Está en la página 1de 90

Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

SERVICIO NACIONAL DE METEOROLOGIA E HIDROLOGIA


DIRECCION REGIONAL DE LAMBAYEQUE
ESTACION : CHONTALI LATITUD : 05°38'39 S DEPARTAMENTO: Cajamarca
CODIGO : 000250/ Chontali/ DRE-02 LONGITUD: 79°05'25 W PROVINCIA : Jaén
REGISTRO: Precipitacion(mm) ALTITUD : 1627 msnm DISTRITO :Chontalí

DATOS: PRECIPITACIÓN MAXIMAS EN 24 HORAS

AÑO Ene. Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic TOTAL MAX. ANUALES
1983 37.29 11.77 134.20 80.96 29.26 0.11 16.94 1.76 14.41 81.29 108.68 102.85 619.52 134.20
1984 53.79 33.33 178.97 86.79 27.39 8.03 11.99 10.56 20.02 32.12 41.80 76.45 581.24 178.97
1985 32.89 44.00 47.30 26.84 27.94 0.11 2.09 22.88 17.93 24.86 39.60 82.61 369.05 82.61
1986 93.50 86.46 67.54 104.61 33.66 5.39 5.61 22.55 2.09 18.37 61.82 84.92 586.52 104.61
1987 123.53 74.14 73.48 82.06 12.32 3.30 8.25 3.19 37.73 36.85 121.66 91.74 668.25 123.53
1988 157.30 135.19 70.18 93.94 3.41 5.06 2.31 1.65 11.00 57.75 63.36 68.64 669.79 157.30
1989 82.94 119.46 134.53 68.20 22.99 15.29 0.33 3.30 49.39 131.01 25.08 3.74 656.26 134.53
1990 81.84 116.60 50.05 79.97 21.45 12.43 0.33 0.55 10.12 125.95 134.97 40.48 674.74 134.97
1991 65.78 90.42 122.43 80.85 7.92 2.20 0.55 0.55 2.20 23.21 22.55 42.46 461.12 122.43
1992 32.45 10.34 26.40 23.43 13.42 11.88 3.08 10.12 19.03 50.38 40.92 100.54 341.99 100.54

Prom 76.13 72.17 90.51 72.77 19.98 6.38 5.15 7.71 18.39 58.18 66.04 69.44 562.85
P.sin 90 75.50 67.23 95.00 71.96 19.81 5.71 5.68 8.51 19.31 50.65 58.39 72.66 550.42
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

SERVICIO NACIONAL DE METEOROLOGIA E HIDROLOGIA


DIRECCION REGIONAL DE LAMBAYEQUE
ESTACION : COLASAY LATITUD :0,5º55´S DEPARTAMENTO: Cajamarca
CODIGO : PLU-2134 LONGITUD:79º0,3´'W PROVINCIA : Jaén
REGISTRO: Precipitacion(mm) ALTITUD :1150msnm DISTRITO :Colasay

DATOS: PRECIPITACIONES MAXIMAS EN 24 HORAS

AÑOS ENE FEB MAR ABR MAY JUN JUL AGOS SET OCT NOV DIC TOTAL
1983 125.95 25.30 126.50 113.30 78.10 123.20 95.70 93.50 75.90 119.90 20.90 16.72 1014.97
1984 0.00 24.20 129.80 110.55 50.05 123.75 62.48 0.00 50.05 50.49 28.38 132.55 762.30
1985 0.00 26.40 49.50 105.16 93.50 50.16 47.08 6.05 5.06 81.95 36.41 253.11 754.38
1986 43.89 20.68 105.05 238.15 30.25 17.71 2.31 22.77 45.65 126.72 43.45 63.47 760.10
1987 168.19 144.87 22.44 198.99 11.22 0.33 35.20 3.41 0.00 17.82 29.15 15.29 646.91
1988 77.99 207.02 48.29 109.78 62.92 3.63 65.01 14.08 86.24 136.29 215.16 157.52 1183.93
1989 278.19 166.43 262.46 175.67 119.46 63.47 2.42 10.23 69.08 190.85 11.33 14.63 1364.22
1990 0.00 182.05 155.65 42.90 12.98 6.93 10.89 4.40 90.31 23.10 16.28 545.49
1991 56.43 45.87 126.39 61.93 49.72 13.42 0.44 2.31 32.01 33.88 72.27 64.68 559.35
1992 37.40 62.15 180.95 100.65 38.72 8.47 8.91 24.86 21.89 132.00 98.45 53.24 767.69
Prom 78.80 90.50 120.70 125.71 54.69 41.11 33.04 18.16 42.88 98.02 57.86 78.75 835.93
P. sin 90 87.56 80.32 116.82 134.91 59.33 44.90 35.51 19.69 42.88 98.88 61.72 85.69 868.21
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

SERVICIO NACIONAL DE METEOROLOGIA E HIDROLOGIA


DIRECCION REGIONAL DE LAMBAYEQUE
ESTACION : Jaén LATITUD :0,5º46´S DEPARTAMENTO: Cajamarca
CODIGO : PLU-2130 LONGITUD:79º13´'W PROVINCIA : Jaén
REGISTRO: Precipitacion(mm) ALTITUD :1355msnm DISTRITO :Jaen

DATOS: PRECIPITACIONES MAXIMAS EN 24 HORAS

AÑOS ENE FEB MAR ABR MAY JUN JUL AGOS SET OCT NOV DIC TOTAL MAX. ANUALES
1983 125.95 11.00 250.25 138.60 75.35 0.00 0.00 0.00 0.00 102.85 25.30 42.90 772.20 250.25
1984 3.30 277.20 146.85 143.55 40.70 65.12 33.00 11.55 54.45 121.00 37.95 8.25 942.92 277.20
1985 15.95 11.55 0.00 0.00 55.55 0.00 0.00 0.00 0.00 26.40 29.70 23.10 162.25 55.55
1986 28.05 68.75 20.46 97.35 46.20 0.00 6.60 0.00 0.00 41.80 44.00 39.60 392.81 97.35
1987 94.60 89.10 19.80 52.25 1.10 0.00 39.05 0.00 13.20 68.75 8.80 7.70 394.35 94.60
1988 0.00 149.05 103.95 61.60 59.95 4.95 3.85 0.00 3.85 19.80 33.00 24.20 464.20 149.05
1989 106.70 143.55 105.60 102.30 30.25 58.30 3.30 0.00 33.00 116.05 14.85 12.65 726.55 143.55
1990 25.85 56.65 35.75 110.00 41.80 46.75 11.00 0.00 0.00 199.65 177.10 31.90 736.45 199.65
1991 39.60 24.75 103.40 67.10 5.50 11.00 0.00 0.00 5.50 28.05 95.15 52.91 432.96 103.40
1992 58.30 4.95 44.00 149.60 8.25 0.00 0.00 2.20 0.00 28.60 50.60 46.75 393.25 149.60
Prom 49.83 83.66 83.01 92.24 36.47 18.61 9.68 1.38 11.00 75.30 51.65 29.00 541.79
P. sin 90 52.49 86.66 88.26 90.26 35.87 15.49 9.53 1.53 12.22 61.48 37.71 28.67 520.17
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

REELLENO DE DATOS FALTANTES

Para hallar el dato faltante recurrimos a la siguiente formula:

PX 1  PA PB P P 
    C  ... N 
PX N  PA PB PC PN 

donde:
PA = 10.12 Dato de precipitacioó n del mes de setiembre del 90 de la estacion Chontali.
PB = 0.00 Dato de precipitacioó n del mes de setiembre del 90 de la estacion San Felipe.
PX = ?? Dato faltante de precipitacioó n del mes de setiembre del 90 de la estacion de Colasay.
PX = 42.88 Promedio sin la precipitacion del 90 estac. Colasay
PA = 19.31 Promedio sin la precipitacion del 90 estac. Chontalíó.
PB = 12.22 Promedio sin la precipitacion del 90 estac. San Felipe.
N = 2 Núó mero de estaciones con datos completos.

Despejando en la formula se tine lalo siguiente:

�_𝑋=(�_𝑋 )  ̅/𝑁 (�_𝐴/(�_𝐴 )  ̅ +�_�/(�_� )  ̅ )

Reemplazando tenemos:

�_𝑋=42.88/2
(10.12/19.31+0/12.22)

Px = 11.23
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

DATOS RELLENADOS EN 24 HORA ESTACION DE COLASAY

AÑOS ENE FEB MAR ABR MAY JUN JUL AGOS SET OCT NOV DIC TOTAL MAX. ANUALES
1983 125.95 25.30 126.50 113.30 78.10 123.20 95.70 93.50 75.90 119.90 20.90 16.72 1014.97 126.50
1984 0.00 24.20 129.80 110.55 50.05 123.80 62.48 0.00 50.05 50.49 28.38 132.55 762.35 132.55
1985 0.00 26.40 49.50 105.16 93.50 50.16 47.08 6.05 5.06 81.95 36.41 253.11 754.38 253.11
1986 43.89 20.68 105.05 238.15 30.25 17.71 2.31 22.77 45.65 126.72 43.45 63.47 760.10 238.15
1987 168.19 144.87 22.44 198.99 11.22 0.33 35.20 3.41 0.00 17.82 29.15 15.29 646.91 198.99
1988 77.99 207.02 48.29 109.78 62.92 3.63 65.01 14.08 86.24 136.29 215.16 157.52 1183.93 215.16
1989 278.19 166.43 262.46 175.67 119.46 63.47 2.42 10.23 69.08 190.85 11.33 14.63 1364.22 278.19
1990 0.00 182.05 155.65 42.90 12.98 6.93 10.89 4.40 11.23 90.31 23.10 16.28 556.72 182.05
1991 56.43 45.87 126.39 61.93 49.72 13.42 0.44 2.31 32.01 33.88 72.27 64.68 559.35 126.39
1992 37.40 62.15 180.95 100.65 38.72 8.47 8.91 24.86 21.89 132.00 98.45 53.24 767.69 180.95
Prom 78.80 90.50 120.70 125.71 54.69 41.11 33.04 18.16 39.71 98.02 57.86 78.75 837.06
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

ANÁLISIS DE CONSISTENCIA EN LAS ESTACIÓN EN 24 HARAS

Anual Acumulado
Año A B C PP A B C PPA
1983 619.52 1014.97 772.20 802.23 5628.48 8370.62 5417.94 6472.35
1984 581.24 762.35 942.92 762.17 5008.96 7355.65 4645.74 5670.12
1985 369.05 754.38 162.25 428.56 4427.72 6593.30 3702.82 4907.95
1986 586.52 760.10 392.81 579.81 4058.67 5838.92 3540.57 4479.39
1987 668.25 646.91 394.35 569.84 3472.15 5078.82 3147.76 3899.58
1988 669.79 1183.93 464.20 772.64 2803.90 4431.91 2753.41 3329.74
1989 656.26 1364.22 726.55 915.68 2134.11 3247.98 2289.21 2557.10
1990 674.74 556.72 736.45 655.97 1477.85 1883.76 1562.66 1641.42
1991 461.12 559.35 432.96 484.48 803.11 1327.04 826.21 985.45
1992 341.99 767.69 393.25 500.98 341.99 767.69 393.25 500.98

9000.00

8000.00 R² = 0.9977473542

7000.00

6000.00
ESTACION A
R² = 0.9978636783
5000.00 Linear (ESTACION A)
R² = 0.9913702688
ESTACION B
4000.00 Linear (ESTACION B)
ESTACION C
3000.00
Linear (ESTACION C)
2000.00

1000.00

0.00
0.00 2000.00 4000.00 6000.00 8000.00
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

