1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF TITLE 24 OF THE CALIFORNIA CODE OF SYMBOL ABBR DESCRIPTION ABBR DESCRIPTION ABBR DESCRIPTION DWG. NO. DESCRIPTION
REGULATIONS (C.C.R.), 2010 CPC.
AB.C ABOVE CEILING KW KILOWATTS P0.1 PLUMBING LEGEND AND NOTES
DETAIL NUMBER
2. ALL SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, FEDERAL DRAWING NUMBER AC AIR CONDITIONING LAB LABORATORY P2.0 PLUMBING WASTE & VENT
AND STATE CODES AND ORDINANCES, AND SHALL MEET ALL REQUIREMENTS OF ALL AUTHORITIES HAVING AFF ABOVE FINISHED FLOOR LBS POUNDS
JURISDICTION. P2.1 PLUMBING DOMESTIC WATER AND GAS
AG ABOVE GRADE LVL LEVEL
SECTION NUMBER P2.2 MECHANICAL ROOM PIPING DETAIL
3. DRAWINGS SHOWING THE LOCATIONS OF PLUMBING EQUIPMENT, PIPING, ETC. ARE DIAGRAMMATIC AND JOB DRAWING NUMBER AMP AMPERES LWT LEAVING WATER TEMPERATURE
CONDITIONS WILL NOT ALWAYS PERMIT THEIR INSTALLATION ON THE LOCATIONS SHOWN. THE PLUMBING P3.0 PLUMBING ISOMETRICS
ARCH ARCHITECTURAL MAX MAXIMUM
DRAWINGS SHOW THE GENERAL ARRANGEMENTS OF EQUIPMENT, PIPING, ETC. AND SHALL BE FOLLOWED
AS CLOSELY AS ACTUAL BUILDING CONSTRUCTION AND THE WORK OF OTHER TRADES WILL PERMIT. THE BFF BELOW FINISHED FLOOR MBH THOUSAND BTU PER HOUR
ARCHITECTURAL DRAWINGS SHALL BE PART OF THE WORK INSOFAR AS THESE DRAWINGS FURNISH THE BG BELOW GRADE MIN MINIMUM
CONTRACTOR WITH INFORMATION RELATING TO DESIGN AND CONSTRUCTION OF THE BUILDING. BHP BRAKE HORSEPOWER MISC MISCELLANEOUS
BLDG BUILDING N/A NOT APPLICABLE
4. FURNISH AND INSTALL ANY INCIDENTAL WORK NOT SHOWN OR SPECIFIED WHICH ARE NECESSARY TO
PROVIDE A COMPLETE AND WORKABLE SYSTEM. BOF BOTTOM OF FOOTING NC NORMALLY CLOSED
BTU BRITISH THERMAL UNIT NIC NOT IN CONTRACT
5. PRIOR TO SUBMISSION OF BID, REVIEW FULL SET OF NEW CONSTRUCTION DRAWINGS (INCLUDING ALL
BTUH BRITISH THERMAL UNIT PER HOUR NIPW NOT IN PLUMBING WORK
OTHER TRADES). INCLUDE ANY ADDITIONAL PIPE OFF-SETS THAT ARE NOT CURRENTLY SHOWN ON
DRAWINGS BUT MAY BE REQUIRED TO CLEAR STRUCTURE, FINISHES OR WORK OF OTHER TRADES. NO CFH CUBIC FEET PER HOUR NO NORMALLY OPEN
16. KEEP ALL PLUMBING PIPING AS HIGH AS POSSIBLE TO THE STRUCTURE ABOVE AND OFFSET PIPING AS NOTE: NOT ALL SYMBOLS OR ABBREVIATIONS APPLY NOTE: NOT ALL SYMBOLS OR ABBREVIATIONS APPLY
REQUIRED.
18. CHANGES IN THE DIRECTION OF DRAINAGE FLOW SHALL BE PER CALIFORNIA PLUMBING CODE.
19. ALL SANITARY VENTS SHALL TERMINATE AT LEAST 6" ABOVE ROOF AND AT LEAST 12" FROM ANY VERTICAL
SURFACE. PROVIDE MINIMUM 10' CLEARANCE FROM VENT TERMINATIONS TO OUTSIDE AIR INLETS OR
OPENINGS IN THE BUILDING.
20. ALL PIPING PENETRATION THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH UL-LISTED AND
CALIFORNIA FIRE MARSHAL LISTED SEALANTS. SEE ARCHITECTURAL DRAWINGS FOR ALL LOCATIONS.
23. SANITARY SEWER AND VENT PIPING SHALL BE ABS, COPPER OR CAST IRON.
25. NATURAL GAS PIPING ABOVE GROUND SHALL BE SCHEDULE 40 BLACK STEEL.
2-WAY COTG
(IE=18" BFF)
HB-1
1" CW 1/2" CW
G G
WB-1 3/4" G
3" SS 3/4" HW
3"
2-BEDROOM ROOF PLAN 2-BEDROOM SECOND FLOOR PLAN 2-BEDROOM FIRST FLOOR PLAN
CLOTHES DRYER (35 MBH) 3/4 HW RISER BETWEEN 1ST AND 2ND FLOOR.
