C
CONTENTS
PART A: INFOR
P RMATION FOR THHE USER 17.0 SCRAPPING THE UNIT
1.0 GENEERAL FEATURESS 18.0 LIST OF SPA
ARE PARTS FOR
R ROUTINE MAIN
NTENANCE
2
2.0 INTEN
NDED USE 19.0 TROUBLE-SHHOOTING AND EMERGENCY
E RE
EMEDIES
3
3.0 OPERRATION
4
4.0 GENEERAL SAFETY STTANDARDS PART B: INFORMATIO
ON RESERVED FORF TECHNICALLY SKILLED
PERSONNEL
55.0 DESC
CRIPTION OF DA
ANGER WARNINGS 20.0 STARTING UP
U
6
6.0 DANG
GER ZONES 21.0 GENERAL ORRDINARY MAINTTENANCE REQU UIRES
TRAINED PE
ERSONNEL
77.0 SAFET
TY DEVICES 22.0 CHANGING TTHE OIL
8
8.0 POSIT
TION OF PLATES
S 23.0 CHANGING TTHE OIL FILTER
R AND OIL SEPAR
RATOR
FILTER
99.0 COMPPRESSOR ROOM M 24.0 OLEOPNEUMMATIC DIAGRAM M
10.0 TRANSPORT AND HA ANDLING 25.0 CALIBRATION FOR DRYER
11.0 UNPAACKING
12.0 INSTA
ALLATION
13.0 DIMENNSIONS AND TE
ECHNICAL DATA
A
14.0 MACHHINE DESCRIPTION IMPORTTANT: A COPY OF
O THE WIRING
G DIAGRAMS CA
AN BE FOUND
IN THE ELECTRIC CAB
BINET OF COMP
PRESSOR.
15.0 ORDIN
NARY MAINTENANCE TO BE DO
ONE BY THE US
SER
16.0 PERIO
ODS OF INACTIV
VITY
Cod. 98
828093011 00 - Edition 03//2015 - 1
ENGLISH
MACHINE AND MANUFACTURER IDENTIFICATION DATA
1
1) Position of the identification plate
ADDRESSES OF ASSISTANCE CENTRES
In the event of breakdown or malfunction of the machine, switch it off and do not tamper with it. If repairs are needed, apply only to a
technical assistance centre approved by the manufacturer and insist on the use of original spare parts.
Failure to comply with the above may endanger the safety of the machine.
INTRODUCTION
Keep this manual with care for future consultation; the use and maintenance manual is an integral part of the machine. Read this
manual carefully before carrying out any work on the compressor unit.
The installation of the compressor unit and all operations involving it must be performed in conformity with the regulations in
force concerning electric plants and personal safety.
CHARACTERISTICS AND SAFETY PRECAUTIONS
2) DANGEROUS ELECTRIC 8) MOVING PARTS
VOLTAGE
3) AIR NOT FIT FOR BREATHING 9) MACHINE WITH AUTOMATIC START
4) NOISE
5) HIGH PRESSURE
11.0 UNPACKING
After removing the packing, ensure that the machine is unbroken and that there are no visibly damaged parts.
If you are in doubt, do not use the machine but contact the manufacturer or to your dealer. The packing material (plastic bags) must not be
left within the reach of children or abandoned in the environment, as they are a potential source of danger and pollution. Dispose of these
materials in the approved collection centres.
NEVER OPERATE THE COMPRESSOR ON A VOLTAGE OTHER DIFFERENT THAN SHOWN ON THE ELECTRIC CABINET.
For tri-voltage machine follow the instructions in the electrical diagram (inside cubicle) to convert the
operating voltage of the compressor for either 208V or 230V or 460V
Air Air
Dimensions mm (in) Dimensions mm (in)
connection connection
L W H D L W H D
1526 830 1555
HP 40-50 2022 830 1555
HP 40-50 - kW 30-37 1”1/4 1”1/4
(60) (32,6) (61,2) kW 30-37 (79,6) (32,6) (61,2)
Weight kg. (lb) Weight kg. (lb) (with dryer)
HP 40 - kW 30 555 (1223,5) HP 40 - kW 30 670 (1477)
HP 50 - kW 37 618 (1362,4) HP 50 - kW 37 723 (1594)
HP 40 - kW 30 HP 50 - kW 37
Max. pressure bar (psi) 7,5 8,5 10 13 7,5 8,5 10 13
(108) (123) (145) (188) (108) (123) (145) (188)
Standard air capacity m3/h (cfm) 335 306 281 245 374 346 310 281
(197) (180) (165) (144) (220) (203) (182) (165)
Noiose product. dB(A) 68 69
Oil operation timer setting °C (°F) 60 (140) 63 (145,4)
Oil load lt. (gal) 22,5 (5,95) 22,5 (5,95)
Bar (psi)
Type Freon Nominal Nominal Nominal MAX.