MÉTODO DE THIESSEN

PRECIPITACIONES MEDIAS EN 24 HORAS

AÑOS Nº DATOS CHONTALI (A) COLASAY (B) JAEN(C) CHONTALY (m2) COLASAY (Km2) JAEN (Km2) AREA CUENCA Pmed. (mm)
1983 1 134.20 126.50 250.25 2653056.19 2576760.92 2886833.16 8116650.27 173.03
1984 2 178.97 132.55 277.20 2653056.19 2576760.92 2886833.16 8116650.27 199.17
1985 3 82.61 253.11 55.55 2653056.19 2576760.92 2886833.16 8116650.27 127.11
1986 4 104.61 238.15 97.35 2653056.19 2576760.92 2886833.16 8116650.27 144.42
1987 5 123.53 198.99 94.60 2653056.19 2576760.92 2886833.16 8116650.27 137.20
1988 6 157.30 215.16 149.05 2653056.19 2576760.92 2886833.16 8116650.27 172.73
1989 7 134.53 278.19 143.55 2653056.19 2576760.92 2886833.16 8116650.27 183.35
1990 8 134.97 182.05 199.65 2653056.19 2576760.92 2886833.16 8116650.27 172.92
1991 9 122.43 126.39 103.40 2653056.19 2576760.92 2886833.16 8116650.27 116.92
1992 10 100.54 180.95 149.60 2653056.19 2576760.92 2886833.16 8116650.27 143.52

RESUMEN PRECIPITACIONES MAXIMAS EN 24 HORAS

AÑO P(mm)
1 173.03 ANALISIS ESTADISTICA
2 199.17 Media 157.04
3 127.11 Mediana 158.58
4 144.42 Desviación estánda 26.80
5 137.20 Mínimo 116.92
6 172.73 Máximo 199.17
7 183.35 Suma 1570.37
8 172.92 Cuenta 10.00
9 116.92
10 143.52
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

DISTRIBUCIÓN DE LAS PRECIPITACIONES MAX. EN 24 HORAS

ANÁLISIS CON DISTRIBUCIÓN LOG - NORMAL

AÑO PREC. ORDENADAS F(x) f(x)


1 199.170 0.9420677 0.0043249
2 183.345 0.8368994 0.0091944
3 173.031 0.7247028 0.0124588
4 172.921 0.7233322 0.0124893
5 172.734 0.7209971 0.0125406
6 144.422 0.3189046 0.0133264
7 143.517 0.3069321 0.0131085
8 137.197 0.2295226 0.0113186
9 127.114 0.1320609 0.0079809
10 116.919 0.0671760 0.0048541
MEDIA            157.037 
DESV.EST.             26.796 

HISTOGRAMA

0.014

0.012

0.010

0.008

0.006

0.004

0.002

0.000
100.000 150.000 200.000 250.000
precipitacion media
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

ANÁLISIS CON DISTRIBUCIÓN LOG - NORMAL DE 2 PARAMETROS:

AÑO PREC. ORDENADAS y = ln (x) F(x) f(x)


1 199.170 5.2941612 0.9258485 0.8079173
2 183.345 5.2113713 0.8337056 1.4363695
3 173.031 5.1534695 0.7374684 1.8767586
4 172.921 5.1528343 0.7362749 1.8811132
5 172.734 5.1517547 0.7342401 1.8884796
6 144.422 4.9727414 0.3427646 2.1160063
7 143.517 4.9664501 0.3295523 2.0838308
8 137.197 4.9214143 0.2418292 1.7971695
9 127.114 4.8450811 0.1271646 1.1994123
10 116.919 4.7614797 0.0524865 0.6171502
MEDIA      5.043 
DESV.EST.      0.174 
C.ASIMETRIA     (0.216)

LN2
2.500

2.000

1.500

1.000

0.500

0.000
70

90

10

30
80

00

20

40

Y=LnX
4.

5.

5.
4.
4.
5.

5.

5.
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

ANALISIS CON DISTRIBUCION LOG - NORMAL DE 3 PARAMETROS:

AÑO PREC. ORDENADAS y = ln (x-a) F(x) f(x)


1 199.170 5.4209354 0.9283510 0.9264801
2 183.345 5.3483701 0.8344198 1.6863228
3 173.031 5.2980713 0.7359338 2.2160714
4 172.921 5.2975216 0.7347143 2.2212707
5 172.734 5.2965875 0.7326353 2.2300633
6 144.422 5.1436631 0.3388138 2.4801612
7 143.517 5.1383629 0.3257689 2.4418220
8 137.197 5.1005766 0.2395539 2.1049277
9 127.114 5.0371707 0.1276653 0.1276653
10 116.919 4.9686932 0.0546187 0.0546187
MEDIA                5.205 
DESV.EST.                0.148 
a              (26.920)
C.ASIMETRIA               (0.182)

LN3

3.000

2.500

2.000

1.500

1.000

0.500

0.000
4.90 5.00 5.10 5.20 5.30 5.40 5.50
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

ANALISIS CON DISTRIBUCION GUMBEL:

Var. Reducida
AÑO
PREC. ORDENADAS y = (x - u)/a Tr
1 199.170      1.99       7.82 
2 183.345      1.43       4.69 
3 173.031      1.06       3.42 
4 172.921      1.06       3.41 
5 172.734      1.05       3.39 
6 144.422      0.05       1.63 
7 143.517      0.02       1.60 
8 137.197     ­0.21       1.41 
9 127.114     ­0.57       1.21 
10 116.919     ­0.93       1.09 

x medio      157.037 
desv. Est x (Sx)       26.796 

n = número de datos    10.000 


yn medio =     0.495 
Sn =     0.950 

parámetros, según n
a = Sx / Sn      28.215 
u = x-yn*a     143.065 

9.00

8.00

7.00

6.00
PRECIPITACION MEDIA

5.00

4.00

3.00

2.00

1.00

-
PRECI
3.00
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
2.00

1.00

-
100.000 150.000 200.000 250.000

TIEPO DE RETORNO AÑOS


Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

BONDAD DE AJUSTE DE LAS PRECIPITACIONES

Probabilidad de excedencia F(x) Diferencia Delta D


DATOS
Empírica Normal LN2 LN3 Gumbel Normal LN2 LN3 Gumbel
1 0.091 0.05793 0.07415 0.07165    0.128  0.033 0.017 0.019 0.0370
2 0.182 0.16310 0.16629 0.16558    0.213  0.019 0.016 0.016 0.031
3 0.273 0.27530 0.26253 0.26407    0.292  0.003 0.010 0.009 0.020
4 0.364 0.27667 0.26373 0.26529    0.293  0.087 0.100 0.098 0.070
5 0.455 0.27900 0.26576 0.26736    0.295  0.176 0.189 0.187 0.160
6 0.545 0.68110 0.65724 0.66119    0.614  0.136 0.112 0.116 0.069
7 0.636 0.69307 0.67045 0.67423    0.626  0.057 0.034 0.038 0.010
8 0.727 0.77048 0.75817 0.76045    0.708  0.043 0.031 0.033 0.019
9 0.818 0.86794 0.87284 0.87233    0.828  0.050 0.055 0.054 0.010
10 0.909 0.93282 0.94751 0.94538    0.920  0.024 0.038 0.036 0.011

0.17554 0.18879 0.18718 0.15966


Aceptada Aceptada Aceptada Aceptada
0.4301
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

CURVAS IDF
ECUACIÓN DE DICK :

d 0.25
Pd  P24 ( )
1440
DONDE:
Pd: Presipitacion total (mm)
P24 : Precipitacion maxima en 24 horas
d : duración del aguacero en minutos.

Precipitaciones (Pd : mm)


Pmáx. 24horas
Año Duración de Lluvia, en minutos
(mm)
10 20 30 40 50 60
1 173.031 49.95 59.40 65.74 70.64 74.69 78.18
2 199.170 57.50 68.37 75.67 81.31 85.98 89.99
3 127.114 36.69 43.64 48.29 51.89 54.87 57.43
4 144.422 41.69 49.58 54.87 58.96 62.34 65.25
5 137.197 39.61 47.10 52.12 56.01 59.22 61.99
6 172.734 49.86 59.30 65.62 70.52 74.56 78.04
7 183.345 52.93 62.94 69.66 74.85 79.14 82.84
8 172.921 49.92 59.36 65.70 70.59 74.64 78.13
9 116.919 33.75 40.14 44.42 47.73 50.47 52.82
10 143.517 41.43 49.27 54.52 58.59 61.95 64.84

Promedio 45.33 53.91 59.66 64.11 67.79 70.95


Desv. Stand. 7.74 9.20 10.18 10.94 11.57 12.11
C.ASIMETRIA 0.010 0.010 0.010 0.010 0.010 0.010
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

PRECIPITACIONES PARA CADA TIEMPO DE RETORNO SEGÚN GUMBEL

Tr 10 10 10 10 10 10
Yn 0.4952 0.4952 0.4952 0.4952 0.4952 0.4952
Sn 0.9496 0.9496 0.9496 0.9496 0.9496 0.9496
a 8.15 9.69 10.72 11.52 12.18 12.75
u 41.30 49.11 54.35 58.41 61.76 64.64
y 2.25 2.25 2.25 2.25 2.25 2.25
x 59.63 70.91 78.48 84.33 89.17 93.33

Tr 25 25 25 25 25 25
Yn 0.4952 0.4952 0.4952 0.4952 0.4952 0.4952
Sn 0.9496 0.9496 0.9496 0.9496 0.9496 0.9496
a 8.15 9.69 10.72 11.52 12.18 12.75
u 41.30 49.11 54.35 58.41 61.76 64.64
y 3.20 3.20 3.20 3.20 3.20 3.20
x 67.35 80.10 88.64 95.25 100.72 105.41

Tr 50 50 50 50 50 50
Yn 0.4952 0.4952 0.4952 0.4952 0.4952 0.4952
Sn 0.9496 0.9496 0.9496 0.9496 0.9496 0.9496
a 8.15 9.69 10.72 11.52 12.18 12.75
u 41.30 49.11 54.35 58.41 61.76 64.64
y 3.90 3.90 3.90 3.90 3.90 3.90
x 73.08 86.91 96.18 103.36 109.29 114.38

Tr 100 100 100 100 100 100


Yn 0.4952 0.4952 0.4952 0.4952 0.4952 0.4952
Sn 0.9496 0.9496 0.9496 0.9496 0.9496 0.9496
a 8.15 9.69 10.72 11.52 12.18 12.75
u 41.30 49.11 54.35 58.41 61.76 64.64
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

y 4.60 4.60 4.60 4.60 4.60 4.60


x 78.77 93.68 103.67 111.40 117.79 123.28

RESUMEN DE PRECIPITACÍONES (mm)

Duración de la lluvia en min.


Tr 10 20 30 40 50 60
10 59.63 70.91 78.48 84.33 89.17 93.33
25 67.35 80.10 88.64 95.25 100.72 105.41
50 73.08 86.91 96.18 103.36 109.29 114.38
100 78.77 93.68 103.67 111.40 117.79 123.28

INTENSIDADES PARA CADA TIEMPO DE RETORNO (mm/h)

Duración de la lluvia en min.


