AÑO ENE FEB MAR ABR MAY JUN JUL AGO SEP OCT NOV
2008 69.0 82.0 204.0 120.0 0.0 0.0 0.0 42.0 4.0 40.0 141.0
2009 207.0 180.0 311.0 203.0 1.0 0.0 5.0 2.0 2.0 104.0 70.0
2010 12.0 260.0 12.0 287.0 234.0 0.0 0.0 0.0 86.0 0.0 81.0
2011 72.0 36.0 170.0 642.0 7.0 0.0 0.0 0.0 8.0 30.0 63.0
2012 111.0 221.0 303.0 264.0 45.0 27.0 0.0 0.0 54.0 91.0 107.0
2013 144.0 277.0 444.0 60.0 147.0 0.0 0.0 0.0 0.0 176.0 12.0
2014 72.0 68.0 367.0 405.0 117.0 1.0 0.0 8.0 101.0 61.0 66.0
2015 355.0 272.0 217.0 170.0 46.0 27.0 5.0 0.0 14.0 85.0 121.0
2016 114.0 241.0 256.0 45.0 0.0 2.0 **** **** **** **** ****
SUMA 1156.0 1637.0 2284.0 2196.0 597.0 57.0 10.0 52.0 269.0 587.0 661.0
MEDIA 128.4 181.9 253.8 244.0 66.3 6.3 1.3 6.5 33.6 73.4 82.6
AÑO ENE FEB MAR ABR MAY JUN JUL AGO SEP OCT NOV
2008 12.0 16.0 28.0 14.0 0.0 0.0 0.0 18.0 3.0 13.0 38.0
2009 38.0 20.0 69.0 29.0 1.0 0.0 4.0 1.0 2.0 18.0 24.0
2010 3.0 56.0 3.0 36.0 37.0 0.0 0.0 0.0 40.0 0.0 23.0
2011 27.0 13.0 32.0 70.0 7.0 0.0 0.0 0.0 4.0 24.0 23.0
2012 28.0 67.0 40.0 53.0 14.0 14.0 0.0 0.0 30.0 16.0 24.0
2013 30.0 41.0 70.0 28.0 38.0 0.0 0.0 0.0 0.0 45.0 12.0
2014 22.0 29.0 65.0 72.0 45.0 1.0 0.0 8.0 43.0 32.0 24.0
2015 73.0 55.0 36.0 34.0 18.0 27.0 4.0 0.0 14.0 28.0 17.0
2016 33.0 76.0 69.0 17.0 0.0 2.0 **** **** **** **** ****
MAX 73.0 76.0 70.0 72.0 45.0 27.0 4.0 18.0 43.0 45.0 38.0
Precipitación Máxima en 24 horas
En base a registros de precipitaciones máximas diarias para el periodo 2008 - 2016 de la Estación de VIRGEN DE LA PUERTA - OTUZCO, se observa que el evento mayor valor
120.00 mm, ocurrido en ABRIL 2014.
Periodo de Retorno
Periodo de retorno de: 50 Años
P = 1 - 1/50
P= 0.98
Riesgo de Falla
R=
R= 33%
𝐏 =𝟏 − 𝟏/𝐓_𝐫
Donde:
P = Probabilidad de que un evento, ocurra por lo menos una Vez en años
Tr = Período de Retorno
R = Riesgo permisible que el suceso ocurra en cualquier período
1 − del ministerio Transporte)
n = Vida útil de la estructura (considerando 20 años, normas
〖 0.98 〗 ^
Limites de 𝐑 =𝟏 − (Show,
confianza 𝐏^� V.T., Et al.1994) 20
A cada nivel de confianza β corresponde un nivel de significancia α, dado por:
0.9
Para β = 90%
α=
α= 5%
7º 54' 10"
78º 34' 20"
2641 m/s/n/m
DIC ANUAL
13.0 715.0
41.0 1126.0
44.0 1016.0
129.0 1157.0
59.0 1282.0
0.0 1260.0
138.0 1404.0
247.0 1559.0
**** ****
671.0 9519.0
83.9 1189.9
DIC ANUAL
10.0 38.0
18.0 69.0
16.0 56.0
31.0 70.0
30.0 67.0
0.0 70.0
34.0 72.0
58.0 73.0
**** 76.0
58.0 76.0
que el evento mayor valor fue de
HIDROLOGÍA
MEMORIA DE CALCULO
En este acápite se determinan los caudales de las cuencas y subcuencas por el método racional.