Power Power
Dryer R 404A Kg. (lb) Power W (HP)
W (HP) W (HP)
50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
A 8+ See data plate 996 (1,33) 1035 (1,38) 140 (0,18) 194 (0,26) 1136 (1,52) 1229 (1,64) bar 13 (188)
A 10 dryer 1296 (1,73) 1455 (1,95) 150 (0,20) 190 (0,25) 1446 (1,93) 1645 (2,20) bar 13 (188)
Reference conditions: Limit conditions:
Ambient temperature 25 °C (77 °F) Max. ambient temperature 46°C (114,8 °F)
Inlet air temperature 35 °C (95 °F) Min. ambient temperature 4°C (39,2 °F)
Pressure 7 bar (101,5 psi) Max. working pressure 13 bar (188 psi)
Dew point in pressure 3 °C (37,4 °F)
2 7 S3
4
1
5
16 14 17 6
There is an electronic controller on the electric panel ; this controller includes the display of the functions as shown in figure 15.
1 Stop button (0) 10 Automatic operation led
2 Start button (I) 11 Automatic operation symbol
3 Display 12 Service warning led
4 Reset button 13 Service warning symbol
5 Enter key 14 Downward scroll key
6 Voltage on led 15 Upward scroll key
7 Voltage on symbol 16 Left scroll key
8 General alarm led 17 Right scroll key
9 General alarm symbol
CAUTION: WAIT AT LEAST 20 SECONDS BEFORE STARTING THE MACHINE AFTER SWITCH OFF.
Introduction:
The controller performs the following functions:
- Compressor control
- Compressor protection
- Maintenance monitoring
- Automatic restart after supply interruption (optional).
Automatic control of the compressor
The controller maintains the outlet pressure within defined limits, commanding the load and unload operations of the compressor. Various
parameters are considered, among them are: the unload pressure, the load pressure, the minimum stop time and the maximum number of motor
starts.
Compressor protection
Shutdown
If outlet temperature of the element exceeds the programmed shut down level, the compressor will be stopped. This will be indicated on the display
(3). The compressor will also stop if a motor overload occurs.
Motor stopped.
3)
When the compressor is stopped, the icon stands still.
4)
When the compressor is running, the icon is rotating.
Element outlet temperature.
5)
Dew-point (dryer equipped version).
6)
Motor overload or phase sequence incorrect or outlet element overtemperature detected
7) by temperature switch
Emergency stop activated.
8)
Pictograph: service.
9)
Remote start / stop
10)
LAN control or network setting.
11)
Automatic restart after voltage failure is active
12)
Timer
13)
Main screen
When the voltage is switched on, the main screen is shown automatically, indicating the operation status of the compressor and the outlet
temperature.
example:
The display is showing that the compressor is running loaded (when the horizontal arrow is blinking) and the outlet pressure is 6.8bar.
Consult the service dept. if <test> appears on the display.
The screen shows that the temperature at the outlet of the compressor element is 122°C (251,6 °F).
Isolate the compressor from its power supply line of the compressor.
WARNING: The unit must be disconnected from the power supply net!
Inspect the unit and rectify.
After rectifying and when the shut-down condition has disappeared, switch on the voltage and restart the compressor.
Motor overload
In case of motor overload, the compressor will be shut-down, the alarm led (8) will blink, the automatic operation led (10) will switch off and the
following type of screen will appear:
Take care that the shut-down “Overload motor” appears in case of main motor overload or incorrect phase sequence (detected by phase sequence
relay) or overtemperature detected by temperature switch.
Isolate the compressor from its power supply line of the compressor.
WARNING: The unit must be disconnected from the power supply net!
Inspect the unit and remedy.
After rectifying and when the shut-down condition has disappeared, switch on the voltage and restart the compressor.
The screen shows that the reading of the service timer is 4002h.
