Está en la página 1de 1

3

D of
HA555 EA-383184 P 3-1313003.03 4400004656 3 4 5 6 7
03 NOTES
REV. NO. SHEET NO. DRAWING NUMBER PLANT NO. INDEX JOB ORDER NO. CONTRACT NO.

OW NER.
1 2

SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION

TS
OF I
FUSE / LINK SWITCHING DEVICE WITH MANUAL OPERATION

CONSENT
A A
ELEMENT WITH STATIC NEGATED OUTPUT RESISTOR AND WITH AUTOMATIC RESET BELL, BUZZER

FUSE WITH THE SUPPLY SIDE INDICATED

VARIABLE RESISTOR SWITCHING DEVICE WITH MANUAL OPERATION

TTEN
AND WITH NON-AUTOMATIC RESET SIREN , HORN
ELEMENT WITH DYNAMIC INPUT

THE W RI
CURRENT TRANSFORMER
RESISTOR WITH PRESET ADJUSTMENT
- SINGLE LINE DIAGRAM

CHANGE-OVER SWITCHING DEVICE WITH MANUAL


ELEMENT WITH DYNAMIC NEGATED INPUT CONTROL AUTOMATIC RESET FROM POSITION 1-2 TERMINAL BLOCK FOR CT CIRCUIT
TO THE NEUTRAL POSITION LEGEND
CAPACITOR

THOUT
CURRENT TRANSFORMER

WI
SEMICONDUCTOR DIODE USED AS A
- TRIPOLAR DRAWING ELEMENT WITH INHIBITING INPUT CAPACITIVE DEVICE TERMINAL BLOCK - KNIFE TYPE

DOCUMENT
RELAY COIL

B OPEN CONTACT, MAKE CONTACT B


ELEMENT WITH NEGATED INHIBITING INPUT
TERMINAL BLOCK - STANDARD
VOLTAGE TRANSFORMER

S
THI
- SINGLE LINE DIAGRAM SLOW OPERATING RELAY COIL

CLOSED CONTACT, BREAK CONTACT

FROM
ELEMENT WITH INPUT WHICH DOES NOT CARRY
ANY LOGIC INFORMATION
POWER SOCKET
WINDING
SLOW RELEASING RELAY COIL

NED
CHANGE-OVER CONTACT, BREAK

SHALL BE OBTAI
X ELEMENT WITH POSTPONED OUTPUT
BEFORE MAKE

VOLTAGE TRANSFORMER
RELAY WITH MAKE CONTACT VT TEST SWITCH
- TRIPOLAR DRAWING

MAKE CONTACT WHICH IS EARLY WHEN


& AND-ELEMENT WITH TWO INPUTS OPERATING AND LATE WHEN RELEASING

PART
VOLTMETER
BREAK CONTACT WHICH IS LATE WHEN CONTROL TEST SWITCH
RELAY WITH CHANGE-OVER CONTACT
>1 OPERATING AND EARLY WHEN RELEASING
OR-ELEMENT WITH TWO INPUTS

N
I
C C
A

FULL OR
AMMETER

SWITCHING DEVICE WITH MANUAL CONTROL


>2 CT TEST SWITCH

LOGIC THRESHOLD ELEMENT WITH FOUR RELAY WITH MAKE CONTACT,

N
W WATTMETER

I
INPUTS AND THRESHOLD VALUE 2 DELAYED WHEN OPERATING
MAKE CONTACT DELAYED WHEN OPERATING

ON
REPRODUCTI
REFERENCE DRAWINGS
Var VARMETER BREAK CONTACT DELAYED WHEN RELEASING
DRAWING TITLE DRAWING NO.
=2
"2 AND ONLY 2" RELAY WITH MAKE CONTACT, DRAWING CONTROL SHEET EE-383111
ELEMENT WITH THREE INPUTS FOR DELAYED WHEN RELEASING
RELAY & METERING ONE LINE DIAGRAM EA-382856
MAKE CONTACT DELAYED WHEN OPERATING