Debido a la falta de pluviógrafos en las estaciones próximas al sitio de proyecto, que permitan una determinació
las curvas de intensidad - duración - frecuencia, se trabajó sobre la base de registros de máximas precipitacion
La precipitación máxima probable es aquella magnitud de lluvia que ocurre sobre una cuenca particular, en la c
un gasto de avenida, para el que virtualmente no existe riesgo de ser excedido.
Los diversos procedimientos de estimación de la precipitación máxima probable no están normalizados, ya que
principalmente con la cantidad y calidad de los datos disponibles; además, cambian con el tamaño de la cuenca
emplazamiento y su topografía, con los tipos de temporales que producen las precipitaciones extremas y con e
métodos de estimación de fácil y rápida aplicación son los empíricos y el estadístico.
Aunque existe un número importante de distribuciones de probabilidad empleadas en hidrología, son sólo unas
comunmente utilizadas, debido a que los datos hidrológicos de diversos tipos han probado en repetidas ocasion
satisfactoriamente a un cierto modelo teórico. Las lluvias máximas horarias o diarias por lo común se ajustan bi
distribución de valores extremos tipo I o Gumbel, a la Log-Pearson tipo III y a la gamma incompleta. En este pr
empleó la distribución Gumbel.
x
x i
65.67 mm
n
Estimador de la desviacion estandar
x x
2
i
i 1
S 11.78 mm
n 1
6
*s 9.18 mm
u x 0.5772 * 60.37 mm
Según el estudio de miles de estaciones - año de datos de lluvia, realizado por L. L. Welss, los resultados de un análisis p
llevado a cabo con lluvias máximas anuales tomadas en un único y fijo intervalo de observación, al ser incrementados en
conducían a magnitudes más aproximadas a las obtenidas en el análisis basado en lluvias máximas verdaderas. Por tanto
representativo adoptado para la cuenca será multiplicado por 1.13 para ajustarlo por intervalo fijo y único de observación.
Cálculo de las láminas para distintas frecuencias
Fuente: Elaboración propia
MA PROBABLE
agnitud de lluvia que ocurre sobre una cuenca particular, en la cual generará
no existe riesgo de ser excedido.
(𝑋_𝑖−𝑋 ̅ )^2
1
0.30
Duración
24 hr
18 hr
12 hr
8 hr
6 hr
5 hr
4 hr
3 hr
2 hr
1 hr
2
0.39
X24
X18 = 91%
X12 = 80%
X8 = 68%
X6 = 61%
X5 = 57%
X4 = 52%
X3 = 46%
X2 = 39%
X1 = 30%
3
0.46
2 años
72.0168
65.5353
57.6134
48.9714
43.9302
41.0496
37.4487
33.1277
28.0865
21.6050
56.9702
51.1056
47.7544
43.5654
38.5387
32.6741
25.1339
Duraciones, en horas
5
0.57
62.2661
55.8563
52.1936
47.6152
42.1212
35.7114
27.4703
I
6
0.61
68.9574
61.8589
57.8025
52.7321
46.6477
39.5491
30.4224
P mm
t duración hr.