Using the keys (14) or (15), scroll to the screen <d.01> and the running hours symbol will be shown.
Press the key (5) and the actual running hours will appear in <hrs> (or in <x1000hrs> if the value is higher than 9999).
Press the scroll key (14) until the screen <d.06> appears, then press enter key (5):
This screen shows the unit used is <hrs> (or <x1000 hrs>) and the value 1191: the compressor has run 1191 h since the previous service.
Resetting the service timer
After servicing, see section Service warning, the timer has to be reset:
Scroll to register screen <d.06> and press enter key (5).
The reading (e.g. 4000) will appear.
Press the enter key (5). If a password is set, enter the password.
The icon will flash (indicating that resetting is possible).
Press the enter key (5) to reset the timer to <0.000> or press reset key (4) to cancel the operation.
Scrolling through all screens
Scroll buttons (14) can be used to scroll through all screens. The screens are divided into register screens, measured data screens, digital input
screens (numbered as <d.in>, <d. 1>, ...), parameter screens (numbered as <P.1>, <P.2>, ...), protections screens (numbered as
<Pr.2>,...) and test screens (numbered as <t.1>,...).
During scrolling, the numbers of the screens appear consecutively. For most screens, the unit of measurement and the related pictograph are
shown together with the screen number.
Example
The screen shows the screen number <d.1>, the unit used <hrs> and the related symbol for running hours. Press Enter key (5) to call up the actual
running hours.
Overview of the screens
Digital input screens Designation Related topic
Simplified menu flow
Ref. Description Ref. Description
(1) Compressor outlet pressure (16) Pressure band setting
(2) Compressor outlet temperature (17) Service timer settings
(3) Dewpoint temperature (18) Temperature unit
(4) Digital input status (19) Unit pressure
(5) Running hours (20) Auto restart
(6) Motor starts (21)
(7) Module hours (22) Load delay time
(8) Loading hours (23) Minimum stop time
(9) Load relay (24) Password settings
(10) Service timer reading (25) Remote pressure sensing
(11) Actual program version (26) Protections
(12) LAN selection (27) Display test
(13) Settings node ID (28) Safety valve test
(14) IP settings (29)
(15) Pressure band selection
8
2
10 6
11 14
12 7 13
Function keys of the controller
Reference Designation Function
1 Display Shows icons and operating conditions.
2 Automatic operation symbol
3 LED, Automatic operation Indicates that the regulator is automatically controlling the compressor: the compressor is loaded,
unloaded, stopped and restarted depending on the air consumption and the limitations
programmed in the regulator.
4 Warning symbol
5 LED, Warning Is lit if a warning condition exists.
6 Voltage symbol
7 LED, Voltage on Indicates that the voltage is switched on.
8 Service symbol
9 LED, Service Is lit when service is needed.
10 Start button This button starts the compressor. Automatic operation LED (3) lights up. The Elektronikon is
operative.
11 Stop button This button is used to stop the compressor. Automatic operation LED (3) goes out.
12 Scroll buttons Use these buttons to scroll through the menu .
13 Enter button Use this button to confirm the last action.
14 Escape button Use this button to go to previous screen or to end the current action.
Running loaded
Network control
Automatic restart after
Automatic restart after voltage failure is active
voltage failure
Week timer Week timer is active
Active protection functions Emergency stop
Shutdown
Warning
Service Service required
Not valid
System icons
Icon Description Icon Description
Compressor element (LP, HP, ...) Motor
Menu icons
Icon Description Icon Description
Inputs Event history (saved data)
Outputs Access key / User password
Protections (Warnings, shutdowns) Network
Counters Setpoint
Test Information
Regulation (Settings) Week Timer
Service General
Navigation arrows
Up Down
Main screen
Function
The Main screen is the screen that is shown automatically when the voltage is switched on and one of the keys is pushed. It is switched off
automatically after a few minutes when no keys are pushed.
Typically, 5 different main screen views can be chosen:
Two value lines
Four value lines
Chart (High resolution)
Chart (Medium resolution)
Chart (Low resolution)
Two and four value lines screens
This type of Main screen shows the value of 2 or 4 parameters (see section Inputs menu).
