Está en la página 1de 1

. 6 5 4 . . 6 5 4 .

PERNO_TIPO_U
N LISTA DE ELEMENTOS
10°
(PARA ESTRUCTURA A ARMAR EN SITIO (SGO)
VER PLANO: MS-534-2220-YDA-002-PL-MD-117) (PARA ESTRUCTURA A ARMAR EN SITIO (SGO)
5to Nivel PUNTO DE IZAJE VER PLANO: MS-534-2220-YDA-002-PL-MD-117) PUNTO DE IZAJE Cantidad Peso Peso Observaciones
(T.A. COL) Item Marca Descripcion Total Unit. Total
DETALLE G 1 CN061 CONECTOR 8 29 232.6 ARMADO EN REINIKE
(DETALLE TIPICO PARA CN062 CONECTOR 33 132.0 ARMADO EN REINIKE
CAÑERIAS DE 2") 2 4
4to Nivel PERNO_TIPO_U DIAGONAL
CANTIDAD 4 3 DA030 2 8 16.0 ARMADO EN REINIKE
(T.A. COL) DET. 13
A CAÑERIA 1/2" 4 DA031 DIAGONAL 1 8 7.7 ARMADO EN REINIKE
DET. B PUNTO DE IZAJE
DET. E 5 DA032 DIAGONAL 1 6 6.5 ARMADO EN REINIKE
D D 3er Nivel
(T.A.)
ER053
(Sim.)
SP266
222 Ajustar soporte
6 DA033 DIAGONAL 4 50 200.1 ARMADO EN REINIKE
SP102 en taller
7 DA034 DIAGONAL 4 91 363.9 ARMADO EN REINIKE
8 ER053 ENREJADO 1 11249 11248.7 ARMADO EN REINIKE
SP266
3200

DET. 13 SP265 9 SP102 SOPORTE 1 3 2.6 ARMADO EN REINIKE


2do Nivel
PUNTO DE IZAJE DET. A 10 SP262 SOPORTE 1 52 51.9 ARMADO EN REINIKE
(T.A.) 975 Soldar antes de 11 SP263 SOPORTE 2 6 11.2 ARMADO EN REINIKE
6 instalar cañerías SOPORTE
12 SP264 1 8 8.3 ARMADO EN REINIKE
13 SP265 SOPORTE 5 1 6.5 ARMADO EN REINIKE
DET. B DETALLE H

869
14 SP266 SOPORTE 16 2 28.0 ARMADO EN REINIKE
B (Sim.) (DETALLE TIPICO PARA
CAÑERIAS DE 8") 15 SP267 SOPORTE 3 9 27.7 ARMADO EN REINIKE
16 SP481 SOPORTE 1 13 13.0 ARMADO EN REINIKE

1026
2000 3000 3000 3000 3000 2000 1er Nivel
(T.A.)
DET. G 17 SP482 SOPORTE 1 13 13.0 ARMADO EN REINIKE
16000 18 VI066 VIGA 1 103 103.2 ARMADO EN REINIKE

DET. G
Q19 VI067
VI068
VIGA
VIGA
1
1
103
80
103.2
79.9
ARMADO EN REINIKE
ARMADO EN REINIKE
20
C-C 924
PL18X165 21 VI071 VIGA 1 91 90.7 ARMADO EN REINIKE
2000 3000 3000 3000 3000 2000
PLANTA EL. +1685.605 (T.A.) (3er Nivel) PESO TOTAL ESTRUCTURA MODULO: 12746.7 Kg.
16000

150
PERNO_TIPO_U
CANTIDAD 2
(PARA ESTRUCTURA A ARMAR EN SITIO (SGO)

150
. 6 5 VER PLANO: MS-534-2220-YDA-002-PL-MD-117) 4 . CAÑERIA 1/2"
NOTAS DE PESOS RELACIONADOS:
N PERNO_TIPO_U
D-D 1 Perf´s Ø 45 2MK2220219M- PESO ESTRUCTURA EN REINIKE: 12746.7 Kg.
10°
CANTIDAD 3 DET. 9 Q 2220YDA002STOJ001 PESO PIPING EN REINIKE: 10749.0 Kg.
CAÑERIA 1/2" (Sim.) PL18X165 PESO BANDEJAS ELÉCTRICAS EN REINIKE : NO APLICA Kg.
PERNO_TIPO_U B A
DETALLE 13 Q-Q PESO TOTAL DEL MÓDULO EN REINIKE: 23495.7 Kg.
PERNO_TIPO_U
CANTIDAD 1
B A
PERNO_TIPO_U CANTIDAD 4 PARA INSTALACIÓN DE B A 10 Desde el eje
CANTIDAD 4 CAÑERIA 1/2" CAÑERIA 1/2" 960 DET. 9 PARA INSTALACIÓN DE
SOPORTES VER PLANO
SOPORTES VER PLANO
MS-534-2220-YDA-002-PL-MD-117 PARA INSTALACIÓN DE
CAÑERIA 1/2" CN062 CN061 CN062 MS-534-2220-YDA-002-PL-MD-117 SOPORTES VER PLANO 6 BOLT_1"DIA_A325_21/2"
5to Nivel 5 BOLT_1"DIA_A325_21/2"
A 4to Nivel (VER PLANO: MS-534-2220-YDA-002-PL-MD-117 SP266
(VER PLANO: (T.A. COL) MS-534-2220-YDA-002-PL-MD-117)
DA033 CN061 CN061 (T.A. COL) MS-534-2220-YDA-002-PL-MD-117) 4to Nivel (VER PLANO:

890
SP266 (T.A. COL) MS-534-2220-YDA-002-PL-MD-117)
SP266
CN061 M M (CTRD)
2MK2220219M-
SP266
(CTRD) 2220YDA002STOJ001 DET. 7
(CTRD) DET. 3 SP266 SP266 SP266 SP262 DET. 3 DET. 7 (Opto.) SP266 6 BOLT_1"DIA_A325_21/2"
3200

(CTRD) DA033
(CTRD) (CTRD) DA034 SP266 (Opto.) (VER NOTA 1 DET. 8
SP266
(CTRD) 3er Nivel 3er Nivel (VER NOTA 1 10 Desde el eje
SP264
SP266 DA033 (T.A.) (T.A.) 3er Nivel DET. 8
SP266 (CTRD) SP266 SP266
SP266 SP266 (T.A.) (Opto.) 5 BOLT_1"DIA_A325_21/2"
DA034 DA034 (CTRD) 6 BOLT_1"DIA_A325_21/2"
DA034
DA033 CN061
VI067
VI066
DET. G DET. B SP266 2MK2220219M- DETALLE 1 DETALLE 2 DETALLE 3

1500

1500
SP267 1 2220YDA002STOJ001 AJUSTAR EN TALLER
B (CTRD) DET. B SP266 DET. B

1500
SP267 890 (APERNAR DIAGONALES DESPUÉS DE (APERNAR DIAGONALES DESPUÉS DE
CN062 CN061 CN061 CN061 CN062 2do Nivel 2do Nivel SP266 INSTALAR CAÑERÍAS DEL 1ER NIVEL)
DET. 2 (T.A.) (T.A.) DET. 4 2do Nivel DET. B INSTALAR CAÑERÍAS DEL 1ER NIVEL)
DET. 1 (Tip.) (Opto.) (T.A.) SP266 DET. E PARA SOLDAR VIGAS

3395

3395
2000 3000 3000 3000 3000 2000 PARA SOLDAR VIGAS
VER PLANO ER053 VER PLANO ER053

3395
SP481
2 BOLT_3/4"DIA_A325_13/4"
16000 SP266 SP266 DET. 4 VI066
DET. 5 DET. B

1895

1895
DET. B DET. 5 DET. 5

1895
B-B 1er Nivel 1er Nivel
VI071
(Sim Opto.) SP263 (Opto.)
PLANTA EL. +1684.105 (T.A.) (2do Nivel) (T.A.) (T.A.) 1er Nivel SP265
(T.A.) 4 BOLT_1"DIA_A325_21/4"
DETALLE 6
DET. 5 DET. C SP267
DETALLE 4 DETALLE 5 (SOLDAR DESPUÉS DE
INSTALAR CAÑERÍAS
. 6 5 4 . 3200 (Sim.) DET. 11 DET. D DET. A (SOLDAR DESPUÉS DE (APERNAR DESPUÉS DE DEL 1ER NIVEL)
N 3200
3200
INSTALAR CAÑERÍAS
DEL 1ER NIVEL)
INSTALAR CAÑERÍAS
10°
DEL 1ER NIVEL)
(PARA ESTRUCTURA A ARMAR EN SITIO (SGO)
VER PLANO: MS-534-2220-YDA-002-PL-MD-117)
E-E F-F G-G
PARA SOLDAR VIGAS
VER PLANO ER053
PARA SOLDAR VIGAS
VER PLANO ER053
N N
B A
B A B A PARA INSTALACIÓN DE
DETALLE 9
PARA INSTALACIÓN DE SOPORTES VER PLANO (APERNAR DESPUÉS DE
PARA INSTALACIÓN DE MS-534-2220-YDA-002-PL-MD-117 INSTALAR CAÑERÍAS
SOPORTES VER PLANO SOPORTES VER PLANO
A MS-534-2220-YDA-002-PL-MD-117 MS-534-2220-YDA-002-PL-MD-117 DEL 1ER NIVEL)
SP102 5to Nivel (VER PLANO:
(CTRD) SP267 4to Nivel (VER PLANO: 4to Nivel (VER PLANO: MS-534-2220-YDA-002-PL-MD-117)
(CTRD) (T.A. COL) MS-534-2220-YDA-002-PL-MD-117) (T.A. COL) MS-534-2220-YDA-002-PL-MD-117)
(T.A. COL)
DETALLE 7 DETALLE 8
(SOLDAR DESPUÉS DE (SOLDAR DESPUÉS DE
SP265 INSTALAR CAÑERÍAS INSTALAR CAÑERÍAS
SP265 (CTRD) DET. 8 DEL 2DO NIVEL) DEL 2DO NIVEL)
4 BOLT_1"DIA_A325_21/4"
DET. 8
3200