8
d c
0.68
Tiempo de Cociente
73.9215
66.3119
61.9636
56.5282
50.0057
42.3961
32.6124
12
0.80
03.76
Las relaciones o cocientes a la lluvia de 24 horas se emplean para duraciones de varias horas. D. F. Campos A
propone los siguientes cocientes:
Estos datos serán obtenidos como un porcentaje de los resultados de la precipitación máxima probable para 2
para cada período de retorno, diferentes porcentajes de este valor según los tiempos de duración de lluvia ado
92.2813
81.1264
50 años
101.4080 108.7080
98.9243
86.9664
75 años
112.9511
102.7855
90.3609
76.8067
68.9002
64.3821
58.7346
51.9575
44.0509
33.8853
Basándose en los resultados de la anterior tabla, y los tiempos de duración adoptados, calculamos la intensida
Intensidades de lluvia para diferentes tiempos de duración
Fuente: Elaboración propia
en la cual:
I=
t=
T=
Tiempo de duración
Hr
24 hr
18 hr
12 hr
8 hr
6 hr
5 hr
4 hr
3 hr
2 hr
1 hr
a,b,c =
min
1440
1080
720
480
360
300
240
180
120
60
2 años
3.0007
3.6408
4.8011
6.1214
7.3217
8.2099
9.3622
11.0426
14.0433
21.6050
Intensidad (mm/hr)
Duración de la lluvia (min)
Período de retorno (años)
Parámetros de ajuste
De donde:
Nº
1
2
3
4
5
6
7
8
9
10
10
Ln (A) =
x
1440
1080
720
480
360
300
240
180
120
60
4980
5.6068
5 años
3.4908
4.2355
5.5853
7.1213
8.5176
9.5509
10.8914
12.8462
16.3370
25.1339
I
y
3.0007
3.6408
4.8011
6.1214
7.3217
8.2099
9.3622
11.0426
14.0433
21.6050
89.1488
I
3.8153
4.6293
6.1045
7.7833
9.3094
10.4387
11.9038
14.0404
17.8557
27.4703
tc
d a *T b
A=
d
t c
I d * t c
ln x
7.2724
6.9847
6.5793
6.1738
5.8861
5.7038
5.4806
5.1930
4.7875
4.0943
58.1555
272.2613
0.195*mL
25 años
4.2253
5.1267
6.7605
8.6197
10.3098
11.5605
13.1830
15.5492
19.7746
30.4224
c L
Intensidad de la lluvia (mm /hr) según el Periodo de Reto
10 años 50 años
4.5295
5.4958
7.2472
9.2402
11.0520
12.3927
14.1320
16.6686
21.1981
32.6124
La representación matemática de las curvas Intensidad - Duración - Período de retorno, Sg. Bernard es:
a *T b
B=
ln x*ln y
7.9912
9.0258
10.3219
11.1856
11.7183
12.0084
12.2584
12.4722
12.6492
12.5816
112.2127
-0.6164
Nº
1
2
3
4
5
6
7
8
9
10
10
Ln (A) =
Nº
1
2
3
4
5
6
7
8
9
10
10
Ln (A) =
Nº
1
2
3
4
5
6
7
8
9
10
10
Ln (A) =
x
1440
1080
720
480
360
300
240
180
120
60
4980
5.7581
x
1440
1080
720
480
360
300
240
180
120
60
4980
5.8469
x
1440
1080
720
480
360
300
240
180
120
60
4980
5.9490
y
3.4908
4.2355
5.5853
7.1213
8.5176
9.5509
10.8914
12.8462
16.3370
25.1339
103.7099
y
A=
3.8153
4.6293
6.1045
7.7833
9.3094
10.4387
11.9038
14.0404
17.8557
27.4703
113.3507
y
A=
4.2253
5.1267
6.7605
8.6197
10.3098
11.5605
13.1830
15.5492
19.7746
30.4224
125.5318
A=
ln x
7.2724
6.9847
6.5793
6.1738
5.8861
5.7038
5.4806
5.1930