Tr 10 20 30 40 50 60
10 357.78 212.74 156.96 126.49 107.00 93.33
25 404.12 240.29 177.29 142.88 120.86 105.41
50 438.50 260.74 192.37 155.03 131.14 114.38
100 472.63 281.03 207.34 167.10 141.35 123.28
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

GRÁFICA DE LAS CURVAS IDF

500.00

450.00

400.00

350.00
Tr=
300.00 10
INTENSIDAD (mm/h)

Tr=
25
250.00 Tr=
50
200.00

150.00

100.00

50.00

0.00
0 10 20 30 40 50 60 70

TIEMPO (minutos)
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

CÁLCULO DE CAUDAL MÉTODO RACIONAL

Hallando el Tiempo de concentracion:

L = 4021 m
3 0.385
L  H = 1000 m.s.n.m
Tc  0.0195*  
H

Tc = 20 min.

Tc=20 minutos y Tr=100 años.


Le corresponde una intensidad de:
I=280 mm/Hr.
Luego el caudal es:
Donde:
CIA C= 0.25
Q
3.6 I= 280 mm/Hr.
A= 9.5 Km2

Q= 184.722 m3/seg.
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

METODO DEL BLOQUE ALTERNO PARA TR = 10 AÑOS

PROFUNDIDAD PROFUNDIDAD
TIEMPO (min)
DURACION INTENSIDAD P. ACUM. (mm) INCREMENTAL ORDENADA PRECI. (mm)
de a
10 357.78 59.63 59.63 59.63 10.00 4.16
20 212.74 70.91 11.28 11.28 10.00 20.00 5.85
30 156.96 78.48 7.57 7.57 20.00 30.00 11.28
40 126.49 84.33 5.85 5.85 30.00 40.00 59.63
50 107.00 89.17 4.84 4.84 40.00 50.00 7.57
60 93.33 93.33 4.16 4.16 50.00 60.00 4.84

HIETOGRAMA (Tr = 10 años)


70.00
60.00
50.00
PREC. (mm)

40.00
30.00
20.00
10.00
0.00
10 20 30 40 50 60
TIEMPO (min)
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

METODO DEL BLOQUE ALTERNO PARA TR = 25 AÑOS

PROFUNDIDAD PROFUNDIDAD
TIEMPO (min)
DURACION INTENSIDAD P. ACUM. (mm) INCREMENTAL ORDENADA PREC. (mm) PREC. (cm)
de a
10 404.12 67.35 67.35 67.35 10.00 4.70 0.47
20 240.29 80.10 12.74 12.74 10.00 20.00 6.61 0.66
30 177.29 88.64 8.54 8.54 20.00 30.00 12.74 1.27
40 142.88 95.25 6.61 6.61 30.00 40.00 67.35 6.74
50 120.86 100.72 5.46 5.46 40.00 50.00 8.54 0.85
60 105.41 105.41 4.70 4.70 50.00 60.00 5.46 0.55

HIETOGRAMA (TR = 25 AÑOS)


80.00

70.00

60.00

50.00
PREC.(mm)

40.00

30.00

20.00

10.00

0.00
10 20 30 40 50 60
TIEMPO (min)
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

METODO DEL BLOQUE ALTERNO PARA TR = 50 AÑOS

PROFUNDIDAD PROFUNDIDAD
TIEMPO (min)
DURACION INTENSIDAD P. ACUM. (mm) INCREMENTAL ORDENADA PRECIPITACION
de a
10 438.50 73.08 73.08 73.08 10.00 5.10
20 260.74 86.91 13.83 13.83 10.00 20.00 7.17
30 192.37 96.18 9.27 9.27 20.00 30.00 13.83
40 155.03 103.36 7.17 7.17 30.00 40.00 73.08
50 131.14 109.29 5.93 5.93 40.00 50.00 9.27
60 114.38 114.38 5.10 5.10 50.00 60.00 5.93

HIETOGRAMA (TR = 50 AÑOS)


80.00
70.00
60.00
50.00
PREC. (mm)

40.00
30.00
20.00
10.00
0.00
10 20 30 40 50 60
TIEMPO (min)
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

METODO DEL BLOQUE ALTERNO PARA TR = 100 AÑOS

PROFUNDIDAD PROFUNDIDAD
TIEMPO (min)
DURACION INTENSIDAD P. ACUMULADA (mm) INCREMENTAL ORDENADA PRECIPITACION
de a
10 472.63 78.77 78.77 78.77 10.00 5.49
20 281.03 93.68 14.90 14.90 10.00 20.00 7.73
30 207.34 103.67 9.99 9.99 20.00 30.00 14.90
40 167.10 111.40 7.73 7.73 30.00 40.00 78.77
50 141.35 117.79 6.39 6.39 40.00 50.00 9.99
60 123.28 123.28 5.49 5.49 50.00 60.00 6.39

HIETOGRAMA (TR = 100 AÑOS)


90.00
80.00
70.00
60.00
PREC. (mm)

50.00
40.00
30.00
20.00
10.00
0.00
10 20 30 40 50 60
TIEMPO (min)
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

USAREMOS EL METODO SCS PARA ABSTRACCIONES PARA


HALLAR LA PREC. EFECTIVA PARA CUENCA DEL RIO

EL PROCESO QUE VAMOS A SEGUIR PARA HALLAR LA


PRECIPITACION EFECTIVA ES EL SIGUIENTE:

I.- Primeramente veremos la clasificación de suelos; que porcentajes de cada uno


de estos tenemos

Supongamos que tenemos los siguientes grupos hidrológicos :


Grupo A = 30%
Grupo B = 70%
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

II.- Veamos el uso de suelos:

CN para usos selectos de suelo agrícola, urbanos y suburbanos


(AMC(II) Ia=0.25)

Supongamos el siguiente uso de suelo:


bosque, con cubierta buena……………………………..………………… 35%
Pastizales o campo de animales en condiciones buenas……………25%
vegas de rios y praderas en condiciones buenas……………………… 20%
Calles y carreteras (superficie dura)……………………………….. 20%

Ahora calcularemosdel Numero adimensional de curvas (CN)


Consideraremos condiciones húmedas; por lo que tendremos
que utilizar las siguientes ecuaciones

NOTA: S y CN dependen de las condiciones antecentes de lluvia.

CN (I) …….. Condiciones Secas


CN (II) ……..Condiciones Naturales
CN (III) …....Condiciones Húmedas

Grupo hidrologico de suelo


Uso de suelo
0.3 * A 0.7 * B
% CN Prod. % CN Prod.
Bosques 10.5 25 2.625 24.5 55 13.475
Pastizales 7.5 39 2.925 17.5 61 10.675
Vegas de rios y prad. 6 30 1.8 14 58 8.12
Calles y carreteras 6 74 4.44 14 84 11.76
∑= 11.79 ∑= 44.03

El CN ponderado será entonces = 55.82 = CN (II)= 55.82

Ahora calculamos CN(III)

CN(III)= 74.3982

Ahora calculamos S

1000
S  10
CN ( III)
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

1000 S= 3.44 Pulg.


S  10
CN ( III) S= 87.41 mm.
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

USAREMOS EL METODO SCS PARA ABSTRACCIONES PARA


HALLAR LA PREC. EFECTIVA PARA CUENCADE DRENAJE MAYOR

Grupo Hidrológico de suelo


USO DE SUELO B C
% CN PROD. % CN PROD.
tierra cultivada con granos cerrados 20 77 15.4 20 85 17
Terreno abierto: Buena cubierta 10 61 6.1 10 74 7.4
Aceptable cubierta 20 69 13.8 20 79 15.8
TOTAL 50 35.3 50 40.2

CN : 75.5

El CN ponderado será entonces = CN = 75.5

Ahora calculamos CN(III)

CN(III)= 87.64

Ahora calculamos S

1000 S= 1.41 Pulg.


S  10 S= 35.84 mm.
CN ( III)
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

PRECIPITACIÓN EFECTIVA

Hallando Ia, con la siguiente formula:

Ia  0.2S Ia= 7 mm

Hallamos Fa, con la siguiente formula:

S ( P  Ia ) S= 36 mm
Fa 
P  Ia  S
Hallamos Precipitación efectiva, con la siguiente formula:

Pe  P  Ia  Fa

Lluvia Abstracciones Exceso de Hietograma de Hietograma de


Tiempo acumuladas lluvia
acumulada exceso de lluvia exceso de lluvia
(min) acumulado
(mm) (mm) (mm) (Cm)
Ia Fa
0 0 0 0.00 0.00 0 0.00
10 67.35 7 22.46 37.72 37.72 3.77
20 80.10 7 24.03 48.90 11.18 1.12
30 88.64 7 24.89 56.59 7.68 0.77
40 95.25 7 25.47 62.61 6.03 0.60
50 100.72 7 25.91 67.64 5.03 0.50
60 105.41 7 26.26 71.99 4.35 0.43

Tiempo (h) Hietograma de exceso de


lluvia (Cm)
0.00 0.00
0.50 0.77
1.00 0.43

HIETOGRAMA DE PRECIPIACIÓN EFECTIVA


0.90
0.80
0.70
Precipitación (cm)

0.60
0.50
0.40
0.30
0.20
0.10
0.00
0.00 0.50 1.00
Tiempo (h)
0.10
0.00
0.00 - Sede Jaén0.50
Universidad Nacional De Cajamarca 1.00 Ingenieria de Drenaje
Tiempo (h)

FORMULAS PARA EL CALCULO DEL HIDROGRAMA TRIANGULAR

El tiempo de recesión, tr, puede aproximarse a:

Como el área bajo el HU debe ser igual a una escorrentía de 1 cm,


puede demostrarse que:

Donde:
A : es el área de drenaje en Km2
Tp : es el tiempo de ocurrencia del pico en horas
Donde:

Donde:
tp: Tiempo de retardo (entre el centroide del hietograma y el pico de caudal) (h)

tc: Tiempo de concentración de la cuenca.

El tiempo de ocurrencia del pico, Tp, se puede expresar así:

Además:
D: duración de la lluvia (h)

Hidrograma unitario triangular

tp

qp

t
Tp tr
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

CALCULO DE HIDROGRAMA SINTETICO TRIANGULAR DEL SCS

Datos de entrada:

Long cauce ………………… 605 m


Cota max ……………………. 837 m
Cota min……………………. 765 m
Superficie…………………… 0.093 km2
Duración P neta…………… 1 horas

Cálculos:
Tiempo de concentración:
0.385
�L3 �
tC  0.01947 � � Fórmula de Kirpich
�H �
Tc= 6.13 minutos
Tc= 0.10 horas

Tiempo pico:
t P  0.5D  0.6tC
Tp= 0.56 horas

Tiempo base:
tb  2.67tp
Tb= 1.50 horas
DATOS H.U.
Tiempo de recesión=Tr= 0.93731443 horas
Tiempo Caudal (m3/s)
Caudal pico: 0.208* P * A 0 0
Qp 
tp 0.5 0.34
QP= 0.34 m3/s 1 0.17
1.5 0
Gráfica del hidrograma triangular:

HIDROGRAMA TRIANGULAR SCS


0.4
0.35
0.3
0.25
caudal
0.2
0.15
0.1
0.05
HIDROGRAMA TRIANGULAR SCS
Universidad Nacional
0.4 De Cajamarca - Sede Jaén Ingenieria de Drenaje
0.35
0.3
0.25
caudal
0.2
0.15
0.1
0.05
0
0 0.5 1 1.5
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

H.U. DE DISEÑO PARA CUENCA DE DRENAJE MAYOR

Precipitación en (Cm) Q.
Caudal
Tiempo Resultante
(m3/s) 0.00 0.77 0.43 (m3/s)
0 0 0.00 0.00
0.5 0.34 0.00 0.00 0.00
1 0.17 0.00 0.26 0.00 0.26
1.5 0 0.00 0.13 0.15 0.28
2 0.00 0.07 0.07
2.5 0.00 0.00

H.U. DE DISEÑO
0.30
0.25
0.20
Q. Resultante
0.15
0.10
0.05
0.00
0 0.5 1 1.5 2 2.5 3

El caudal de diseño para la mayor seccion del canal que evacuará las aguas de
lluvia de la cuenca de drenaje mayor es el que se muestra en el gráfico.

