Está en la página 1de 2

U V / V I S

Application Configurations
LAMBDA 25/35/45 UV/Vis Spectrophotometers

S P E C T R O P H O T O M E T R Y
Overview
Use this document as a quick reference guide for quoting some common applications and industry-specific
configurations. In each case, a PC should be either ordered from PerkinElmer, or must be supplied by the
customer. All versions of UV WinLab™ software run on Windows® 2000 or XP. An RS-232 cable to connect
to the PC is included with the instrument.

1. LAMBDA 35 Routine Reflectometry System


For routine reflectance measurements on powders, packaging and other solid samples.
L6020064 LAMBDA™ 35 with UV WinLab V5 L6100046 Color methods software (optional)
C6950014 50 mm integrating sphere PELA9018 Set of color standards (optional)
PELA9040 Powder holder (optional)

2. LAMBDA 25 Single-Cell DNA Melting System


For DNA conformation studies in molecular biology research groups and academia.
L60000BB LAMBDA 25 with UV WinLab V2.85 B0080819 Reference cell-holder (water thermostatted)
L6310010 PTP-1 Peltier system B0185227 Temperature measurement kit
L6100044 TempLab software L6000500 Accessory PCB

3. LAMBDA 25 Multi-Cell DNA Melting System


For higher throughput DNA melting studies in busier labs.
L60000BB LAMBDA 25 with UV WinLab V2.85 L6100044 TempLab software
L6310011 PTP-6 Peltier system B0185227 Temperature measurement kit
B2000186 Linear cell transporter L6000500 Accessory PCB

4. LAMBDA 25 Autosampling System


For very high throughput unattended liquid sampling – can be configured to analyze up to 180 samples.
L6020060 LAMBDA 25 with UV WinLab V5 B0631087 10 mm quartz flowcell
B3141050 AS93 plus liquid autosampler
For sample tray and rack configurations and sample vessel options see LAMBDA 25/35/45 product description list.

5. LAMBDA 25 Autosampling System for Pharmaceuticals (21 CFR Part 11 Compliant)


For very high throughput unattended liquid sampling for Pharmaceutical QA and product development labs.
L6020020 LAMBDA 25 with UV WinLab V5 ES B0631087 10 mm quartz flowcell
B3141050 AS93 plus liquid autosampler
For sample tray and rack configurations and sample vessel options see LAMBDA 25/35/45 product description list.

6. LAMBDA 25 Environmental System


For analysis of cations, anions and other pollutants in waste and drinking water.
L6020060 LAMBDA 25 with UV WinLab V5 B0500952 Test tube holder
B0080821 Long pathlength cell holder

7. LAMBDA 25 Teaching and Biosciences System


A simple, low-cost configuration for teaching laboratories in schools, colleges and universities. For biosciences
laboratories, UV WinLab V2.85 contains a suite of standard DNA, RNA, oligonucleotide, protein and enzyme
kinetics methods.
L60000BB LAMBDA 25 with UV WinLabV2.85 B0080819 Cell-holder (water thermostatted)

8. LAMBDA 25 Industrial QA System


For quality and impurity analyses on raw materials, intermediates and final products.
L6020060 LAMBDA 25 with UV WinLab V5 B0507805 Set of calibrated reference materials (optional)
B0631009 Pair of 1 cm quartz cells

Company Confidential: For Internal Use Only


9. LAMBDA 35 Pharmaceutical QA System
For quality and impurity analyses on raw materials, intermediates and final products in the pharmaceutical and other
FDA-regulated industries.
L6020066 LAMBDA 35 with UV WinLab V5 ES B0507805 Set of calibrated reference materials (optional)
B0631009 Pair of 1 cm quartz cells

10. LAMBDA 25 Multi-Cell Kinetics System (1)


For kinetics and similar analyses between 25 to 45 ˚C. Ideal for labs that need to switch rapidly between temperatures.
L60000BB LAMBDA 25 with UV WinLab V2.85 L6000500 Accessory PCB
N1010566 9+1 Routine Peltier system

11. LAMBDA 25 Multi-Cell Kinetics System (2)


For kinetics and similar analyses between 20 to 60 ˚C. The 8+1 cell-changer is water-thermostatted.
L60000BB LAMBDA 25 with UV WinLab V2.85 N1010567 8+1 Cell changer kit

12. LAMBDA 35 Dipping Optrode Fiber Optics System


Ideal for in-situ liquid analysis where the sample cannot be brought to the spectrophotometer or removed from the vessel.
L6000064 LAMBDA 35 with UV WinLab V5 N1016074 Light shield
N1016070 Dipping optrode N1016071 Probe tip (1 cm path length)
B0509546 Transfer optic

13. LAMBDA 25 Sipper System


Convenient liquid analysis for a wide range of liquid samples.
L6020060 LAMBDA 25 with UV WinLab V5 B0631084 Flow-through cell 1 cm
B2190036 Peristaltic sipper

Additional Options
Water Thermostatting
For configurations 2 and 3, water circulation is required to remove heat from the Peltier block. For these, or any other configurations
which require thermostatting, offer one of the following if the customer does not already have a suitable water bath:
• B0080171 Water Circulator (230V, 50 Hz) • N1015158 Peltier Fluid Circulator
• L6310205 Water Circulator (120V, 60 Hz)

Lamps
With any configuration, offer the following spare lamps. Each is pre-aligned and can be easily changed by the user.
• B0114620 Tungsten-Halogen Lamp • B0160917 Deuterium Lamp

Calibrated Reference Materials


The following calibration materials provide verification of the performance of the spectrophotometer. All materials are certified
traceable to NIST primary reference material and include a calibration certificate.
• B0507805 Photometric and wavelength accuracy • B2500099 Stray light solutions reference materials set
reference material set • B2500100 Pharmacopoeia solutions reference material set

Spectroscopy Cells
Refer to the consumables catalog or www.perkinelmer.com/uvsupplies for a comprehensive listing of glass and quartz standard and
semi-micro cells.

Company Confidential: For Internal Use Only


007409_02