4.7875
4.0943
58.1555
316.7312
ln x
7.2724
6.9847
6.5793
6.1738
5.8861
5.7038
5.4806
5.1930
4.7875
4.0943
58.1555
346.1742
ln x
7.2724
6.9847
6.5793
6.1738
5.8861
5.7038
5.4806
5.1930
4.7875
4.0943
58.1555
383.3754
It0.c193d4*t*
Periodo de retorno para T = 5 años
ln y
1.2501
1.4435
1.7201
1.9631
2.1421
2.2566
2.3880
2.5530
2.7934
3.2242
21.7343
ln y
B=
1.3390
1.5324
1.8090
2.0520
2.2310
2.3455
2.4769
2.6419
2.8823
3.3131
22.6232
ln y
B=
1.4411
1.6345
1.9111
2.1540
2.3331
2.4476
2.5789
2.7440
2.9844
3.4152
23.6439
B=
ln x*ln y
9.0915
10.0825
11.3172
12.1197
12.6088
12.8713
13.0876
13.2579
13.3735
13.2011
121.0112
-0.6164
-0.6164
-0.6164
tcc0.3c0.3815/4
Nº
1
2
3
4
5
6
7
8
9
10
10
Ln (A) =
Nº
1
2
3
4
5
6
7
8
9
10
10
Ln (A) =
Nº
1
2
3
4
5
6
7
8
9
10
10
Ln (A) =
Nº
1
2
3
x
1440
1080
720
480
360
300
240
180
120
60
4980
6.0185
x
1440
1080
720
480
360
300
240
180
120
60
4980
6.0568
x
1440
1080
720
480
360
300
240
180
120
60
4980
6.0831
x
1440
1080
720
y
4.5295
5.4958
7.2472
9.2402
11.0520
12.3927
14.1320
16.6686
21.1981
32.6124
134.5685
y
A=
4.7063
5.7103
7.5301
9.6008
11.4834
12.8764
14.6836
17.3192
22.0255
33.8853
139.8209
y
A=
4.8314
5.8621
7.7303
9.8561
11.7887
13.2188
15.0740
17.7796
22.6111
34.7863
143.5384
y
A=
5.5291
6.7087
8.8466
ln x
7.2724
6.9847
6.5793
6.1738
5.8861
5.7038
5.4806
5.1930
4.7875
4.0943
58.1555
410.9734
ln x
7.2724
6.9847
6.5793
6.1738
5.8861
5.7038
5.4806
5.1930
4.7875
4.0943
58.1555
427.0145
ln x
7.2724
6.9847
6.5793
6.1738
5.8861
5.7038
5.4806
5.1930
4.7875
4.0943
58.1555
438.3677
ln x
7.2724
6.9847
6.5793
t
Periodo de retorno para T = 50 años
ln y
1.5106
1.7040
1.9806
2.2236
2.4026
2.5171
2.6484
2.8135
3.0539
3.4847
24.3391
ln y
1.5489
1.7423
2.0189
2.2619
2.4409
2.5554
2.6867
2.8518
3.0922
3.5230
24.7220
ln y
1.5751
1.7685
2.0451
2.2881
2.4671
2.5816
2.7130
2.8781
3.1184
3.5492
24.9844
1.7100
1.9034
2.1800
B=
B=
B=
ln x*ln y
10.9858
11.9018
13.0310
13.7278
14.1420
14.3570
14.5152
14.6105
14.6206
14.2675
136.1592
-0.6164
-0.6164
-0.6164
Ln (A) =
480
360
300
240
180
120
60
4980
6.2179
11.2794
13.4911
15.1277
17.2509
20.3472
25.8763
39.8097
164.2665
A=
6.1738
5.8861
5.7038
5.4806
5.1930
4.7875
4.0943
58.1555
501.6716
tSH
2.4230
2.6020
2.7165
2.8479
3.0129
3.2533
3.6841
26.3332
B=
14.9590
15.3158
15.4945
15.6081
15.6461
15.5753
15.0840
147.7564
-0.6164
Resumen de aplicación de regresión potencial
Periodo de
Retorno (años)
2
5
10
25
50
75
100
500
Promedio =
1
2
3
4
5
6
7
8
8
Ln (A) =
Término ctte. de
regresión (d)
272.26128170686
316.73120820253
346.17416899864
383.37542801631
410.97344710556
427.01446798591
438.36768675396
501.67159263738
387.07116017589
2
5
10
25
50
75
100
500
767
5.5749
272.2613