Q. RESULTANTE = 0.28 m3/s


Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

PRECIPITACIÓN EFECTIVA CUENCA DEL RIO

Hallando Ia, con la siguiente formula:

Ia  0.2S Ia= 17 mm

Hallamos Fa, con la siguiente formula:

S ( P  Ia ) S= 87 mm
Fa 
P  Ia  S
Hallamos Precipitación efectiva, con la siguiente formula:

Pe  P  Ia  Fa

Abstracciones Exceso de Hietograma Hietograma


Lluvia
Tiempo acumuladas lluvia de exceso de exceso
acumulada
(min) Ia Fa acumulado de lluvia de lluvia
(mm) (mm) (mm) (Cm)
0 0 0 0.00 0.00 0 0.00
10 78.77 17 36.03 25.26 25.26 2.53
20 93.68 17 40.71 35.49 10.22 1.02
30 103.67 17 43.40 42.79 32.57 3.26
40 111.40 17 45.27 48.65 16.08 1.61
50 117.79 17 46.71 53.60 37.52 3.75
60 123.28 17 47.86 57.94 20.41 2.04

Tiempo (h) Hietograma de exceso de


lluvia (Cm)
0.00 0.00
0.50 3.26
1.00 2.04

HIETOGRAMA DE PRECIPITACION EFECTIVA


3.50
3.00
Precipitación (cm)

2.50
2.00
1.50
1.00
0.50
0.00
0.00 0.50 1.00
Tíempo (h)
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

CALCULO DE HIDROGRAMA SINTETICO TRIANGULAR DEL SCS

Datos de entrada:

Long cauce ………………… 4021 km.


Cota max ……………………. 1750 m
Cota min……………………. 740 m
Superficie…………………… 9.5 km2
Duración P neta…………… 1 horas

Cálculos:
Tiempo de concentración:
0.385
�L3 �
tC  0.01947 � � Fórmula de Kirpich
�H �
Tc= 20 minutos
Tc= 0.33 horas

Tiempo pico:
t P  0.5D  0.6tC
Tp= 0.70 horas

Tiempo base:

Tb= 1.86 horas


DATOS H.U.
Tiempo de recesión=Tr= 1.16493208 horas
Tiempo Q.(m3/s)
Caudal pico: 0.208* P * A 0 0
Qp 
tp 0.5 14.17
QP= 28.33 m3/s 1 28.33
1.5 14.17
Gráfica del hidrograma triangular: 2 0

HIDROGRAMA TRIANGULAR
30

25

20
CAUDAL
15

10

0
0 0.5 1 1.5 2
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

HIDROGRAMA TRIANGULAR
30

25

20
CAUDAL
15

10

0
0 0.5 1 1.5 2
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

H.U. DE DISEÑO PARA CUENCA DEL RIO

Precipitación en (Cm) Q.
Caudal
Tiempo Resultante
(m3/s) 0.00 3.26 2.04 (m3/s)
0 0 0.00 0.00
0.5 14.17 0.00 0.00 0.00
1 28.33 0.00 46.15 0.00 46.15
1.5 14.17 0.00 92.27 28.93 121.19
2 0 0.00 46.15 57.83 103.98
2.5 0.00 28.93 28.93
3 0.00 0.00

CAUDAL RESULTANTE
140.00
120.00
100.00
80.00 CAUDAL RESULTANTE
60.00
40.00
20.00
0.00
0 0.5 1 1.5 2 2.5 3 3.5

El caudal de diseño para la mayor seccion del canal que evacuará las aguas de
lluvia de la cuenca de drenaje mayor es el que se muestra en el gráfico.

Q. RESULTANTE = 121.19 m3/s


Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

AREAS TRIBUTARIAS

CODIGO VALOR m2 VALORr en km2 VALOR en ha


A1 300.271 0.000300 0.030027
A2 303.072 0.000303 0.030307
A3 905.483 0.000905 0.090548
A4 350.900 0.000351 0.035090
A5 348.918 0.000349 0.034892
A6 718.336 0.000718 0.071834
A7 405.579 0.000406 0.040558
A8 342.796 0.000343 0.034280
A9 415.963 0.000416 0.041596
A10 350.917 0.000351 0.035092
A11 397.077 0.000397 0.039708
A12 839.850 0.000840 0.083985
A13 1044.198 0.001044 0.104420
A14 535.210 0.000535 0.053521
A15 1066.708 0.001067 0.106671
A16 1298.984 0.001299 0.129898
A17 673.375 0.000673 0.067338
A18 778.666 0.000779 0.077867
A19 1061.985 0.001062 0.106199
A20 960.133 0.000960 0.096013
A21 1000.346 0.001000 0.100035
A22 867.514 0.000868 0.086751
A23 854.013 0.000854 0.085401
A24 1399.159 0.001399 0.139916
A25 1106.944 0.001107 0.110694
A26 1322.008 0.001322 0.132201
A27 1147.254 0.001147 0.114725
A28 989.105 0.000989 0.098911
A29 1659.241 0.001659 0.165924
A30 1389.021 0.001389 0.138902
A31 872.773 0.000873 0.087277
A32 1428.737 0.001429 0.142874
A33 1369.170 0.001369 0.136917
A34 792.926 0.000793 0.079293
A35 720.716 0.000721 0.072072
A36 960.086 0.000960 0.096009
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

A37 1271.744 0.001272 0.127174


A38 812.689 0.000813 0.081269
A39 1108.097 0.001108 0.110810
A40 760.030 0.000760 0.076003
A41 667.101 0.000667 0.066710
A42 1165.241 0.001165 0.116524
A43 710.822 0.000711 0.071082
A44 694.265 0.000694 0.069427
A45 975.618 0.000976 0.097562
A46 824.877 0.000825 0.082488
A47 631.853 0.000632 0.063185
A48 818.214 0.000818 0.081821
A49 1179.388 0.001179 0.117939
A50 1423.950 0.001424 0.142395
A51 664.320 0.000664 0.066432
A52 664.320 0.000664 0.066432
A53 803.175 0.000803 0.080318
A54 803.175 0.000803 0.080318
A55 644.011 0.000644 0.064401
A56 1273.379 0.001273 0.127338
A57 752.012 0.000752 0.075201
A58 908.375 0.000908 0.090838
A59 1151.538 0.001152 0.115154
A60 978.446 0.000978 0.097845
A61 1035.980 0.001036 0.103598
A62 961.789 0.000962 0.096179
A63 961.886 0.000962 0.096189
A64 1351.257 0.001351 0.135126
A65 1611.966 0.001612 0.161197
A66 1021.314 0.001021 0.102131
A67 977.893 0.000978 0.097789
A68 730.002 0.000730 0.073000
A69 735.591 0.000736 0.073559
A70 1215.931 0.001216 0.121593
A71 766.068 0.000766 0.076607
A72 592.677 0.000593 0.059268
A73 762.6 0.000763 0.076260
A74 553.066 0.000553 0.055307
A75 706.995 0.000707 0.070700
A76 995.499 0.000995 0.099550
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

A77 676.325 0.000676 0.067633


A78 770.181 0.000770 0.077018
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

CALCULO DE LOS TIEMPOS DE CONCENTRACION

Area (ha) Longitud DESNIVEL pendiente ni tc tc


AREA TRAMO Ho Hf
REFERENCIA (m) m/m (Manning) (min) (min)
A1 P01 - B01 0.03003 29.91 766.55 763.45 3.100 0.1036 0.014 0.6379 10
A2 P01 - B01 0.03031 29.91 766.55 763.45 3.100 0.1036 0.014 0.6379 10
A22 B01 - B05 0.08675 58.54 763.45 757.97 5.480 0.0936 0.014 1.1126 10
A23 B01 - B05 0.08540 58.54 763.45 757.97 5.480 0.0936 0.014 1.1126 10
A26 B05 - B09 0.13220 71.62 757.97 753.97 4.000 0.0559 0.014 1.5854 10
CALLE A27 B05 - B09 0.11473 71.62 757.97 753.97 4.000 0.0559 0.014 1.5854 10
ZARUMILLA A51 B09 - B13 0.06643 59.89 753.97 750.38 3.590 0.0599 0.014 1.3443 10
A52 B09 - B13 0.06643 59.89 753.97 750.38 3.590 0.0599 0.014 1.3443 10
A54 B13 - B17 0.08032 53.79 750.38 746.65 3.730 0.0693 0.014 1.1701 10
A55 B13 - B17 0.06440 53.79 750.38 746.65 3.730 0.0693 0.014 1.1701 10
A77 B17 - B21 0.06763 45.17 746.65 742.81 3.840 0.0850 0.014 0.9457 10
A78 B17 - B21 0.07702 45.17 746.65 742.81 3.840 0.0850 0.014 0.9457 10

A04 P02 - B02 0.03509 33.55 764.45 761.15 3.300 0.0984 0.014 0.7111 10
A05 P02 - B02 0.03489 33.55 764.45 761.15 3.300 0.0984 0.014 0.7111 10
A19 B02 - B06 0.10620 58.80 761.15 757.46 3.690 0.0628 0.014 1.3022 10
A20 B02 - B06 0.09601 58.80 761.15 757.46 3.690 0.0628 0.014 1.3022 10
A29 B06 - B10 0.16592 69.95 757.46 753.48 3.980 0.0569 0.014 1.5458 10
A30 B06 - B10 0.13890 69.95 757.46 753.48 3.980 0.0569 0.014 1.5458 10
CALLE SUCRE
A47 B10 - B14 0.06319 53.94 753.48 749.61 3.870 0.0717 0.014 1.1573 10
A48 B10 - B14 0.08182 53.94 753.48 749.61 3.870 0.0717 0.014 1.1573 10
A57 B14 - B18 0.07520 57.72 749.61 745.99 3.620 0.0627 0.014 1.2841 10
A58 B14 - B18 0.09084 57.72 749.61 745.99 3.620 0.0627 0.014 1.2841 10
A74 B18 - B22 0.05531 45.19 745.99 742.15 3.840 0.0850 0.014 0.9462 10
A75 B18 - B22 0.07070 45.19 745.99 742.15 3.840 0.0850 0.014 0.9462 10
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

A07 P03 - B03 0.04056 36.80 763.25 760.25 3.000 0.0815 0.014 0.8208 10
A08 P03 - B03 0.03428 36.80 763.25 760.25 3.000 0.0815 0.014 0.8208 10
A15 B03 - B07 0.10667 60.77 760.48 757.15 3.330 0.0548 0.014 1.4073 10
A16 B03 - B07 0.12990 60.77 760.48 757.15 3.330 0.0548 0.014 1.4073 10
A32 B07 - B11 0.14287 68.97 757.15 752.98 4.170 0.0605 0.014 1.4937 10
CALLE A33 B07 - B11 0.13692 68.97 757.15 752.98 4.170 0.0605 1.014 1.4937 10
ALMENDRAS A43 B11 - B15 0.07108 50.56 752.98 749.98 3.000 0.0593 2.014 1.1846 10
A44 B11 - B15 0.06943 50.56 752.98 749.98 3.000 0.0593 3.014 1.1846 10
A61 B15 - B19 0.10360 61.83 749.98 744.98 5.000 0.0809 4.014 1.2277 10
A63 B15 - B19 0.09619 61.83 749.98 744.98 5.000 0.0809 5.014 1.2277 10
A71 B19 - B23 0.07661 43.31 744.98 742.25 2.730 0.0630 6.014 1.0273 10
A72 B19 - B23 0.05927 43.31 744.98 742.25 2.730 0.0630 7.014 1.0273 10

