0.96
1109 2244 MAX. KVA 2249 MIN. KVA 1025
1063 2149 MAX. KW 987
318 642 MAX. KVAR 642
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
62.00 136.00 MAX. AMP. 136.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.60 9.70 9.40 9.40 9.50 9.50 9.60 9.70 9.70 9.60
CELDA ENTRADA

A 66.00 67.00 130.00 130.00 116.00 116.00 116.00 115.00 114.00 127.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 1082 1103 2146 2107 1939 1919 1923 1921 1919 2130
KW 1037 1057 2060 2022 1865 1845 1852 1850 1847 2044
KVAR 308 316 607 594 531 525 524 524 523 596
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 61.00 62.00 127.00 128.00 113.00 115.00 114.00 111.00 110.00 123.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/20/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.60 9.50 9.60 9.50 9.60 9.50 9.60 9.40 9.60 9.50 9.70
77.00 136.00 114.00 132.00 74.00 74.00 77.00 138.00 113.00 132.00 66.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1246 2251 1909 2187 1209 1210 1256 2254 1884 2193 1085
1191 2159 1838 2097 1159 1160 1203 2162 1814 2104 1040
360 645 520 619 345 347 364 644 511 620 308

72.00 134.00 111.00 129.00 69.00 71.00 71.00 133.00 109.00 129.00 61.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.60 9.30 MAX. KV 9.70
69.00 139.00 MAX. AMP. 139.00
0.96 0.96 MAX. F.P. 0.96
1116 2242 MAX. KVA 2254 MIN. KVA 1082
1070 2148 MAX. KW 1037
325 639 MAX. KVAR 645
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
64.00 136.00 MAX. AMP. 136.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.50 9.70 9.60 9.60 9.60 9.60 9.50 9.50 9.40 9.40
CELDA ENTRADA

A 122.00 67.00 129.00 115.00 115.00 111.00 111.00 132.00 134.00 130.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 2025 1102 2146 1910 1914 1852 1850 2190 2193 2133
KW 1946 1057 2060 1838 1834 1782 1782 2100 2106 2045
KVAR 565 316 605 521 522 500 502 609 621 600
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 119.00 62.00 126.00 113.00 113.00 108.00 107.00 129.00 130.00 127.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/21/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.50 9.60 9.50 9.50 9.70 9.50 9.70 9.40 9.50 9.50 9.70
75.00 7.50 130.00 129.00 71.00 73.00 74.00 135.00 112.00 132.00 66.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1199 1224 2157 2150 1158 1160 1209 2214 1864 2193 1085
1147 1171 2072 2060 1112 1120 1159 2117 1793 2104 1040
346 354 606 601 325 328 346 627 506 620 308

71.00 70.00 126.00 125.00 66.00 70.00 70.00 132.00 107.00 129.00 61.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.60 9.30 MAX. KV 9.70
69.00 139.00 MAX. AMP. 139.00
0.96 0.96 MAX. F.P. 0.96
1116 2242 MAX. KVA 2242 MIN. KVA 1085
1070 2148 MAX. KW 1040
325 639 MAX. KVAR 639
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
64.00 136.00 MAX. AMP. 136.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.40 9.80 9.40 9.40 9.50 9.50 9.60 9.80 9.80 9.50
CELDA ENTRADA

A 137.00 66.00 130.00 130.00 116.00 116.00 116.00 95.00 96.00 100.00
P.F. 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 2238 1086 2146 2107 1939 1919 1923 1623 1633 1663
KW 2145 1040 2060 2022 1865 1845 1852 1566 1575 1606
KVAR 640 309 607 594 531 525 524 422 425 439
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 132.00 60.00 127.00 128.00 113.00 115.00 114.00 94.00 94.00 99.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/22/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.50 9.60 9.60 9.60 9.70 9.40 9.50 9.70 9.70 9.50 9.50 9.40
97.00 99.00 106.00 111.00 114.00 115.00 113.00 111.00 111.00 128.00 127.00 126.00
0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
1616 1645 1776 1865 1907 1887 1878 1876 1876 2132 2130 2063
1559 1589 1713 1795 1833 1815 1809 1806 1808 2045 2044 1987
423 434 478 504 519 516 512 510 508 598 597 570