316.7312
346.1742
383.3754
410.9734
427.0145
438.3677
501.6716
3096.5693
Donde:
I=
263.7140
t
2.3026
3.2189
3.9120
4.3175
4.6052
6.2146
26.8733
263.7140
* T
5.8469
5.9490
6.0185
6.0568
6.0831
6.2179
47.5371
0.109335
0.61639
Nº x
d a *T b
y ln x
0.6931
1.6094
ln y
5.6068
5.7581
13.4631
19.1491
23.5446
26.1502
28.0135
38.6421
Regresión potencial
ln x*ln y
3.8863
9.2672
162.1162
0.1093
Intensidad - Tiempo de duración - Período de retorno
Fuente: Elaboración propia
Frecuencia
años 35 40 45 50 55
2 31.79 29.28 27.23 25.52 24.06
5 35.14 32.36 30.10 28.21 26.60
10 37.91 34.91 32.47 30.43 28.69
25 41.90 38.59 35.89 33.63 31.71
50 45.20 41.63 38.71 36.28 34.21
75 47.25 43.52 40.47 37.92 35.76
100 48.76 44.91 41.76 39.14 36.90
500 58.14 53.55 49.80 46.67 44.00
INTENSIDAD (mm/h)
225.00
Año 500
200.00
175.00
150.00
125.00
400
100.00
75.00
50.00
25.00
0.00
0 5 10 15 20 25 30 35 40 45 50 55
18
0.91
92.7633
78.8488
70.7320
66.0939
60.2962
53.3389
45.2221
34.7863
24
1.00
38.1156
34.6462
32.5331
30.0374
26.9668
22.9201
16.7637
346.9435
100 años
In t e n s id a d ( m m /h r)
In t e n s id a d ( m m /h r)
30
20
10
30
20
10
0
Regresión T= 2 años
I Vs. t
1000
Duración (min)
Power (I Vs. t)
Regresión T= 5 años
20
10
30
20
10
40
30
20
10
60
50
40
30
20
0
0 200
Regresión T= 5 años
200 400
400
400
600
600
600
800
800
Regresión T= 25 años
800
1000
Duración (min)
I Vs. t
Power (I Vs. t)
Regresión T= 10 años
200 1000
Duración (min)
I Vs. t
Power (I Vs. t)
1000
Duración (min)
I Vs. t
Power (I Vs. t)
Regresión T= 50 años
1200
1200
1400
1400
1400
1
tcc0.30.3815/4
Periodo de retorno para T = 50 años
(lnx)^2
52.8878
48.7863
43.2865
38.1156
34.6462
32.5331
30.0374
26.9668
22.9201
16.7637
346.9435
70
60
60
50
40
30
20
10
60
50
40
30
20
10
0
0
40
30
20
10
0
0
0
200
Regresión T= 50 años
200 400
400
600
600
R² = 0.9994380348
800
800
1000
Duración (min)
I Vs. t
Power (I Vs. t)
Regresión T= 75 años
1000
Duración (min)
I Vs. t
Power (I Vs. t)
1000
Duración (min)
I Vs. t
Power (I Vs. t)
1200
1200
1400
1400
1400
50
40
30 f(x) = 501.6715926374 x^-0.6163860881
20 R² = 0.9994380348
10
0
HS 38.1156
34.6462
32.5331
30.0374
26.9668
22.9201
16.7637
346.9435
In t e n s id a d
70
60
50
40
30
20
10
0
0 200
Regresión T= 500 años
Power (Column E)
1400 1
HS
realiza otra regresión de potencia entre las columnas del periodo de retorno (T) y
ner valores de la ecuación:
Regresión potencial
(lnx)^2
0.4805
2.5903
5.3019
10.3612
15.3039
18.6407
21.2076
38.6214
112.5074
Tabla de intensidad - Tiempo de duración - Periodo de retorno
Duración en minutos
30
34.96
38.64
41.69
46.08
49.71
51.96
53.62
63.94
Tabla de intensidad - Tiempo de duración - Periodo de retorno (continuación...)