A11 P04 - B04 0.03971 37.76 761.84 760.65 1.190 0.0315 9.014 1.2071 10
A10 P04 - B04 0.03509 37.76 761.84 760.65 1.190 0.0315 10.014 1.2071 10
A12 B04 - B08 0.08399 60.62 760.48 757.94 2.540 0.0419 11.014 1.5575 10
A13 B04 - B08 0.10442 60.62 760.48 757.94 2.540 0.0419 12.014 1.5575 10
A36 B08 - B12 0.09601 65.11 757.94 754.45 3.490 0.0536 13.014 1.4967 10
CALLE A37 B08 - B12 0.12717 65.11 757.94 754.45 3.490 0.0536 14.014 1.4967 10
HUAMANTANGA A40 B12 - B16 0.07600 53.32 754.45 751.55 2.900 0.0544 15.014 1.2761 10
A41 B12 - B16 0.06671 53.32 754.45 751.55 2.900 0.0544 16.014 1.2761 10
A66 P16 - B20 0.10213 63.84 751.55 746.78 4.770 0.0747 17.014 1.2972 10
A67 P16 - B20 0.09779 63.84 751.55 746.78 4.770 0.0747 18.014 1.2972 10
A68 B20 - B24 0.07300 46.85 746.78 743.78 3.000 0.0640 19.014 1.0848 10
A69 B20 - B24 0.07356 46.85 746.78 743.78 3.000 0.0640 20.014 1.0848 10

A03 B01 - B02 0.09055 66.94 763.45 761.15 2.300 0.0344 22.014 1.8145 10
A21 B01 - B02 0.10003 66.94 763.45 761.15 2.300 0.0344 23.014 1.8145 10
CALLE VISTA A06 B02 - B03 0.07183 58.64 761.15 760.48 0.670 0.0114 24.014 2.5038 10
ALEGRE A17 B02 - B03 0.06734 58.64 761.15 760.48 0.670 0.0114 25.014 2.5038 10
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
CALLE VISTA
ALEGRE
A09 B03 - B04 0.04160 47.54 760.65 760.25 0.400 0.0084 26.014 2.3965 10
A14 B03 - B04 0.05352 47.54 760.65 760.25 0.400 0.0084 27.014 2.3965 10

A24 B05 - B06 0.13992 66.82 757.97 757.46 0.510 0.0076 29.014 3.2338 10
A25 B05 - B06 0.11069 66.82 757.97 757.46 0.510 0.0076 30.014 3.2338 10
CALLE NICOLAS A18 B06 - B07 0.07787 59.23 757.46 757.15 0.310 0.0052 31.014 3.4078 10
GUTIERREZ A31 B06 - B07 0.08728 59.23 757.46 757.15 0.310 0.0052 32.014 3.4078 10
A35 B07 - B08 0.07207 54.51 757.15 757.94 0.790 0.0145 33.014 2.1598 10
A34 B07 - B08 0.07929 54.51 757.15 757.94 0.790 0.0145 34.014 2.1598 10

A28 B09 - B10 0.09891 66.65 753.97 753.48 0.490 0.0074 36.014 3.2744 10
A49 B09 - B10 0.11794 66.65 753.97 753.48 0.490 0.0074 37.014 3.2744 10
CALLE ANTONIO A45 B10 - B11 0.09756 61.21 753.48 752.98 0.500 0.0082 38.014 2.9447 10
CHECA A46 B10 - B11 0.08249 61.21 753.48 752.98 0.500 0.0082 39.014 2.9447 10
A38 B11 - B12 0.08127 63.11 752.98 754.45 1.470 0.0233 40.014 2.0140 10
A39 B11 - B12 0.11081 63.11 752.98 754.45 1.470 0.0233 41.014 2.0140 10

A50 B13 - B14 0.14240 66.46 750.38 749.61 0.770 0.0116 43.014 2.7424 10
A53 B13 - B14 0.08032 66.46 750.38 749.61 0.770 0.0116 44.014 2.7424 10
CALLE CAPELLAN A59 B14 - B15 0.11515 60.52 749.61 749.98 0.370 0.0061 45.014 3.2636 10
DUAREZ A60 B14 - B15 0.09784 60.52 749.61 749.98 0.370 0.0061 46.014 3.2636 10
A42 B15 - B16 0.11652 70.24 749.98 751.55 1.570 0.0224 47.014 2.2220 10
A64 B15 - B16 0.13513 70.24 749.98 751.55 1.570 0.0224 48.014 2.2220 10

A56 B17 - B18 0.12734 68.39 746.65 745.99 0.660 0.0097 50.014 3.0079 10
A76 B17 - B18 0.09955 68.39 746.65 745.99 0.660 0.0097 51.014 3.0079 10
CALLE A62 B18 - B19 0.09618 59.83 745.99 744.98 1.010 0.0169 52.014 2.1880 10
LAMBAYEQUE A73 B18 - B19 0.07626 59.83 745.99 744.98 1.010 0.0169 53.014 2.1880 10
A70 B19 - B20 0.12159 76.85 744.98 746.78 1.800 0.0234 54.014 2.3389 10
A65 B19 - B20 0.16120 76.85 744.98 746.78 1.800 0.0234 55.014 2.3389 10
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

Para calcular el tiempo de concentracion en cada tramo utilizaremos la ecuacion de KIRPICH, la cual se ilustra a continuacion,

0.385 Si realizamos algunos operaiones la ecuacion quedara de la siguiente forma


 L3 
Tc  0.0195 *  
H  Donde S: Pendiente Longi. (m/m)
L: Longitud (m)
Las intensidades de cada tramo se nostraran acontinuacion, ya que se trabajara con el modelo gumbel que es la que se
ajusta a nuestros datos.

Tr Duración de la lluvia en minutos


tr años 10.00 20.00 30.00 40.00 50.00 60.00
10 357.78 212.74 156.96 126.49 107.00 93.33
25 404.12 240.29 177.29 142.88 120.86 105.41
50 438.50 260.74 192.37 155.03 131.14 114.38
100 472.63 281.03 207.34 167.10 141.35 123.28
Intensidad(mm/h)

CURVAS (I.D.F) NOTA: Se trabajara con el


400 Tr = 10 años
350

300

250

200 TR=
10
150 años

100

50

0
10.0

50.0

60.0
20.0

30.0

40.0

70.0
0.0

TC(Min)
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

Intensidad(mm/h)
CURVAS (I.D.F)
400

350

300

250

200 TR=
10
150 años

100

50

0
10.0

50.0

60.0
20.0

30.0

40.0

70.0
0.0

TC(Min)
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

PENDIENTE

10.36442661
10.36442661
9.361120601
9.361120601
5.585032114
5.585032114
5.994322925
5.994322925
6.934374419
6.934374419
8.501217622
8.501217622

9.836065574
9.836065574
6.275510204
6.275510204
5.689778413
5.689778413
7.174638487
7.174638487
6.271656272
6.271656272
8.497455189
8.497455189
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

8.152173913
8.152173913
5.479677472
5.479677472
6.046107003
6.046107003
5.933544304
5.933544304
8.086689309
8.086689309
6.303394135
6.303394135

3.151483051
3.151483051
4.190036292
4.190036292
5.36015973
5.36015973
5.438859715
5.438859715
7.471804511
7.471804511
6.403415155
6.403415155

3.435912758
3.435912758
1.142564802
1.142564802
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

0.841396719
0.841396719

0.763244538
0.763244538
0.523383421
0.523383421
1.449275362
1.449275362

0.735183796
0.735183796
0.81685999
0.81685999
2.32926636
2.32926636

1.158591634
1.158591634
0.611368143
0.611368143
2.235193622
2.235193622

0.96505337
0.96505337
1.68811633
1.68811633
2.342225114
2.342225114
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

CALCULO DE LOS CAUDALES QUE VAN POR CADA TRAMO


El tiempo de retorno según el RNE para el diseño de cunetas esta dado entre
2 - 10 años, entonces se diseñara con el tiempo de retorno maximo.

C Intensidad Area Q
CALLE, PASAJE TRAMO Q (Lts/s)
Adimens. (mm/hr) (km^2) (m3/s)
P01 - B01 0.83 357.78 0.00030027 0.02477 24.77
P01 - B01 0.83 357.78 0.00030307 0.02500 25.00
B01 - B05 0.83 357.78 0.00086751 0.07156 71.56
B01 - B05 0.83 357.78 0.00085401 0.07045 70.45
B05 - B09 0.83 357.78 0.00132201 0.10905 109.05
CALLE B05 - B09 0.83 357.78 0.00114725 0.09464 94.64
ZARUMILLA B09 - B13 0.83 357.78 0.00066432 0.05480 54.80
B09 - B13 0.83 357.78 0.00066432 0.05480 54.80
B13 - B17 0.83 357.78 0.00080318 0.06625 66.25
B13 - B17 0.83 357.78 0.00064401 0.05312 53.12
B17 - B21 0.83 357.78 0.00067633 0.05579 55.79
B17 - B21 0.83 357.78 0.00077018 0.06353 63.53

P02 - B02 0.83 357.78 0.00035090 0.02895 28.95


P02 - B02 0.83 357.78 0.00034892 0.02878 28.78
B02 - B06 0.83 357.78 0.00106199 0.08760 87.60
B02 - B06 0.83 357.78 0.00096013 0.07920 79.20
B06 - B10 0.83 357.78 0.00165924 0.13687 136.87
B06 - B10 0.83 357.78 0.00138902 0.11458 114.58
CALLE SUCRE
B10 - B14 0.83 357.78 0.00063185 0.05212 52.12
B10 - B14 0.83 357.78 0.00081821 0.06749 67.49
B14 - B18 0.83 357.78 0.00075201 0.06203 62.03
B14 - B18 0.83 357.78 0.00090838 0.07493 74.93
B18 - B22 0.83 357.78 0.00055307 0.04562 45.62
B18 - B22 0.83 357.78 0.00070700 0.05832 58.32

P03 - B03 0.83 357.78 0.00040558 0.03346 33.46


P03 - B03 0.83 357.78 0.00034280 0.02828 28.28
B03 - B07 0.83 357.78 0.00106671 0.08799 87.99
B03 - B07 0.83 357.78 0.00129898 0.10715 107.15
B07 - B11 0.83 357.78 0.00142874 0.11785 117.85
CALLE B07 - B11 0.83 357.78 0.00136917 0.11294 112.94
ALMENDRAS B11 - B15 0.83 357.78 0.00071082 0.05863 58.63
B11 - B15 0.83 357.78 0.00069427 0.05727 57.27
B15 - B19 0.83 357.78 0.00103598 0.08546 85.46
B15 - B19 0.83 357.78 0.00096189 0.07934 79.34
B19 - B23 0.83 357.78 0.00076607 0.06319 63.19
B19 - B23 0.83 357.78 0.00059268 0.04889 48.89
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

P04 - B04 0.83 357.78 0.00039708 0.03275 32.75


P04 - B04 0.83 357.78 0.00035092 0.02895 28.95
B04 - B08 0.83 357.78 0.00083985 0.06928 69.28
B04 - B08 0.83 357.78 0.00104420 0.08613 86.13
B08 - B12 0.83 357.78 0.00096009 0.07920 79.20
CALLE B08 - B12 0.83 357.78 0.00127174 0.10490 104.90
HUAMANTANG
A B12 - B16 0.83 357.78 0.00076003 0.06269 62.69
B12 - B16 0.83 357.78 0.00066710 0.05503 55.03
P16 - B20 0.83 357.78 0.00102131 0.08425 84.25
P16 - B20 0.83 357.78 0.00097789 0.08066 80.66
B20 - B24 0.83 357.78 0.00073000 0.06022 60.22
B20 - B24 0.83 357.78 0.00073559 0.06068 60.68

