Está en la página 1de 8

CAPACITY DEMAND FACTOR (%) CONSUM

Equipment At Normal Sea At Leaving Port


Out Put Input Total Work Going
(kW) (kW) (set) (set) % C.L I.L % C.L
HULL PART :

Boat Winches 3.70 4.26 2 2 - - - - -


E/H Pump for Cargo Gear 75.00 82.40 3 3 - - - 40 98.88
Cargo Hold Vent. Fan 1.50 1.80 2 2 90 3.24 - 90 3.24
Cargo Hold Vent. Fan 2.20 2.60 4 2 90 4.68 - 90 4.68
Pump Unit Room Vent. Fan 0.40 0.50 2 2 90 0.90 - 90 0.90
Galley Equipment 32.00 32.00 1 1 50 - 16.00 50 -
Laundry Equipment 3.00 3.00 1 1 50 - 1.50 50 -
Provision Ref. Comp. 2.20 2.48 2 1 75 - 1.86 75 -
Unit Cooler 1.50 1.70 3 3 90 4.59 - 90 4.59
Accom. Ladder Winch 1.50 1.80 2 1 - - - - -
Sewage Treat System 2.25 2.55 1 1 80 - 2.04 80 2.04
Steering Gear 3.70 4.60 2 1 50 2.30 - 50 2.30
Ref. Container ( ………. ) 6.50 6.50 4 4 - - - 60 15.60
Accomodation Fan 0.75 0.90 3 3 80 2.16 - 80 2.16
Accomodation Fan 0.40 0.50 3 3 80 1.20 - 80 1.20
Accomodation Fan 1.50 1.80 2 2 80 2.88 - 80 2.88
Accomodation Fan 3.70 4.63 1 1 80 3.70 - 80 3.70
CO2 Bottle Room Fan 0.20 0.25 1 1 80 0.20 - 80 0.20
Miscellaneous 10.00 10.00 1 1 50 - 5.00 50 -
SUBTOTAL 25.85 26.40 142.37

Keterangan : CL : Continous Load


IL : Intermittent Load

Tabel 7
EMAND FACTOR (%) CONSUMPTION (kW)

At Leaving Port At Cargo Handling At in Port

I.L % C.L I.L % C.L I.L

- - - - - - -
- 75 185.40 - - - -
- 90 3.24 - - - -
- 90 4.68 - - - -
- 90 0.90 - - - -
16.00 50 - 16.00 50 - 16.00
1.50 50 - 1.50 50 - 1.50
1.86 75 - 1.86 75 - 1.86
- 90 4.59 - 90 4.59 -
- - - - 70 - 1.26
- 80 - 2.04 80 - 2.04
- - - - - - -
- 60 15.60 - - - -
- 80 2.16 - 80 2.16 -
- 80 1.20 - 80 1.20 -
- 80 2.88 - 80 2.88 -
- 80 3.70 - 80 3.70 -
- 80 0.20 - 80 0.20 -
5.00 50 - 5.00 50 - 5.00
24.36 224.55 26.40 14.73 27.66
CAPACITY DEMAND FACTOR (%) & CONSUMPTION (kW)

At Normal Sea At Leaving Port At Cargo Handling At in Port


Equipment
Out Put Input Total Work Going
(KW) (KW) (set) (set)
% C.L I.L % C.L I.L % C.L I.L % C.L I.L

MACHINERY PART :

M/E Aux. Blower 15.07 17.05 2 1 - - - 60 10.23 - - - - - - -


M/E Turn Gear 0.40 0.48 1 1 - - - - - - 75 - 0.36 75 - 0.36
Main Air Compressor 11.04 13.00 2 1 70 - 9.10 70 9.10 - 70 - 9.10 70 - 9.10
Main Cool. F.W. Pump 3.70 4.30 2 1 75 3.23 - 75 3.23 - - - - - - -
Main Cool. S.W. Pump 11.00 13.00 2 1 80 10.40 - 80 10.40 - - - - - - -
Aux. Cool. S.W. Pump 5.50 6.50 1 1 70 4.55 - 70 4.55 - 70 4.55 - 70 4.55 -
Main L.O. Pump 18.50 20.60 2 1 70 14.42 - 70 14.42 - - - - - -
L.O. Transfer Pump 1.50 1.80 1 1 - - - - - - - - - - - -
Filter L.O. Pump 0.20 0.30 1 1 70 0.21 - 70 0.21 - - - - - - -
F.O. Supply Pump 2.20 2.80 2 1 65 1.82 - 65 1.82 - - - - - - -
F.O. Transfer Pump 1.50 1.80 1 1 70 1.26 70 - 1.26 - - - - - -
F.O. Transfer Pump 1.50 1.80 1 1 - - - - - - - - - - - -
F.W. Pump 5.50 6.50 2 1 75 - 4.88 75 - 4.88 75 - 4.88 75 - 4.88
Sanitary Pump 2.20 2.50 2 1 85 - 2.13 85 - 2.13 85 - 2.13 85 - 2.13
Fire & G.S. Pump 18.50 22.00 1 1 - - - 80 17.60 - - - - - - -
Bilge Pump 1.50 1.80 1 1 - - - - - - - - - - - -
Fire & Ballast Pump 18.50 22.00 1 1 - - - 80 17.60 - 80 17.60 - -
F.O. Purifier 1.50 1.80 1 1 70 1.26 - 70 1.26 - - - - - - -
Sludge Pump 2.20 2.80 1 1 - - - - - - - - - - - -
L.O. Purifier 1.50 1.80 1 1 70 1.26 - 70 1.26 - 70 1.26 - - - -
E/R Vent. Fan 3.70 4.30 2 2 95 8.17 - 95 8.17 - 50 4.3 - 50 4.3 -
Lathe 2.20 2.50 1 1 - - - - - - 50 - 1.25 50 - 1.25
Drill. Mach. 0.40 0.50 1 1 - - - - - - 50 - 0.25 50 - 0.25
Grinder 0.40 0.50 1 1 - - - - - - 50 - 0.25 50 - 0.25
Electric Welder ……. 25.00 25.00 1 1 - - - - - - 40 - 10.00 40 - 10.00
L.O. Purifier Tester 8.00 8.00 1 1 100 - 8.00 100 - 8.00 100 - 8.00 - - -
L.O. Setling Tank Heater 1.00 1.00 1 1 - - - - - - - - - - - -
Waste O. Tank Heater for Incin 3.00 3.00 1 1 - - - - - - - - - - - -
Waste O. Incin 0.40 0.50 1 1 - - - - - - - - - - - -
Eng, C.R. Unit Cooler 2.60 3.31 1 1 75 2.48 - 75 2.48 - 75 2.48 - 75 2.48 -
SUBTOTAL 47.80 25.36 102.33 16.26 30.19 36.21 11.33 28.21