60
22.80
25.21
27.19
30.06
32.42
33.89
34.98
41.71
20 25 30 35 40 45 50 55 60
0 . 280049 * PPTR
I TR
Tc 0 .6
Donde:
I TR = Intensidad de Lluvia
PPTR = Precipitación máxima 24 horas para un Tr, mm.
Tc = Tiempo de concentración, horas.
Para el presente caso en que la geomorfología de zona predomina en taludes y cauces con pendientes pronunc
tiempo de concentración ha sido evaluado con formulas aplicables al predominio de flujo, resultando un tiempo d
concentración promedio de 10 minutos (Dato Show, V.T., Maidment, D.R., Mays, 1994, METODO RACIONAL M
pag 538).
�= (𝐶 . 𝐼 .
𝐴)/360
Donde:
Q: Caudal máximo [m3/s]
C: Coeficiente de escorrentía, En base a las características físicas del área drenante se determino que el coeficiente de escu
I : Intensidad de la Lluvia de Diseño, con duración igual al tiempo de concentración de la cuenca y con frecuencia igual al
A: Área de la cuenca. [Ha]
CONCLUSIONES
Se ha considerado en el estudio para cálculo de Caudales, el análisis de Frecuencia de Eventos Hidrológicos Máximos par
La precipitación esperada, para un periodo de retorno de 50 Años, determinado por el método de Log Normal es de 108.71
El caudal unitario de diseño para un periodo de retorno de 50 años, para el diseño de obras de arte de la Trocha Carrozabl
con pendientes pronunciadas, el
o, resultando un tiempo de
METODO RACIONAL MODIFICADO,
rmino que el coeficiente de escurrimiento C = 0.49
cuenca y con frecuencia igual al período de retorno seleccionado para el diseño (Curvas de I-D-F) [mm/h]
0.5
B 2A
C=
A=
2A = 0.50 M
A = 0.25 M A=
B = 0.50 M
2B = 1.00 M
A+2B = 1.25 M
2.25
2312
8
IZQUIERDA +
2304
212
1,450
1.- CUNETA
Diseño de la cuneta lado derecho:
BADEN 1
8% 12.5
0.080 M/M
1
1 8 METROS
12.5 100 METROS
BADEN 2
6% 16.66666667
0.060 M/M
1
1 6 METROS
16.66666667 100 METROS
BADEN 3
6% 16.66666667
0.060 M/M
1
1 6 METROS
16.66666667 100 METROS
BADEN 4
6% 16.66666667
0.060 M/M
1
1 6 METROS
16.66666667 100 METROS
BADEN 5
8% 12.5
0.080 M/M
1
1 8 METROS
12.5 100 METROS
BADEN 6
8% 12.5
0.080 M/M
1
1 8 METROS
12.5 100 METROS
BADEN 7
8% 12.5
0.080 M/M
1
1 8 METROS
12.5 100 METROS
BADEN 8
8% 12.5
0.080 M/M
1
1 8 METROS
12.5 100 METROS
8%
3.75
0.3 8
0.300
3.75 100
0.49
ancho x largo
largo : 5,907 M
ancho : 3.50 M
2.06745 Ha
Area total de cuneta
3
- DERECHA
20
0.32
10
1 16.667 16.696639715
4.9910 5
1 12.500 12.539936204
4.9841 5
3.75
110.4
velocidad
PENDIENTE RUGOSID RUGOSID TIPO DE OBRA DE ARTE OBSERVACION