SP267 (CTRD) DET. 8 (Sim.) DET. 7 DET. 7


(CTRD) DET. 8 (Sim Opto.) DET. 5 (Sim Opto.) (Sim.) 4 BOLT_3/4"DIA_A325_2" P P N-N
(Sim.) (Sim Opto.)
SP263 SP265 3er Nivel (VER NOTA 1) 3er Nivel (Sim.) (VER NOTA 1) 3er Nivel 4 BOLT_7/8"DIA_A325_21/4"
(T.A.) (VER NOTA 1)
SP263
(CTRD) (CTRD) (T.A.) (T.A.) O
(CTRD) DETALLE 11
2MK2220219M- (APERNAR DESPUÉS DE
B
DET. B
2MK2220219M- DET. 4 INSTALAR CAÑERÍAS
1500

1500
2220YDA002STOJ001

1500
SP266 2220YDA002STOJ001
2000 3000 3000 3000 3000 2000
2do Nivel DET. B 2do Nivel VI067 DET. E 2do Nivel
(Sim.) SP264
DET. 4
DEL 1ER NIVEL)
P-P
(T.A.) (T.A.) SP266
(T.A.) DET. F
16000
(Sim Opto.)
O O-O
VER NOTA 1
3395

3395

3395
DET. 6
SP266 SP266 DET. 5 DET. B SP266 DETALLE 10 E
A-A DET. 6 DET. E (Sim Opto.) (APERNAR DESPUÉS DE RT
1895

1895
DET. B O

1895
PLANTA EL. +1682.210 (T.A.) (1er Nivel) (Opto.) DET. A SP267
INSTALAR CAÑERÍAS
N
N
CIÓ
DET. B DEL 1ER NIVEL)
1er Nivel DET. A SP265 1er Nivel 1er Nivel C
(T.A.) RE
(T.A.) (T.A.)
DI
. 6 5 4 .
3200 DET. H 3200 DET. 9 4 SP265
G F SP102
3200 DET. C
J I H E I-I
SP262
K (PARA ESTRUCTURA A ARMAR EN SITIO (SGO) J-J
5to Nivel PUNTO DE IZAJE
H-H 4 VER NOTA 2

(Alto de Estructura)
VER PLANO: MS-534-2220-YDA-002-PL-MD-117)
(T.A. COL)
PUNTO DE IZAJE
DET. 10 1051 2025
DET. 12
B A PERNO_TIPO_U (Opto.) DA032 3 BOLT_3/4"DIA_A325_2" r a)

3976
CANTIDAD 2 1025 1000 ctu
4to Nivel CAÑERIA 1/2" DET. 12 str u
PARA INSTALACIÓN DE DET. 12 PERNO_TIPO_U
(Opto.) d e E 7 NOTA 1:
(T.A. COL) SOPORTES VER PLANO CANTIDAD 1 rgo 1632 - CARGA DE DISEÑO DE OREJA DE IZAJE
MS-534-2220-YDA-002-PL-MD-117 (Sim.) CAÑERIA 1/2" ( La
4to Nivel (VER PLANO: M-M DETALLE 12
IGUAL A 13.5 T.
- ÁNGULO DE IZAJE IGUAL A 0° RESPECTO
3er Nivel ER053 DET. 13 A LA VERTICAL.
C C (T.A. COL) MS-534-2220-YDA-002-PL-MD-117) 359 Ajustar soporte

890
975
(T.A.) PUNTO DE IZAJE NOTA 2:
DA030 en taller Soldar antes de (An - PUNTOS DE APOYO PARA TRANSPORTE.
ch - APOYO EN VIGAS TRANSVERSALES
instalar cañerías od
(PARA INSTALAR PIPING VER PLANO:
DET. 12 6
483 Ajustar soporte
eE EXISTENTES.
DET. 13 975
MS-534-2220-YDA-002-PL-MD-123) (Sim Opto.) 2 35 struc
1250