B01 - B02 0.83 357.78 0.00090548 0.07469 74.69


B01 - B02 0.83 357.78 0.00100035 0.08252 82.52
CALLE VISTA B02 - B03 0.83 357.78 0.00071834 0.05925 59.25
ALEGRE B02 - B03 0.83 357.78 0.00067338 0.05555 55.55
B03 - B04 0.83 357.78 0.00041596 0.03431 34.31
B03 - B04 0.83 357.78 0.00053521 0.04415 44.15

B05 - B06 0.83 357.78 0.00139916 0.11541 115.41


B05 - B06 0.83 357.78 0.00110694 0.09131 91.31
CALLE NICOLAS B06 - B07 0.83 357.78 0.00077867 0.06423 64.23
GUTIERREZ B06 - B07 0.83 357.78 0.00087277 0.07199 71.99
B07 - B08 0.83 357.78 0.00072072 0.05945 59.45
B07 - B08 0.83 357.78 0.00079293 0.06541 65.41

B09 - B10 0.83 357.78 0.00098911 0.08159 81.59


B09 - B10 0.83 357.78 0.00117939 0.09729 97.29
CALLE B10 - B11 0.83 357.78 0.00097562 0.08048 80.48
ANTONIO
CHECA B10 - B11 0.83 357.78 0.00082488 0.06804 68.04
B11 - B12 0.83 357.78 0.00081269 0.06704 67.04
B11 - B12 0.83 357.78 0.00110810 0.09141 91.41

B13 - B14 0.83 357.78 0.00142395 0.11746 117.46


B13 - B14 0.83 357.78 0.00080318 0.06625 66.25
CALLE B14 - B15 0.83 357.78 0.00115154 0.09499 94.99
CAPELLAN
DUAREZ B14 - B15 0.83 357.78 0.00097845 0.08071 80.71
B15 - B16 0.83 357.78 0.00116524 0.09612 96.12
B15 - B16 0.83 357.78 0.00135126 0.11146 111.46

B17 - B18 0.83 357.78 0.00127338 0.10504 105.04


B17 - B18 0.83 357.78 0.00099550 0.08212 82.12
CALLE B18 - B19 0.83 357.78 0.00096179 0.07934 79.34
LAMBAYEQUE B18 - B19 0.83 357.78 0.00076260 0.06291 62.91
B19 - B20 0.83 357.78 0.00121593 0.10030 100.30
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

CALLE
LAMBAYEQUE

B19 - B20 0.83 357.78 0.00161197 0.13297 132.97


Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

DISEÑO DE LAS CUNETAS:


Para el diseño de cunetas se utilizara la ecuacion de MANNING, estas seran en su totaldad
de forma triangular, el RNE en su aporte a saneamiento nos brinda algunas formulaciones
para cada tipo de secciones, en nuestro caso las secciones se consideraron triangulares.

2/ 3
z  z 
Q  315   * S 1/ 2 * y 8/3  
n 1  1  z 
2

Donde:
Q: Caudal en litros/seg.
n: Coef. de rugosidad de Manning
S: Pendiente long. del canal
Z: Valor reciproco de la pendiente Transversal (1:Z)
y: Tirante de agua (m)
T: Ancho superficial (m)

El RNE en su articulo a saneamiento nos brinda algunas pautas con respecto a


cunetas, las cuales se especifican acontinuacion

con respecto al ancho "T"

T: El ancho maximo, de la superficie del agua sobre la pista


sera:
En vias de alto volumen de transito, sera igual al ancho de la berma
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

En vias de bajo volumen de transito; sera igual a la mitad de de la calzada


.
Luego:

Calculo del valor de "Y", para realizar el trasporte de aguas pluviales atraves de la
calzada.
Ancho de la calzada: 9 metros
Ancho Util T: 4.5 metros
Bombeo de la calzada: 2%

Tenemos que el valor de "Y"= 4.5*2%

"Y"= 0.09 metros

El valor de "Z" = T/Y

"Z"= 50
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

CALCULO DE CUNETAS
VERIFICAMOS SI HACEMOS
Qaudal Y= TIRANTE EL DRENAJE A TRAVES DE
REFERENCIA TRAMO Z n pendiente T
(Lts/s) cm CALZADA
P01 - B01 24.77 50.000 0.014 0.104 2.76 Drenar por Calzada 1.380
P01 - B01 25.00 50.000 0.014 0.104 2.77 Drenar por Calzada 1.385
B01 - B05 71.56 50.000 0.014 0.094 4.18 Drenar por Calzada 2.090
B01 - B05 70.45 50.000 0.014 0.094 4.16 Drenar por Calzada 2.080
B05 - B09 109.05 50.000 0.014 0.056 5.40 Drenar por Calzada 2.700
B05 - B09 94.64 50.000 0.014 0.056 5.12 Drenar por Calzada 2.560
CALLE ZARUMILLA
B09 - B13 54.80 50.000 0.014 0.060 4.11 Drenar por Calzada 2.055
B09 - B13 54.80 50.000 0.014 0.060 4.11 Drenar por Calzada 2.055
B13 - B17 66.25 50.000 0.014 0.069 4.30 Drenar por Calzada 2.150
B13 - B17 53.12 50.000 0.014 0.069 3.96 Drenar por Calzada 1.980
B17 - B21 55.79 50.000 0.014 0.085 3.88 Drenar por Calzada 1.940
B17 - B21 63.53 50.000 0.014 0.085 4.07 Drenar por Calzada 2.035

P02 - B02 28.95 50.000 0.014 0.098 2.95 Drenar por Calzada 1.475
P02 - B02 28.78 50.000 0.014 0.098 2.94 Drenar por Calzada 1.470
B02 - B06 87.60 50.000 0.014 0.063 4.86 Drenar por Calzada 2.430
B02 - B06 79.20 50.000 0.014 0.063 4.68 Drenar por Calzada 2.340
B06 - B10 136.87 50.000 0.014 0.057 5.85 Drenar por Calzada 2.925
B06 - B10 114.58 50.000 0.014 0.057 5.48 Drenar por Calzada 2.740
CALLE SUCRE
B10 - B14 52.12 50.000 0.014 0.072 3.90 Drenar por Calzada 1.950
B10 - B14 67.49 50.000 0.014 0.072 4.30 Drenar por Calzada 2.150
B14 - B18 62.03 50.000 0.014 0.063 4.27 Drenar por Calzada 2.135
B14 - B18 74.93 50.000 0.014 0.063 4.59 Drenar por Calzada 2.295
B18 - B22 45.62 50.000 0.014 0.085 3.60 Drenar por Calzada 1.800
B18 - B22 58.32 50.000 0.014 0.085 3.94 Drenar por Calzada 1.970
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
P03 - B03 33.46 50.000 0.014 0.082 3.23 Drenar por Calzada 1.615
P03 - B03 28.28 50.000 0.014 0.082 3.03 Drenar por Calzada 1.515
B03 - B07 87.99 50.000 0.014 0.055 5.00 Drenar por Calzada 2.500
B03 - B07 107.15 50.000 0.014 0.055 5.38 Drenar por Calzada 2.690
B07 - B11 117.85 50.000 0.014 0.060 5.47 Drenar por Calzada 2.735
B07 - B11 112.94 50.000 0.014 0.060 5.39 Drenar por Calzada 2.695
CALLE ALMENDRAS
B11 - B15 58.63 50.000 0.014 0.059 4.23 Drenar por Calzada 2.115
B11 - B15 57.27 50.000 0.014 0.059 4.19 Drenar por Calzada 2.095
B15 - B19 85.46 50.000 0.014 0.081 4.59 Drenar por Calzada 2.295
B15 - B19 79.34 50.000 0.014 0.081 4.47 Drenar por Calzada 2.235
B19 - B23 63.19 50.000 0.014 0.063 4.30 Drenar por Calzada 2.150
B19 - B23 48.89 50.000 0.014 0.063 3.90 Drenar por Calzada 1.950

P04 - B04 32.75 50.000 0.014 0.032 3.83 Drenar por Calzada 1.915
P04 - B04 28.95 50.000 0.014 0.032 3.65 Drenar por Calzada 1.825
B04 - B08 69.28 50.000 0.014 0.042 4.80 Drenar por Calzada 2.400
B04 - B08 86.13 50.000 0.014 0.042 5.21 Drenar por Calzada 2.605
B08 - B12 79.20 50.000 0.014 0.054 4.82 Drenar por Calzada 2.410
CALLE B08 - B12 104.90 50.000 0.014 0.054 5.36 Drenar por Calzada 2.680
HUAMANTANGA B12 - B16 62.69 50.000 0.014 0.054 4.41 Drenar por Calzada 2.205
B12 - B16 55.03 50.000 0.014 0.054 4.20 Drenar por Calzada 2.100
P16 - B20 84.25 50.000 0.014 0.075 4.64 Drenar por Calzada 2.320
P16 - B20 80.66 50.000 0.014 0.075 4.56 Drenar por Calzada 2.280
B20 - B24 60.22 50.000 0.014 0.064 4.21 Drenar por Calzada 2.105
B20 - B24 60.68 50.000 0.014 0.064 4.22 Drenar por Calzada 2.110

B01 - B02 74.69 50.000 0.014 0.034 5.13 Drenar por Calzada 2.565
B01 - B02 82.52 50.000 0.014 0.034 5.32 Drenar por Calzada 2.660
B02 - B03 59.25 50.000 0.014 0.011 5.78 Drenar por Calzada 2.890
CALLE VISTA ALEGRE
B02 - B03 55.55 50.000 0.014 0.011 5.64 Drenar por Calzada 2.820
B03 - B04 34.31 50.000 0.014 0.008 4.99 Drenar por Calzada 2.495
B03 - B04 44.15 50.000 0.014 0.008 5.48 Drenar por Calzada 2.740
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
B05 - B06 115.41 50.000 0.014 0.008 8.00 Drenar por Calzada 4.000
B05 - B06 91.31 50.000 0.014 0.008 7.33 Drenar por Calzada 3.665
B06 - B07 64.23 50.000 0.014 0.005 6.90 Drenar por Calzada 3.450
CALLE NICOLAS
GUTIERREZ 3.600
B06 - B07 71.99 50.000 0.014 0.005 7.20 Drenar por Calzada
B07 - B08 59.45 50.000 0.014 0.014 5.53 Drenar por Calzada 2.765
B07 - B08 65.41 50.000 0.014 0.014 5.74 Drenar por Calzada 2.870

B09 - B10 81.59 50.000 0.014 0.007 7.08 Drenar por Calzada 3.540
B09 - B10 97.29 50.000 0.014 0.007 7.56 Drenar por Calzada 3.780
CALLE ANTONIO B10 - B11 80.48 50.000 0.014 0.008 6.90 Drenar por Calzada 3.450
CHECA B10 - B11 68.04 50.000 0.014 0.008 6.48 Drenar por Calzada 3.240
B11 - B12 67.04 50.000 0.014 0.023 5.30 Drenar por Calzada 2.650
B11 - B12 91.41 50.000 0.014 0.023 5.95 Drenar por Calzada 2.975