S (%) n n (corrreg) FLUJO
1.43% 0.027 0.040 Subcrítico Badén Zanjas de coronación
Alcantarilla
3.33% 0.027 0.040 Subcrítico Alcantarilla Revestir con piedra + Zanjas de coronación
0.91% 0.027 0.040 Alcantarilla Zanjas de coronación
Alcantarilla
5.00% 0.027 0.040 Subcrítico Alcantarilla Revestir con piedra + Zanjas de coronación
Alcantarilla
3.33% 0.027 0.040 Subcrítico Alcantarilla Revestir con piedra + Zanjas de coronación
Alcantarilla
Disipador de energía
Disipador de energía
Nuevo analisis alcantarilla
Alcantarilla
Alcantarilla de alivio
Nuevo analisis alcantarilla
Alcantarilla
Alcantarilla de alivio
Alcantarilla de alivio
Alcantarilla de alivio
Nuevo analisis alcantarilla
3.64% 0.027 0.040 Subcrítico Alcantarilla Revestir con piedra + Zanjas de coronación
3.24% 0.027 0.040 Subcrítico Alcantarilla Revestir con piedra + Zanjas de coronación
njas de coronación
njas de coronación
njas de coronación
njas de coronación
njas de coronación
njas de coronación
njas de coronación
njas de coronación
njas de coronación
njas de coronación
njas de coronación
njas de coronación
ALCANTARI CUERVA
# BADEN PLAZOLETA
LLA PELIGROSA
0+000
0+010
0+020
0+030
0+040
0+050
0+060
0+070
0+080
0+090
0+100
0+110
0+120
0+130
0+140
0+150
0+160
0+170
0+180
0+190
0+200
0+210
0+220
0+230
0+240
0+250
0+260
0+270
0+280
0+290
0+300
0+310
0+320
0+330
0+340
0+350
0+360
0+370
0+380
0+390
0+400
0+410
0+420
0+430
0+440
0+450
0+460
0+470
0+480 1 1
0+490
0+500 1
0+510
0+520
0+530
0+540
0+550
0+560
0+570
0+580
0+590
0+600
0+610
0+620
0+630
0+640
0+650
0+660
0+670
0+680
0+690
0+700
0+710
0+720
0+730
0+740
0+750
0+760
0+770
0+780
0+790
0+800
0+810
0+820
0+830
0+840
0+850
0+860
0+870
0+880 1
0+890
0+900
0+910
0+920
0+930
0+940
0+950
0+960
0+970
0+980
0+990
1+000 1
1+010
1+020
1+030
1+040
1+050
1+060
1+070
1+080
1+090
1+100
1+110
1+120
1+130
1+140
1+150
1+160
1+170
1+180
1+190
1+200
1+210
1+220 1
1+230
1+240
1+250
1+260
1+270 1
1+280
1+290
1+300
1+310
1+320
1+330
1+340
1+350
1+360
1+370
1+380
1+390
1+400
1+410
1+420
1+430
1+440
1+450
1+460
1+470
1+480
1+490
1+500 1
1+510
1+520
1+530
1+540
1+550
1+560 1 1
1+570
1+580
1+590
1+600
1+610
1+620 1 1
1+630
1+640
1+650
1+660
1+670
1+680
1+690
1+700
1+710
1+720
1+730
1+740
1+750
1+760
1+770
1+780
1+790
1+800
1+810 1
1+820
1+830
1+840
1+850
1+860 1
1+870
1+880
1+890
1+900
1+910
1+920
1+930
1+940
1+950
1+960
1+970
1+980
1+990
2+000 1
2+010
2+020