3200
85
2do Nivel
PUNTO DE IZAJE
DA031 en taller
SP263
t ur
a) ISOMETRICO 221012FPR
Soldar antes de
(T.A.) 3er Nivel
(T.A.)
(VER NOTA 1)
DET. 12 SP264 6 instalar cañerías ARMADO EN REINIKE
(Sim Opto.) VI071
PERNO_TIPO_U
B B DETALLE F
975

DA030
869

VI068 2 ACTUALIZA COTA EN ISOMETRICO 12/14/2018 R.S.F 328


DET. A DET. B DET. E (DETALLE TIPICO PARA
1500

CAÑERIAS DE 14") 1 ACTUALIZA MARCAS, PESO Y AGREGA INFORMACIÓN 12/10/2018 R.S.F 317

L L 2do Nivel DET. B DETALLE D DETALLE E 0 APROBADO PARA CONSTRUCCION 11/26/2018 R.S.F 235
1er Nivel (T.A.) SP266
DET. 12 SP265 DET. 10
SP265 (Sim.) (DETALLE TIPICO PARA (DETALLE TIPICO PARA B EMITIDO PARA APROBACION DE CLIENTE 10/26/2018 R.S.F 135
(T.A.) CAÑERIAS DE 30") CAÑERIAS DE 1/2")
L-L
3395

410 Ajustar soporte 3 3 Rev. DESCRIPCION FECHA APROBÓ TTX.


SP267
A A SP266
SP266
Ajustar soporte 118 en taller
R
NOTAS
1.- DIMENSIONES EN MM. Y ELEVACIONES EN MTS.
1895

2000 3000 3000 3000 3000 2000 64 Ajustar soporte SP267 Soldar antes de SP267 2.- PERNOS CALIDAD A325, GOLILLA F436 Y
en taller
DET. B en taller 6 instalar cañerías SP482
TUERCAS A563 GR DH S.I.C.
3.- ELEMENTOS SOLDADOS EN TERRENO DEBEN Soluciones en Acero
1er Nivel SP266 SER PINTADOS SEGÚN EE. TT.
SP263 SP265 Soldar antes de 4.- ESTOS SON PLANOS DE ARMADO DE
16000 (T.A.) instalar cañerías MÓDULOS DE TRANSPORTE: PROYECTO: SPENCE GROWTH OPTION
6
SP481 R DESDE REINIKE SANTIAGO A SGO.
5.- PARA MONTAJE EN SGO VER PLANOS CONTENIDO: PLANO MODULARIZACION ESTRUCTURA - MODULO 221012FPR
K J I H G F E 6
Soldar antes de
instalar cañerías DETALLE B DETALLE C
SP481
240 240
INDICADOS EN NOTAS DE PLANOS.
COMPLEMENTARIOS.
2MK2220219M-2220YDA002MO02000
6.- PARA ARMADO EN REINIKE SANTIAGO DE ESTRUCTURA 2220-YDA-002 / CWP 2220-21-9M
DET. D 3200 (DETALLE TIPICO PARA (DETALLE TIPICO PARA DETALLE G PIPING Y BANDEJAS ELÉCTRICAS VER PLANOS
INDICADOS EN NOTAS DE PLANOS FECHA : 12/14/2018 DETALLADO POR: MACROSTEEL
DETALLE A CAÑERIAS DE 4") CAÑERIAS DE 16") (DETALLE TIPICO PARA COMPLEMENTARIOS.
Tekla structures

MARCA: 2MK2220219M-2220YDA002MO02000 (DETALLE TIPICO PARA CAÑERIAS DE 16") R-R 7.- PARA ARMADO DE MÓDULO EN SGO VER PLANOS
INDICADOS EN NOTAS DE PLANOS
ESCALAS: S/E No. PLANO

MS-534-2220-YDA-002-PL-MD-111
REV.

ELEVACIÓN EJE B - MODULO 221012FPR - ARMADO EN REINIKE K-K CAÑERIAS DE 2") NOTA: ESTE PLANO SE COMPLEMENTA CON:
2.- PLANO DE MODULARIZACIÓN ESTRUCTURA EN SGO: MS-534-2220-YDA-002-PL-MD-117.
COMPLEMENNTARIOS. TAM: 841x594
O.T. MacroSteel: 534 4-V2-2220-ST-DWG-181111
2
3.- PLANO DE MODULARIZACIÓN PIPING: MS-534-2220-YDA-002-PL-MD-123.
4.- PLANO ELÉCTRICO: 4-V2-2220-EL-DWG-023001.