96.00 97.00 105.00 111.00 112.00 115.00 113.00 110.00 110.00 125.00 126.00 123.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
9.60 9.70 MAX. KV 9.80
72.00 73.00 MAX. AMP. 137.00
0.96 0.96 MAX. F.P. 0.96
1164 1202 MAX. KVA 2238 MIN. KVA 1086
1118 1153 MAX. KW 1040
332 343 MAX. KVAR 640
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
67.00 69.00 MAX. AMP. 132.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 9.40 9.60 9.50 9.70 9.70 9.60 9.60 9.60 9.40 9.50
CELDA ENTRADA

A 131.00 125.00 123.00 72.00 73.00 106.00 109.00 111.00 113.00 113.00
P.F. 0.96 0.96 0.96 96.00 0.96 0.96 0.96 0.96 0.96 0.96
J01

KVA 2152 2097 2053 1174 1203 1820 1823 1855 1857 1867
KW 2062 2014 1974 1124 1153 1755 1757 1785 1788 1795
KVAR 607 586 571 334 345 489 490 504 509 509
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A 126.00 122.00 119.00 66.00 68.00 105.00 105.00 110.00 112.00 112.00
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/23/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00
9.40 9.30 9.50 9.60 9.40 9.50 9.40 9.50 9.60 9.60 9.60 9.70
134.00 120.00 110.00 110.00 112.00 110.00 111.00 111.00 110.00 114.00 128.00 72.00
0.95 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96 0.96
2187 1942 1827 1838 1834 1824 1834 1850 1849 1907 2155 1173
2095 1866 1761 1771 1767 1754 1761 1782 1780 1838 2069 1124
623 538 492 498 500 497 501 502 501 519 604 331

133.00 119.00 109.00 109.00 109.00 109.00 109.00 108.00 109.00 111.00 126.00 66.00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
0.70 9.40 MAX. KV 9.70
73.00 133.00 MAX. AMP. 134.00
0.96 96.00 MAX. F.P. 96.00
1205 2190 MAX. KVA 2190 MIN. KVA 1173
1154 2099 MAX. KW 1124
345 620 MAX. KVAR 623
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
68.00 128.00 MAX. AMP. 133.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV
CELDA ENTRADA

A
P.F.
J01

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/24/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV
CELDA ENTRADA

A
P.F.
J01

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/25/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV 10.40
CELDA ENTRADA

A 229.00
P.F. 0.77
J01

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/26/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00 21:00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
MAX. KV 10.40
MAX. AMP. 229.00
MAX. F.P. 0.77
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV
CELDA ENTRADA

A
P.F.
J01

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/27/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV
CELDA ENTRADA

A
P.F.
J01

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 2/28/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 21:00 21:00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 °C
22:00 23:00 TOTAL CONSUMO
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
CE
CELDA 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00
KV
CELDA ENTRADA

A
P.F.
J01

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
150KVA

P.F.
J02

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
KV
CELDA TRANSF.

A
3000KVA

P.F.
J03

KVA
KW
KVAR
KW/H
KVA/H
KVAR/H
OPERADOR DE TURNO 06:00 A 18:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°1
OPERADOR DE TURNO 18:00 A 06:00Hrs TEMPERATURA DE TRANSFORMADOR 3000KVA - TURNO N°2
FECHA : 3/1/2019
CELDAS DE MEDIA TENSIÓN 10KV
10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00 21:00

ANSFORMADOR 3000KVA - TURNO N°1 °C


ANSFORMADOR 3000KVA - TURNO N°2 40/60 °C
22:00 23:00 TOTAL CONSUMO
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0
MAX. KV 0.00
MAX. AMP. 0.00
MAX. F.P. 0.00
MAX. KVA 0 MIN. KVA 0
MAX. KW 0
MAX. KVAR 0
TOTAL KW/H 0
TOTAL KVA/H 0
TOTAL KVAR/H 0

También podría gustarte