2+030
2+040
2+050 1 1
2+060
2+070
2+080
2+090
2+100
2+110
2+120
2+130
2+140
2+150
2+160
2+170
2+180
2+190
2+200 1
2+210
2+220
2+230
2+240
2+250
2+260
2+270
2+280
2+290
2+300
2+310
2+320
2+330
2+340
2+350
2+360
2+370
2+380
2+390
2+400
2+410
2+420
2+430
2+440
2+450
2+460
2+470
2+480
2+490
2+500 1
2+510
2+520
2+530
2+540
2+550
2+560
2+570 1
2+580
2+590
2+600
2+610
2+620
2+630
2+640
2+650
2+660
2+670
2+680
2+690
2+700
2+710
2+720
2+730
2+740
2+750
2+760
2+770
2+780
2+790
2+800
2+810
2+820
2+830
2+840
2+850
2+860
2+870
2+880 1 1
2+890
2+900
2+910
2+920
2+930
2+940
2+950
2+960
2+970
2+980
2+990
3+000 1
3+010 1
3+020
3+030
3+040
3+050
3+060
3+070
3+080
3+090
3+100
3+110
3+120
3+130
3+140
3+150
3+160
3+170
3+180
3+190
3+200
3+210
3+220
3+230
3+240
3+250
3+260
3+270
3+280
3+290
3+300
3+310
3+320
3+330
3+340
3+350
3+360
3+370
3+380
3+390
3+400
3+410
3+420
3+430
3+440 1
3+450
3+460
3+470
3+480
3+490
3+500 1
3+510
3+520
3+530
3+540
3+550 1
3+560
3+570
3+580
3+590
3+600
3+610
3+620
3+630
3+640
3+650
3+660
3+670
3+680
3+690
3+700
3+710
3+720
3+730
3+740
3+750 1
3+760
3+770
3+780
3+790
3+800
3+810
3+820
3+830
3+840
3+850
3+860
3+870 1
3+880
3+890
3+900
3+910
3+920
3+930
3+940
3+950 1
3+960 1
3+970
3+980
3+990
4+000 1
4+010
4+020
4+030
4+040 1
4+050
4+060
4+070
4+080
4+090
4+100
4+110
4+120
4+130
4+140
4+150
4+160
4+170
4+180
4+190 1 1
4+200
4+210
4+220
4+230
4+240
4+250
4+260
4+270
4+280
4+290
4+300
4+310 1
4+320
4+330
4+340
4+350
4+360
4+370
4+380
4+390
4+400
4+410
4+420
4+430
4+440
4+450
4+460
4+470 1
4+480
4+490
4+500 1
4+510
4+520
4+530
4+540
4+550 1
4+560
4+570
4+580
4+590
4+600
4+610
4+620
4+630
4+640
4+650
4+660
4+670
4+680
4+690
4+700
4+710
4+720
4+730
4+740
4+750
4+760
4+770
4+780
4+790
4+800
4+810
4+820
4+830
4+840
4+850
4+860
4+870
4+880 1 1
4+890
4+900
4+910
4+920
4+930
4+940
4+950
4+960
4+970
4+980
4+990
5+000 1
5+010
5+020
5+030
5+040
5+050
5+060 1
5+070
5+080
5+090
5+100
5+110
5+120
5+130
5+140
5+150
5+160
5+170
5+180
5+190
5+200
5+210 1
5+220
5+230
5+240
5+250 1 1
5+260
5+270
5+280
5+290
5+300
5+310
5+320
5+330
5+340
5+350
5+360
5+370
5+380
5+390
5+400
5+410
5+420
5+430
5+440
5+450
5+460
5+470
5+480
5+490
5+500 1
5+510
5+520
5+530
5+540
5+550
5+560
5+570
5+580
5+590
5+600
5+610
5+620
5+630 1
5+640
5+650
5+660
5+670
5+680
5+690
5+700
5+710
5+720
5+730
5+740
5+750
5+760 1
5+770
5+780
5+790
5+800
5+810
5+820
5+830
5+840
5+850
5+860
5+870
5+880
5+890
5+900
5+910