Ket.: C.L. : Continous Load


I.L. : Intermittent Load
CAPACITY DEMAND FACTOR (%) & CONSUMPTION (kW)

Out Put Input Total Work At Normal At Leaving At Cargo At Inport


Equipment
(kW) (kW) (Set) (Set) Sea Going Port Handling

% C.L I.L % C.L I.L % C.L I.L % C.L I.L


ELECTRICAL PART

Acc. Space Light 18.00 18.00 1 1 40 7.20 - 40 7.20 - 40 7.20 - 40 7.20 -


Machinery Space Light 4.00 4.00 1 1 85 3.40 - 85 3.40 - 85 3.40 - 85 3.40 -
Weather Deck Light 6.60 6.60 1 1 - - - 20 1.32 - 90 5.94 - 90 5.94 -
Portable Cargo Light 3.60 3.60 1 1 - - - - - - 80 2.88 - - - -
Nav. and Signal Light 0.30 0.30 1 1 60 0.18 - 60 0.18 - 20 0.06 - 20 0.06 -
Interior Communication 1.50 1.50 1 1 50 0.75 - 50 0.75 - 50 0.75 - 50 0.75 -
Radio Station 2.70 2.70 1 1 60 1.62 - 60 1.62 - 30 0.81 - 30 0.81 -
Nautical Instrument 4.00 4.00 1 1 70 2.80 - 70 2.80 - 70 2.80 - 70 2.80 -
Miscellaneous 4.00 4.00 1 1 50 2.00 - 50 2.00 - 50 2.00 - 50 2.00 -
SUBTOTAL 17.95 0.00 19.27 0.00 25.84 0.00 22.96 0.00
TOTAL 91.60 51.76 263.97 40.62 280.58 62.61 49.02 55.87
Ket.: C.L. : Contiboti Load
I.L. : Intermiltel Load

CL = IL = DEMAND FACTOR (%) x SUM OF WORK EQUIPMENT (SET) x Pin (kW)

DEMAND FACTOR (%) = { P (yang terpakai) : P (yang terpasang) } x 100 %

CL = IL = P (yang terpakai)
SUM OF WORK EQUIPMENT (SET) x Pin (kW) = P (yang terpasang)
ELECTRIC POWER CONSUMPTION TABLE

> Nama Kapal : CARAKA JAYA 2nd PHASE 3650 DWT SEMI CONTAINER

SUMMARY OF GENERATOR LOAD

EQUIPMENT AT NORMAL AT LEAVING AT CARGO


SEA GOING PORT HANDLING

a). INTERMITTENT LOAD


1. Total Load (kW) 51.76 40.62 62.61

2. Diversity Factor 0.50 0.50 0.50

3. Necessary Power (kW) 25.88 20.31 31.31


(a.1 *a.2)

b). CONTINOUS LOAD (Kw) 91.60 263.97 280.58

c). TOTAL LOAD (Kw) 117.48 284.28 311.89


(a.3 + b)

d). GENERATOR IN SERVICE (Kw) 200 400 400


(1 X 200) (2 X 200) (2 X 200)

e). LOAD FACTOR GENERATOR (%) 58.74 71.07 77.97


(c/d *100 %)
CONTAINER

AT IN PORT

55.87

0.50

27.94

49.02

76.96

200
(1 X 200)

38.48
NORMAL SEA GOING LEAVING PORT
GENERATOR
ALTERNATIF IN SERVICE WORK MPL LFG WORK MPL
(KW) (SET) (KW) (%) (SET) (KW)

1 400 1 117.48 29.37

2 200

3 100

4 250
LEAVING PORT CARGO HANDLING IN PORT

LFG WORK MPL LFG WORK MPL LFG


(%) (SET) (KW) (%) (SET) (KW) (%)

También podría gustarte