B13 - B14 117.46 50.000 0.014 0.012 7.45 Drenar por Calzada 3.725
B13 - B14 66.25 50.000 0.014 0.012 6.01 Drenar por Calzada 3.005
CALLE CAPELLAN B14 - B15 94.99 50.000 0.014 0.006 7.76 Drenar por Calzada 3.880
DUAREZ B14 - B15 80.71 50.000 0.014 0.006 7.30 Drenar por Calzada 3.650
B15 - B16 96.12 50.000 0.014 0.022 6.11 Drenar por Calzada 3.055
B15 - B16 111.46 50.000 0.014 0.022 6.46 Drenar por Calzada 3.230

B17 - B18 105.04 50.000 0.014 0.010 7.39 Drenar por Calzada 3.695
B17 - B18 82.12 50.000 0.014 0.010 6.74 Drenar por Calzada 3.370
B18 - B19 79.34 50.000 0.014 0.017 5.99 Drenar por Calzada 2.995
CALLE LAMBAYEQUE
B18 - B19 62.91 50.000 0.014 0.017 5.49 Drenar por Calzada 2.745
B19 - B20 100.30 50.000 0.014 0.023 6.15 Drenar por Calzada 3.075
B19 - B20 132.97 50.000 0.014 0.023 6.84 Drenar por Calzada 3.420
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

CALCULO DEL TIEMPO DE CONCENTRACION REAL

Longitud (m) tc (min)


REFERENCIA TRAMO Qaudal (Lts/s) Y= TIRANTE cm Z T(m) AREA(m^2) V=Q/A(m/s)
Por kirpich
P01 - B01 24.77 29.91 2.76 50 1.38 0.0190 1.304 0.64 min
P01 - B01 25.00 29.91 2.77 50 1.39 0.0193 1.295 0.64 min
B01 - B05 71.56 58.54 4.18 50 2.09 0.0437 1.638 1.11 min
B01 - B05 70.45 58.54 4.16 50 2.08 0.0433 1.627 1.11 min
B05 - B09 109.05 71.62 5.40 50 2.7 0.0729 1.496 1.59 min
B05 - B09 94.64 71.62 5.12 50 2.56 0.0655 1.445 1.59 min
CALLE ZARUMILLA
B09 - B13 54.80 59.89 4.11 50 2.06 0.0423 1.296 1.34 min
B09 - B13 54.80 59.89 4.11 50 2.06 0.0423 1.296 1.34 min
B13 - B17 66.25 53.79 4.30 50 2.15 0.0462 1.434 1.17 min
B13 - B17 53.12 53.79 3.96 50 1.98 0.0392 1.355 1.17 min
B17 - B21 55.79 45.17 3.88 50 1.94 0.0376 1.484 0.95 min
B17 - B21 63.53 45.17 4.07 50 2.04 0.0415 1.531 0.95 min

P02 - B02 28.95 33.55 2.95 50 1.48 0.0218 1.328 0.71 min
P02 - B02 28.78 33.55 2.94 50 1.47 0.0216 1.332 0.71 min
B02 - B06 87.60 58.80 4.86 50 2.43 0.0590 1.485 1.30 min
B02 - B06 79.20 58.80 4.68 50 2.34 0.0548 1.445 1.30 min
B06 - B10 136.87 69.95 5.85 50 2.93 0.0857 1.597 1.55 min
B06 - B10 114.58 69.95 5.48 50 2.74 0.0751 1.526 1.55 min
CALLE SUCRE
B10 - B14 52.12 53.94 3.90 50 1.95 0.0380 1.372 1.16 min
B10 - B14 67.49 53.94 4.30 50 2.15 0.0462 1.461 1.16 min
B14 - B18 62.03 57.72 4.27 50 2.14 0.0457 1.357 1.28 min
B14 - B18 74.93 57.72 4.59 50 2.3 0.0528 1.419 1.28 min
B18 - B22 45.62 45.19 3.60 50 1.8 0.0324 1.408 0.95 min
B18 - B22 58.32 45.19 3.94 50 1.97 0.0388 1.503 0.95 min
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
P03 - B03 33.46 36.80 3.23 50 1.62 0.0262 1.277 0.82 min
P03 - B03 28.28 36.80 3.03 50 1.52 0.0230 1.230 0.82 min
B03 - B07 87.99 60.77 5.00 50 2.5 0.0625 1.408 1.41 min
B03 - B07 107.15 60.77 5.38 50 2.69 0.0724 1.480 1.41 min
B07 - B11 117.85 68.97 5.47 50 2.74 0.0749 1.573 1.49 min
CALLE B07 - B11 112.94 68.97 5.39 50 2.7 0.0728 1.551 1.49 min
ALMENDRAS B11 - B15 58.63 50.56 4.23 50 2.12 0.0448 1.309 1.18 min
B11 - B15 57.27 50.56 4.19 50 2.1 0.0440 1.302 1.18 min
B15 - B19 85.46 61.83 4.59 50 2.3 0.0528 1.619 1.23 min
B15 - B19 79.34 61.83 4.47 50 2.24 0.0501 1.584 1.23 min
B19 - B23 63.19 43.31 4.30 50 2.15 0.0462 1.368 1.03 min
B19 - B23 48.89 43.31 3.90 50 1.95 0.0380 1.287 1.03 min

P04 - B04 32.75 37.76 3.83 50 1.92 0.0368 0.890 1.21 min
P04 - B04 28.95 37.76 3.65 50 1.83 0.0334 0.867 1.21 min
B04 - B08 69.28 60.62 4.80 50 2.4 0.0576 1.203 1.56 min
B04 - B08 86.13 60.62 5.21 50 2.61 0.0680 1.267 1.56 min
B08 - B12 79.20 65.11 4.82 50 2.41 0.0581 1.363 1.50 min
CALLE B08 - B12 104.90 65.11 5.36 50 2.68 0.0718 1.461 1.50 min
HUAMANTANGA B12 - B16 62.69 53.32 4.41 50 2.21 0.0487 1.287 1.28 min
B12 - B16 55.03 53.32 4.20 50 2.1 0.0441 1.248 1.28 min
P16 - B20 84.25 63.84 4.64 50 2.32 0.0538 1.566 1.30 min
P16 - B20 80.66 63.84 4.56 50 2.28 0.0520 1.551 1.30 min
B20 - B24 60.22 46.85 4.21 50 2.11 0.0444 1.356 1.08 min
B20 - B24 60.68 46.85 4.22 50 2.11 0.0445 1.364 1.08 min

B01 - B02 74.69 66.94 5.13 50 2.57 0.0659 1.133 1.81 min
B01 - B02 82.52 66.94 5.32 50 2.66 0.0708 1.166 1.81 min
CALLE VISTA B02 - B03 59.25 58.64 5.78 50 2.89 0.0835 0.710 2.50 min
ALEGRE B02 - B03 55.55 58.64 5.64 50 2.82 0.0795 0.699 2.50 min
B03 - B04 34.31 47.54 4.99 50 2.5 0.0624 0.550 2.40 min
B03 - B04 44.15 47.54 5.48 50 2.74 0.0751 0.588 2.40 min
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
B05 - B06 115.41 66.82 8.00 50 4 0.1600 0.721 3.23 min
B05 - B06 91.31 66.82 7.33 50 3.67 0.1345 0.679 3.23 min
B06 - B07 64.23 59.23 6.90 50 3.45 0.1190 0.540 3.41 min
CALLE NICOLAS
GUTIERREZ
B06 - B07 71.99 59.23 7.20 50 3.6 0.1296 0.555 3.41 min
B07 - B08 59.45 54.51 5.53 50 2.77 0.0766 0.776 2.16 min
B07 - B08 65.41 54.51 5.74 50 2.87 0.0824 0.794 2.16 min

B09 - B10 81.59 66.65 7.08 50 3.54 0.1253 0.651 3.27 min
B09 - B10 97.29 66.65 7.56 50 3.78 0.1429 0.681 3.27 min
CALLE ANTONIO B10 - B11 80.48 61.21 6.90 50 3.45 0.1190 0.676 2.94 min
CHECA B10 - B11 68.04 61.21 6.48 50 3.24 0.1050 0.648 2.94 min
B11 - B12 67.04 63.11 5.30 50 2.65 0.0702 0.955 2.01 min
B11 - B12 91.41 63.11 5.95 50 2.98 0.0887 1.031 2.01 min

B13 - B14 117.46 66.46 7.45 50 3.73 0.1389 0.846 2.74 min
B13 - B14 66.25 66.46 6.01 50 3.01 0.0905 0.732 2.74 min
CALLE CAPELLAN B14 - B15 94.99 60.52 7.76 50 3.88 0.1505 0.631 3.26 min
DUAREZ B14 - B15 80.71 60.52 7.30 50 3.65 0.1332 0.606 3.26 min
B15 - B16 96.12 70.24 6.11 50 3.06 0.0935 1.028 2.22 min
B15 - B16 111.46 70.24 6.46 50 3.23 0.1043 1.069 2.22 min

B17 - B18 105.04 68.39 7.39 50 3.7 0.1367 0.768 3.01 min
B17 - B18 82.12 68.39 6.74 50 3.37 0.1136 0.723 3.01 min
CALLE B18 - B19 79.34 59.83 5.99 50 3 0.0899 0.883 2.19 min
LAMBAYEQUE B18 - B19 62.91 59.83 5.49 50 2.75 0.0755 0.833 2.19 min
B19 - B20 100.30 76.85 6.15 50 3.08 0.0947 1.059 2.34 min
B19 - B20 132.97 76.85 6.84 50 3.42 0.1170 1.136 2.34 min
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

TIEMPO DE CONCENTRACION REAL

tc (min)

0.38
0.38
0.60
0.60
0.80
0.83
0.77
0.77
0.63
0.66
0.51
0.49

0.42
0.42
0.66
0.68
0.73
0.76
0.66
0.62
0.71
0.68
0.53
0.50
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
0.48
0.50
0.72
0.68
0.73
0.74
0.64
0.65
0.64
0.65
0.53
0.56

0.71
0.73
0.84
0.80
0.80
0.74
0.69
0.71
0.68
0.69
0.58
0.57

0.98
0.96
1.38
1.40
1.44
1.35
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
1.54
1.64
1.83

1.78
1.17
1.14

1.71
1.63
1.51
1.57
1.10
1.02

1.31
1.51
1.60
1.66
1.14
1.10

1.48
1.58
1.13
1.20
1.21
1.13
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

DISEÑO DEL ALCANTARILLADO

Para el diseño del alcantarillado se tomará en cuenta los tiempos de concentración máximos máximos para cada caso
Según reglamento no siendo este Tc < 10 min.

3/8
�3.21* Q * n �
q  � 0.5 �
� s �

n: coeficiente rugocidad de la alcantarilla:


Q: Caudal de diseño
S: Pendiente m/m.