Typical Main screen (2 value lines), fixed speed compressors Typical Main screen (4 value lines), fixed speed compressors
Text on figures
(1) Compressor Outlet
(2) Element outlet
(3) Load, ... (text varies upon the compressors actual condition)
(4) Menu
(5) Running hours
(6) Dryer dew point temperature (Only if dryer is present)
Section A shows information regarding the compressor operation (e.g. the outlet pressure or the temperature at the compressor outlet).
Section B shows Status icons. Following icon types are shown in this field:
Fixed icons
These icons are always shown in the main screen and cannot be selected by the cursor (e.g. Compressor stopped or running, Compressor
status (running, running unloaded or motor stopped).
Optional icons
These icons are only shown if their corresponding function is activated (e.g. week timer, automatic restart after voltage failure , etc.)
Pop up icons
These icons pop up if an abnormal condition occurs (warnings, shutdowns, service,...)
To call up more information about the icons shown, select the icon concerned using the scroll keys and press the enter key.
Section C is called the Status bar. This bar shows the text that corresponds to the selected icon.
To go to the Menu screen, highlight the Menu button (4), using the Scroll keys. Press the Enter key to select the menu. Following screen
appears:
The screen shows a number of icons. Each icon indicates a menu item. By default, the Pressure Settings (Regulation) icon is selected. The
status bar shows the name of the menu that corresponds with the selected icon.
Use the Scroll keys to select an icon. Press the Escape key to return to the Main screen.
Shut-down warning visualization
In case of shut-down warning a yellow triangle (1) pops up in the lower side of the display as in the picture below in the left side:
To check which is the warning, highlight the yellow triangle, using the Scroll keys. Press the Enter key and it will appears the Protections
menu as in picture above in the right side. Press Enter key and then in the display will appear the list of the Protection that are active on the
controller. Use Scroll key to check all the protections and the one who is causing the warning will be highlighted as in picture below:
Stop the compressor pressing the button (11) in the Fig. 17A and wait until the compressor stops.
Open the disconnect switch in the supply line of the compressor.
WARNING: Before carrying out any maintenance the machine must be stopped, cut off the machine from the electrical
mains and from the compressed air distribution circuit, check that the machine is not under pressure.
Inspect the compressor and remedy.
To check which is the shutdown, highlight the red icon, using the Scroll keys. Press the Enter key and it will appears the Protections menu
as in picture above in the right side. Press Enter key and then in the display will appear the list of the Protection that are active on the
controller. Use Scroll key to check all the protections and the one who is causing the shutdown will be highlighted as in picture below:
Take care that the shut-down “Overload motor” appears in case of main motor overload or incorrect phase sequence (detected by phase
sequence relay) or overtemperature detected by temperature switch.
Open the disconnect switch in the supply line of the compressor.
WARNING: Before carrying out any maintenance the machine must be stopped, cut off the machine from the electrical
mains and from the compressed air distribution circuit, check that the machine is not under pressure.
Inspect the compressor and remedy.
After remedying and when the shut-down condition has disappear, switch on the voltage and restart the compressor.
Inputs menu
Function: to display the actual value of the measured data (analog inputs) and the status of the digital inputs (e.g. emergency stop contact,
motor overload relay, etc.) and to select the digital input to be shown on the chart in the main screen.
Procedure
Starting from the main screen (see Main screen),move the cursor to the action button Menu and press the Enter key.
Using the Scroll keys, move the cursor to the Inputs icon, as shown in the following screen:
Press the Enter key. A screen similar to the one below appears:
(1) Inputs
(2) Compressor outlet
(3) Element outlet
(4) Ambient air
(5) Emergency stop
The screen shows a list of all inputs with their corresponding icons and readings.
If an input is in warning or shutdown, the original icon is replaced by the warning or shutdown icon respectively (i.c. the Stop icon and the
Warning icon in the screen shown above).
A small chart icon, shown below an item in the list means this input signal is shown on the chart at the main screen. Any analog input can be
selected.
The screen shows a list of all counters with their actual readings.
Next, use the scroll buttons to go to the Status icons (see Main screen) and select the Regulation icon (2). When the icon is active, this icon
is highlighted with a grey background colour.
Press the enter button:
(1) Overview
(2) Running Hours
(3) Real Time hours
(4) Reset
Example for service level (A): the figures at the left are the programmed service intervals. For Service interval A, the programmed number of
running hours is 4000 hours (upper row, green) and the programmed number of real time hours is 8760 hours, which corresponds to one year
(second row, blue). This means that the controller will launch a service warning when either 4000 running hours or 8760 real hours are
reached, whichever comes first. Note that the real time hours counter keeps counting, also when the controller is not powered.
