Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Diketahui
SG = 0.9469
Visco = 2.62 cP
ρ = 946.9 kg/m3 59.12974 lb/ft3
Q = 1000 m3/H 35287.55 ft3/H 9.802098 ft3/s
Fitting Cl
Enterance 0.5
Exit 1
Elbow 90 0.2 (Long Radius 90 with flange)
Elbow 45 0.2 (long Radius 45 with flange)
BAGIAN SUCTION
Menghitung P1
P1 = ρ.g. H
ρ massa jenis = 946.9 kg/m3
g gravitasi = 9.8 m/s2
H ketinggian liquid Tangki
H pada tangki A diketahui
HHLL = 17000 mm
LLLL = 1500 mm
Tinggi Suction Pompa 1300 mm
tinggi pipa ke permukaan pondasi 300 mm
H = 16700 mm 16.7 m 54.79003 ft
Ve= C
ρ^0.5
Hf = 23 ft
14.0208 7.0104 m 14.0208
L 50 m 164.042 ft
Le 2 elbow 90 LR 14.0208 m 46 ft
Ltotal 64.0208 m 210.042 ft L/D 133.9908 m/m
iD = 0.4778 m 1.567585 ft 133.9908 ft/ft
2g = 19.6 m/s2 64.30446 ft/s2 64.34
v^2 = 25.8210569922 ft/s 7.870258 m/s
NRe
Nre 2.68E+05
Hf= 1.3450792331 ft
Hl
Cl yang digunakan
Enterance 0.5
Elbow 0.2
Elbow 0.2
Total Cl 0.9
Hl 0.3613894058
Atau
HL = Hf+Hl
HL = 1.7064686389
ΔP = ρ .HL
ΔP 100.9030446149 lb/ft2
0.0476807852 atm 0.700908 psi
Menghitung NPSH Available
Tinggi level cairan minimal (LLLL) = 1500 mm 4.92126 ft
Tinggi suction pompa = 1300 mm 4.265092 ft
Tekanan didalam tanki (Pa) = 14.7 psi
Menghitung LHP
LHP = Q ρ g h / (3.6.10^6)
LHP= 135.8419489845 kW
hs= 819.4176 ft
n 2800 rpm
BAGIAN DISCHARGE
Mmenghitung P2
P1 = ρ.g. H
ρ massa jenis
g gravitasi = 9.8 m/s2
H ketinggian liquid Tangki
H pada tangki A diketahui
HHLL = 20000 mm
LLLL = 2000 mm
Tinggi Discharge Pompa 1500 mm
tinggi pipa ke permukaan pondasi 500 mm
H = 19500 mm 19.5 m 63.97638 ft
Discharge Pressure
/cm2 gauge P2 dis 180952.6 pa 1.785863 atm 0.785863 kg/cm2 gauge
Batasan V apakah masih baik atau tidak adalah apabila Maximum Fluid Velocity < Velocity Erosional
Ve= C
ρ^0.5
Nre 4.11E+05
Hf= 160.0672
Cl yang digunakan
Exit 1
Elbow 90 0.2
Elbow 90 0.2
Elbow 90 0.2
Elbow 90 0.2
Elbow 90 0.2
Elbow 90 0.2
Elbow 90 0.2
Elbow 90 0.2
Elbow 45 0.2
Elbow 45 0.2
Total Cl 3
Hl 6.693918
HL= 166.7611
ΔP 9860.539 lb/ft2
4.659505 atm
68.49472 psi
1.705 /1.55km
: #REF! ft (tinggi minimal diatas sumbu pompa)
: #REF! ft
: #REF! psia
: 7 psia