FT G
47 FURNACE IN ATTIC. REFER TO MECHANICAL PLANS.
3/4" SS RISER UP TO ATTIC. PROVIDE AIR GAP FITTING (MIN 1" CLEARANCE) FOR CONNECTION
G TO CONDENSATE DRAIN.
NATURAL GAS METER RECESSED IN WALL. COORDINATE EXACT LOCATION WITH PG&E.
PROVIDE DIRT LEG WITH REMOVABLE CAP AT NATURAL GAS CONNECTIONS TO EQUIPMENT.
METER
3"SS
1"CW
HB-1
G G
G
2" SS AB.C
1-1/4" G
G
WB-1
3/4"HW
G
2" VTR
WCO (TYP)
L-1 1"CW 1"HW
KS-1
G
3/4"CW 3/4"HW 3/4"CW
3/4"HW
L-1 T-1
2" VTR BT-1
2" VTR 3/4"CW T-1 3/4"CW 3"SS 1"CW IWH-2
3"SS
2" VTR COTG
HB-1
3-BEDROOM ROOF PLAN 3-BEDROOM SECOND FLOOR PLAN 3-BEDROOM FIRST FLOOR PLAN
3/4" SS RISER UP TO ATTIC. PROVIDE AIR GAP FITTING (MIN 1" CLEARANCE) FOR CONNECTION
TO CONDENSATE DRAIN.
FT
34 3/4" G RISER BETWEEN 1ST AND 2ND FLOOR.
G
PROVIDE HW AND SS CONNECTION FROM KS-1 TO DISHWASHER WITH AIR GAP FITTING.
HB-1
G G
3"SS
1" CW AB.C
G
1-1/4" G AB.C
G
G
1"CW AB.C
WB-1 3/4" CW AB.C KS-1
3/4" CW
3/4"HW AB.C
2" VTR 1""HW AB.C 1" HW 3/4"HW AB.C
2" SS BT-1 1"CW AB.C
BT-1
3/4"CW WCO (TYP)
AB.C T-1
2" VTR
2" VTR 2" VTR T-1 L-1 3" SS
L-1 G
1/2" G 2"SS
AB.C IWH-2 1-1/4" G AB.C
HB-1
3"SS
COTG (TYP)
4-BEDROOM ROOF PLAN 4-BEDROOM SECOND FLOOR PLAN 4-BEDROOM FIRST FLOOR PLAN
COORDINATE LOCATION (AND SLOPE IF REQUIRED) OF ALL PIPE ABOVE FIRST FLOOR CEILING 3" SS DROP BETWEEN 1ST AND 2ND FLOOR.
WITH STRUCTURAL REQUIREMENTS OF FLOOR FRAMING.
T
8F 2" VENT RISER BETWEEN 1ST AND 2ND FLOOR.
G
IWH-2 3/4" CW RISER BETWEEN 1ST AND 2ND FLOOR.
G
G (199 MBH)
16 FT
G CLOTHES 3/4" SS RISER UP TO ATTIC. PROVIDE AIR GAP FITTING (MIN 1" CLEARANCE) FOR CONNECTION
FT DRYER TO CONDENSATE DRAIN.
43 G (35 MBH)
3/4" G RISER BETWEEN 1ST AND 2ND FLOOR.
METER PROVIDE DIRT LEG WITH REMOVABLE CAP AT NATURAL GAS CONNECTIONS TO EQUIPMENT.
WALL CLEANOUT.
2" SS BFF.
VTR VTR
VTR CW RISER BETWEEN 1ST AND 2ND FLOOR.
BT-1
HW RISER BETWEEN 1ST AND 2ND FLOOR.
L-1 L-1
T-1
L-1
SANITARY WASTE & VENT ISOMETRIC 4-BEDROOM SANITARY WASTE & VENT ISOMETRIC 3-BEDROOM SANITARY WASTE & VENT ISOMETRIC 2-BEDROOM
IWH-1
BT-1
WB-1
T-1
BT-1
IWH-2
IWH-2 L-1
WB-1 L-1
KS-1 T-1 BT-1
HB-1
HB-1
T-1
WB-1 T-1
KS-1
HB-1
L-1
L-1
CW LINE INTO BUILDING L-1
BT-1
HB-1
HB-1
CW LINE INTO BUILDING
HB-1
CW LINE INTO BUILDING
T-1
COLD & HOT WATER ISOMETRIC 4-BEDROOM COLD & HOT WATER ISOMETRIC 3-BEDROOM COLD & HOT WATER ISOMETRIC 2-BEDROOM