The figures at the end of the bars are the number of hours to go till the next service intervention. In the example above, the compressor was
just started up, which means it still has 4000 running hours or 8299 hours to go before the next Service intervention.
Service plans
A number of service operations are grouped (called Level A, Level B, etc...). Each level stands for a number of service actions to be carried
out at the time intervals programmed in the controller.
When a service plan interval is reached, a message will appear on the screen.
After carrying out the service actions related to the indicated levels, the timers must be reset. From the Service menu above, select Service
plan (3) and press Enter. Following screen appears:
(1) Service plan
(2) Level
(3) Running hours
(4) Real time hours
(5) Modify
In the example above, the A Service level is programmed at 4000 running hours, of which 0 hours have passed. History
The History screen shows a list of all service actions done in the past, sorted by date. The date at the top is the most recent service action.
To see the details of a completed service action (e.g. Service level, Running hours or Real time hours), use the Scroll keys to select the
desired action and press the Enter key.
Regulation menu
Function: on fixed speed compressors , the operator can program two different pressure bands. This menu is also used to select the active
pressure band.
Procedure: starting from the Main screen (see Main screen), move the cursor to the action button Menu and press the Enter key.
Using the Scroll keys, move the cursor to the Setpoint icon (see below).
Press the Enter key. Following screen appears:
(1) Regulation
(2) Unloading pressure 1
(3) Loading pressure 1
(4) Unloading pressure 2
(5) Loading pressure 2
(6) Modify
The screen shows the actual unloading and loading pressure settings for both pressure bands. To modify the settings, move the cursor to
the action button Modify and press the Enter key. Following screen appears:
The first line of the screen is highlighted. Use the Scroll keys to highlight the setting to be modified and press the Enter key. Following
screen appears:
The upper and lower limit of the setting is shown in grey, the actual setting is shown in black. Use the ↑ or ↓ key of the Scroll keys to modify
the settings as required and press the Enter key to accept.
If necessary, change the other settings as required in the same way as described above.
Event history menu
Function: to call up the last shut-down and last emergency stop data.
Procedure: starting from the Main screen (see Main screen), move the cursor to the action button Menu and press the Enter key.
Using the Scroll keys, move the cursor to the Event History icon (see below).
Press the Enter key. The list of last shut-down and emergency stop cases is shown.
Example of Event History screen
Scroll through the items to select the desired shut-down or emergency stop event.
Press the Enter key to find the date, time and other data reflecting the status of the compressor when that shut-down or emergency stop
occurred.
Modifying general setting
Function: to display and modify a number of general settings.
Procedure: starting from the Main screen (see Main screen), move the cursor to the action button Menu and press the Enter key.
Using the Scroll keys, move the cursor to the Settings icon (see below).
(1) General
(2) Language in use
(3) Time
(4) Date
(5) Date format
(6) Modify
A screen similar to the one above is shown, a selection bar is covering the first item (Language). Use the ↓ key of the Scroll keys to select
the setting to be modified and press the Enter key.
To modify, select the Modify button using the Scroll keys and press the Enter key.
A pop-up screen appears. Use the ↑ or ↓ key to select the required parameter and press the Enter key to confirm.
Restart delay This parameter allows to programme that not all compressors are restarted at the same time after a power failure
(ARAVF active).
Compressor element outlet The regulator does not accept inconsistent settings, e.g. if the warning level is programmed
at 95 ˚C (203 ˚F), the minimum limit for the shut-down level changes to 96 ˚C (204 ˚F). The
recommended difference between the warning level and shut-down level is 10 ˚C (18 ˚F).
Delay at shut- down signal Is the time for which the signal must exist before the compressor is shut down. If it is required to program this
setting to another value, consult your supplier.
Minimum stop time Once the compressor has automatically stopped, it will remain stopped for the minimum stop time, whatever
happens with the net air pressure. Consult your supplier if a setting lower than 20 seconds is required.
Unloading/ Loading The regulator does not accept illogical settings, e.g. if the unloading pressure is programmed at 7.0 bar(e) (101
pressure psi(g)), the maximum limit for the loading pressure changes to 6.9 bar(e) (100 psi(g)). The recommended
minimum pressure difference between loading and unloading is 0.6 bar (9 psi(g)).