NO
PF POWER FACTOR METER AND RELEASING

d SA
=1

onalGri
D D
EXCLUSIVE OR-ELEMENT WITH THREE INPUTS

POSITION INDICATOR MAIN CONTACT OF A SWITCH DISCONNECTOR RELAY WITH MAKE CONTACT, DELAYED
WHEN OPERATING AND RELEASING

OF Nati
MAIN CONTACT OF A DISCONNECTOR
=
SYNCHROSCOPE LOGIC IDENTITY ELEMENT WITH THREE INPUTS

ARE THE SOLE PROPERTY


MAIN CONTACT OF A CIRCUIT BREAKER
RELAY WITH TWO MAKE CONTACTS, ONE OF
THEM DELAYED WHEN OPERATING
PASSING MAKE CONTACT CLOSING
V RECORDING VOLTMETER
MOMENTARILY DURING OPERATION
>n/2 AND RELEASE
MAJORITY ELEMENT WITH THREE INPUTS

W RECORDING WATTMETER BREAK CONTACT DELAYED WHEN OPERATING

RELAY WITH TWO ACTUATORS AND A TWO


AS-BUILT BY DATE
STABLE POSITIONS
1 NEGATOR
D 2017-01-03 AES REVISED AS PER CONSULTANT COMMENTS KAM AS AS

N
HEREI
MAKE CONTACT DELAYED WHEN RELEASING

E E C 2016-11-24 AES AS MANUFACTURED KAM AS AS


h HOUR METER

B 2016-01-07 AES AS PER CUSTOMER REQUIREMENTS KAM AS AS


&

NED
NAND ELEMENT WITH TWO INPUTS
TWO MECHANICAL LINKS CROSSING
A 2015-10-12 AES ISSUED FOR DETAILED DESIGN KAM AS AS

CONTAI
WITHOUT CONNECTION
REV. DATE BY CHKD. CERT. APPD.
DESCRIPTION
NO.
Wh WATT-HOUR METER
DRAWING COMPLETION CERTIFICATE (DCC):
>1 NOR ELEMENT WITH TWO INPUTS

ON
JUNCTION OF MECHANICAL LINKS

NFORMATI
WATT-HOUR METER FOR ENERGY FROM

Wh A BUSBAR SYSTEM X
BISTABLE ELEMENT AUTOMATIC RESET

THE I
SIGNALLING LAMP
DINAKAR KAMAL NONE
Y DRAWN BY CHECKED BY SCALE:

2015-10-12
DATE STARTED DATE COMPLETED

AND
ELEMENT WITH STATIC INPUT OPR'G. DEPT. ENG. DEPT.
FRAME CONNECTION NON-AUTOMATIC RESET
F
ELECTRO-MECHANICAL POSITION INDICATOR
POSITION F THIS DRAWING IS NOT TO BE USED FOR CERTIFIED

NG
WITH ONE DE-ENERGIZED AND TWO OPERATED CONSTRUCTION OR FOR ORDERING

DRAW I
MATERIAL UNTIL CERTIFIED AND DATED BY DATE

EARTH CONNECTION
ELEMENT WITH STATIC NEGATED INPUT GRAPHICAL SYMBOLS FOR DIAGRAMS +UVLS.2
13.8kV U/V LOAD SHEDDING PANEL-2

S
THI
AL-UQAIR 115/13.8kV SUBSTATION-A
MANUFACTURER/VENDOR NAME
AL-UQAIR SAUDI ARABIA
ALFANAR ELECTRICAL SYSTEMS CONTRACT NO. JOB ORDER NO. INDEX PLANT NO. DRAWING NUMBER SHEET NO. REV. NO.
DRAWING NO. SHEET NO. REV. NO.
03
EA-383184 03 of 3 D 1 2 3 4 5 6 7
4400004656 3-1313003.03 P HA555 EA-383184 of
3 D