AREA
PENDIENTE( DRENADA(K Intensidad Qdi Diametro (m) D comercial Qnuevo v=Q/A
TUBERIA LONG. (m) SUMA C*A tc (minutos) Area tiempo (seg) tiempo (min)
m/m) (mm/hora) (m^3/seg) (m) (m^3/seg) (m/seg)
m2)

B01-B05 58.54 0.073 0.001 0.000501 10.00 357.78 0.049809 0.146068 0.4 0.731111 0.125664 5.818 10.06189 0.168
B02-B06 58.80 0.062 0.003 0.002163 10.00 357.78 0.215108 0.260761 0.4 0.673235 0.125664 5.357 10.9754 0.183
B03-B07 60.77 0.052 0.002 0.001826 10.00 357.78 0.181654 0.252602 0.4 0.618832 0.125664 4.925 12.34033 0.206
B04-B08 60.62 0.040 0.002 0.00141 10.00 357.78 0.140274 0.240803 0.4 0.542881 0.125664 4.320 14.03205 0.234
B05-B06 66.82 0.008 0.002 0.00193 10.00 357.78 0.191928 0.36457 0.4 0.245781 0.125664 1.956 34.16392 0.569
B06-B07 59.23 0.004 0.009 0.007851 10.00 357.78 0.780860 0.706754 0.75 0.914861 0.441786 2.071 28.60218 0.477
B07-B08 54.51 0.006 0.017 0.014268 10.00 357.78 1.419104 0.810223 0.85 1.612571 0.56745 2.842 19.18161 0.320
B08- 0.826458
43.22 0.008 0.021 0.017242 10.00 357.78 1.714914 0.85 1.848295 0.56745 3.257 13.2691 0.221
EM01
EM01- 0.004 0.021 0.017242 10.00 357.78 1.714914 0.968219 1 1.869159 0.785398 2.380 43.41803 0.724
103.33
NAME
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

B09-B13 59.89 0.058 0.002 0.002049 10.00 357.78 0.203848 0.25859 0.4 0.652384 0.125664 5.192 11.53616 0.192
B13-B17 53.79 0.065 0.004 0.003152 10.00 357.78 0.313533 0.297809 0.4 0.68856 0.125664 5.479 9.816799 0.164
B17-B21 45.16 0.070 0.005 0.004353 10.00 357.78 0.433005 0.33126 0.4 0.71593 0.125664 5.697 7.926714 0.132
B10-B14 53.94 0.069 0.005 0.00433 10.00 357.78 0.430665 0.331706 0.4 0.709509 0.125664 5.646 9.553507 0.159
B14-B18 57.72 0.052 0.011 0.00915 10.00 357.78 0.910074 0.462746 0.5 1.118794 0.19635 5.698 10.12992 0.169
B18-B22 45.19 0.047 0.015 0.012411 10.00 357.78 1.234452 0.528718 0.55 1.371443 0.237583 5.772 7.828524 0.130
B11-B15 50.56 0.066 0.007 0.005411 10.00 357.78 0.538188 0.363392 0.4 0.695174 0.125664 5.532 9.139519 0.152
B15-B19 61.83 0.062 0.010 0.008666 10.00 357.78 0.861932 0.438701 0.45 0.92241 0.159043 5.800 10.6608 0.178
B19-B23 43.31 0.043 0.017 0.014102 10.00 357.78 1.402675 0.563992 0.6 1.65437 0.282743 5.851 7.401982 0.123
B12-B16 53.32 0.053 0.002 0.001852 10.00 357.78 0.184247 0.252982 0.4 0.625159 0.125664 4.975 10.71789 0.179
B16-B20 63.84 0.072 0.004 0.003373 10.00 357.78 0.335515 0.29965 0.4 0.724824 0.125664 5.768 11.06803 0.184
B20-B24 46.85 0.061 0.006 0.00459 10.00 357.78 0.456506 0.34683 0.4 0.667775 0.125664 5.314 8.816358 0.147
B24-B25 13.22 0.065 0.007 0.005806 10.00 357.78 0.577498 0.374196 0.4 0.689888 0.125664 5.490 2.408036 0.040
B21-B22 67.11 0.009 0.007 0.005554 10.00 357.78 0.552420 0.537447 0.55 0.587501 0.237583 2.473 27.13902 0.452
B22-B23 59.59 0.002 0.023 0.019011 10.00 357.78 1.890896 1.121364 1.5 4.107586 1.767146 2.324 25.63652 0.427
B23-B25 87.61 0.004 0.041 0.034241 10.00 357.78 3.405742 1.242762 1.5 5.624544 1.767146 3.183 27.52573 0.459
B25- 175.79 0.0041 0.048 0.040047 10.00 357.78 3.983239 1.296078 1.5 5.881168 1.767146 3.328 52.82056 0.880
NAME
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

0.067 7.3
0.050 6.19
0.042 5.23
0.032 4.025
0.007 0.825
0.0032 0.4
0.005 0.6375
0.007 0.8375

0.36
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

0.047 5.8125
0.052 6.475
0.066 7
0.055 6.875
0.0477 5.2
0.0469 4.7
0.046 6.6
0.054 6.2
0.0427 4.3
0.043 5.3375
0.057 7.175
0.049 6.09
0.054 6.5
0.0069 0.8625
0.0016 0.2
0.003 0.375

0.41
DISEÑO DE SUMIDERO TIPO SOLERA

se diseñara un sumidero tipo solera para las pendientes menores a 3%

1 - TIPO VENTANA SIN DEPRESION

DATOS:
QD= - m3/s (maximo caudal calle iquitos)
QD(= - lt/s
n= 0.014
Sx= 2.340
So= 0.020

Aplicando la fórmula de Izzard


 z  
Q  0.375
 
S 01/2 y 8/3

Sx * n 

Yo= 0.00 cm
Yo= 0.00 m
determinacion de la longitud de la ventana

valores de k:
Sx 8% 4% 2%
k 0.23 0.2 0.2

para nuestro caso K lo encontraremos extrapolando debido a que Sx= 10%; con la tabla anterior asi tenemos
k= 0.245

0,6*Q …….(3)
L=
K*Ya*(Ya*A)^(1/2)
reemplazando los valores en la ecuacion (3) tenemos:

L= #DIV/0! m OK
z  

S 01/ 2 y 8/3
x * n

%; con la tabla anterior asi tenemos:


 * ( R ) * ( So )
Universidad Nacional De Cajamarca - Sede Jaén

Ancho de la calle
Diseñar el sumidero para el caudal anterior

Area y pavimento de concreto


Pendiente longitudinal

Pendiente transversal
Altura de Acera

Reemplazando valores

El area de flujo será:

pero:

Reemplazando valores
133
Q=

YA
0.133 m3/s

=
0.00175

T=

T=
7.0
=

100
132.97 l/s

 z  1/ 2 8 / 3
Q  0 .00175 S 0 y
 Sx * n 

0.014 0.02342

7.0
0.02

7.0 3.477
A

2
50


9
2

=
Ingenieria de Drenaje

Suponemos que todo el caudal anterior solamente va por las cunetas sin permitir inundacion
para poder diseñar un sumidero de ventana sin dpresion por contar la calle en este punto
con una pendiente suave.
Calcular la longitud del sumidero para captar el 30% del caudal anterior

0.014
2.3422251

10

Y
S
A

X
*
n
%
m
%
cm

T
2

0.1209
Donde:

0.02

347.70

m2

La velocidad del flujo será


Q
V A  A

A A

VA= 307 * 10^-3


= 2.539
0.121
2n
Universidad Nacional De Cajamarca - Sede Jaén

Para k = 0.20 por tener una pendiente transversal de del 1%

Sabiendo que QI= 0.7QA

Reemplazamos valores
L 

L
0 .2 *

L=
QI

8 .8
100
1.74
Ingenieria de Drenaje

K *YA g *YA

0 .3 * 307 * 10  3

9 .81 *
8 .8
100
m

ll/s * 1/2

1/2

1/2
( ) *

l/s
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

l/s
1/2
( ) *

l/s

1/2
( ) *

l/s
1/2
( ) *
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

( ) *

l/s

1/2
( ) *

l/s
1/2
( ) *

l/s
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

1/2
( ) *

l/s
1/2
( ) *

l/s
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

1/2
( ) *

l/s
1/2
( ) *

l/s
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

1/2
( ) *
*
cm
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

sumidero para el caudal anterior

nterior solamente va por las cunetas sin permitir inundacion


de ventana sin dpresion por contar la calle en este punto

Q: en (l/s)
"Y" en (cm)

cm = 3.48 m

m/s
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

1/2 * l/s 8/3


8/3

1/2

1/2 8/3
*
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

1/2 8/3
*

1/2 8/3
*

1/2 8/3
*
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

1/2 8/3
*

1/2 8/3
*
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

1/2 8/3
*

1/2 8/3
*
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

1/2 8/3
*

1/2 8/3
*
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

1/2 8/3
*
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

ARRASTRE DE SEDIMENTOS

Caudal m3/s Q 0.28


Area Hidraulica m2 A 0.47
Perímetro mojado m P 1.99
Radio Hidráulico R 0.2361809
Altura Y 0.35
Ancho medio Am=A/Y 1.34285714
Velocidad media Vm=Q/A 0.59259431
gasto liquido unitario Q/Am 0.20740801
Pendiente S 0.001
t0 PeXRXS 0.2361809

Peso específico Kg-f/m3 Pe 1000


Densidad Kg/m3 d 1000
Viscosidad cinematica vc 0.000001
D (Pe sol-Pe)/( 1.6
Peso Específico sólido Kgf/m3 Pe sol. 2600
Densidad Kg/m3 D 2600

Desviación estándar mm 1.276


Dm mm 0.42
d40 mm 4.74
d50 mm
d65 mm 15.76
d90 mm 4

MEYER PETER MULLER


n 0.02038946
n' 0.01532392
t* 0.35145968
gB 0.12448135
GB 0.16716067

3/ 2
 n'  3 / 2 RS 
g B  8 s Dm g   
1/ 2 1/ 2
 0.047  kg  f / s * m
 n   n Dm 

2/3 1/ 6
RH * S 1/ 2  D 
n n'   90 
Vm  1000 

En una hora, el flujo habrà transportado :


Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

Según Peter Muller:

Calculo de peso de sedimentos


0.17 Kg/s
PESO= 2.16kg/S*3600S
601.78 Kg

Expresamos en Tn:
0.60 Tn.

Entonces el volumen de sedimentos se determina por:

peso 7770.09kg
v 
peso especifico 2600kg / m3

V= 0.23 m3
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

Calculo Eroción General

Metodo: Lacey

Ds = 1.4859*(q2/f) 1/3
f=Raiz(dm) (en cauce)
dm= en mm
q = caudal unitario
Ds= Nivel de agua erocionado

Datos:
Caudal: 0.279 m3/s tr= 25 años
Ancho: 1.343 m
Diametro medio: 0.42 mm.
Nivel de agua : 0.35 msnm
Cota de Fondo sin eroción : 0.00 msnm

Resultados

qunit = 0.20740801 m3/s/m


F= raiz(dm) = 1.134
DS= 1.4859*(q^2/f)^1/3 = 0.499 m.
Cota de fondo erocionado = -0.149 msnm.
Altura de erociòn = 0.149 m
Universidad Nacional De Cajamarca - Sede Jaén Ingenieria de Drenaje

SEDIMENTOS EN SUSPENSION

Calculo de sedimentos en suspenciòn

D = diametro medio = 0.42 mm.


Q = Caudal = 0.279 m3/s T = 25 AÑOS
A = area = 0.470 m2
P = Perimetro = 1.990 m.
S = pendiente = 0.001
R = radio hidraulico A/P = 0.236
w = velocidad caida= según cuadro 0.05547 m/s
u= viscocidad cinematica = 0.000001 kg/m3
U*= velocidad de corte = (gRS)0.5= 0.048
Ucr = 2.05 * w = 0.1137135 U*xD/u = 20216.51
V= 0.593
 wD  U   wd  U   U s U ct * s 
log ct  5.435  0.286 log    0.457 log    1.799  0.49 log    0.314 log   * log   
 v  w  v  w  w w 
logCt = 4.147823886

Ct = 14054.77463 ppm

En una hora, el flujo habrà transportado :

14.05477463 gr/l
4.11058703 gr/l*100m3/s*h
4.110587703 gr/l*25*1000 l/s*3600s
1264929717 gr.
1264.929717 Tn

También podría gustarte