Every 50 working hours Drain condensate from the oil tank
Check the oil level
Clean the filter of the automatic condensate drain (dryer)
Every 500 hours Replace oil filter (at first 500 hrs)
Tighten the screws fixing the electric cables (at first 500 hrs)
Clean the air inlet filter
Clean the condenser heat exchanger (unit with dryer)
Clean the inlet filtration panels
Every 2000 hours Replace the inlet air filter
Replace the oil filter
Retighten all power cable connections
Safety temperature test
Maintenance kit of the automatic condensate drain (dryer)
Oil Fluid sample
Every 4000 hours Clean the finned surface of the air-oil cooler
Replace the oil separator filter
Every 8000 hours Intake service kit
Check status of oil return valve and oil pipes
MPV Service kit
Replace the oil *
* The compressor must be maintained with QuinSyn‐Plus (8,000 hour maximum), QuinSyn‐XP (12,000 hour
maximum) or QuinSyn‐F food grade (6,000 hour maximum). Maximum fluid change intervals are noted per fluid.
Actual fluid change interval is to be determined by fluid sampling report, not to exceed maximum fluid change
interval. Fluid samples must be taken every 2,000 hours or as directed by the analysis report. For light usage
units, a fluid sample must be taken a minimum, of every six (6) months, beginning at start‐up.
3
2
5
4
1
8
7 6
15.8 CLEAN THE DRAIN MESH (ONLY FOR UNITS EQUIPPED WITH REFRIGERANT DRYER)
Proceed as follows:
- Close the ball valve at machine at the air outlet Ref. 5 Ref. 20
- Depressurise the dryer by pressing the "TEST" button on drain (for about 10-20 seconds) Ref. 1 Fig.20
- Switch off the machine with push button Ref. 4 Fig. 20: in this way the machine stops after idle time running.
- Turn off the isolator switch, Ref. 2 (on the screw-compressor) and Ref. 3 (on the dryer if fitted) Fig. 20.
- Remove the panel Ref. 8 Fig. 20 (only for HP 40-50 / kW 30-37)
- Remove the threaded plug Ref. 6 Fig. 20
- Remove the filter Ref. 7 Fig. 20 (filter mesh)
- Clean the filter mesh using compressed air.
- Install the filter, fix the plug.
- Install the panel Ref. 8 Fig. 20 (only for HP 40-50 / kW 30-37)
2
1
4
Fig. A
4
1
3
2
8
During periods of inactivity the unit needs to be protected against atmospheric agents, dust and humidity which could damage the motor and
the electrical system.
To restart the machine after periods of inactivity, consult the manufacturer.
17.0 SCRAPPING THE UNIT
If the machine needs to be scrapped, it must be dismantled into parts of the same material, to be disposed of according to the local
regulations in force.
ALWAYS RESPECT THE REGULATIONS IN FORCE FOR DISPOSING OF OLD OIL AND OTHER POLLUTING MATERIALS
SUCH AS SOUND-PROFING, INSULATING FOAM, ETC.
7
2
3
PART “B”
THIS PART “B” OF THE INSTRUCTIONS MANUAL IS RESERVED FOR PROFESSIONALLY SKILLED PERSONNEL
APPROVED THE MANUFACTURER
Every 50 working hours Drain condensate from the oil tank
Check the oil level
Clean the filter of the automatic condensate drain (dryer)
Every 500 hours Replace oil (at first 500 hrs)
Replace oil filter (at first 500 hrs)
Tighten the screws fixing the electric cables (at first 500 hrs)
Clean the air inlet filter
Clean the condenser heat exchanger (unit with dryer)
Clean the inlet filtration panels
Every 2000 hours Replace the inlet air filter
Replace the oil
Replace the oil filter
Retighten all power cable connections
Safety temperature test
Maintenance kit of the automatic condensate drain (dryer)
Every 4000 hours Clean the finned surface of the air-oil cooler
Replace the oil separator filter
Every 8000 hours Intake valve service kit
Check status of oil return valve and oil pipes
MPV Service kit
Every 24000 hours Air-end overhaul kit
N.B.: THE OPERATIONS MARKED ARE DESCRIBED IN PART "A" OF THIS MANUAL ON CHAPTER 15.2